[Evaluation of an electromagnetic virtual target system (CT-guide) for CT-guided interventions].

PURPOSE: Evaluation of the accuracy of a new electromagnetic target system for interventional CT-guided procedures with virtual navigation in a previously acquired helical CT. MATERIAL AND METHODS: The new target system CT-Guide 1010 (Ultraguide, Tirat Hacarmel, Israel) for CT-guided interventions was adapted to the video signal of the Somatom Plus 4 and Volume Zoom (Siemens, Erlangen, Germany). A helical CT-dataset including skin-based sensor cubes was transferred to the integrated navigation system inside the scanner room. 50 image-guided interventions and biopsies were performed outside the gantry using virtual navigation to reach the lesion. The accuracy of the procedures was evaluated using documentation of the needle tip with CT-fluoroscopy, results of histology, and follow-up. RESULTS: The deviation between planned and documented needle tip was 2.2 +/- 2.1 mm in 50 procedures. Time between the end of planning-CT and needle positioning using the system was 13 minutes. There were no complications due to the use of the system. CONCLUSION: The CT-Guide allows for virtual real-time navigation with high accuracy. Advantages are the free needle angulation without gantry tilt, use of optimal CT perfusion phase for virtual navigation, and reduction of radiation exposure to the patient and interventionalist.

Adult↗

New contrast agents for imaging the liver.

The contrast agents suited for hepatic imaging can be divided into nonspecific, extracellular space- (ECS) directed, reticuloendothelial system- (RES) selective, and hepatocyte-selective compounds. There is a wide variation in regard to biodistribution, pharmacokinetics, contrast behavior, and tissue specificity. The ECS contrast agents provide information on vascularization and perfusion similar to that of X-ray contrast agents. The RES- and hepatocyte-specific contrast agents offer more "functional" information that may enhance tissue characterization; however, the biology of the different hepatocellular and nonhepatocellular tumors is limiting the diagnostic efficacy of the tissue-specific compounds in many respects.

Animals↗

[MR angiography of the supraaortic vessels].

PURPOSE: To compare high resolution contrast-enhanced MR angiography (MRA) and digital subtraction angiography (DSA) in the assessment of supraaortic vessel stenosis. METHODS: 14 patients with suspicion of cerebrovascular disease or upper limb ischemia underwent selective DSA and high resolution contrast enhanced MRA employing a new Panoramic-Array coil. Stenosis assessment in comparison to DSA followed NASCET criteria. Additionally signal-/noise ratios (SNR) were evaluated to assess contrast enhancement. RESULTS: Diagnostic image quality was achieved in all patients. Sensitivity and specificity for assessing high-grade stenosis of the supraaortic vessels were 100% and 96% respectively. In the assessment of high-grade common or internal carotid artery stenosis sensitivity and specificity was 100%. CONCLUSION: High resolution contrast enhanced supraaortic MRA combined with new coil systems allow for a reliable assessment of stenoses along the whole vessel course including the aortic arch. Previous stent procedures limit its use in postinterventional follow-up.

Adult↗

[Stenoses and occlusions of the supraaortic vessels--the interdisciplinary interventional treatment of patients with an increased surgical risk].

PURPOSE: The value of elective PTA in stenoses of the supraaortic vessels and especially of the carotid artery is still under discussion. Stenoses after surgical and/or radiation therapy and a high cardio-vascular risk for a surgical procedure, however, justify minimal-invasive techniques. MATERIAL AND METHODS: In 31 patients with 24 symptomatic and 7 asymptomatic stenoses of the supraaortic arteries (3 Acc, 19 Aci, 5 Ascl, 4 Tr.brc, 2 Aax) minimal-invasive angioplasty and stent-placement was performed. The rationale for the interventional procedure was an elevated medical or technical risk of the respective surgical procedure. All procedures were performed using a coaxial technique with a guiding catheter. An open vascular access was necessary in 7 cases due to an unfavorable anatomical situation. RESULTS: The technical success rate was 100%. Peri-interventionally, a TIA occurred in 2 patients (1 spontaneous relieve, 1 complete remission after rt-PA lysis therapy). During the mean follow-up period of 13 months 3 patients died due to non-cerebrovascular reasons. In 2 patients a moderate restenosis, in 1 a high-grade stenosis, and in 1 and complete occlusion occurred without symptoms. After one year of follow-up, all treated stenoses were patent with a restenosis rate of 10.7% without further neurological symptoms. CONCLUSION: Interventional angioplasty with stent-placement of the supraaortic arteries is a safe and effective alternative in patients are at high risk for classical surgical procedures.

