Publications and source records attributed to T J Bowker.

18 recordsLinked to original sources

Impact of postangioplasty restenosis on comparisons of outcome between angioplasty and bypass grafting. Coronary Angioplasty versus Bypass Revascularisation Investigation (CABRI) Investigators.

Restenosis is a major limitation of percutaneous transluminal coronary angioplasty (PTCA). In this study, we assessed the impact of restenosis on PTCA with reference to coronary angioplasty bypass grafting (CABG). In the Coronary Angioplasty versus Bypass Revascularisation Investigation (CABRI) PTCA population, those who had restenosis were defined as those needing a second revascularization at a site revascularized at the initial procedure. The 1-year clinical outcome of the nonrestenotic group (n=437) was compared with those who underwent CABG (n=453). There was no difference in deaths. In the nonrestenotic PTCA group, the incidence of more infarctions was insignificant (relative risk [RR] 1.9, 95% confidence intervals [CI] 0.96 to 3.75, p=0.064), there was a much greater need for repeat revascularization (RR 8.6, CI 5.14 to 14.41, p <0.0005), and patients had a poorer angina status (RR 1.46, CI 1.01 to 2.13, p=0.046). Using 2 measures of coronary disease, the degree of pre- and postrevascularization disease was compared between groups. There were no differences in prerevascularization disease. However, using either measure, residual postrevascularization disease was more frequent in the nonrestenotic PTCA group. Restenosis only partially accounts for the greater morbidity seen after PTCA, compared with CABG, in multivessel disease. The greater likelihood of residual disease post-PTCA may contribute to this greater morbidity.

Adult

Differential restenosis rate of individual coronary artery sites after multivessel angioplasty: implications for revascularization strategy. CABRI Investigators. Coronary Angioplasty versus Bypass Revascularisation Investigation.

BACKGROUND: Restenosis is a major limitation of angioplasty. In this analysis we assessed the effects of lesion site and quality of dilatation on restenosis rate in the Coronary Angioplasty versus Bypass Revascularization Investigation population who underwent angioplasty. METHODS: The angiographic quality of the successful angioplasty revascularization at each site was assessed, and the subsequent restenosis rate was determined. Restenosis was defined by the need for a second angioplasty at the initial site or by surgical coronary bypass grafting at or distal to the initial site. RESULTS: The restenosis rate was unaffected by quality of dilatation but was significantly more common in the proximal left anterior descending artery compared with other sites, whether or not optimal dilatation had been achieved (relative risk 2.0 and 1.9, respectively). CONCLUSION: Revascularization strategies in multivessel disease should consider the presence or absence of a proximal left anterior descending artery target. Furthermore in studies in which restenosis is an outcome of interest, an allowance should be made for the distribution of target disease.

Aged

A British Cardiac Society survey of the potential for the secondary prevention of coronary disease: ASPIRE (Action on Secondary Prevention through Intervention to Reduce Events).

OBJECTIVE: To measure the potential for secondary prevention of coronary disease in the United Kingdom. DESIGN: Cross sectional survey of a representative sample of coronary patients from a retrospective review of hospital medical records and patient interview and examination. SETTING: Stratified random sample of 12 specialist cardiac centres and 12 district general hospitals drawn from 34 specialist cardiac centres and 261 district general hospitals in 12 geographic areas in the United Kingdom. SUBJECTS: 2583 patients < or = 70 yr; 25 consecutive males and 25 consecutive females identified retrospectively in each of four diagnostic categories: coronary artery bypass grafting, percutaneous transluminal coronary angioplasty, acute myocardial infarction, and acute myocardial ischaemia without evidence of infarction. MAIN OUTCOME MEASURES: Risk factor recording and management in medical records; the prevalence and control of risk factors at interview six months after the procedure or event. RESULTS: Recording of coronary risk factors in patient's records was incomplete and this varied by risk factor. Smoking habit and blood pressure were most completely recorded, whereas a history of hyperlipidaemia and blood cholesterol concentrations were least complete. Risk factor records were more likely to be complete in cardiac centres than in district hospitals. At interview 10% to 27% of patients were still smoking cigarettes and 75% remained overweight, females more severely so. Up to a quarter of patients remained hypertensive, males more severely so than females. Over three quarters had a total cholesterol > 5.2 mmol/l. In patients on medication for blood pressure, cholesterol or glucose, risk factor profiles were little better than in those who were not. Only about one patient in three was taking a beta blocker after infarction. Up to a fifth of patients who had had acute myocardial ischaemia were not taking aspirin at follow up. CONCLUSIONS: There is considerable potential to reduce the risk of a further major ischaemic event in patients with established coronary disease. This can be achieved by effective lifestyle intervention, the rigorous management of blood pressure and cholesterol, and the appropriate use of prophylactic drugs.

