PubMed HealthSearch

Biomedical subjects

T How

Publications and source records attributed to T How.

13 recordsLinked to original sources

Vascugraft polyurethane arterial prosthesis as femoro-popliteal and femoro-peroneal bypasses in humans: pathological, structural and chemical analyses of four excised grafts.

Following positive results obtained in in vitro studies and in vivo implantations in animals, a clinical trial using the Vascugraft polyurethane arterial prosthesis as a below-knee substitute was undertaken in 15 patients. Eight grafts became occluded during the first year, and segments from four of them were explanted and made available for pathological, structural and chemical investigations. The implantation periods ranged from 21 to 358 days. Failures were associated with kinking (one case), possible anastomotic mismatch between the graft and the artery (one case), and poor run-off (two cases). No organized collagenous internal encapsulation was noted; however, endothelial-like cells were observed at the anastomotic site of one graft. No significant structural degradation of the prostheses was observed in those grafts implanted for 21, 38 and 46 days. Some deteriorations in the fibrous structure were observed on the external surface of the prosthesis implanted for 358 days. High-resolution carbon C1s analysis by ESCA demonstrated a 60 to 80% decrease in carbonate content on the surface of all explanted prostheses. Chemical analyses of each polyurethane graft by IR, SEC and DSC revealed no significant chemical changes. The clinical performance of the Vascugraft prosthesis for below-knee implantation proved to be no more impressive than that of expanded polytetrafluorethylene, the currently accepted reference. The decision by B. Braun Melsungen AG to end this program is therefore to be regarded as highly professional.

Aged

Interposition vein cuffs.

A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

Anastomosis, Surgical

Polyvinylidene fluoride (PVDF) as a biomaterial: from polymeric raw material to monofilament vascular suture.

This study identified the effects of various manufacturing processes on the crystalline microstructure, mechanical properties, and biocompatibility of a polyvinylidene fluoride (PVDF) suture. To achieve this, changes in the crystalline microstructure and the tensile behavior of PVDF monofilaments were monitored in vitro after different thermal processing, coloration, and sterilization treatments. In addition, the in vivo biocompatibility of the manufactured and sterilized PVDF suture was assessed by using it to anastomose a preclotted polyester vascular prosthesis as a thoracoabdominal bypass in a series of dogs. The tissue response was followed by histologic and scanning electron microscopy over implantation periods ranging from 4 h to 6 months. Differential scanning calorimetry and infrared spectroscopy (FTIR-ATR) showed that thermal processing and the addition of a coloring agent had a direct effect on modifying the crystalline microstructure and hence changing the mechanical properties. For example, thermal processing converted some of the alpha phase into the beta and gamma polymorphs, whereas coloration led only to a major increase in the beta-to-alpha ratio. The tensile properties were found to be optimized when the relative proportion of the beta and gamma phases combined compared to the alpha form gave rise to an FTIR A509/A532 absorption ratio between 4.0 and 4.5. Sterilization was found to cause some modifications to the crystalline microstructure near the surface of the monofilaments, but it did not change their mechanical properties. Pathologic examination of the anastomotic regions after different periods of implantation revealed a minimal cellular response, with no mineralization, intimal hyperplasia, or excessive fibrous tissue reaction. This good biocompatibility, together with other desirable characteristics such as ease of manipulation and satisfactory mechanical strength, makes PVDF an attractive alternative monofilament suture material for cardiovascular surgery.

Animals

Carbodiimide cross-linked gelatin: a new coating for porous polyester arterial prostheses.

The performance of a polyester arterial prosthesis impregnated with gelatin and cross-linked with carbodiimide (Uni-graft) was compared with its porous parent graft (Protegraft) using a canine thoraco-abdominal bypass model. The grafts were investigated in terms of their handling characteristics, imperviousness at implantation, surface thrombogenicity and healing behaviour. Prostheses 30 cm in length were implanted for the following periods: 4, 24 and 48 h, 1, 2 and 4 weeks, 2, 3, 4, 5 and 6 months. Both types of graft had good handling characteristics. The ready-to-use impregnated graft provided satisfactory haemostasis at implantation with no blood permeating through the wall after flow was restored. Both grafts exhibited low surface thrombogenicity, as determined by the uptake of labelled fibrin and platelets, and the healing sequence of the impregnated graft after resorption of the gelatin was equivalent to that of the preclotted control. Biodegradation of the gelatin was complete within 1 month of implantation with the subsequent development of a collagenous internal capsule at both anastomoses. Endothelial cells were observed between 4 and 6 months, but were confined to small islets distributed along the luminal surface. The prostacyclin/thromboxane A2 (PGI2/TXA2) ratio, which gives an indication of the level of endothelial cell activity, was greater than 1.0 after 1 week of implantation for the control graft. For the impregnated graft it reached 1.0 only after 3 months of implantation, but remained above 1.0 for periods of up to 6 months.(ABSTRACT TRUNCATED AT 250 WORDS)

Analysis of Variance

Luminal surface concentration of lipoprotein (LDL) and its effect on the wall uptake of cholesterol by canine carotid arteries.

