PubMed Health⌕ Search

Biomedical subjects

T Irvine

Publications and source records attributed to T Irvine.

At least 19 recordsLinked to original sources

Surface integration of velocity vectors from 3D digital colour Doppler: an angle independent method for laminar flow measurements.

BACKGROUND: The study was designed to test the angle independence of a dynamic three-dimensional digital colour Doppler method for laminar flow measurement. The technique acquired three-dimensional data by rotational acquisition and used surface integration of Doppler vector velocities and flow areas in time and space for flow computation. METHOD: A series of pulsatile flows (peak flow 55-180 ml/s) through a curved tube were studied with reference flow rates obtained using an ultrasonic flow meter. Colour Doppler imaging was performed at three angles to the direction of flow (20 degrees, 30 degrees, 40 degrees), using a multiplane transoesophageal probe controlled by an ATL HDI5000 system. Integration of digital velocity vectors over a curved three-dimensional surface across the tube for each of the 11 flow rates at each angle was performed off-line to compute peak flow. RESULTS: Peak flow rates correlated closely (r=0.99) with the flow meter with the mean difference from the reference being -0.8+/-2 x 4 ml/s, 0.9+/-2.6 ml/s, 1.0+/-2 x 3 ml/s for 20 degrees, 30 degrees and 40 degrees respectively. Comparison of the three angle groups showed no significant differences (P=0.15, ANOVA). When sampled obliquely, the flow area on the curved surface increased while the velocities measured decreased. CONCLUSION: Surface integration of velocity vectors to compute three-dimensional Doppler flow data is less angle dependent than conventional Doppler methods.

Blood Flow Velocity↗

Dobutamine stress echocardiography for the detection of myocardial viability in patients with left ventricular dysfunction taking beta blockers: accuracy and optimal dose.

OBJECTIVE: To assess the accuracy of dobutamine stress echocardiography (DSE) and the optimal dose of dobutamine to detect myocardial viability in patients with ischaemic left ventricular (LV) dysfunction who are taking beta blockers, using the recovery of function six months artery revascularisation as the benchmark. PATIENTS: 17 patients with ischaemic LV dysfunction (ejection fraction < 40%) and chronic treatment with beta blockers scheduled to undergo surgical revascularisation. SETTING: Regional cardiothoracic centre. METHODS: All patients underwent DSE one week before and resting echocardiography six months after revascularisation. A wall motion score was assigned to each segment for each dobutamine infusion stage, using the standard 16 segment model of the left ventricle. The accuracy of DSE to predict recovery of resting segmental function was calculated for low dose (5 and 10 microg/kg/min) and for a full protocol of dobutamine infusion (5 to 40 microg/kg/min). RESULTS: Of the 272 segments studied, 158 (58%) were dysfunctional at rest, of which 79 (50%) improved at DSE and 74 (47%) recovered resting function after revascularisation. Analysis of results with a low dose showed a significantly lower sensitivity and negative predictive value than with a full protocol (47% v 81%, p < 0.001 and 65% v 82%, p < 0.05, respectively). The accuracy in the full protocol analysis was comparable with that reported in patients no longer taking beta blockers but was significantly lower than that in the low dose analysis (78% v 66%, p < 0.001). CONCLUSIONS: Findings suggest that beta blocker withdrawal is not necessary before DSE when viability is the clinical information in question. However, a completed protocol with continuous image recording is required to detect the full extent of viability.

Adrenergic beta-Antagonists↗

In vitro validation of tissue Doppler left ventricular regional wall velocities by using a novel balloon phantom.

