PubMed Health⌕ Search

Biomedical subjects

T Gerber

Publications and source records attributed to T Gerber.

At least 19 recordsLinked to original sources

[The extracellular matrix structure in keratoconus].

PURPOSE: Keratoconus is a non-inflammatory disease characterized by progressive thinning of the central cornea. There are indications for an autosomal dominant heredity. Our purpose was to find correlations between gene expression and structural changes in extracellular matrix components. METHODS: Stromal RNA (keratoconus and comparison) was isolated from corneas, transformed to cRNA and analysed using biochips (Affymetrix). Structural investigations were performed by laser scanning and transmission electron microscopy. RESULTS: In keratoconus corneas there was an upregulation of different extracellular matrix components (collagen XV, metalloproteases) and a down-regulation of collagen IV (alpha1, alpha3) and versican. The morphological changes correlated to genetic obtained data. The orthogonal arrangement of the collagen fibrills (anteriorly and central) was altered in the collagen matrix of keratoconus corneas. CONCLUSIONS: The changes point on deregulation of the matrix arrangement. The interest in the cause of the disease is focused on the interfibrillar arrangement, the interaction between collagen and proteoglucanes.

Adult↗

Structure of silica in Equisetum arvense.

Silicified regions in the stem and leaf of the horsetail Equisetum arvensewere studied by scanning and transmission electron microscopy. The silica was present as a thin layer on the outer surface with variation in the size of this layer depending on the part investigated. There was a dense arrangement of silica spheres with some density fluctuations. A loose arrangement of silica particles with variation in their size was found beneath this dense arrangement suggesting the agglomeration of silica. An electron diffraction pattern showed the presence of amorphous silica, with the short range order being comparable to that of silica from other chemical sources. The medium range order shows the presence of silica with a high inner surface. SAXS measurements correlate with the particle size observed in TEM, and provide values for surface fractals. A new method of plasma ashing to remove the organics is also described.

Equisetum↗

[Cystic lymphangioma with endosalpingiosis as a rare cause of gastrointestinal bleeding].

We report on a 31-year-old woman with an iron-deficiency anemia and positive Guaiac test, existing for more than 2 years. Despite an extensive gastrointestinal examination a bleeding source could not be found. Also angiography of the abdominal arteries with injection of heparin as provocative protocol was normal. Enteroclysis showed a remarkable finding which led to laparotomy. A cystic lymphangioma with endolymphatic endosalpingiosis as the bleeding source was identified and removed. Lymphangioma is a rare benign soft tissue tumor which usually appears during the first 2 years of life. Only in some cases the lymphangioma is intraabdominal and there can be different, no specific symptoms. Endosalpingiosis is also a rare benign disease, it consists of scattered epithelium of the Fallopian tube. It is the first case to our knowledge, in which the appearance of the endosalpingiosis in a lymphangioma is described.

Adult↗

Hepatic encephalopathy in liver cirrhosis: pathogenesis, diagnosis and management.

The pathogenesis of hepatic encephalopathy (HE) is unknown. Many theories have been proposed. Most established therapies are based on such theories but since no theory has have ever been proved, therapies have to be considered empiric. The spectrum of HE ranges from minimal cerebral functional deficits, which can only be found by sensitive psychometric tests, to coma with signs of decerebration. HE has arbitrarily been divided into stages. A number of precipitating factors are known and the first line of therapy should always be the elimination of these factors. The differential diagnosis includes all states of impaired consciousness and deficits in cerebral function in patients with chronic liver disease, and clinical and biochemical tests to differentiate are indicated. The therapeutic options for HE include: protein restriction only for a limited time in comatous patients; nonabsorbable antibiotics (aminoglycosides), which because of adverse effects are also limited to higher grades of HE: intestinal cleansing which is applicable in all degrees of HE; lactulose, branched chain aminoacids and ornithin aspartate which have been proven to be effective and can be applied long term in patients with lower grades of HE.

Anti-Bacterial Agents↗

[Cartilage oligomeric matrix protein (COMP): the role of a non-collagen cartilage matrix protein as a marker of disease activity and joint destruction in patients with rheumatoid arthritis and osteoarthritis].