Adult↗

Effect of superparamagnetic iron oxide on bone marrow.

The goal of this study was to compare the effects of SPIO particles on the signal intensity of the bone marrow of the vertebra spine in patients with and without liver cirrhosis. Forty-eight patients with normal liver tissue and 56 patients with liver cirrhosis were examined before and after intravenous SPIO administration, using a 1.5-T system (Magnetom Vision, Siemens, Erlangen, Germany) with a semiflexible cp-array coil. Three different pulse sequences were applied: a T1-weighted gradient-echo sequence, a T2-weighted fast spin-echo sequence with spectral fat suppression and a T2*-weighted gradient-echo sequence. The signal-to-noise ratio (SNR) of the liver, vertebra bone and paraspinal muscle were obtained. The SNR value change in each patient group and the SNR value difference between the two groups were evaluated. For assessment of statistical significance, Student's t-test with a level of p < 0.05 was applied. No significant differences in the SNR values of the liver and bone marrow between the two groups could be seen with any of the three sequences precontrast. Using the T1-weighted gradient-echo sequence in the noncirrhotic liver group, pre- and postcontrast comparisons of the SNR values of the liver and bone marrow indicated a decrease of approximately -44.3% (p = 0.02) and increase of approximately 15.3% (p = 0.04), respectively. No significant change was seen in the cirrhotic liver group. With the T2-weighted fast spin-echo sequence, a significant decrease of the SNR value of the liver and the bone marrow in both groups was seen. With the T2*-weighted gradient-echo sequence, the signal intensity decrease of the normal liver tissue was approximately -65.6% (p = 0.00), in cirrhotic liver tissue the decrease was -29.9% (p = 0.02). The SNR values of the bone marrow showed a decrease of -27.8% (p = 0.04) in the noncirrhotic liver group, whereas in the cirrhotic liver group it was only -11.3% and statistically not significant. The effect of SPIO particles on the liver and bone marrow is significantly less in patients with liver cirrhosis.

Adult↗

Signal changes in liver and spleen after Endorem administration in patients with and without liver cirrhosis.

The goal of this study was compare the effect of Endorem on the signal intensity of the spleen in patients with normal liver tissue and in patients with liver cirrhosis. Thirty patients with normal liver tissue and 47 with liver cirrhosis were examined before and after i.v. Endorem administration. The patients were examined with a 1.5-T magnet system (Magnetom Vision) using a semiflexible cp-array coil. Three different pulse sequences were used: a T1-weighted gradient-echo sequence, a T2-weighted fast spin-echo sequence with spectral fat suppression, and a T2*-weighted gradient-echo sequence. The signal-to-noise ratios (SNRs) of two areas of the liver and spleen were determined. The mean SNRs of the liver and spleen in patients with and without liver cirrhosis were compared. For assessment of statistical significance, the t-test at a level of P < 0.05 was applied. After i.v. administration of Endorem, no differences were seen with the T1-weighted gradient-echo sequence for the liver and spleen and, with the T2-weighted fast spin-echo sequence, no differences were found for the spleen. Significant differences between both groups were seen for the liver with the T2-weighted fast spin-echo sequence. The SNR in the noncirrhotic liver group was 57.4% lower than the SNR in the cirrhotic liver group. With the T2*-weighted gradient-echo sequence, the SNRs of the liver and spleen in the noncirrhotic liver group, compared with the cirrhotic liver group, were 126.8% and 45.6% less, respectively. The effect of Endorem on the liver in patients with Child C-stage liver cirrhosis was 32.1% less than in patients with Child B-stage liver cirrhosis. Likewise, the Endorem effect on the spleen was 27.1% less in patients with Child C-stage compared with Child B-stage liver cirrhosis. Hepatic and splenic uptake of Endorem is significantly decreased in patients with liver cirrhosis.

Adult↗

Impact of virtual reality imaging on hepatic liver tumor resection: calculation of risk.