To investigate the validity and accuracy of tissue Doppler imaging (TDI) using a novel balloon phantom, validation of TDI myocardial velocity measurements has been carried out indirectly from conventional M-mode images. However it is not a true and independent gold standard. We described a new TDI validation method by using a specially developed left ventricular balloon model mounted in a water bath and constructed using two pear-shaped balloons. It was connected to a pulsatile flow pump at 8 stroke volumes (50-85 ml/beat). The displacement and velocity of the balloon walls were recorded simultaneously by video imaging and TDI on a GE-Vingmed System Five with a 5 MHz phased array probe at the highest frame rates available. Conventional M-mode and 2-D imaging verified that our balloon model mimicked the shape and wall motion of left ventricle. There was a good correlation and agreement between the maximum video excursion of the anterior and posterior walls of the phantom and the results of the temporal integration of digital distance data by TDI (Anterior wall: r = 0.97, SEE = 0.24 mm, mean +/- s = 0.04 +/- 0.24 mm; Posterior wall: r = 0.95, SEE = 0.22 mm, mean +/- s = 0.03 +/- 0.24 mm). Analysis of the velocity profile by the TDI method showed that the velocity at each measured point was correlated well with the velocity obtained from the video images (Anterior wall: r = 0.97, SEE = 0.30 mm, mean +/- s = -0.04 +/- 0.28 mm; Posterior wall: r = 0.97, SEE = 0.30 mm, mean +/- s = 0.04 +/- 0.28 mm). Our balloon model provided a new independent method for the validation of TDI data. This study demonstrated that the present TDI system is reliable for measuring wall motion distance and velocity.

Echocardiography, Doppler↗

Validation of a digital color Doppler flow measurement method for pulmonary regurgitant volumes and regurgitant fractions in an in vitro model and in a chronic animal model of postoperative repaired tetralogy of Fallot.

OBJECTIVES: The purpose of this study was to validate a digital color Doppler (DCD) automated cardiac flow measurement method for quantifying pulmonary regurgitation (PR) in an in vitro and a chronic animal model of the right ventricular outflow tract of postoperative tetralogy of Fallot (TOF). BACKGROUND: There has been no reliable ultrasound method that can accurately quantitate PR. METHODS: We developed an in vitro model of mild pulmonary stenosis and wide-open PR that mimics the patterns of flow seen in patients with postoperative TOF. Thirteen different forward and regurgitant stroke volumes (RSVs) across the noncircular shaped cross-sectional outflow tract flow area were estimated using the DCD method in two orthogonal planes. In six sheep with surgically created PR, 24 different hemodynamic states with PR strictly quantified by electromagnetic probes were also studied. RESULTS: The RSVs and regurgitant fractions (RFs) obtained by the DCD method using average values from two orthogonal planes correlated well with reference values (RSV: r = 0.99, mean difference = 0.02 +/- 0.39 ml/beat for in vitro model; r = 0.97, mean differences = 1.79 +/- 1.84 ml/beat for animal model, RF: r = 0.98, mean difference = -1.10 +/- 4.34% for in vitro model; r = 0.94, mean difference = 2.73 +/- 6.75% for animal model). However, the DCD method using a single plane had limited accuracy for estimating pulmonary RFs and RSVs. CONCLUSIONS: The DCD method using average values from two orthogonal planes provides accurate estimation of RSVs and RFs and should have clinical importance for serially quantifying PR in patients with postoperative TOF.

Animals↗

Noninvasive assessment of left ventricular isovolumic contraction and relaxation with continuous wave Doppler aortic regurgitant velocity signals: an in vivo validation study.

