PubMed Health⌕ Search

Biomedical subjects

T G Quinn

Publications and source records attributed to T G Quinn.

10 recordsLinked to original sources

Rigid lens dynamics: lid effects.

PURPOSE: Lid architecture, lid tension, blink action, and blink rate may all influence rigid lens centration and stability. The aims of this study were to assess the nature of the relationship between lid geometry and lens position and to examine the influence of lens-lid interactions on the association between lens position and lens center of gravity and mass. METHODS: Eight subjects (four with high riding lenses and four with low riding lenses) participated in the study. Each subject was fit with 12 lenses-six designs in each of two materials. Lens center of gravity was calculated and lens mass was measured in every case. For each lens, the following four lens dynamics variables were assessed over a five blink cycle for both the vertical and horizontal meridians: 1) initial lens position; 2) settled lens position; 3) amount of lens movement; and 4) rate of lens movement. Lower lid position and palpebral aperture height were measured for each subject. RESULTS: Graphical analysis showed that a low upper lid position and small palpebral aperture promoted superior lens decentration, while a high upper lid position and wide palpebral aperature predisposed an individual to inferior lens decentration. Significant lid-lens overlap was a common finding with high riding lenses in both the initial and settled lens positions. The results also suggested that while a rigid lens tended to become more stable as the lens center of gravity shifted further behind the corneal apex, this gravitational effect was reduced for lenses that interacted with the upper lid. CONCLUSIONS: Lid geometry can influence rigid lens centration and stability by modifying the effects of lens design and lens mass. We recommend that consideration be given to the nature of potential lens-lid interactions prior to lens fitting.

Blinking↗

The influence of center of gravity and lens mass on rigid lens dynamics.

PURPOSE: Center of gravity and lens mass have both been shown to influence rigid lens centration and stability. The purpose of this study was to investigate the relative contributions of these two factors to rigid lens dynamics. METHODS: Eight subjects (four with high-riding lenses and four with low-riding lenses) participated in the study. Each subject was fit with 12 lenses-six designs in each of two materials. Center of gravity and lens mass were recorded in every case. For each lens, four lens dynamics variables were assessed over a five-blink cycle for both the vertical and the horizontal meridians: 1) initial lens position; 2) settled lens position; 3) amount of lens movement; and 4) rate of lens movement. RESULTS: Multiple regression and correlation analysis showed that center of gravity influences initial and settled lens position, in both the horizontal and the vertical meridians. Mass alone was found not to be a significant predictor of rigid lens dynamics. The effect of center of gravity on settled vertical lens position was only apparent when high rider and low rider subgroups were analyzed separately, with a posterior movement of the center of gravity being associated with a lowering of the settled lens position for high rider subjects, and a raising of the settled lens position for low rider subjects. The results suggest that a rigid lens will become more stable as the center of gravity is shifted further behind the lens vertex, but this effect is reduced as lens mass is increased. CONCLUSIONS: The location of the center of gravity of a rigid lens influences its on-eye centration and stability more so than does lens mass.

Contact Lenses↗

A 3-year prospective study of the clinical performance of daily disposable contact lenses compared with frequent replacement and conventional daily wear contact lenses.

PURPOSE: To determine the clinical performance of daily disposable contact lens wear compared to conventional daily wear contact lenses and frequent replacement contact lenses. METHODS: This 3-year prospective study was conducted in 12 U.S. practices. Of 338 eligible subjects enrolled (126 conventional daily wear, 144 frequent replacement, and 68 daily disposable), 229 subjects disposable group were compared with the conventional daily wear group and two sub-groups of frequent replacement subjects: (a) those with replacement at 2-weak intervals and (b) those with replacement at 1 or 3 months. RESULTS: Comparing the daily disposable and conventional daily wear groups, the daily disposable subjects were more likely to be asymptomatic, reported fewer symptoms of redness, cloudy vision and grittiness/dirty sensation, reported better vision and overall satisfaction, and had fewer lens surface deposits, complications, tarsal abnormalities, and unscheduled visits, while conventional daily wear subjects reported better lens handling. Comparing the daily disposable and frequent replacement (1/3 months) groups, daily disposable subjects reported fewer symptoms of foreign body sensation, redness, cloudy vision and grittiness/dirty sensation, reported better subjective vision, comfort and overall satisfaction, and has fewer lens surface deposits, complications, and tarsal abnormalities, while frequent replacement (1/3 months) subjects reported fewer dryness symptoms and better lens handling. Comparing the daily disposable and frequent replacement (2-weeks) groups, daily disposable subjects reported better subjective vision and overall satisfaction and had fewer lens surface deposits and tarsal abnormalities, while frequent replacement (2-weeks) subjects reported fewer photophobia symptoms. CONCLUSIONS: The results indicate that daily disposable wear may be the most trouble-free way of wearing contact lenses.

Adult↗

Development of new coronary atherosclerotic lesions during a 4-year multifactor risk reduction program: the Stanford Coronary Risk Intervention Project (SCRIP).

