Development of a 1.0 T MR microscope using a Nd-Fe-B permanent magnet.

A compact 1.0 T MR microscope was developed using a permanent magnet made of high performance Nd-Fe-B magnetic material and a compact MRI console (54 cm (W) x 77 cm (H) x 60 cm (D), 80 kg weight). Since the magnetic field of the permanent magnet had a large temperature coefficient (-1200 ppm/deg), an internal NMR locking technique was developed for the imaging sequences. The performance of the system was evaluated using several biological specimens. As a result, good SNR 3D images at (50 microm)(3)-(200 microm)(3) voxel dimensions were obtained in practical imaging times (0.5-7.5 hours). Thus we have concluded that the permanent-magnet compact MR microscope has great promise as a research or analytical tool.

Animals↗

Architecture of baked breads depicted by a magnetic resonance imaging.

The architecture of baked breads made of fresh dough and frozen dough was depicted by magnetic resonance imaging (MRI). Pieces of bread (16 mm cubic cakes) were soaked in organic solvents containing various concentrations of heavy metals (Cu(2+), Co(2+) and Fe(3+)) and images of the grain structure of the breads were obtained. Of the organic solvents tested, acetone was preferable because of its single peak that prevents chemical shift effects on images, the retention of the bread structure, and the solubility of heavy metals. The heavy metals, especially Fe(3+), shortened the overly long relaxation times of acetone to practical lengths for imaging and stained the materials to provide high contrasts. The images obtained in acetone with 8 mM Fe(3+) were suitable for analyzing crumb grain structures. The bread of fresh dough showed a uniform distribution of pores of various sizes made of thin gluten sheets, whereas the pores in the bread of frozen dough were less, prominently large, non-uniformly distributed, and made of thick gluten sheets.

Bread↗

[Application of a new MR microscope using an independent console system (MRMICS) for biological tissues in vitro].

We studied microscopic MR images of the normal appendix in vitro using a new MR microscope system: MR Microscope using an Independent Console System (MRMICS). The MRMICS was placed in the clinical MR room, and the probe box was fixed on the bed of the 1.5 T clinical MR machine. T1-, T2-, and proton density-weighted images were obtained using spin echo sequences with an in-plane pixel size of 100 x 100 microns. Zonal structures of the appendix were clearly demonstrated with different contrast by different sequences. Therefore, the MRMICS is a useful add-on system for investigating microscopic MR images of biological tissues in vitro.

Appendix↗

Real-time image reconstruction and display system for MRI using a high-speed personal computer.

A real-time NMR image reconstruction and display system was developed using a high-speed personal computer and optimized for the 32-bit multitasking Microsoft Windows 95 operating system. The system was operated at various CPU clock frequencies by changing the motherboard clock frequency and the processor/bus frequency ratio. When the Pentium CPU was used at the 200 MHz clock frequency, the reconstruction time for one 128 x 128 pixel image was 48 ms and that for the image display on the enlarged 256 x 256 pixel window was about 8 ms. NMR imaging experiments were performed with three fast imaging sequences (FLASH, multishot EPI, and one-shot EPI) to demonstrate the ability of the real-time system. It was concluded that in most cases, high-speed PC would be the best choice for the image reconstruction and display system for real-time MRI.

Equipment Design↗