The purpose of this study was to provide fundamental in vivo validation of a method with the use of aortic regurgitant (AR) jet signals recorded with continuous wave (CW) Doppler for assessing left ventricular (LV) isovolumic contraction and relaxation. Preliminary studies have suggested that analysis of CW Doppler AR velocity signals permits the estimation of LV positive and negative dP/dt. We studied 19 hemodynamically different states in 6 sheep with surgically induced chronic aortic regurgitation. CW AR velocity spectra and high-fidelity LV and aortic pressures were recorded simultaneously. Rates of LV pressure rise and fall (RPR and RPF) were calculated by determining the time interval between points at 1 m/s and 2.5 m/s in the deceleration and acceleration slopes of the CW Doppler AR velocity envelope (corresponding to a pressure change of 21 mm Hg). RPR and RPF calculated by CW Doppler analysis for each state were compared with the peak positive dP/dt and negative dP/dt, obtained from the corresponding high-fidelity LV pressure curve, respectively. The LV peak positive and negative dP/dt derived by catheter ranged from 817 to 2625 mm Hg/s and from 917 to 2583 mm Hg/s, respectively. Multiple regression analysis showed that Doppler RPR correlated well with catheter peak positive dP/dt (r = 0.93; mean differences, -413 +/- 250 mm Hg/s). There was also good correlation and agreement between Doppler RPF and the catheter peak negative dP/dt (r = 0.89; mean difference, -279 +/- 239 mm Hg/s). Both Doppler-determined RPR and RPF underestimated their respective LV peak dP/dt. CW Doppler AR spectra can provide a reliable noninvasive estimate of LV dP/dt and could be helpful in the serial assessment of ventricular function in patients with aortic regurgitation.

Animals↗

Quantification of aortic regurgitation by real-time 3-dimensional echocardiography in a chronic animal model: computation of aortic regurgitant volume as the difference between left and right ventricular stroke volumes.

BACKGROUND: The accuracy of conventional 2-dimensional echocardiographic and Doppler techniques for the quantification of valvular regurgitation remains controversial. In this study, we examined the ability of real-time 3-dimensional (RT3D) echocardiography to quantify aortic regurgitation by computing aortic regurgitant volume as the difference between 3D echocardiographic-determined left and right ventricular stroke volumes in a chronic animal model. METHODS: Three to 6 months before the study, 6 sheep underwent surgical incision of one aortic valve cusp to create aortic regurgitation. During the subsequent open chest study session, a total of 25 different steady-state hemodynamic conditions were examined. Electromagnetic (EM) flow probes were placed around the main pulmonary artery and ascending aorta and balanced against each other to provide reference right and left ventricular stroke volume (RVSV and LVSV) data. RT3D imaging was performed by epicardial placement of a matrix array transducer on the volumetric ultrasound system, originally developed at the Duke University Center for Emerging Cardiovascular Technology. During each hemodynamic steady state, the left and right ventricles were scanned in rapid succession and digitized image loops stored for subsequent measurement of end-diastolic and end-systolic volumes. Left and right ventricular stroke volumes and aortic regurgitant volumes were then calculated and compared with reference EM-derived values. RESULTS: There was good correlation between RT3D left and right ventricular stroke volumes and reference data (r = 0.83, y = 0.94x + 2.6, SEE = 9.86 mL and r = 0.63, y = 0.8x - 1.0, SEE = 5.37 mL, respectively). The resulting correlation between 3D- and EM-derived aortic regurgitant volumes was at an intermediate level between that for LVSV and that for RVSV (r = 0.80, y = 0.88x + 7.9, SEE = 10.48 mL). RT3D tended to underestimate RVSV (mean difference -4.7 +/- 5.4 mL per beat, compared with -0.03 +/- 9.7 mL per beat for the left ventricle). There was therefore a small overestimation of aortic regurgitant volume (4.7 +/- 10.4 mL per beat). CONCLUSION: Quantification of aortic regurgitation through the computation of ventricular stroke volumes by RT3D is feasible and shows good correlation with reference flow data. This method should also be applicable to the quantification of other valvular lesions or single site intracardiac shunts where a difference between right and left ventricular cavity stroke volumes is produced.

Animals↗

Clinical significance of the length of the pterygopalatine fissure in dental anesthesia.