UNLABELLED: Today, we can assess criteria to predict the tissue destruction and progression of Rheumatoid Arthritis (RA) and Osteoarthritis (OA) only in a late stage of the disease. It would be an advantage to have biochemical markers of disease activity and joint destruction to optimize therapy. PATIENTS AND METHODS: In this cross-sectional study with 37 RA and 20 OA patients (disease duration 119 +/- 130 months for RA and 41 +/- 73 months for OA), ESR, CRP, disease activity score (DAS), the functional status of RA (American College of Rheumatology), and the radiological scoring systems of Larsen and Kellgren/Lawrence, respectively, were used as parameters for disease activity and joint destruction. Cartilage oligomeric matrix protein (COMP) was measured with an enzyme-linked immunosorbent assay (ELISA) in serum and synovial fluid, COMP fragments with immunoblot in the synovial fluid. RESULTS: The mean COMP value in synovial fluid was 38 ug/ml (RA) and 46 ug/ml (OA); 6.5 ug/ml (RA) and 3.4 ug/ml (OA) in serum. RA patients had a higher amount of small COMP fragments in synovial fluid than OA patients. In RA patients, there was a significant positive correlation between disease activity (DAS) and COMP in synovial fluid and serum, a negative correlation between functional status of RA and serum COMP and between radiologic joint destruction of the knee and serum COMP. In OA patients, there was a significant correlation of joint space width and synovial fluid COMP. DISCUSSION: A high clinical disease activity (DAS) correlated with high COMP values in serum and synovial fluid and with increasing proteolytic activity (higher amount of small COMP fragments especially in RA). An increased turnover of cartilage matrix in joint inflammation might explain this correlation. The correlation of decreased COMP with decreased functional status in RA and increased joint destruction is compatible with a loss of cartilage and less turnover. The correlation between joint space width and increased COMP in OA patients with short disease duration might be explained with a higher turnover of the cartilage matrix in the early stage of the disease.

Adult↗

Use of health and human services by community-residing people with dementia.

This article reports on the use of and need for health and human services by community-residing people with dementia. Telephone interviews were conducted with a sample of 608 caregivers of such individuals who were randomly selected from a dementia registry. Caregivers reported using an average of 3.2 health services and 3.7 human services to assist them in the care of the person with dementia. Despite the high level of services use, 73 percent of the caregivers indicated a high need for at least one additional service, and 72 percent indicated that additional services would reduce the likelihood of institutionalization of the recipient. Although services use was more frequent than expected, many caregivers lacked knowledge about services, a fact that suggested that social workers have a vital information and referral role to play.

Aged↗

Measurement of myocardial infarct size by electron beam computed tomography: a comparison with 99mTc sestamibi.

RATIONALE AND OBJECTIVES: The authors sought to determine, using a variety of regional left ventricular ejection fraction (EF) and wall thickening (WTh) criteria, the applicability to measure left ventricular (LV) infarct size using electron-beam CT (EBCT) in patients as compared with technetium 99m (99mTc) sestamibi scanning as reference standard. METHODS: Twelve patients (age 57 +/- 11 years) underwent 99mTc sestamibi scanning and EBCT at hospital discharge after an acute index anterior myocardial infarction. Left ventricular infarct size was defined using standard 99mTc sestamibi scanning. Regional EF and WTh were analyzed on each EBCT scan with use of a floating epicardial centroid method. In five contiguous LV tomograms, the amount of infarcted myocardium was estimated using the following EF and WTh criteria: EF < or = 35%, 30%, 25%, 20%, and WTh < or = 2 mm, 1 mm, and 0 mm. RESULTS: Infarct size measured with 99mTc sestamibi was 33.3% (+/- 18.3%) (mean +/- SD, range 6%-54%) of the LV. Using an EF < or = 35% or absolute WTh < or = 2 mm as criteria for infarcted myocardium, EBCT yielded 28% (+/- 17%) and 27% (+/- 16%), respectively (P = NS, paired Student's t test, versus 99mTc sestamibi). Although, with use of the other criteria, EBCT tended to underestimate infarct size compared with 99mTc sestamibi, a close correlation across the entire range of infarct size determinations (range, 0.72-0.82) regardless of the underlying criteria suggested an internal consistency of the data. CONCLUSIONS: Quantitative analysis of regional myocardial function by EBCT allows an estimate of anterior infarct size when compared with 99mTc sestamibi. This suggests that in addition to previously established applications after acute myocardial infarction such as examination of cardiac volumes and mass, EBCT also may provide for infarct size determination.

