PubMed Health⌕ Search

Biomedical subjects

T H Marwick

Publications and source records attributed to T H Marwick.

At least 37 records · Page 2Linked to original sources

Refinements in stress echocardiographic techniques improve inter-institutional agreement in interpretation of dobutamine stress echocardiograms.

AIMS: To determine the degree of inter-institutional agreement in the assessment of dobutamine stress echocardiograms using modern stress echocardiographic technology in combination with standardized data acquisition and assessment criteria. METHOD AND RESULTS: Among six experienced institutions, 150 dobutamine stress echocardiograms (dobutamine up to 40 microg x kg(-1) min(-1) and atropine up to 1 mg) were performed on patients with suspected coronary artery disease using fundamental and harmonic imaging following a consistent digital acquisition protocol. Each dobutamine stress echocardiogram was assessed at every institution regarding endocardial visibility and left ventricular wall motion without knowledge of any other data using standardized reading criteria. No patients were excluded due to poor image quality or inadequate stress level. Coronary angiography was performed within 4 weeks. Coronary angiography demonstrated significant coronary artery disease (> or = 50% diameter stenosis) in 87 patients. Using harmonic imaging an average of 5.2+/-0.9 institutions agreed on dobutamine stress echocardiogram results as being normal or abnormal (mean kappa 0.55; 95% CI 0.50-0.60). Agreement was higher in patients with no (equal assessment of dobutamine stress echocardiogram results by 5.5+/-0.8 institutions) or three-vessel coronary artery disease (5.4+/- 0.8 institutions) and lower in one- or two- vessel disease (5.0+/-0.9 and 5.2+/-1.0 institutions, respectively; P=0.041). Disagreement on test results was greater in only minor wall motion abnormalities. Agreement on dobutamine stress echocardiogram results was lower using fundamental imaging (mean kappa 0.49; 95% CI 0.44-0.54; P<0.01 vs harmonic imaging). CONCLUSION: Modern echocardiographic technology in combination with standardized digital image processing and uniform reading criteria results in a higher inter-institutional agreement in the interpretation of dobutamine stress echocardiogram compared to historic reports.

Adrenergic beta-Agonists↗

Quantitative techniques for stress echocardiography: dream or reality?

Stress echocardiography is now an everyday clinical tool. However, the substantial evidence base that supports its use is largely derived from expert centres, and concerns have been expressed about the performance of the test in less expert hands. A unifying feature of the problems of stress echocardiography is its subjective assessment. This review examines the consequences of qualitative interpretation and the benefits of developing a quantitative approach. Although no quantitative approach is in widespread clinical use, several alternative techniques are feasible, and this area warrants further study.

Clinical Trials as Topic↗

Effect of tissue Doppler on the accuracy of novice and expert interpreters of dobutamine echocardiography.

The subjective interpretation of dobutamine echocardiography (DBE) makes the accuracy of this technique dependent on the experience of the observer, and also poses problems of concordance between observers. Myocardial tissue Doppler velocity (MDV) may offer a quantitative technique for identification of coronary artery disease, but it is unclear whether this parameter could improve the results of less expert readers and in segments with low interobserver concordance. The aim of this study was to find whether MDV improved the accuracy of wall motion scoring in novice readers, experienced echocardiographers, and experts in stress echocardiography, and to identify the optimal means of integrating these tissue Doppler data in 77 patients who underwent DBE and angiography. New or worsening abnormalities were identified as ischemia and abnormalities seen at rest as scarring. Segmental MDV was measured independently and previously derived cutoffs were applied to categorize segments as normal or abnormal. Five strategies were used to combine MDV and wall motion score, and the results of each reader using each strategy were compared with quantitative coronary angiography. The accuracy of wall motion scoring by novice (68 +/- 3%) and experienced echocardiographers (71 +/- 3%) was less than experts in stress echocardiography (88 +/- 3%, p <0.001). Various strategies for integration with MDV significantly improved the accuracy of wall motion scoring by novices from 75 +/- 2% to 77 +/- 5% (p <0.01). Among the experienced group, accuracy improved from 74 +/- 2% to 77 +/- 5% (p <0.05), but in the experts, no improvement was seen from their baseline accuracy. Integration with MDV also improved discordance related to the basal segments. Thus, use of MDV in all segments or MDV in all segments with wall motion scoring in the apex offers an improvement in sensitivity and accuracy with minimal compromise in specificity.