OBJECTIVE: This study determined the average length of the pterygopalatine fissure by using human cadavers. Recommendations are made to improve the success of maxillary nerve block injections. MATERIALS AND METHODS: Pterygopalatine fissures were dissected, exposing the maxillary nerve trunk in 47 human cadavers. The length of the fissure was measured from the maxillary nerve to the buccal sulcus. The angle between the fissure and the occlusal plane was also recorded. RESULTS: The average fissure length was 36.7 mm, making an approximately 60 degrees angle to the occlusal plane. Fissures from females were statistically significantly shorter than those from males. There was no difference with respect to ethnic group. Cadaver length was the best predictor of fissure length. CONCLUSIONS: Depth of penetration with a needle that is longer than that normally available is necessary to predictably ensure a successful maxillary nerve block.

Anesthesia, Dental↗

Double blind randomised controlled trial of topical glyceryl trinitrate in anal fissure.

AIMS: To determine the effectiveness and safety of topical glyceryl trinitrate (GTN) in the management of acute anal fissure in children. METHODS: Individual children were randomised to receive GTN paste or placebo for six weeks in addition to oral senna and lactulose. Patients took laxatives alone for a further 10 weeks. Each week a research nurse telephoned families to assess pain scores and give advice. Main outcome measures were validated standardised pain scores and time to painless defaecation. RESULTS: Forty subjects were recruited from 46 eligible children; 31 children completed the trial (13 in the GTN group and 18 in the placebo group). No differences in the proportion of those achieving pain free defaecation with relation to time were seen between the two groups. Similarly, there were no significant differences in pain scores between the two groups over the 16 week study period. However, in both groups pain scores had decreased significantly. There were no differences in the incidence of rectal bleeding, faecal soiling, presence of visible fissure, skin tag, or faecal loading at outpatient review at the time of recruitment, or at 6 weeks and 16 weeks. No serious adverse effects were observed. CONCLUSIONS: This study suggests that 0.2% GTN paste is ineffective in the treatment of acute anal fissures in childhood. However the overall fissure healing rate is high (84%) with associated reduction in pain scores, suggesting that a nurse based treatment programme can achieve a high rate of fissure healing.

Acute Disease↗

Direct computation of multiple 3D flow convergence isovelocity surfaces from digital 3D reconstruction of colour Doppler data of the flow convergence region: an in vitro study with differently shaped orifices.

AIMS: Evaluation of the accuracy of direct computation of multiple three-dimensional (3D) flow convergence (FC) isovelocities by using digital reconstruction of colour Doppler data of the flow convergence region. METHODS AND RESULTS: We used a conventional ultrasound system (ATL HDI 3000) connected to a computer workstation via Ethernet link. The digital 3D datasets were directly transferred to a Silicon Graphic Imaging Octane workstation for later measurement. We generated nine pulsatile flows (20-60 ml/beat), with peak flow rates (67-180 ml/s), through three orifices (circular, rectangular and triangular, S=0.24 cm(2)). The 3D reconstructions of FC surface areas from multi-threshold velocities, including aliasing velocities were analysed to quantify the peak flow rate. For all orifices, linear regression demonstrated excellent correlation between the 3D calculated and electromagnetic flow meter recorded data. While there was a high correlation for 3D computation of flow rate from the single best Nyquist of 24 cm/s (r=0.97-0.98, SEE=7 .75-12.58 ml/s), the ability to average three threshold velocities (15, 18 and 24 cm/s) yielded an improved correlation (r=0.98-0.99, SEE=5.70-7.73 ml/s). CONCLUSIONS: Direct computation of multiple 3D FC isovelocities from digital reconstruction of colour Doppler data of the FC region provides the potential to accurately quantify the complex asymmetric spatial flow events at any selected velocity.

Blood Flow Velocity↗

A digital 3-dimensional method for computing great artery flows: in vitro validation studies.