Adult↗

[Acute gonarthritis--application of current diagnostic study methods exemplified by a case report].

The evaluation of acute inflammatory knee arthritis deserves special emphasis, because immediate benefit may result from identification and treatment of the underlying disease. The diagnostic approach to and the differential diagnosis of an acute knee arthritis are presented. By means of a case report, the use of the needle arthroscopy and the polymerase chain reaction (PCR) method for analysis of synovial fluid and synovial tissue in the diagnosis and evaluation of treatment of Lyme disease is described. The significance of this approach in diagnostic and therapeutic procedures has yet to be defined.

Arthritis, Infectious↗

Intravascular ultrasound after low and high inflation pressure coronary artery stent implantation.

OBJECTIVES: We sought to characterize the differences seen after low or high pressure coronary artery stent deployment as assessed by intravascular ultrasound. BACKGROUND: Until 1992, the success of stent deployment was assessed by angiographic criteria only, but in 1993 the procedure was expanded to include postprocedural single-use intravascular ultrasound imaging. Ultrasound criteria for successful stent deployment were 1) symmetry, 2) minimal lumen diameter > 3.0 mm, 3) no echo-free spaces between the stent and the vessel, and 4) no uncovered dissections. METHODS: We used mechanical 4.8F or 3.5F 20- or 30-MHz monorail single-use intravascular ultrasound catheters. RESULTS: Fifty-two patients were included, 28 treated in 1991 and 1992 (group A) and 24 treated in 1993 or 1994 (group B); 87% of patients underwent elective stent implantation. The number of echocardiographic studies per patient increased from 1 +/- 0.1 (mean +/- SD) in group A to 2.0 +/- 0.85 in group B. Mean maximal balloon size increased from 3.3 +/- 0.33 to 3.73 +/- 0.24 mm and maximal inflation pressure from 6.9 +/- 1.1 to 15.8 +/- 2.4 bar (p < 0.001). The eccentricity index was 0.915 +/- 0.04 in group B versus 0.87 +/- 0.05 in group A. Minimal lumen diameter measured by echocardiography increased from 2.55 +/- 0.41 mm in group A to 3.14 +/- 0.37 mm in group B. The final mean values per cross-sectional area as a percent of calculated balloon area were similar in group A (67.5 +/- 23%) and group B (66.5 +/- 22.9%). No major acute complications occurred in either group; subacute thrombosis developed in two patients, both in group A. CONCLUSIONS: Intravascular ultrasound data confirm that high pressure stent deployment leads to increased minimal lumen area. Despite high pressure stent deployment, homogeneous stent geometry and optimal stent expansion were not observed in all patients.

Aged↗

Intravascular ultrasound imaging in acute aortic dissection.

OBJECTIVES: This study was performed to determine the potential of intravascular ultrasound in the detection and delineation of aortic dissection. BACKGROUND: Intravascular ultrasound is a new technique capable of displaying real-time cross-sectional images of arterial vasculature. Its clinical use has been explored mostly in coronary and peripheral arterial circulation. METHODS: Intravascular ultrasound imaging of the aorta was performed using a 20-MHz ultrasound catheter in 28 patients with suspected aortic dissection. All patients underwent contrast angiography; 7 had computed tomography; and 22 had transesophageal echocardiography. RESULTS: Imaging of the aorta from the root level to its bifurcation was performed in all patients in an average of 10 min. No complications occurred. Dissection was present in 23 patients and absent in 5. In the patients without dissection, intravascular ultrasound revealed normal aortic anatomy. In all 23 patients with dissection, intravascular ultrasound demonstrated the intimal flap and true and false lumena. The longitudinal and circumferential extent of aortic dissection, contents of the false lumen, involvement of branch vessels and the presence of intramural hematoma in the aortic wall could also be identified. In cases where aortography could not define the distal extent of the dissection, intravascular ultrasound did. CONCLUSIONS: Our experience in this series of patients with aortic dissection indicates that intravascular ultrasound could be valuable in the identification and categorization of aortic dissection and in the description of associated pathologic changes that may be clinically important. It can be performed rapidly and safely and could serve as an alternative or adjunct diagnostic procedure in patients with aortic dissection.