Adrenergic beta-Antagonists

Sudden unexpected cardiac death: methods and results of a national pilot survey.

In order to develop a methodology for measuring the occurrence and circumstances of sudden unexpected adult deaths due to cardiac and to unidentified causes throughout England, a stratified random pilot sample of 12 of the 133 coroner's jurisdictions in England was invited to survey prospectively a quota sample of 78 consecutive white Caucasians, aged from 16 to 64 years, with no history of ischaemic heart disease, who were last seen alive within 12 h of being found dead, and for whom a coroner's post-mortem examination found either a cardiac or no identifiable cause of death. Eleven (92%) coroners participated. In a median of 105 days (range 21-169), 65 cases (83% of the quota) were ascertained (54 (83%) males). Of the ascertained cases, registration forms were received on 62 (95%), tissue specimens on 63 (97%), and post-mortem reports on 58 (89%). Death was witnessed in 58%, of which 35% were 'instantaneous'. The median time from symptom onset to death was 40 min. In unwitnessed deaths, the median time since last being seen alive was 90 min. Sixty-eight per cent of all deaths were attended--by a relative in 34%, passer-by (8%), ambulance crew (32%), nurse (11%), doctor (38%), and police (9%). Cardio-pulmonary resuscitation was attempted in 38 of the 42 attended deaths. Sixty-seven per cent were taken ill at home, 12% at work, 12% in a public place, and 10% elsewhere. The certified cause of death was ischaemic heart disease in 89%, in whom coronary thrombosis and/or myocardial damage was absent in 6 cases (9%). In the remainder, the certified cause was hypertensive heart disease (5%), hypertrophic obstructive cardiomyopathy (3%), 'cardiomegaly' (1.5%) and 'sudden cardiac arrhythmia' alone (1.5%). A retrospective audit of coroner's records revealed the median case ascertainment rate was 75%. This approach to surveying sudden unexpected adult death nationally resulted in a high response rate (92%) from coroners, consultant pathologists and their staff, the identification of a large proportion of eligible cases, and complete information in most of the identified cases. In from 2% to 15% of cases, death may have been either purely dysrhythmic or due to a sudden adult death syndrome.

Adolescent

Percutaneous transluminal coronary angioplasty in chronic coronary artery occlusion.

OBJECTIVES: This study was conducted to determine the procedural success rate, complication rate and long-term outcome of percutaneous transluminal coronary angioplasty in chronically occluded coronary arteries. BACKGROUND: Coronary angioplasty of chronically occluded vessels has a lower success rate than has angioplasty of nonoccluded vessels, but it is frequently considered safe because the target vessel is already occluded. The purpose of this study was to determine the reliability of these assumptions at our institution, with the objectives stated above. METHODS: We identified from the angioplasty data base at our institution 100 consecutive coronary angioplasty procedures performed between 1987 and 1991 for chronic total occlusion, defined as complete occlusion (Thrombolysis in Myocardial Infarction [TIMI] grades 0 and 1 flow) for > or = 3 months. The records of the 95 patients who underwent these procedures were reviewed to determine procedural outcome and medium-term results. RESULTS: Procedural success was obtained in 47 occluded vessels (47%). Significantly fewer successes were obtained in the right coronary artery (26.8%) than in either the left anterior descending (57.1%) or the left circumflex (45%) coronary artery (p < 0.05). A procedural failure without serious adverse consequences occurred in 45 procedures (45%), but in eight patients (right coronary artery in five, left anterior descending artery in three) attempted recanalization was complicated by extensive coronary dissection with acute myocardial ischemia, and one of these patients died. There were no emergency operations, but elective coronary artery bypass surgery was undertaken in 26 patients (in 3 after extensive dissection, in 7 after an apparently good result and in 16 in whom the procedure failed). At 12 months after the procedure, 64.1% of those with a procedural success were event free compared with 32.6% of those whose procedure was both unsuccessful and uncomplicated (p < 0.025) and 25% of those in whom it was unsuccessful and complicated by coronary dissection (p < 0.025). CONCLUSIONS: In this series of recanalization of chronically occluded coronary arteries, there was a low procedural success rate, particularly for the right coronary artery. However, when procedural success was obtained, the long-term outlook was good. The overall risk of coronary dissection was comparable to the risk in nonoccluded vessels but was particularly high in the right coronary artery (13%).