BACKGROUND: Conventional 2-dimensional Doppler large vessels are prone to inaccuracy. Three-dimensional (3D) volume imaging provides the opportunity to make cross-sectional flow calculations through digital spatiotemporal integration of flow velocity, area, and profile. METHODS: A new digital 3D color Doppler reconstruction method was used to generate radially acquired flow data sets. Raw scanline data with digital velocity assignments, obtained by scanning parallel to flow, were transferred from a specially programmed but otherwise conventional ultrasonographic system, which controlled a multiplane transesophageal probe, to a computer workstation via an Ethernet link for assimilation into color 3D data sets. This configuration was used to study 20 pulsatile laminar flows (stroke volumes 30 to 70 mL and peak flow rates 65 to 205 mL/s) in a curved tube model with an oval cross-sectional geometry. After generation of the color 3D data set, flow velocity values from cross sections perpendicular to the tubes were analyzed to determine flow rate and stroke volume. RESULTS: The flows from 3D digital velocity profiles showed close correlation with peak instantaneous flow rates (r = 0.99, y = 1.01x-0.9, standard error of estimate 4.1 mL/s). When interpreted with pulsed wave Doppler data obtained through the cardiac cycle, they also allowed computation of stroke volume (r = 0.98, y = 1.44x-2.5, standard error of estimate 3.8 mL). CONCLUSION: The ability to compute laminar flows from 3D digital data sets obtained parallel to the direction of flow and without the need for geometric assumptions represents an important opportunity for and advantage of 3D color Doppler echocardiography.

Coronary Vessels↗

Comparison of ventricular volume and mass measurements from B- and C-scan images with the use of real-time 3-dimensional echocardiography: studies in an in vitro model.

BACKGROUND: Real-time 3-dimensional (3D) echocardiography avoids geometric assumptions in volume analysis and permits immediate visualization in any plane without the need for cardiac or respiratory gating or computation time. This study compared the accuracy of volume and mass assessments between standard long-axis (B-scan) and short-axis (C-scan) views in a simplified but quantifiable left ventricular phantom. METHODS AND RESULTS: The model comprised an inner balloon within an outer balloon separated by ultrasonographic gel. First, to mimic different chamber volumes, 12 volumes (40 to 180 mL) of water within the inner balloon were scanned with a real-time 3D system. Second, 10 volumes (80 to 170 mL) of gel were inserted between the balloons to mimic varying cardiac mass, and the gel volume space (mass) was calculated by subtracting the inner from the outer balloon volume. "Chamber" and "mass" measurements for both B and C scans correlated closely with the actual values (r = 0.99). However, chamber volumes from C scans were consistently less than B-scan values (mean difference from reference for C scans: -5.2 +/- 1.2 mL, P <.0001; for the 2 orthogonal B scans: 0.03 +/- 1.4 mL and -0.9 +/- 1.5 mL, respectively, P = NS). Similarly, for gel volume measurements, B-scan results were closer to actual mass volumes (mean difference 0. 3 +/- 2.5 and 1.7 +/- 2.9 mL) than those of C scans, which tended to underestimate (-4.5 +/- 2.5 mL, P <.0001). CONCLUSION: Our study suggests that real-time 3D echocardiography should provide an accurate means of determining chamber volumes and cardiac mass. However, measurements performed from B-scan views may be closer to the actual values than those from C-scan views, presumably since they are less highly influenced by distortions related to lateral resolution.

Cardiac Volume↗

Three-dimensional echocardiographic reconstruction of mitral valve color Doppler flow events.

In vitro studies have suggested superior accuracy of 3-dimensional echocardiography over conventional methods for the characterization and quantitation of color Doppler flow events. Little in vivo work has been reported in this area; this study demonstrates the feasibility of 3-dimensional reconstruction of mitral valve flow events in an unselected group of adult patients and discusses optimal instrument settings for the acquisition of 3-dimensional datasets.

Adult↗

Three-dimensional reconstruction of the color Doppler-imaged vena contracta for quantifying aortic regurgitation: studies in a chronic animal model.