Aged↗

Prediction of mortality by exercise echocardiography: a strategy for combination with the duke treadmill score.

BACKGROUND: In studies generally involving short follow-up, exercise echocardiography has been shown to predict composite end points. We sought to study the prediction of mortality with this test and to devise a strategy for combination with standard exercise testing. METHODS AND RESULTS: Clinical, exercise testing, and echocardiographic data were collected in 5375 patients (aged 54+/-14 years, 3880 men) undergoing exercise echocardiography. The Duke treadmill score was derived from the results of treadmill exercise testing. Resting left ventricular (LV) function and the presence and severity of ischemia were interpreted by expert observers. Follow-up at 10.6 years (mean 5.5+/-1.9 years) was complete in 5211 patients (97%). The Duke score classified 59% of patients as low risk, 39% as intermediate risk, and 2% as high risk. Resting LV dysfunction was present in 1445 patients (27%), and the exercise echocardiogram was abnormal in 2525 patients (47%). Death occurred in 649 patients (12%). Over the first 6 years of follow-up, those with normal exercise echocardiograms had a mortality of 1% per year. Ischemia was an independent predictor of mortality. In sequential Cox models, the predictive power of clinical data was strengthened by adding the Duke score, resting LV function, and the results of exercise echocardiography. Exercise echocardiography was able to substratify patients with intermediate-risk Duke scores into groups with a yearly mortality of 2% to 7%. CONCLUSIONS: A normal exercise echocardiogram confers a low risk of death, and positive results are an independent predictor of death; ischemia is incremental to other data. This test may be particularly useful in patients with intermediate-risk Duke treadmill scores.

Adult↗

Application of tissue Doppler to interpretation of dobutamine echocardiography and comparison with quantitative coronary angiography.

The main limitation of dobutamine echocardiography (DE) is its subjective interpretation. We sought to reduce the need for expert interpretation by developing a quantitative approach to DE using myocardial Doppler velocity (MDV) in 242 patients undergoing DE. In 128 patients with a normal dobutamine echocardiogram, the normal range was designed to give a specificity of 80%. The accuracy of this range was investigated in 114 consecutive patients who underwent coronary angiography within 2 months of DE. A standard dobutamine echocardiographic protocol was used, with MDV gathered from color tissue Doppler at rest and peak stress. Wall motion at these stages was scored by experienced observers using a 16-segment model and MDV was measured off-line. Sensitivity and specificity of wall motion scoring and MDV were obtained by comparison with angiographic evidence of disease, defined as stenosis > 50% of the coronary artery diameter. The normal range in tethered segments (septum, anteroseptum, and inferior) was > or = 7 cm/s in the basal segments and > or = 5 cm/s in the midsegments. In the free wall (anterior, lateral, and posterior), the cutoff was > or = 6 cm/s in the base and > or = 4 cm/s in the midventricle. Of 114 patients undergoing angiography, 84 (75%) had significant stenoses, and the sensitivity of wall motion scoring and MDV were 88% and 83%, respectively, with specificities of 81% and 72% (p = NS). The accuracy was similar overall (86% vs 80%), as well as in each vascular territory. These data suggest that a fully quantitative interpretation of DE using site-specific normal ranges of tissue Doppler, which account for regional variations of base-apex function, is feasible and equivalent in accuracy to expert wall motion scoring.

Adult↗

Prediction of mortality using dobutamine echocardiography.