Adult

A new method of haemodynamic assessment of mitral stenosis in atrial fibrillation: construction of a nomogram.

Accurate haemodynamic assessment of mitral stenosis by hydraulic formulas requires measurement of the mean valve gradient and the cardiac output. The calculation is laborious, particularly in the presence of atrial fibrillation when averaged values obtained from multiple beat-to-beat determinations must be used. The relations between valve area, end diastolic gradient, and heart rate in 20 patients with mitral stenosis and atrial fibrillation were examined. In each patient the end diastolic pressure gradient for each cardiac cycle was related linearly to the RR interval of that cycle, and this relation was unchanged on exercise. The slope (S) and intercept (I) of this relation correlated with the degree of mitral stenosis as measured by the Gorlin valve area. The regression equations describing these relations were then used to construct a nomogram relating end diastolic pressure gradient to mitral valve area at different heart rates. When the nomogram was applied to catheterisation data from a further 30 patients the results correlated well with direct calculation of valve area by the Gorlin formula. The nomogram is simple to use, does not require measurement of cardiac output, and is independent of heart rate so that it is unnecessary for the patient to exercise during catheterisation.

Atrial Fibrillation

Laser angioplasty with a pulsed NdYAG laser: early clinical experience.

Since December 1986, 40 laser angioplasty procedures have been performed using the energy from a pulsed NdYAG laser, delivering near infrared light (1064 nm) in 100-microseconds pulses of approximately 300 mJ per pulse, directly through a transparent sapphire tipped device. All patients had total occlusion of the superficial femoral artery and symptoms severe enough to warrant surgery, with ulceration or gangrene in eight, rest pain in 14 and severe claudication interfering with life-style in the others. The device was introduced through an antegrade puncture of the superficial or common femoral artery and laser recanalization was followed by attempted balloon angioplasty in all cases. Occlusions were a median length of 15 cm (range 2-35 cm); ten patients had previously undergone failed attempts at conventional balloon angioplasty and four had occluded femoropopliteal grafts. Thirty-seven legs of 34 patients were treated with an average of 60 J (range 10-235 J) with successful recanalization in 27 and immediate reocclusion in seven. The 20 successful recanalizations have been followed up for up to 24 months (median 7 months) with only one late occlusion at 5 months. Failed recanalization was due to poor transmission by the delivery device in the early part of the series (five cases), repeated passage of the device down a collateral branch (four cases), dissection at the site of previous surgery (two cases) or no apparent reason (two cases). Immediate reocclusion was due to very poor run off in patients with severely ischaemic limbs (three cases) or technical difficulties with balloon dilatation (two cases). Complete symptomatic relief was obtained in all the cases of radiologically successful laser angioplasty. Early surgery was required in one case following reocclusion of the artery when an angioplasty balloon failed to deflate, and one patient suffered a skin reaction thought to be due to inadequate removal of the sterilizing solution. A different sterilizing procedure is now followed. Laser angioplasty can reduce the number of patients requiring bypass surgery and improvements in the device and access methods may reduce the number of untreatable cases.

Adult

Assessment of a new device for laser angioplasty.

Experimental work has shown that a transparent laser device delivering pulsed energy to an artery results in a smaller area of surrounding damage than does an opaque device with a continuous wave laser. The combination of a transparent ball-tipped device with a pulsed Nd-YAG laser has been investigated. The system delivers pulses of 100 microseconds at a rate of 10 Hz and average energy of 0.5 J per pulse with an energy loss of 5-10% between the output at the laser rail and the fibre tip. The dose/response was measured and showed that on normal aorta under saline the device produces craters with a depth of 5 microns/J and 1.5 mm radius. There is a 100% increase in dose response with diseased aorta and a 50% increase when exposure is carried out under blood. The effect of a varying angle of incidence upon the arterial wall has been measured. Angulation of the device at 10 degrees from the perpendicular reduces the crater depth to 50%, as compared with a 50% reduction at 60 degrees using a bare fibre. As estimated with a thermal camera in air, the device heats up to a maximum of 50 degrees C during a 50 J exposure, compared to 110 degrees C after 5 J for the sapphire device. Artificial circulation experiments were carried out using diseased femoral vessels occluded by a ligature. The new system recanalised 100% of occlusion in straight vessels, and 40% of occlusions in curved vessels at a radius of 2.5 cm.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Perforation thresholds and safety factors in in vivo coronary laser angioplasty.

