Publications and source records attributed to T Groves.

15 recordsLinked to original sources

Inspecting the NHS.

Explore the source record for details and available documents.

Community Health Services

Minimization of dose as a criterion for the selection of imaging modes in electron microscopy of amorphous specimens.

A fundamental limitation in electron microscopy of organic specimens is radiation damage by the electron beam. To minimize damage it is necessary to have maximum information collection for a given dose. Various modes of operation of conventional and scanning transmission microscopes are compared with respect to their ability to detect small changes in specimen thickness or density with a given signal to noise ratio. Incoherent imaging is assumed, and this is expected to apply to amorphous specimens under a variety of microscope conditions. For either very thin or very thick specimens, the scanning transmission microscope is found to require nearly 10 times less dose than a conventional microscope for the same signal to noise ratio in the image. For specimens of intermediate thickness, scanning and conventional transmission electron microscopes are roughly equivalent.

Electrons

Thick specimens in the CEM and STEM. Resolution and image formation.

A theory of resolution and image formation is presented for thick amorphous specimens in transmission electron microscopes. Eight modes of operation are considered, four in the scanning transmission electron microscope (STEM) and four in the conventional electron microscope (CEM). A thick specimen is defined here as one in which the resolution of detail is limited by plural scattering of the electron beam. In practice this includes films on the order of a micron in thickness. An analytic theory of plural incoherent scattering is developed which is general with respect to material and beam voltage. The theory gives the distribution of elastically scattered electrons as a function of transverse coordinate and angles, and is directly applicable to optical systems. The theory applies to all thicknesses normally encountered, and includes thin specimens as well as thick specimens. Criteria are proposed for evaluation of the quality of microscope images, and the modulation transfer function is applied to determine some practical estimates of picture quality. The STEM is found to have distinct advantages over the CEM for thick specimens. For a carbon specimen one micron thick a STEM operating in bright field at 90 keV produces an image which is roughly equivalent to that of a CEM operating in bright field at 1 MeV. Improvement can be obtained in the CEM by filtering out eneryg-loss electrons which degrade resolution due to chromatic aberration. This results in a reduction in signal intensity and usable thickness, however.

Electrons

Christmas 1941.

Explore the source record for details and available documents.

Africa, Northern