OBJECTIVES: We sought to find out whether dobutamine echocardiography (DbE) could provide independent prediction of total and cardiac mortality, incremental to clinical and angiographic variables. BACKGROUND: Existing outcome studies with DbE have examined composite end points, rather than death, over a relatively short follow-up. Clinical and stress data were collected in 3,156 patients (age 63 +/- 12 years, 1,801 men) undergoing DbE. Significant stenoses (>50% diameter) were identified in 70% of 1,073 patients undergoing coronary angiography. Total and cardiac mortality were identified over nine years of follow-up (mean 3.8 +/- 1.9). Cox models were used to analyze the effect of ischemia and other variables, independent of other determinants of mortality. RESULTS: The dobutamine echocardiogram was abnormal in 1,575 patients (50%). Death occurred in 716 patients (23%), 259 of whom (8%) were thought to have died from cardiac causes. Patients with normal DbE had a total mortality of 8% per year and a cardiac mortality of 1% per year over the first four years of follow-up. Ischemia and the extent of abnormal wall motion were independent predictors of cardiac death, together with age and heart failure. In sequential Cox models, the predictive power of clinical data alone (model chi-square 115) was strengthened by adding the resting left ventricular function (model chi-square 138) and the results of DbE (model chi-square 181). In the subgroup undergoing coronary angiography, the power of the model was increased to a minor degree by the addition of coronary anatomy data. CONCLUSIONS: Dobutamine echocardiography is an independent predictor of death, incremental to other data. While a normal dobutamine echocardiogram predicts low risk of cardiac death (on the order of 1% per year), this risk increases with the extent of abnormal wall motion at rest and stress.

Aged↗

Does renal failure cause an atherosclerotic milieu in patients with end-stage renal disease?

PURPOSE: Atherosclerotic vascular disease is the main cause of morbidity and mortality in patients with end-stage renal disease, but the independent contribution of renal failure rather than associated risk factors is unclear. We sought to examine the relative contribution of these factors to the severity of atherosclerosis by measuring intima-medial thickness and brachial artery reactivity in uremic patients and controls. SUBJECTS AND METHODS: Cardiovascular risk factors, including lipid and homocysteine levels, were evaluated in 213 patients (69 on hemodialysis, 60 on peritoneal dialysis, and 82 nonuremic controls). High-resolution B-mode ultrasonography with automated off-line analysis was used to measure the intima-medial thickness in the common carotid artery and to measure the lumen diameter of the brachial artery at rest, during reactive hyperemia, and after sublingual nitroglycerine. The correlations of risk factors with intima-medial thickness and brachial reactivity were examined using a general linear regression model. RESULTS: Patients with renal failure had a greater mean (+/- SEM) maximum intima-medial thickness than controls (0.83 +/- 0.02 mm versus 0.70 +/- 0.02 mm, P < 0.05), but the brachial artery response to reactive hyperemia was not significantly different between the renal failure patients and the control group (4.7% +/- 6.1% versus 6.1% +/- 8.6% dilatation, P > 0.05). The uremic state was an independent predictor of intima-medial thickness (r2 = 0.16, P < 0.001) but not of brachial artery reactivity (P = 0.99). CONCLUSION: The atherosclerotic burden in patients with renal failure, as indicated by an increased intima-medial thickness, may reflect effects of uremia that are independent of cardiovascular risk factors.

Adult↗

Automated edge-detection technique for measurement of brachial artery reactivity: a comparison of concordance with manual measurements.

Concerns have been raised about the reproducibility of brachial artery reactivity (BAR), because subjective decisions regarding the location of interfaces may influence the measurement of very small changes in lumen diameter. We studied 120 consecutive patients with BAR to address if an automated technique could be applied, and if experience influenced reproducibility between two observers, one experienced and one inexperienced. Digital cineloops were measured automatically, using software that measures the leading edge of the endothelium and tracks this in sequential frames and also manually, where a set of three point-to-point measurements were averaged. There was a high correlation between automated and manual techniques for both observers, although less variability was present with expert readers. The limits of agreement overall for interobserver concordance were 0.13 +/- 0.65 mm for the manual and 0.03 +/- 0.74 mm for the automated measurement. For intraobserver concordance, the limits of agreement were - 0.07 +/- 0.38 mm for observer 1 and - 0.16 +/- 0.55 mm for observer 2. We concluded that BAR measurements were highly concordant between observers, although more concordant using the automated method, and that experience does affect concordance. Care must be taken to ensure that the same segments are measured between observers and serially.

Automation↗

Noninvasive tests of vascular function and structure: why and how to perform them.

