Fluorescence background discrimination by prebleaching.

A number of electrooptical techniques are described that discriminate against background fluorescence in biologic staining, whether from sample background or unbound excess stain. These techniques are based on the fluorescent decay lifetime difference between bound stain and the sample background or between the bound stain its free form. The fluorescence decay lifetimes may be measured either directly or in a combination gated photometry scheme to substantially enhance the sample background contrast. An alternative procedure uses the photochemical bleaching of fluorescent dyes under intense exposure to time discriminate with higher selectivity, sensitivity and in a more convenient fashion between diverse fluorescent molecules.

Antibodies

A generalized machine for automated flow cytology system design.

A general-purpose multiparameter flow cytophotometry system has been developed for use in the desgin of flow cytophotometers to perform specific tasks in automated cytology. Five separate measurement stations spaced along the axis of a capillary tube can be used to make up to eight optical measurements of individual cells flowing through the capillary. The system uses a broad-band arc source and can measure light scattered at various angles, light absorption by cell constituents and/or dyes and fluorescence of cell constituents and/or fluorochromes, excited directly and/or by energy transfer from neighboring molecules. High numerical aperture optics are used to maximize light-gathering capacity and minimize the effects of cell orientation and eccentricity of position in the fluid stream on measurements. A hard-wired preprocessor is used to detect the presence of cells and adjust sampling timing for changes in cell velocity; the electronic system also controls the gain of the detector photomultiplier tubes to compensate for background variations. Data acquistion and analysis are controled by a small general-purpose digital computer. The system has been used to develop a method and apparatus for blood cell counting and classification.

Autoanalysis

Combined blood cell counting and classification with fluorochrome stains and flow instrumentation.

A multiparameter flow cytophotometer was used to count and classify fixed human blood cells fluorochromed with a mixture of ethidium bromide (EB), brilliant sulfaflavine and a blue fluorescent stilbene disulfonic acid derivative (LN). The system measures light scattered by the cells and absorption at 420 nm for all cells. In addition, nuclear EB fluorescence (540 leads to 610 nm) and cytoplasmic fluorescence from LN (366 leads to 470 nm), brilliant sulfaflavine (420 leads to 520 nm) and EB exicted by energy transfer from LN (366 leads to 610 nm) are measured for all nucleated cells. This information is sufficient to perform red and white blood cell counts and to classify leukocytes as lymphocytes, monocytes, basophils, eosinophils or neutrophils. Light scattering and/or nuclear and cytoplasmic fluorescence values may be further analyzed to obtain the ratio of immature to mature neutrophils. Counts produced by the system are in reasonable agreement with those obtained by electronic cells counting and examination of Wright's-stained blood smears; some discrepancies appear to be due to systematic errors in the manual counting method.

Autoanalysis