5 recordsLinked to original sources

Calculations of charged-particle recoils, slowing-down spectra, LET and event-size distributions for fast neutrons and comparisons with measurements.

A rapid system has been developed for computing charged-particle distributions generated in tissue by any neutron spectra less than 4 MeV. Oxygen and carbon recoils are derived form R-matrix theory, and hydrogen recoils are obtained from cross-section evaluation. Application to two quite different fission-neutron spectra demonstrates the flexibility of this method for providing spectral details of the different types of charged-particle recoils. Comparisons are made between calculations and measurements of event-size distributions for a sphere of tissue 1 micrometer in diameter irradiated by these two neutron spectra. LET distributions have been calculated from computed charged-particle recoils and also derived from measurements using the conventional approximation that all charged particles traverse the chamber. The limitations of the approximation for these neutron spectra are discussed.

Carbon

Correlation of microdosimetric measurements with relative biological effectiveness from clinical experience for two neutron therapy beams.

Microdosimetric measurements were made for the neutron therapy beams at the University of Chicago and at the Cleveland Clinic with the same geometry and phantom material using the same tissue-equivalent spherical proportional counter and standard techniques. The energy deposition spectra (dose distributions in lineal energy) are compared for these beams and for their scattered components (direct beam blocked). The model of dual radiation action (DRA) of Kellerer and Rossi is employed to interpret these data in terms of biological effectiveness over this limited range of radiation qualities. The site-diameter parameter of the DRA theory is determined for the Cleveland beam by setting the biological effectiveness (relative to 60Co gamma radiation) equal to the relative biological effectiveness value deduced from radiobiology experiments and clinical experience. The resulting value of this site-diameter parameter is then used to predict the biological effectiveness of the Chicago beam. The prediction agrees with the value deduced from radiobiology and clinical experience. The biological effectiveness of the scattered components of both beams is also estimated using the model.

Humans

Obtaining S values for rectangular-solid tumors inside rectangular-solid host organs.

A method is described for obtaining S values between a tumor and its host organ for use with the MIRD formalism. It applies the point-source specific absorbed fractions for an infinite water medium, tabulated by Berger, to a rectangular solid of arbitrary dimensions which contains a rectangular tumor of arbitrary dimensions. Contributions from pairs of source and target volume elements are summed for the S values between the tumor and itself, between the remaining healthy host organ and itself, and between the tumor and the remaining healthy host organ, with the reciprocity theorem assumed for the last. This method labeled MTUMOR, is interfaced with the widely used MIRDOSE program which incorporates the MIRD formalism. An example is calculated.

Humans

Analytic microdosimetry for radioimmunotherapeutic alpha emitters.

Analytic microdosimetry using Fourier transform techniques has been applied to internal alpha emitters. These techniques need revision and simplification for use with short-lived radionuclides such as those which may be useful for radioimmunotherapy. Analytic methods may have advantages over Monte Carlo methods in some cases (e.g., where time is important). Applications to eight different source geometries show the usefulness of these techniques. Comparisons of some of the results of Monte Carlo calculations prove its accuracy. For a uniform source of 5.867-MeV alphas spread throughout the volume outside a cell surface, the two methods agree well. Results are within 1% both for the average specific energy and for the number of hits. Analytic microdosimetry provides an alternate method to use for the critical evaluation of models that seek to predict the relation between alpha energy deposition and cell survival data. Similarly, it may be helpful to point the way toward the rational interpretation of general biological results for antibodies labeled with alpha emitters.

Alpha Particles