BACKGROUND: Early atherosclerosis involves the endothelium of many arteries. Information about peripheral arterial anatomy and function derived from vascular imaging studies such as brachial artery reactivity (BAR) and carotid intima media thickness (IMT) may be pertinent to the coronary circulation. The prevention and early treatment of atherosclerosis is gaining more attention, and these tests might be used as indications or perhaps guides to the effectiveness of therapy, but their application in clinical practice has been limited. This review seeks to define the anatomy and pathophysiology underlying these investigations, their methodology, the significance of their findings, and the issues that must be resolved before their application. METHODS: The literature on BAR and IMT is extensively reviewed, especially in relation to clinical use. RESULTS: Abnormal flow-mediated dilation is present in atherosclerotic vessels, is associated with cardiovascular risk factors, and may be a marker of preclinical disease. Treatment of known atherosclerotic risk factors has been shown to improve flow-mediated dilation, and some data suggest that vascular responsiveness is related to outcome. Carotid IMT is associated with cardiovascular risk factors, and increased levels can predict myocardial infarction and stroke. Aggressive risk factor management can decrease IMT. CONCLUSIONS: BAR and IMT are functional and structural markers of the atherosclerotic process. The clinical use of BAR has been limited by varying reproducibility and the influence by exogenous factors, but IMT exhibits less variability. A desirable next step in the development of BAR and IMT as useful clinical tools would be to show an association of improvement in response to treatment with improvement in prognosis.

Arteries↗

Accuracy and cost- and time-effectiveness of digital clip versus videotape interpretation of echocardiograms in patients with valvular disease.

BACKGROUND: Although digital and videotaped images are known to be comparable for the evaluation of left ventricular function, their relative accuracy for assessment of more complex anatomy is unclear. We sought to compare reading time, storage costs, and concordance of video and digital interpretations across multiple observers and sites. METHODS: One hundred one patients with valvular (90 mitral, 48 aortic, 80 tricuspid) disease were selected prospectively, and studies were stored according to video and standardized digital protocols. The same reviewer interpreted video and digital images independently and at different times with the use of a standard report form to evaluate 40 items (e.g., severity of stenosis or regurgitation, leaflet thickening, and calcification) as normal or mildly, moderately, or severely abnormal. Concordance between modalities was expressed at kappa. Major discordance (difference of >1 level of severity) was ascribed to the modality that gave the lesser severity. CD-ROM was used to store digital data (20:1 lossy compression), and super-VHS videotape was used to store video data. The reading time and storage costs for each modality were compared. RESULTS: Measured parameters were highly concordant (ejection fraction was 52% +/- 13% by both). Major discordance was rare, and lesser values were reported with digital rather than video interpretation in the categories of aortic and mitral valve thickening (1% to 2%) and severity of mitral regurgitation (2%). Digital reading time was 6.8 +/- 2.4 minutes, 38% shorter than with video (11.0 +/- 3.0, range 8 to 22 minutes, P <.001). Compressed digital studies had an average size of 60 +/- 14 megabytes (range 26 to 96 megabytes). Storage cost for video was A$0.62 per patient (18 studies per tape, total cost A$11.20), compared with A$0.31 per patient for digital storage (8 studies per CD-ROM, total cost A$2.50). CONCLUSION: Digital and video interpretation were highly concordant; in the few cases of major discordance, the digital scores were lower, perhaps reflecting undersampling. Use of additional views and longer clips may be indicated to minimize discordance with video in patients with complex problems. Digital interpretation offers a significant reduction in reading times and the cost of archiving.

CD-ROM↗

Effect of power Doppler and digital subtraction techniques on the comparison of myocardial contrast echocardiography with SPECT.

