Paraplegia: prolonged standing using closed-loop functional electrical stimulation and Andrews ankle-foot orthosis.

One T10 paraplegic male (CS) implanted in 1991 with a Nucleus FES-22 stimulator has been able to achieve closed-loop standing for 1 h. The knee angles are monitored by electrogoniometers, resulting in the quadriceps stimulation time being less than 10%. Stance stability is achieved by the Andrews anterior ankle-foot orthosis (AFO). The use of accelerometers for trunk inclination and vertical acceleration during controlled stand-to-sit, diminishes slamming onto the seat. CS does one-handed tasks with objects of 2.2 kg. In another T10 paraplegic male (FR), surface stimulation was applied over 1.5 years to both femoral nerves at the groin for conditioning and prolonged standing. With quadricep conditioning, 55 Nm at 45 degrees of knee flexion is produced. With the AFO and knee monitoring, FR can stand uninterrupted for up to 70 min and perform one-handed tasks. In August 1998, he was implanted with the multifunctional Praxis FES 24-A stimulator for restoration of limb movements, bladder and bowel function, and pressure sore prevention.

Acceleration↗

Paraplegia: prolonged closed-loop standing with implanted nucleus FES-22 stimulator and Andrews' foot-ankle orthosis.

Our object is to develop a reliable, implantable and closed-loop functional electrical stimulator (FES) hybrid system for safe prolonged standing in paraplegic individuals. Open-loop FES systems rapidly induce muscle fatigue that limits paraplegic standing to less than 20 and typically 10 min. Since December 1991, a paraplegic male (CS: 23 years old, T10 level, Asia: A) has been implanted with the first Nucleus FES-22 channel stimulating system (Cochlear Ltd., Lane Cove, N.S.W., Australia). Epineural platinum disc electrodes (2.5 mm) were placed on branches of the femoral, gluteal and sciatic nerves, which can be activated to produce controlled lower extremity movements for exercise and standing. No medical complications have occurred during these 5 1/2 years of implantation. The ankles are stabilized with Andrews' ankle-foot braces, the knees are free to flex. With bilateral knee goniometers fitted to sense a 10 degrees angle flexion, this hybrid closed-loop stimulation system allows the patient to achieve safe uninterrupted standing for over 60 min. The stimulator has needed to be activated 'on' for 8% (range: 3-17%) of the standing times, preventing muscle fatigue, with little or no changes found in the vital signs. The patient can manipulate and transfer objects at arm length up to 2.2 kg with good stability. New, less obstrusive sensors are currently being tested for a safer and more reliable closed-loop system.

Adult↗