The risk involved in partial liver resections depends mainly on tumor localization, invasion of central vascular structures, and parenchymal function. The imaging techniques available today (computed tomography, magnetic resonance imaging) allow us to detect precisely the extent of tumor invasion and their relationship to central vessels. The various three-dimensional reconstruction techniques are helpful with regard to a virtual planning of liver resections. The calculation of remaining liver volumes subsequent to partial hepatectomies are considered to be an essential predictive parameter in terms for the development of postoperative liver failure. In a retrospective and a later consecutive, prospective clinical study we analyzed the postoperative risk in a series of 570 patients. In an univariate analysis 13 of 31 parameters showed significant values. In multivariate analysis only three parameters (partial hepatic resection rate, PHRR), gamma-glutamyltranspeptidase, and prothrombin activity) were independent parameters for predicting liver failure, generating the most significant values for the PHRR. In our experience the most comfortable and precise technique for evaluating PHRR is the b-spline technique.

Female↗

[Effects of biphasic spiral CT, conventional and iron oxide enhanced MRI on therapy and therapy costs in patients with focal liver lesions].

PURPOSE: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. METHODS: In 52 patients with the suspicion of primary or secondary hepatic malignancy, biphasic spiral CT and breath-hold gradient-echo T1- and fast spin-echo T2-weighted MRI pre- and post-iron oxide administration (1.5 T, body-phased-array coil) were compared. The number of hepatic lesions and the related diagnoses resulting from each imaging modality were recorded and statistically correlated to the final diagnoses established by biopsy/OP (34/52), long term follow-up of 12 months (18/52), and a consensus reading of all imaging modalities considering all clinical imaging information. The most likely induced therapy resulting from each imaging test was correlated to the final therapy. Based on data from the hospitals accountants, the therapy-related costs were estimated without hospitalization costs. RESULTS: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needles therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (1 hemangioma, 1 regenerative nodule) all modalities failed, causing unnecessary surgery in one patient. DISCUSSION: In this problem-oriented scenario unenhanced and SPIO-enhanced MRI proved to be superior to CT regarding diagnostic efficacy. The cost-benefit resulted mainly due to preserving patients from unnecessary surgical procedures.

Adenoma, Liver Cell↗

Segmental and subsegmental pulmonary arteries: evaluation with electron-beam versus spiral CT.

PURPOSE: To compare contrast agent-enhanced spiral and electron-beam computed tomography (CT) for the analysis of segmental and subsegmental pulmonary arteries. MATERIALS AND METHODS: CT angiography of the pulmonary arteries was performed in 56 patients to rule out pulmonary embolism. Electron-beam CT was performed in 28 patients. The other 28 patients underwent spiral CT with comparable scanning protocols. The depiction of segmental and subsegmental arteries was analyzed by three independent readers. The contrast enhancement in the main pulmonary artery was measured in each patient. RESULTS: Analysis was performed in 1,120 segmental and 2, 240 subsegmental arteries. One segmental (RA7, P =.010) and two subsegmental (LA7b, P =.029; RA6a+b, P =.038) arteries in paracardiac and basal segments of the lung were depicted significantly better with electron-beam CT. There was no statistically significant difference between electron-beam and spiral CT in the total number of analyzable peripheral arteries depicted. The mean contrast enhancement in the main pulmonary artery was 362 HU in electron-beam CT studies versus 248 HU in spiral CT studies. CONCLUSION: Detailed visualization of peripheral pulmonary arteries is well within the scope of advanced CT techniques. Electron-beam CT has minor advantages in analyzing paracardiac arteries, probably because of reduction of motion artifacts and higher contrast enhancement. Further studies are needed to establish whether electron-beam CT allows a more confident diagnosis of emboli in these vessels.

Adult↗

Dynamic contrast-enhanced MR angiography from the distal aorta to the ankle joint with a step-by-step technique.

OBJECTIVE: The aim of this study was to visualize the arteries from the distal aorta to the ankle joint and to determine the accuracy of MR angiography for detecting stenoses and occlusions. SUBJECTS AND METHODS: Twenty-four patients with peripheral arterial occlusive disease underwent digital subtraction angiography and were examined on a 1.5-T MR scanner. The transit time for contrast material was determined with a test bolus injection. A T1-weighted three-dimensional gradient-echo sequence with short TR and TE was used for a dynamic measurement at the level of the iliac arteries, the upper leg, and the lower leg arteries. For each level a single dose of gadolinium was injected into an antecubital vein with an MR power injector. Maximal-intensity-projection reconstructions were calculated after subtraction of the first measurement at each level. Two experienced MR radiologists who were unaware of the digital subtraction angiography results interactively evaluated both the MIP reconstructions and the single slices on a workstation, first independently and then in a consensus interpretation. RESULTS: With digital subtraction angiography, 80 hemodynamically significant stenoses and 39 occlusions were detected. For the stenoses and occlusions, a sensitivity of 100% was found for MR angiography. The specificity for the assessment of stenoses and occlusions was 98% and 94%, respectively, for the iliac arteries; 98% and 94%, respectively, for the upper leg arteries; and 94% and 95%, respectively, for the lower leg arteries. Most false-positive findings of occlusion were due to metal stents present in the iliac (n = 3) and upper leg (n = 4) arteries. CONCLUSION: The MR imaging technique that we used revealed the arteries from the distal aorta to the ankle and proved to be reliable at showing arterial stenoses and occlusions.