OBJECTIVE: To compare the accuracy and feasibility of harmonic power Doppler and digitally subtracted colour coded grey scale imaging for the assessment of perfusion defect severity by single photon emission computed tomography (SPECT) in an unselected group of patients. DESIGN: Cohort study. SETTING: Regional cardiothoracic unit. PATIENTS: 49 patients (mean (SD) age 61 (11) years; 27 women, 22 men) with known or suspected coronary artery disease were studied with simultaneous myocardial contrast echo (MCE) and SPECT after standard dipyridamole stress. MAIN OUTCOME MEASURES: Regional myocardial perfusion by SPECT, performed with (99m)Tc tetrafosmin, scored qualitatively and also quantitated as per cent maximum activity. RESULTS: Normal perfusion was identified by SPECT in 225 of 270 segments (83%). Contrast echo images were interpretable in 92% of patients. The proportion of normal MCE by grey scale, subtracted, and power Doppler techniques were respectively 76%, 74%, and 88% (p < 0.05) at > 80% of maximum counts, compared with 65%, 69%, and 61% at < 60% of maximum counts. For each technique, specificity was lowest in the lateral wall, although power Doppler was the least affected. Grey scale and subtraction techniques were least accurate in the septal wall, but power Doppler showed particular problems in the apex. On a per patient analysis, the sensitivity was 67%, 75%, and 83% for detection of coronary artery disease using grey scale, colour coded, and power Doppler, respectively, with a significant difference between power Doppler and grey scale only (p < 0.05). Specificity was also the highest for power Doppler, at 55%, but not significantly different from subtracted colour coded images. CONCLUSIONS: Myocardial contrast echo using harmonic power Doppler has greater accuracy than with grey scale imaging and digital subtraction. However, power Doppler appears to be less sensitive for mild perfusion defects.

Aged↗

Telehealth and the diagnosis and management of cardiac disease.

The financial and personal burden of chronic cardiac disease is high. Costs are likely to increase over the next few decades. Promising applications of telehealth have appeared in the diagnosis and management of cardiac disease and there are indications that telehealth services can improve the management of chronic cardiac disease as well as extend services to remote and rural populations. Telehealth has been applied to the capture of symptoms of cardiac disease with electrocardiography and echocardiography, to the management and rehabilitation of recently discharged patients, and in peer-to-peer consultation where remote expertise can facilitate diagnosis. Telehealth promises cost reductions in service delivery, although there is a need for properly controlled cost-effectiveness trials to underpin telehealth with a firm evidence base.

Chronic Disease↗

Assessment of regional long-axis function during dobutamine echocardiography.

Echocardiographic analysis of regional left ventricular function is based upon the assessment of radial motion. Long-axis motion is an important contributor to overall function, but has been difficult to evaluate clinically until the recent development of tissue Doppler techniques. We sought to compare the standard visual assessment of radial motion with quantitative tissue Doppler measurement of peak systolic velocity, timing and strain rate (SRI) in 104 patients with known or suspected coronary artery disease undergoing dobutamine stress echocardiography (DbE). A standard DbE protocol was used with colour tissue Doppler images acquired in digital ciné-loop format. Peak systolic velocity (PSV), time to peak velocity (TPV) and SRI were assessed off-line by an independent operator. Wall motion was assessed by an experienced reader. Mean PSV, TPV and SRI values were compared with wall motion and the presence of coronary artery disease by angiography. A further analysis included assessing the extent of jeopardized myocardium by comparing average values of PSV, TPV and SRI against the previously validated angiographic score. Segments identified as having normal and abnormal radial wall motion showed significant differences in mean PSV (7.9 +/- 3.8 and 5.9 +/- 3.3 cm/s respectively; P < 0.001), TPV (84 +/- 40 and 95 +/- 48 ms respectively; P = 0.005) and SRI (-1.45 +/- 0.5 and -1.1 +/- 0.9 s(-1) respectively; P < 0.001). The presence of a stenosed subtending coronary artery was also associated with significant differences from normally perfused segments for mean PSV (8.1+/-3.4 compared with 5.7+/-3.7 cm/s; P < 0.001), TPV (78 +/- 50 compared with 92 +/- 45 ms; P < 0.001) and SRI (-1.35 +/- 0.5 compared with -1.20 +/- 0.4 s(-1); P = 0.05). PSV, TPV and SRI also varied significantly according to the extent of jeopardized myocardium within a vascular territory. These results suggest that peak systolic velocity, timing of contraction and SRI reflect the underlying physiological characteristics of the regional myocardium during DbE, and may potentially allow objective analysis of wall motion.

Adrenergic beta-Agonists↗

Total arterial compliance is a major determinant of peak oxygen uptake.

