PubMed Health⌕ Search

Biomedical subjects

T Haygood

Publications and source records attributed to T Haygood.

3 recordsLinked to original sources

Electromyography monitoring for percutaneous placement of iliosacral screws.

OBJECTIVE: To report our experience with the use of continuous electromyography (EMG) for placement of iliosacral screws. DATA SOURCES: Concurrently acquired data as well as patient charts, intraoperative EMG records, x-rays, and pelvic computed tomography (CT) scans. DESIGN: The monitored group of twenty-nine patients was studied prospectively. The control group consisted of twenty-two patients studied retrospectively. SETTING: Level One trauma center. METHODS: Continuous electromyograms were recorded for twenty-nine patients and compared with those from a group of twenty-two antecedent patients who were not monitored. The primary parameter of interest of this study was the presence or absence of neurologic change after iliosacral screw placement. This information was obtained prospectively in the study group and by retrospective review in the historical control. RESULTS: Four patients in the control group had postoperative and/or sensory motor changes prompting a postoperative CT scan; in each of these patients, a misdirected screw was identified and subsequently removed in a second procedure. There were no neurologic changes subsequent to placement in the twenty-nine patients who were monitored (7.5 percent versus 0 percent; p = 0.029, Fisher's exact test). All monitored patients had postoperative CT scans and showed the screw in a safe position with no significant violations of the S1 tunnel. CONCLUSION: Continuous EMG monitoring during iliosacral screw placement may be a useful neuroprotective tool.

Adolescent↗

Roentgenographic assessment of acromial morphologic condition in rotator cuff impingement syndrome.

Patients with an isolated diagnosis of rotator cuff impingement syndrome were prospectively entered into the study. Each of the 23 subjects was refractory to conservative therapy, had preoperative roentgenograms, and underwent an open acromioplasty. The roentgenograms included anteroposterior, axillary, 30 degrees caudal tilt, and supraspinatus outlet views. The roentgenograms were measured by four independent readers. The separate views were then scored for reliability, and the correlation of the measurements with intraoperative acromial measurements was assessed. Interobserver reliability was highest for the caudal tilt view (0.84) and lowest for the axillary view (0.09). The supraspinatus and caudal tilt views correlated significantly with distinct intraoperative measurements of acromial spur size. We continue to advocate the evaluation of both views for preoperative assessment of the acromial spur in the rotator cuff impingement syndrome.

Acromion↗