PubMed Health⌕ Search

Biomedical subjects

T Fujiki

Publications and source records attributed to T Fujiki.

At least 73 records · Page 4Linked to original sources

[Combination chemotherapy of CIS-diamminedichloroplatinum (II) and fluoropyrimidine derivatives for advanced gastric cancer: a preliminary report].

A total of thirteen patients with histologically-proved adenocarcinoma of stomach took part in this study at Saitama Cancer Center between July 1982 and September 1983; nine patients were considered evaluable. There were 7 male and 2 female patients with a median age of 52 yrs (range 42-75) and a median performance status of 3 (range 2-4). Patients were treated with a two drug combination of cis-diammine dichloroplatinum (II) and fluoropyrimidine derivatives (tegafur, cormobur ). Three out of 9 evaluable patients (33.3%) had a partial response which lasted 10 months. 6+ months, and 5+ months, respectively. The major toxic effect was a gastrointestinal symptom which was generally manageable. Myelosuppression was mild.

Adenocarcinoma↗

[Effect of cis-diammine dichloroplatinum, vindesine sulfate combination chemotherapy for advanced esophageal carcinoma].

Eleven patients with advanced squamous cell carcinoma of the esophagus were treated with a two-drug combination of cis-diammine dichloroplatinum and vindesine sulfate at Saitama Cancer Center between July 1982 and September 1983. Median age was 71 years old (range: 47-48) and 8 patients were greater than 70 years old. Median performance status was 3 (range: 1-4) by Koyama -Saito Criteria. Male female ratio was 6:5. Of the 11 patents, three obtained partial response (27.3%), lasting 8 weeks, 20 weeks+, and 42 weeks-, respectively, and three patients had minor response (27.3%). The major toxic effects including myelosuppression, nausea and vomiting were in general manageable.

Aged↗

The integral dose in panoramic intraoral x-ray tube radiography.

A Monte Carlo computer program was developed to estimate the integral dose to the head and thyroid for panoramic intraoral x-ray tube radiography. The advantage of this computer simulation is that it is able to avoid many of the difficulties associated with low-energy and low-dose x-ray dosimetry. The calculations were made for maxillary and mandibular projections separately, using 10 kv. increments between 40 and 60 kv. The results obtained were presented in terms of the integral dose per milliampere second. Typical integral doses for a routine examination of the head are 2.1 mJ. and 8.5 microJ for the thyroid during mandibular radiography and 1.7 microJ for the thyroid during radiography of the maxilla using 55 kv. and 0.5 mAs.

Computers↗