Total arterial compliance (TAC, defined as dV/dP), is a major component of the arterial system. A decreased TAC increases left ventricular load and has a detrimental effect on coronary perfusion. We sought to assess the influence of TAC on the functional reserve (VO2max). Fourteen patients (mean age 64 +/- 14y) with known or suspected coronary artery disease and eleven controls (34 +/- 5y) underwent supine bicycle exercise echocardiography. Audio Doppler signal output of the echocardiographic machine was digitized with a customized hardware and software interface simultaneously with carotid tonometry and ECG. TAC at rest was calculated by the pulse pressure method (PPM). By step-wise forward multivariate analysis, independent predictors of VO2max were patient versus control status, peak exercise cardiac output and TAC. The described PC-based acquisition system for tonometry and Doppler signals permits the assessment of ventricular function and arterial biomechanics.

Adult↗

Usefulness of impaired chronotropic response to exercise as a predictor of mortality, independent of the severity of coronary artery disease.

Chronotropic incompetence, or an attenuated heart rate response to exercise, has been shown to be associated with an adverse outcome. It is not known whether chronotropic incompetence predicts all-cause mortality independent of angiographic severity of coronary artery disease (CAD). Study subjects included consecutive patients who underwent first-time, symptom-limited exercise treadmill testing and coronary angiography within 90 days; no patient was taking beta blockers or had a history of heart failure, valve disease, or prior revascularization. Chronotropic response was measured in 2 ways: (1) failure to reach 85% of the age-predicted maximum heart rate, and (2) a low chronotropic index, a measure of exercise heart rate response that accounts for effects of age, physical fitness, and resting heart rate. Angiographic severity of CAD was assessed using the Duke Prognostic Weight Score, with a score > or = 42 considered to be indicative of severe CAD. Among 384 eligible patients, failure to reach 85% of the age-predicted maximum heart rate occurred in 61 (16%) and a low chronotropic index was noted in 133 (35%). Severe CAD was present in 63 (16%). During 6 years of follow-up there were 56 deaths. Mortality was predicted by failure to reach target heart rate (RR 1.85, 95% confidence interval [CI] 1.01 to 3.39, chi-square = 4, p = 0.05), by severe CAD (RR 2.21, 95% CI 1.24 to 3.95, chi-square = 8, p = 0.007), and, most strongly, by a low chronotropic index (RR 2.72, 95% CI 1.60 to 4.61, chi-square = 15, p = 0.0002). In a multivariable model, low chronotropic index remained predictive of death (adjusted RR 2.22, 95% CI 1.29 to 3.82, p = 0.004), whereas severe CAD no longer predicted death (adjusted RR 1.27, 95% CI 0.70 to 2.31, p > 0.4). Thus, chronotropic incompetence is a strong and independent predictor of death, even after accounting for the angiographic severity of CAD.

Confidence Intervals↗

Noninvasive strategies for the estimation of cardiac risk in stable chest pain patients. The Economics of Noninvasive Diagnosis (END) Study Group.

Effective allocation of medical resources in stable chest pain patients requires the accurate diagnosis of coronary artery disease and the stratification of future cardiac risk. We studied the relative predictive value for cardiac death of 3 commonly applied noninvasive strategies, clinical assessment, stress electrocardiography, and myocardial perfusion tomography, in a large, multicenter population of stable angina patients. The multicenter observational series comprised 7 community and academic medical centers and 8,411 stable chest pain patients. All patients underwent pretest clinical screening followed by stress (exercise 84% or pharmacologic 16%) electrocardiography and myocardial perfusion tomography. Risk-adjusted multivariable Cox proportional hazards models were developed to predict cardiac death. Kaplan-Meier rates of time to cardiac catheterization were also computed. Cardiac mortality was 3% during the 2.5 +/- 1.5 years of follow-up. The number of infarcted vascular territories and pretest clinical risk factors were strong predictors of cardiac mortality, whereas the number of ischemic vascular territories gained increasing importance when determining post-test resource use requirements (i.e., the decision to perform cardiac catheterization). Exertional ST-segment depression in a population with a high frequency of electrocardiographic abnormalities at rest was not a significant differentiator of cardiac death risk. Stable chest pain patients are accurately identified as being at high risk for near-term cardiac events by both physicians' screening clinical evaluation and by the results of stress myocardial perfusion imaging. Disease management strategies for stable chest pain patients aimed at risk reduction should incorporate knowledge of relevant end points in treatment and guideline development.