BACKGROUND: The purpose of this study was to investigate the use of 3-dimensional (3D) reconstruction of color Doppler flow maps to image and extract the vena contracta cross-sectional area to determine the severity of aortic regurgitation (AR) in an animal model. Evaluation of the vena contracta with 2-dimensional imaging systems may not be sufficiently robust to fully characterize this region, which may be asymmetrically shaped. METHODS AND RESULTS: In 6 sheep with surgically induced chronic AR, 18 hemodynamically different states were studied. Instantaneous regurgitant flow rates were obtained by aortic and pulmonary electromagnetic flowmeters (EMFs) as reference standards, and aortic regurgitant effective orifice areas (EOAs) were determined from EMF regurgitant flow rates divided by continuous-wave (CW) Doppler velocities. Composite video data for color Doppler imaging of the aortic regurgitant flows were transferred into a TomTec computer after computer-controlled 180 degrees rotational acquisition. After the 3D data transverse to the flow jet were sectioned, the smallest proximal jet cross section was identified for direct measurement of the vena contracta area. Peak regurgitant flow rates and regurgitant stroke volumes were calculated as the product of these areas and the CW Doppler peak velocities and velocity-time integrals, respectively. There was an excellent correlation between the 3D-derived vena contracta areas and reference EOAs (r=0.99, SEE=0.01 cm2) and between 3D and reference peak regurgitant flow rates and regurgitant stroke volumes (r=0.99, difference=0.11 L/min; r=0.99, difference=1.5 mL/beat, respectively). CONCLUSIONS: 3D-based determination of the vena contracta cross-sectional area can provide accurate quantification of the severity of AR.

Animals↗

Dobutamine stress echocardiography: improved endocardial border definition and wall motion analysis with tissue harmonic imaging.

BACKGROUND: We performed a study to determine whether tissue harmonic imaging (THI) facilitates wall motion analysis at rest and whether these benefits extend through the stages of a dobutamine stress echocardiography (DSE) study. We also assessed the impact of THI on the feasibility of DSE in technically difficult patients. Finally we tested the hypothesis that THI by improving endocardial border definition (EBD) could enhance the interobserver agreement between trainees and experienced operators for interpreting DSE studies. METHODS: Twenty unselected patients underwent DSE by standard protocol. Parasternal and apical views were obtained with the use of fundamental mode (FND) and THI at baseline, low dose, and peak stress. Segmental EBD was characterized as 1 to 4 (1 = excellent) and segmental wall motion was characterized as 1 to 4/x (1 = normal, x = unable to interpret) by a consensus of 2 experienced observers. A trainee in stress echocardiography independently scored all segments, and these results were compared with the consensus of the experienced readers. RESULTS: EBD improved with THI in 26 +/- 6.7 of 48 segments per patient (54%, 95% confidence interval [CI] 0.40 to 0.68) and deteriorated with THI in only 2 +/- 2.7 (4%, 95% CI 0 to 0.09). Of the total of 48 segments per patient, a mean of 10 +/- 5.7 (21%, 95% CI 0.10 to 0.31) were of inadequate quality to be interpreted for wall motion on FND, and this changed to 4 +/- 3.4 (6%, 95% CI 0.06 to 0.12) on THI (P <.001). EBD improved in a similar degree in all DSE stages 53%, 54%, and 53% for rest, low dose, and peak stress, respectively. Six of the 20 study patients were deemed unsuitable for DSE on FND, and all were changed to suitable subjects on THI. Of the 205 segments deemed unsuitable for interpretation on FND, 140 (68%) were of the anterior and lateral walls of the LV. Improvement with THI was also more prominent on these walls. The mean coefficient of agreement (kappa) for wall motion analysis was 0.82 +/- 0.14 on FND and improved to 0. 92 +/- 0.09 on THI (P <.001). CONCLUSIONS: THI dramatically improves EBD and the ability to confidently score segmental wall motion. Interobserver agreement is also significantly enhanced. These benefits extend to the peak stage of a DSE study. Routine use of THI may enhance the diagnostic accuracy of DSE and extend its application to technically difficult patients previously deemed unsuitable.

Adult↗