PURPOSE: The effect of near-wall blood flow velocity and plasma filtration velocity across the arterial wall on luminal surface concentration of low-density lipoproteins (LDL) and the uptake of tritium-cholesterol were investigated. METHODS: A numeric analysis of LDL transport in steady flow, over the range of physiologically relevant flow rates, predicted a surface concentration of LDL of 4% to 16% greater than that in the bulk flow. The LDL surface concentration increased linearly with filtration velocity and inversely with wall shear rate. RESULTS: These were validated experimentally in canine carotid arteries. When the transmural pressure was increased from 100 to 200 mm Hg, the filtration velocity increased from 5.13 x 10(-6) cm/sec to 8.41 x 10(-6) cm/sec, whereas the normalized uptake rate of tritium-cholesterol increased from 3.58 x 10(-4) cm/hour to 7.36 x 10(-4) cm/hour. CONCLUSION: These results indicate that lipids accumulate at the luminal surface in areas where blood flow velocity and wall shear stress are low and where the permeability of the endothelial layer is enhanced. Moreover, the rate of lipid infiltration into the blood vessel walls is affected by the luminal surface concentration. These findings are consistent with chronic hypertension and elevated blood cholesterol concentrations being major risk factors for atherosclerosis.

Animals

The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo.

PURPOSE: The purpose of this article was to study the influence of the anastomosis angle on the flow fields at end-to-side anastomoses in vivo. METHODS: Polyurethane grafts of similar internal diameter to that of the abdominal aorta (8 mm) were implanted from the suprarenal to the infrarenal level in 10 pigs. Three angles of standardized distal end-to-side anastomoses (90 degrees, 45 degrees, and 15 degrees) were studied. The anatomic position of the anastomoses was constant, the proximal outflow segment was occluded, and the flow rate through the graft was controlled. Flow visualization was accomplished by a color-flow Doppler ultrasound system. RESULTS: The angulation was reproduced within 10%. Gross hemodynamic parameters were stable, and the similarity parameters were typical for peripheral bypasses (mean Reynold's number is 424 and Womersley's parameter is 5.9). The flow fields were clearly dependent on the anastomosis angle. A zone of recirculation (approximately 5% of the flow area), extending from the toe to one diameter downstream, was found in the 45-degree and 90-degree anastomoses. No flow disturbances were detected at the toe and one diameter downstream with an anastomosis angle of 15 degrees. At the heel different recirculating flow patterns were found in the different anastomoses. CONCLUSION: The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo.

Anastomosis, Surgical

A necropsy and histomorphometric study of abnormalities in the course of the vertebral artery associated with ossified stylohyoid ligaments.

AIMS: To establish whether abnormalities in the course of the vertebral artery occur and whether they are relevant to arterial injury associated with head and neck movements. METHODS: Twenty vertebral arteries were carefully dissected at necropsy and abnormalities in course were noted, along with any other bony or cartilaginous cervical anomalies. The effect of head and neck movement on these vessels was studied before a detailed histomorphometric examination was undertaken on sections of the excised arteries. RESULTS: Five vessels had an abnormal course. One vessel entered the transverse foramina of the fifth cervical vertebra rather than the sixth, but was otherwise normal. In two subjects both vertebral arteries were abnormal in the upper cervical portion with, in each case, a straight left vertebral artery and a right vertebral artery with a deficient loop, closely applied to the atlanto-axial joint. Both of these subjects also had completely ossified stylohyoid ligaments and the arteries visibly stretched with modest head and neck movements. Histology revealed variable degrees of smooth muscle disarray in the tunica media of two of the arteries with loop deficiencies. The circumference of one of the straight arteries was smaller than expected but in all other measured histomorphometric parameters these vessels appeared normal. CONCLUSIONS: Vertebral artery loops are deficient in a number of subjects. This finding is important given the recently described biomechanical susceptibility of the vertebral artery to longitudinal extension and may explain the smooth muscle changes, in that this may represent attempts at arterial wall remodelling. Subjects with such loop deficiencies may be more susceptible to a variety of head and neck insults and such abnormalities should be sought at necropsy in subjects who die as a result of fatal vertebral artery injury.

Adult

Expanded polytetrafluoroethylene arterial prostheses in humans: histopathological study of 298 surgically excised grafts.