OBJECTIVES: This study attempted to determine whether an intensive multifactor risk reduction program conducted over 4 years would reduce the rate of development of new coronary artery lesions. BACKGROUND: Recent angiographic trials have generally demonstrated that normalization of plasma lipoprotein profiles reduces the rate of progression of established coronary lesions, but limited data exist on how these treatments influence the development of new lesions. METHODS: Three hundred men and women with coronary artery disease were randomized to multifactor risk reduction or usual care. Highly significant improvements in risk factors were achieved by the risk reduction group compared with minimal changes by the usual care group. Quantitative coronary angiography was performed on entry and after 4 years under identical conditions. A decrement in the minimal diameter of visually normal segments > 0.2 mm was considered to indicate new lesion formation. RESULTS: A total of 1,605 segments, representing 257 patients, were considered normal at baseline, with 804 and 801 disease-free segments in the usual care and risk reduction groups, respectively. Ninety-nine segments (6.1%) were identified by follow-up quantitative angiography and two angiographic observers as having new lesion formation (usual care 7.6%, risk reduction 4.7%, p = 0.05). New lesion formation was observed in 41 (31%) of 131 patients in the usual care group and in 29 (23%) of 126 patients in the risk reduction group (p = 0.16), with a mean number of new lesions/patient of 0.47 in the usual care group and 0.30 in the risk reduction group (p = 0.06). Multiple regression analysis identified on-study dietary fat intake as the best correlate with new lesion formation. CONCLUSIONS: These data indicate that intensive multifactor risk reduction tends to diminish the frequency of new coronary lesion formation.

Aged↗

Multisite comparison of contact lens modalities. Daily disposable wear vs. conventional daily wear in successful contact lens wearers.

BACKGROUND: RESULTS are reported for the first year of one facet of an ongoing multisite clinical investigation. In this article, one subpopulations of subjects wearing soft contact lenses on a daily disposable wear schedule (DDW is compared to a second subpopulation wearing lenses on a conventional daily wear (CDW) basis. METHODS: All subjects recruited were successfully wearing lenses on a conventional daily wear basis at the time of enrollment. In addition to an initial visit, follow-up visits occurred at 1, 4, 12, 26 and 52 weeks. Areas of assessment included vision, comfort, ocular health, subject-reported symptoms, lens surface deposits and overall satisfaction. A total of 70 subjects were dispensed lenses on a daily disposable schedule and 125 subjects were dispensed lenses on a conventional daily wear schedule. RESULTS: Five DDW subjects and 15 CDW subjects discontinued before the 52-week follow-up visit. When the findings of the 52-week follow-up visit were compared, the DDW group performed significantly better than the CDW group in the following areas: Snellen visual acuity, subjective vision and comfort assessment, symptomatology, lens deposits and overall satisfaction. In addition, while performance levels tended to improve in the DDW group when the results from the 52-week follow-up visit were compared with the 1-week follow-up visit, they tended to decline in the CDW group over this period of time. Subjects wearing lenses on a daily disposable basis were significantly less likely to report for an unscheduled visit than subjects wearing lenses on a conventional wear basis, with the DDW subjects reporting with less serious ocular health problems. CONCLUSIONS: Patients who were wearing conventional reusable daily wear lenses and refit into lens wear on a daily disposable basis realized clinically significant advantages compared to a similar population of patients who were refit with lenses worn on a conventional daily wear basis.

Adolescent↗

Component evaluation of cup/disk ratio estimation.

Cup/disk (C/D) ratio estimation is frequently used to evaluate cupping within the optic nerve head. Two components are involved in the determination of this value: (1) the cup and disk margin determination, and subsequently (2) the magnitude estimation of the cup size relative to the disk size. This study investigated the magnitude estimation component by asking fourth year optometry students to estimate C/D ratios on optic nerve head photographs and drawings. The importance of the magnitude estimation was demonstrated by the high degree of variability among subjects on the nerve head drawings upon which cup and disk margins were presented unambiguously. A subsequent survey of faculty clinicians indicated a large percentage of practitioners (41%) have no method they consciously use to help determine their C/D ratio estimate. A specific method is presented which allows clinicians to simply and logically deduce this magnitude estimation.

Glaucoma↗

Polymorphic corneal abnormalities.

Alterations of the deep corneal layers, which are manifest primarily as Hassall-Henle bodies in older patients, are a relatively frequent finding in the normal population. Changes which occur in Descemet's membrane and the endothelium earlier in life can be ascribed to various causes, including dystrophy, herpetic infections, and birth trauma. Six cases in which clear vesicles and scalloped lesions were found exclusively at the level of Descemet's membrane and the endothelium are reported. Although the polymorphic changes were in some cases extensive, visual acuity and, apparently, corneal physiology remained normal. The etiology for all cases was uncertain, but the evidence suggested a dystrophic origin or the occurrence of posterior corneal vesicles of a nonfamilial variety.

Adult↗

Human corneal epithelial oxygen demand--population characteristics.

Observed differences in corneal response to contact lens wear have been attributed to variations in individual corneal oxygen requirements. Anterior corneal oxygen flux was measured on 100 human eyes using a polarographic oxygen sensor to determine if differences could be measured among subjects. A distribution in corneal epithelial oxygen use was found to exist in the population.

Adolescent↗

Solubility effects on corneal oxygen measurement.

Various membrane materials have been attached to oxygen sensors during measurement of corneal oxygen uptake. Differences in the oxygen solubility characteristics of these membranes directly affect resulting flux values. Human corneal epithelial oxygen uptake values were obtained using an oxygen sensor in conjunction with polyethylene, Teflon, and polypropylene membranes attached to its tip. Conversion coefficients were calculated to relate findings obtained with each membrane-sensor system. New solubility constants were derived for polyethylene, Teflon, and polypropylene based on previous findings obtained with a saline (hydrophilic lens) membrane reservoir.

Cornea↗