Aged↗

[Diagnosis and staging of liver metastases with imaging methods].

Liver metastases are much more common than primary hepatic malignancies and may occur in up to 80% of patients with extrahepatic malignancies. To optimize the patient's management, precise detection or exclusion of liver metastases, as well as assessment of their number and extent, is indispensable. For imaging of liver metastases, ultrasound, computed tomography (CT), magnetic resonance imaging (MRI), scintigraphy, and angiography can be utilized. All these methods have been technically improved with benefits for diagnostic utility. Biphasic contrast-enhanced spiral CT (SCT) and MRI with modern pulse sequences and tissue-specific contrast agents are superior to other imaging modalities in terms of diagnostic efficacy and reproducibility of results. With SCT and MRI sensitivities and specificities in the diagnosis of focal hepatic disease are in the range of 80-95%. Moreover, their non-invasiveness is a strong advantage. The diagnostic strategy in the assessment of liver metastases has to take into account both the strengths and limitations of the respective method. Additionally, the clinical situation of a particular patient has to be considered, and conclusive diagnostic results have to be achieved in a short time in order to ensure a favourable cost-effectiveness relation.

Colorectal Neoplasms↗

[Computed tomography of the abdomen with multidetector-array CT].

BACKGROUND: The advent of multidetector CT (MDCT) constitutes a quantum leap creating a wealth of new opportunities in medical imaging. However, while the basic principles of spiral CT still apply, we are now challenged to rethink our strategies in planning a CT study to take full advantage of the increased capabilities of MDCT. MATERIALS AND METHODS: We report here our preliminary experiences with MDCT for abdominal CT imaging within a 5-month period. During this time, suitable protocols for investigation of the abdomen using MDCT were developed. The capabilities of MDCT allow for tailoring dedicated CT protocols for routine applications as well as for biphasic liver studies and CT angiography of the aorta and abdominal vessels. RESULTS: The speed of MDCT can either be used to reduce the time needed to cover a given volume, or to use narrower beam collimations to increase the resolution of detail along the z-axis and reduce volume averaging. Higher scan speed allows reduction of the amount of contrast material in vascular applications and suppression of motion artifacts. Higher spatial resolution with thinner collimations reduces volume averaging and improves the detection of small hepatic and pancreatic lesions. Detailed analysis of vascular structures and high-quality three-dimensional reformations become feasible. New problems arise from the large amount of data generated by MDCT. CONCLUSIONS: MDCT offers a wealth of new opportunities that help us to come to a fast and accurate diagnosis in suspected abdominal disease. Traditional indications for performing CT are reemphasized and new clinical applications can be exploited.

Abdomen↗

[New techniques and pulse sequences in MRI of the liver].

PURPOSE: The MRI techniques which have contributed to increasing utilization of MRI for abdominal imaging are described and recent advances addressed. METHODS: For breath-hold examinations of the abdomen, two basic techniques are required: array coil technology and fast and ultrafast pulse sequences providing T1 and T2 contrast. RESULTS: Circular polarized array coils render high signal-to-noise ratios (SNR) within large imaging volumes. With fast gradient-echo sequences the liver can be scanned with or without fat saturation within one breath-hold. When adequate parameters are selected, T2-weighted fast (turbo) spin-echo sequences allow high contrast between normal liver tissue and focal liver lesions, even if breath-hold acquisition is applied. Moreover, good soft tissue contrast can also be achieved with ultrafast single-shot sequences. Based on this sequence type, MRCP with a 512 matrix could be performed. The "TRUE FISP" allows for high resolution visualisation of vessels without contrast media. Three-dimensional T1-weighted sequences allow for scanning the upper abdomen with a slice thickness of 3 mm within one breath-hold. Diffusion-weighted sequences contribute to the characterisation of focal liver lesions. DISCUSSION: Modern MRI technology including phase-array coils and high-performance gradient systems made it possible to perform all examinations in breath-hold techniques, reducing motion artifacts.