The expanded polytetrafluoroethylene vascular prosthesis is considered to be the best synthetic alternative for peripheral arterial reconstruction. Most studies on the healing characteristics of expanded polytetrafluoroethylene prostheses have been carried out on animals, and very few data are available on prosthesis implanted in humans long term. We implanted 298 expanded polytetrafluoroethylene grafts as arterial substitutes in humans. The mean duration of implantation was 523 d and the grafts were implanted mainly for infrainguinal or axillofemoral bypass. The cellular and collagen infiltration of the microporous expanded polytetrafluoroethylene structure was generally poor. Infiltration occurred mainly in the external region of the prosthetic wall and increased with the duration of implantation. The external reinforcement was not a major factor in limiting tissue infiltration. The luminal surfaces were covered with a thin, irregular layer of organized fibrin, interspersed with exposed expanded polytetrafluoroethylene areas. Mineral deposits were observed in five cases. Despite poor healing, the clinical performance of expanded polytetrafluoroethylene vascular prostheses is relatively good. Since the chief advantage of this material is good mechanical stability in vivo, any modifications of the graft to improve healing characteristics or thrombogenic properties should not be made at the expense of stability in vivo.

Adult

Expanded polytetrafluoroethylene arterial prostheses in humans: chemical analysis of 79 explanted specimens.

The expanded polytetrafluoroethylene (ePTFE) vascular prostheses are widely used as small and medium diameter blood conduits when an autologous venous material is not available or is not suitable. The long-term performance of a prosthesis is dependent on several factors, including its healing characteristics and its stability in vivo. This study was undertaken to assess whether chemical degradation of ePTFE occurs when such arterial substitutes are implanted in humans. Seventy-nine ePTFE grafts excised for complications were analysed using the following techniques: measurement of the contact angle (theta), electron spectroscopy for chemical analysis (ESCA or XPS), Fourier transform infra-red spectroscopy (FTIR) and differential scanning calorimetry (DSC). The results were compared with those obtained from virgin ePTFE and virgin ePTFE washed prostheses. The measurement of the contact angle (theta) permits the comparison of the level of hydrophobicity of material after in vivo residency. The contact angles of explanted ePTFE grafts are greater than those of virgin ones but remain close to those of washed virgin prostheses. The ESCA method allowed investigation of the chemical changes which occur on the surface of ePTFE prostheses after implantation because of the low penetration of the X-ray (about 50 A). This study did not reveal any chemical degradation of the ePTFE with time of implantation for periods up to 6.5 yr. Changes in the surface composition were probably related to lipid and/or protein uptake. The FTIR spectroscopy provides information about the chemical composition of material. Compared with the virgin ePTFE prostheses, the FTIR spectra of explanted prostheses showed specific bands which are characteristic of lipid and/or protein absorptions. The bulk properties of ePTFE studied by DSC did not show any significant changes with time of implantation. It is concluded that ePTFE grafts remain stable in vivo for periods up to 6.5 yr.

Biocompatible Materials

Vascular access for hemodialysis: pathologic features of surgically excised ePTFE grafts.

We analyzed 52 surgically excised ePTFE grafts used as secondary vascular access in chronic hemodialysis patients, structurally and histopathologically. Pseudoaneurysm formation at the site of repeated venipuncture was the main cause of surgical removal later than two years after implantation. Repeated needle punctures, twice per treatment, two or three times a week may result in a perigraft fibrous tissue capsule directly above areas where the graft was punctured. The delicate microporous structure of the graft wall was shown to be disrupted by needle punctures. The needle puncture sites were filled by surrounding connective tissue, and in one case, capillary formation was observed within the puncture sites. Examination by both light and scanning electron microscopy demonstrated identical patterns of pseudointima on the luminal surface. A thin pannus of endothelium-like cells, confined to the vicinity of the anastomoses, was noted in only four cases. On other areas of the luminal surface without endothelium, a red coagulum incorporating blood cells and fibrin was observed. Histological evidence of acute infection was absent in 61% of the cases and only 27% were considered to be clinically infected. Careful needle puncture technique, systematic rotation of puncture sites, and the use of rigorous aseptic technique are essential in preserving the long-term structural integrity of the vascular access, despite the good mechanical properties and reasonable good resistance to infection of ePTFE grafts.

Adult

Phonocardiogram spectral analysis simulator of mitral valve prostheses.

Spectral analysis of sounds produced in vitro by mitral valve prostheses placed in a specially designed flow simulator has been carried out using a short-time Fourier representation of the recorded signal. Time variations of power spectra are displayed as a three-dimensional plot. Sounds produced by three types of valves, namely ball and cage, tilting disk and porcine valves, were analysed. Each valve type produced a characteristic spectrogram, and, for a given valve, spectrograms were reproducible to within a margin of 5 dB. The simulator may be used to detect structural deficiencies and functional abnormalities of prosthetic heart valves. In addition to quantifying the noise level of mechanical valves, the system may be used for quality control purposes to identify faulty valves.

Equipment Design