Acute Disease↗

Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo.

Intravascular ultrasound imaging (IVUS) was performed to elucidate the discrepancy between clinical history and angiographic findings and to measure the diameter and area of the lumen of the normal left coronary artery in 55 patients who presented with chest pain but had normal coronary angiograms. The left coronary artery (LCA) was scanned with a 4.8F, 20 MHz mechanically rotated ultrasound catheter at 413 sites. Atherosclerotic lesions were identified at 72 (17%) sites in 25 patients. The mean (SD) (range) plaque area was 5.55 (3.56) mm2 (2-26 mm2) and it occupied 28.8 (9.6)% (13-70%) of the coronary cross sectional area. Calcification was detected at 24 (33%) atherosclerotic sites in nine patients. The correlation coefficients for the lumen dimensions measured at normal sites by IVUS and by angiography were r = 0.93 (SEE = 0.43) mm for lumen diameter and r = 0.89 (SEE = 4.27) mm2 for lumen area (both p < 0.001). 16 of the 30 patients in whom no atherosclerotic plaques were detected in the LCA lumen by IVUS had no risk factors of coronary artery disease. The cross sectional area of 90 consecutive images of left main coronary artery (LMCA), proximal left anterior descending coronary artery (proximal LAD), and mid LAD was measured in these 16 subjects. The mean (SEM) areas at end diastole were LMCA 17.33 (7.98) mm2; proximal LAD 13.56 (5.85) mm2; mid LAD 9.75 (4.67) mm2. During the cardiac cycle the cross sectional area changed by 10.2 (4.0)% in the LMCA, by 8.3 (4.7)% in the proximal LAD, and by 9.8 (4.0)% in the mid LAD. In 11 patients with plagues the change in cross sectional area in plague segments (5.8(3.1)%) was significantly lower than in the segments from patients without plagues (p < 0.001). Lumen area reached a maximum in early diastole rather than in late diastole. IVUS can imagine atherosclerotic lesions that are angiographically silent; it also provides detailed information about plague characteristics. The variation in coronary cross sectional area during the cardiac cycle should not be ignored during quantitative analysis. Maximum dimensions in normal segments are reached in early diastole. Further studies are needed to clarify the clinical significance of atherosclerosis detected by IVUS in patients presenting with chest pain but normal coronary angiography.

Adult↗

Coronary artery remodeling in atherosclerotic disease: an intravascular ultrasonic study in vivo.

BACKGROUND: Pathologic studies have revealed that coronary arteries undergo compensatory enlargement in the presence of atherosclerosis. METHODS: In order to assess coronary artery remodeling in vivo, we used intravascular ultrasound to examine 46 patients (36 men and 10 women; aged 58.2 +/- 6.8 years) with non-calcified plaques. The vessel, lumen, and plaque areas of the atherosclerotic and of normal proximal and distal segments were determined. RESULTS: A total of 92 atherosclerotic segments were analyzed. The degree of stenosis ranged from 9.2 to 92.8% (mean 34.1 +/- 16.9%) and the plaque area from 2 to 19.6 mm2 (mean 6.3 +/- 3.6 mm2). The vessel area of the atherosclerotic segment (mean 20.4 +/- 7.3 mm2) was larger than that of the proximal segment (mean 18.7 +/- 7.3 mm2, P = 0.018). The vessel area increased in proportion to plaque area. This relationship can be described using the equation y = 23.5(1-e-0.35x). The difference between the vessel area in the atherosclerotic segment and that in the proximal normal segment correlated with the percentage of stenosis (r = 0.53, P < 0.005) until the degree of stenosis exceeded 45%. CONCLUSION: This study indicates that coronary artery remodeling, previously observed in pathologic studies, can be evaluated using intravascular ultrasound in vivo. As a result of the compensatory enlargement of the vessel, coronary angiography cannot be used to detect or exclude the early signs of coronary atherosclerosis.

Adult↗

Intravascular ultrasound imaging of arterial wall architecture.