Aged↗

Correlation of myocardial Doppler velocity response to exercise with independent evidence of myocardial ischemia by dual-isotope single-photon emission computed tomography.

Myocardial Doppler velocity (MDV) imaging may provide an objective correlate of ischemia, thereby reducing the expertise needed for interpreting stress echocardiography and improving its reproducibility. This study sought to independently validate the results of exercise MDV imaging with single-photon emission computed tomography (SPECT) perfusion imaging in 116 patients (age 60+/-12 years, 28 women) referred for exercise SPECT for diagnostic or prognostic assessment of coronary artery disease. Two-dimensional echocardiography was performed with simultaneous color MDV data acquisition before and after exercise treadmill testing. MDV data were processed off-line to display myocardial velocity profiles in each segment at rest and peak exercise. SPECT was analyzed using a 16-segment model and segments were classified as normal or showing resting or stress defects. Resting defects within segments showing normal function were attributed to attenuation. Color MDV data were compared with SPECT results, and a multivariate analysis (including exercise and SPECT results) was performed to identify the determinants of the exercise MDV response. Patients exercised maximally (peak rate-pressure product 27.6+/-6.1x10(3), and SPECT was abnormal in 33 patients. Of the 1,333 left ventricular segments evaluable by SPECT and MDV, 1,217 segments were classified as normal, 43 showed a stress defect, and 73 a rest defect. Segmental comparison of thallium findings and MDV showed that segments with a rest defect had a lower velocity at rest and stress than normal segments (p<0.001). Segments with a stress defect had a marked reduction in peak exercise velocity and less increment in velocity than normal segments. Heart rate, functional capacity, and presence of abnormally perfused segments were independent predictors of myocardial velocity at peak exercise. Thus, color MDV correlates with independent evidence of ischemia, although it is also influenced by exercise capacity and left ventricular function. This technique may permit a feasible approach to quantitation of exercise echocardiography.

Blood Flow Velocity↗

Anatomical M-mode: A novel technique for the quantitative evaluation of regional wall motion analysis during dobutamine echocardiography.

Recognition of abnormal wall motion during dobutamine echocardiography requires an expert observer. Anatomical M-mode echocardiography may offer a novel quantitative approach to interpretation, amenable to less expert readers. We studied the application of this new modality to 124 patients (80 with known coronary anatomy and 44 patients at low probability of coronary disease) who underwent dobutamine echocardiography, using a standard protocol. Wall motion was interpreted by an experienced reader, using digitally stored 2-dimensional echocardiographic images at rest and peak stress. Percentage of systolic thickening was measured offline using anatomical M-mode echocardiography in the basal and mid segments at rest and peak dose, and compared with wall motion scores and coronary angiography. Of 729 segments, wall motion was identified as normal in 449, ischemic or viable in 171 and showed resting WM abnormalities only in 109 segments. After exclusion of the apex, anatomical M-mode measurements were feasible in 729 of 960 possible basal- and mid-zone segments (76%). Measurement of systolic thickening at peak dose was reproducible within (r2 = 0.83) and between observers (r2 = 0.93). Systolic thickening was significantly greater in segments with normal wall motion (37 +/- 2%) compared with ischemic or viable segments (30 +/- 2%, p < 0.001), and scar segments (23 +/- 3%, p < 0.001). There was an increment of thickening from rest to stress in normal and viable segments, no change in scar, and a decrement in ischemic segments. Significant coronary artery disease (defined by stenoses >70% diameter) was present in 59 patients. Systolic thickening showed significant variation between segments interpreted by wall motion scoring and angiography as true and false positive and true and false negative (p < 0.05). Measurement of systolic thickening using anatomical M-mode echocardiography offers an objective method to quantify systolic thickening at dobutamine echocardiography but has limited clinical feasibility.

Aged↗