PubMed HealthSearch

Biomedical subjects

T H Mareci

Publications and source records attributed to T H Mareci.

6 recordsLinked to original sources

In vivo magnetic resonance imaging of fetal cat neural tissue transplants in the adult cat spinal cord.

Magnetic resonance (MR) imaging was evaluated for its possible diagnostic application in determining the survival of fetal central nervous system tissue grafts in the injured spinal cord. Hemisection cavities were made at the T11-L1 level of eight adult female cats. Immediately thereafter, several pieces of tissue, either obtained from the fetal cat brain stem on embryonic Day 37 (E-37), from the fetal neocortex on E-37, or from the fetal spinal cord on E-23, were implanted into the cavities made in seven cats. The eighth cat served as a control for the effect of the lesion only. In another group of four animals, a static-load compression injury was made at the L-2 level. Seven weeks later, the lesion was resected in three cases and fragments of either fetal brain-stem or spinal cord tissue were introduced. A small cyst was observed in a fourth cat in the compression injury group and a suspension of dissociated E-23 brain-stem cells was injected into this region of cavitation without disturbing the surrounding leptomeninges. Five months to 2 years posttransplantation, MR imaging was performed with a 2.0-tesla VIS imaging spectrometer by acquiring multislice spin-echo images (TR 1000 msec, TE 30 msec) in both the transverse and sagittal planes. Collectively, these intermediate-weighted images revealed homogeneous, slightly hyperintense signals at the graft site relative to the neighboring host tissue in seven of the 11 graft recipients. Two of the remaining four cats exhibited signals from the graft site that were approximately isointense with the adjacent host spinal cord, and the final two cats and the lesion-only control presented with very hypointense transplant/resection regions. The hyperintense and isointense images were tentatively interpreted as representing viable graft tissue, whereas the hypointense transplant/resection sites were considered to be indicative of a lack of transplant survival or the absence of tissue in the lesion-only control animal. Postmortem gross inspection of fixed specimens and light microscopy verified the MR findings in the control animal in 10 of the 11 graft recipients by showing either transplants and/or cysts corresponding to the MR images obtained. In one cat in the hemisection group, histological analysis revealed a very small piece of graft tissue that was not detected on the MR images. Therefore, it is suggested that within certain spatial- and contrast-resolution limits, MR imaging can reliably detect the presence of transplanted neural tissue in both the hemisected and compression-injured spinal cord of living animals.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals

Selective Fourier transform localization.

We have introduced the selective Fourier transform technique for spectral localization. This technique allows the acquisition of a high-resolution spectrum from a selectable location with control over the shape and size of the spatial response function. The shape and size of the spatial response are defined during data acquisition and the location is selectable through processing after the data acquisition is complete. The technique uses pulsed-field-gradient phase encoding to define the spatial coordinates. In this paper the theoretical basis of the selective Fourier transform technique is developed and experimental results are presented, including comparisons of spectral localization using either the selective Fourier transform method or conventional multidimensional Fourier transform chemical-shift imaging.

Fourier Analysis

Chemical and radiochemical stability of the adrenal-scanning agents, 6beta-iodomethyl-19-norcholest-5(10-en-3beta-ol and 19-iodocholest-5-en-3beta-ol.

The chemical stabilities of the adrenal-scanning agents, 6beta-iodo-methyl-19-norcholest-5(10)-en-3beta-ol (6-iodomethylnorcholesterol) and 19-iodocholest-5-en-3beta-ol (19-iodocholesterol), and several of their derivatives were examined by 13C nuclear magnetic resonance. Neat 6-iodomethylnorcholesterol, sealed in glass under nitrogen and stored at 0 degrees C, remains 98 mole% chemically pure for 3 months. Neat 19-iodocholesterol, stored in the dark at 25 degrees C, remains 98 mole% chemically pure for 3 months. Either 6-iodomethylnorcholesterol-125I or-131I, informulation and stored at 5 degrees C, will remain greater than 97% radiochemically pure for at least 15 days. Labelled 19-iodocholesterol, formulated and stored under the same conditions, shows 20% decomposition after 3 weeks and 40% after 6 weeks.

Adrenal Glands

Synthesis and purification of radioactive 6beta-iodomethyl-19-norcholest-5(10)-en-3beta-ol.

A method for the synthesis and purification of 6beta-iodomethyl-19-norcholest-5(10)-ene-3beta-ol-131I of greater than 98 mole% chemical purity and greater than 99% radiochemical purity is presented. Carbon-13 and proton NMR were used to establish the identity and purity. Discrepancies in the characterization of this compound, previously published by two other research groups, are discussed.

Cholestenes