Laser angioplasty can cause early (acute perforation) or late (stenosis or aneurysm) complications. To find how much intravascular laser energy can be delivered via a 100 microns core optical fibre passed down a balloon angioplasty catheter without causing angiographic abnormalities up to 10 days later, argon laser energy was delivered percutaneously under radiographic screening to the coronary circulation of 12 normal closed chest dogs. With the balloon inflated, sequential laser pulses were delivered to the same site. Angiograms were recorded before, immediately, and again at one week, after laser delivery. There were two laser-induced perforations (both fatal). Mechanical perforation with the 100 microns fibre occurred four times, but there were no haemodynamic sequelae. To find the acute perforation threshold of similar sized arteries to energy delivered via the bare 100 microns core fibre, the tip of which was held in contact with the luminal surface, 32 argon laser pulses were delivered transluminally in vivo to separate sites in normal rabbit iliac and canine coronary arteries. The acute perforation threshold with energy delivered via the angioplasty catheter lay between 6 and 10 J and that without the balloon angioplasty catheter lay between 3 and 4 J. After delivery of up to 6 J via a balloon angioplasty catheter, there were no angiographic abnormalities at one week. Fibre optic transluminal delivery of laser energy may improve the primary success rate of, and perhaps widen the indications for, coronary angioplasty.

Angioplasty, Balloon

Arterial healing in the dog after intraluminal delivery of pulsed Nd-YAG laser energy.

The application of laser energy to percutaneous recanalization of diseased blood vessels is of interest to vascular surgeons and radiologists. We have examined the effect of pulsed infrared light from a 100 microseconds pulsed Nd-YAG laser on the dog aorta in order to determine the dose response, perforation thresholds and healing properties in vascular tissue. We used 100 microseconds pulses of 0.5 J energy at 10 Hz repetition rate via a 400 micron optical fibre to make 205 craters in 10 dogs at total energies of 5-25 J. The perforation threshold was 15 J in six animals and 20 J in four. The dose response was linear at 10 micron tissue vaporized per Joule delivered. Animals were killed immediately and at intervals of 24 h, 4, 7 and 10 days, 2, 3 and 6 weeks, and 3 and 6 months. Material was retrieved for histology and examined by light and scanning electron microscopy. The tissue exhibited features of laser damage that were less marked than those seen with continuous wave lasers; there was less heat damage surrounding the craters which healed well, even after perforation. This laser is likely to be suitable for human laser angioplasty provided the energy is given in increments of 15 J or less.

Animals

The physical properties of tissue ablation with excimer lasers.

The current controversy regarding the interaction between the output of the excimer laser and human tissue concerns the relative importance of photothermal and photoablative effects. Two experiments using an excimer laser on vascular tissue, aimed at defining the precise laser-tissue interaction, were performed. The experiments argue strongly in favor of photoablative effects that result from multiple photon interactions with ablated tissue.

Arteriosclerosis

Optical transmission of normal and atheromatous arterial wall: a spectral analysis.

In laser angioplasty one of the factors influencing the immediate damage (and therefore the risk of acute arterial perforation) is the optical absorption characteristics of the target tissue. In an attempt to evaluate the differences in optical absorptive properties, the transmission spectrograms of samples of normal and atheromatous human postmortem aortic wall were measured over the visible spectrum. Optical transmission varied inversely with sample thickness and directly with wavelength through both normal and atheromatous samples. Over the whole visible spectrum atheromatous tissue transmitted less per unit thickness than normal tissue. This differential effect was, however, most pronounced at 500 nm, where atheromatous tissue transmitted light 5-10 times less strongly than normal aortic wall. Such wavelength dependent differential optical absorption could provide a means for the selective photovaporisation of atheroma in laser angioplasty.

Angioplasty, Balloon