Intravascular ultrasound (IVUS) is a promising new technique for assessing vascular morphology and structure. Controversy exists whether the three-layer appearance of the arterial wall correctly reflects the histologic structures of the intima, media, and adventitia. We performed an experimental study to clarify the three-layer appearance. The vessel wall architecture was analyzed by IVUS on eight different kinds of plastic cylinders, 24 normal blood vessels from pigs, and 59 human arterial segments. A distinct three-layer appearance was observed on all the plastic cylinders when the ultrasound beam was perpendicular to the wall. A three-layer appearance was also seen in the arterial wall, in the muscular (iliac, femoral artery) and elastic types (aorta), when the echo beam was perpendicular to the vessel wall. The three-layer pattern was even observed on the arterial wall when the intima was removed. Furthermore, the removed intima itself provided a three-layer image. Histologic examination showed that there was no correspondence between the IVUS three-layer appearance and the intima, media, and adventitia. Moreover, we also performed IVUS on nine patients who suffered from aortic dissection. Intravascular ultrasonic visualization of the dissected intima showed a distinct three-layer pattern. The pattern disappeared when: (1) the echo beam was not perpendicular to the vessel wall; (2) there was connective tissue around the vessel wall; (3) there was arterial wall calcification; or (4) the vessel wall was too thick or the distance between the ultrasound transducer and the vessel wall was too large.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Dissection following balloon angioplasty of aortic coarctation: review of the literature.

Balloon angioplasty of the coarctation of the aorta can result in intimal or medial or even adventitial dissections as demonstrated by in vitro studies and animal experiments. As a typical sign of stretching of the aortic wall, patients complain of pain during the angioplasty procedure. In the literature, aortic wall rupture and ventricular fibrillation during the procedure are reported. Additional sudden deaths can occur within 40 hours after the procedure. Mortality ranges from 0.1% to 2.5%. By transesophageal echocardiography, monitoring of balloon angioplasty, control of the positioning of the balloon, and control of the results and detection of complications are possible. Intimal as well as medial dissections can be detected with observed healing for intimal but also medial dissections. In order to avoid the patient's discomfort, intraaortic ultrasound will be used in the future, when major methodological improvements are done. Computed tomography demonstrates medial dissections but is not able to visualize intimal dissections. Using computed tomography and magnetic resonance after angioplasty of the coarctation of the aorta, irregularities are described in up to 17% of the patients. For angiography, a low detection rate of medial dissections has to be expected, when not biplane angiographies of the whole thoracic aorta are performed. Medial dissections can be seen, but intimal dissections are missed. In conclusion, a review of the literature demonstrates a high incidence of intimal and medial dissections after angioplasty of the coarctation of the aorta with spontaneous healing in most patients. As is the way with coronary angioplasty, aortic wall ruptures are rare, but stand-by surgery is necessary.

Aortic Dissection↗

[Intravascular ultrasound in patients with suspected aortic dissection: comparison with transesophageal echocardiography].

Thirteen patients with suspected aortic dissection (two women, 11 men, age 61 +/- 10.8 years) underwent transesophageal echocardiography (TEE), intravascular ultrasound (IVUS), angiography, and in part computed tomography (CT). TEE was performed using 3.5 or 3.75 MHz ultrasound transducers. IVUS examination was done using a 6F 20 MHz "rotational-tip" IVUS catheter (Boston Scientific) advanced over a guiding-wire positioned in the ascending aorta by the "side-saddle" technique. In two patients it was not possible to advance the catheter into the abdominal aorta. Of the remaining 11 patients, eight had aortic dissection (six Typ III, one Typ II, and one Typ I, de Bakey classification). Two patients had aortic aneurysms without dissection and one patient had a perforation of the ascending aorta. TEE, CT, and angiography led to the correct diagnosis in all patients, while IVUS failed to provide precise information within the ascending aorta and the aortic arch. Reasons were the limited scanfield of the 20 MHz transducer and the inability to steer and position the IVUS catheter. Contrary to the limited value in the ascending aorta, IVUS could successfully scan the entire descending aorta, including the dissection membrane and the originating vessels, if the max. diameter was less than 4 cm. No adverse effects occurred. Intravascular ultrasound allows to scan the entire aorta in patients with suspected aortic dissection. The current limitations can be solved only by the introduction of steerable and/or low frequency catheters.

Aged↗