Humans↗

[Comparison of dual-phase helical CT with native and ferum oxide-enhanced magnetic resonance imaging in detection and characterization of focal liver lesions].

PURPOSE: Evaluation of the diagnostic efficacy of contrast-enhanced, dual-phase spiral CT and MRI before and after administration of SPIO particles in focal hepatic disease with previously uncertain diagnosis. MATERIAL AND METHODS: In 46 patients in whom primary or secondary hepatic malignancy was suspected, dual-phase spiral CECT and breath-held T1-weighted gradient-echo and T2-weighted fast spin-echo MRI (1.5 T, body-phased-array coil) before and after SPIO administration were compared. The indications for the subsequent MRI studies were based on ambiguous findings on CECT. The number of hepatic lesions, the overall lesion detection and characterization was evaluated by consensus and compared to the gold standard (histological proof in 30/46 of the cases, long-term follow-up in 16/46 of the cases). RESULTS: In 34 of 46 cases the correct diagnoses were established by CECT (sensitivity 96%, specificity 48%) revealing significantly less lesions than MRI. Unenhanced MRI had sensitivity of 93% and specificity of 71%, whereas SPIO-enhanced MRI had sensitivity of 97% and specificity of 88%. The differences between the modalities were even more pronounced in the detection of lesions smaller than 10 mm with SPIO-MRI as the most sensitive method. CONCLUSIONS: In this problem-oriented scenario, SPIO-enhanced MRI was superior to spiral CT and unenhanced MRI regarding the diagnostic efficacy in the pre-operative work-up of focal liver lesions. SPIO-enhanced MRI can be recommended as a problem-solving tool for the clinical routine.

Adult↗

[Percutaneous interventional radiologic implantation of intravenous port-catheter systems].

PURPOSE: Percutaneous interventional radiologic and surgical techniques of port-catheter implantation are described and compared with regard to the technical procedure and results. MATERIALS AND METHODS: In 53 patients with various malignancies interventional radiologic implantation of port-catheter systems into the subclavian vein was performed to provide long-term intravenous access for chemotherapy. The technical procedure, operation time, complication rates and long-term patency were compared with those of surgically implanted systems. RESULTS: Implantation was successful in all cases. Mean operation time was 36 min (range 20-55 min). Mean function time was 189 days (range 7-518). Primary patency rate was 92.5% with a total complication rate of 15% (8/53). In three patients (5.7%) pneumothorax was observed but did not require further treatment. In two cases (3.8%) local infection occurred, and in one patient (1.8%) a non-complicated wound dehiscence. In 12/53 patients (22.6%) the system was withdrawn. Among these, withdrawal was due to complications in 4/53 (7.6%) cases. CONCLUSIONS: Interventional radiologic implantation of long-term intravenous port-catheter systems is comparable to surgical placement with regard to both complication rate and long-term patency.

Adult↗

[Evaluation of right heart load with spiral CT in patients with acute lung embolism].

PURPOSE: Purpose of this study was to evaluate whether spiral-CT allows judgment of right ventricular failure in patients with acute pulmonary embolism. MATERIALS AND METHODS: 61 patients underwent spiral-CT due to suspicion of acute pulmonary embolism. Patients with pulmonary embolism were divided into subpopulations according to the severity of pulmonary embolism in the CT scan. Cardiac measurements were performed on axial spiral-CT images and compared to those of patients without suspicion of pulmonary embolism or cardiac diseases. RESULTS: In 30 patients spiral-CT revealed acute pulmonary embolism. Significant differences in cardiac measurements in patients with severe and less severe pulmonary embolism were found on comparing the following dimensions: left ventricular width (p = 0.0003), left (p = 0.008) and right (p = 0.009) ventricular cross-sectional area, proportion of right to left ventricular width (p = 0.0003) and proportion of right to left ventricular cross-sectional area (p = 0.0001). The proportion of the cross-sectional areas (r = 0.65) and the proportion of the width (r = 0.60) of both ventricles correlated well with the severity of central pulmonary embolism. CONCLUSION: Besides reliable assessment of pulmonary embolism spiral-CT allows the evaluation of cardiac dimensions for judgment of right ventricular failure.

Adult↗