Cardiac imaging at 4 Tesla.

Although higher magnetic field strength is a means to increase SNR in MRI, cardiac imaging has been difficult at high fields due to decreased RF penetration. Using a tailored cardiac coil constructed of two transmit surface coils with a four-element multicoil for signal reception, the authors demonstrate high-quality heart images acquired on a 4-T scanner. These images show an increase in SNR of approximately 2.5-fold over imaging at 1.5 T. This improvement in image quality can be used to increase in-plane resolution, reduce slice thickness, or reduce total scan time. Magn Reson Med 45:176-178, 2001.

Heart↗

A spiral volume coil for improved RF field homogeneity at high static magnetic field strength.

Biological samples have a high dielectric constant that can shorten RF wavelengths by a factor of 8 relative to the vacuum. At high field strengths, finite wavelength effects within larger samples are the dominant cause of RF field nonuniformity. A coil design is presented that can reduce and even eliminate this inhomogeneity; 4-T images in phantoms and in the head of a normal volunteer are presented, which demonstrate improved homogeneity relative to a standard coil. This coil design should aid in realizing the potential advantages of imaging large samples at high field strengths.

Anatomy, Cross-Sectional↗

Multicoil array for high resolution imaging of the breast.

An RF multicoil array for high resolution imaging of the breast is presented. The RF multicoil is incorporated into a dedicated breast imaging apparatus that holds either breast in gentle compression during imaging. Simulations and imaging experiments demonstrate the high sensitivity and RF homogeneity of the multicoil array. Direct comparisons are made between the multicoil and a surface coil. In vivo images are presented to demonstrate the homogeneity of the RF field of the multicoil over the entire breast. An in vivo image of both high temporal and spatial resolution is shown, which demonstrates the sensitivity of the RF multicoil array that may be achieved in a practical imaging experiment.

Adult↗

Optimization of torque-balanced asymmetric head gradient coils.

Local gradient coils can improve the performance of echo-planar, diffusion, and short TE imaging in the brain. A modified singular value decomposition algorithm, which allows the rapid optimization and comparison of designs, was employed to optimize head size gradient coils. A theoretical expression for the torque on a cylindrical coil is presented and used to design coils that are free from torque while pulsed within a magnetic field. Gradient coils of various lengths both with and without torque constraints were compared; although torque-free coils do not perform as well as unbalanced coils, asymmetric torque-balanced coils can achieve comparable homogeneity with only a modest increase in inductance and resistance. Both types of coils outperform body size gradient coils by a dramatic margin. A three-axis head gradient designed using these techniques was constructed and used for brain imaging on a clinical scanner.

Brain↗

An improved quadrature or phased-array coil for MR cardiac imaging.

A tailored receive-only coil for cardiac imaging has been designed. The coil consists of two overlapping coil elements and can be used either as a quadrature surface coil or as a phased-array coil. Through phantom experiments and images of the heart, the authors have shown that the improved cardiac coil provided a signal-to-noise ratio 1.6 times higher than a conventional quadrature spine coil, 1.4 times higher than that of a single coil (having the same shape and total dimension), and three times higher than the body coil at the depth of the posterior wall of the heart. The authors have also shown that the cardiac coil improved image quality everywhere in the heart. This coil will enhance routine clinical cardiac studies as well as other examinations such as myocardial perfusion, wall motion, and coronary artery imaging.

Artifacts↗

Quantification of the volume of articular cartilage in the metacarpophalangeal joints of the hand: accuracy and precision of three-dimensional MR imaging.

OBJECTIVE: Cartilage loss is central to the development of joint failure in arthritis. However, radiographic assessment of cartilage loss is highly unreliable. This study examined the accuracy and reproducibility of a noninvasive technique for quantifying the volume of articular cartilage in the metacarpophalangeal joints of the hand by use of three-dimensional (3D) MR imaging. SUBJECTS AND METHODS: Eight metacarpophalangeal joints (four normal, one rheumatoid arthritic, and three normal cadaveric) each were imaged three times with a 1.5-T clinical MR imaging scanner with a small partial volume coil and a fat-saturated 3D spoiled gradient-echo sequence optimized for delineating articular cartilage. The volumes of cartilage over the metacarpal and phalangeal surfaces were quantified by summing the voxels within segmented 3D reconstructions of the images. Cartilage volumes in the three cadaver joints also were estimated by scraping cartilage off the articular surfaces and measuring water displacement in graduated cylinders. These values were used as the gold standard for assessing the accuracy of cartilage volume quantification by MR imaging. RESULTS: The fat-saturated sequence discriminated the articular cartilage from adjacent joint structures with high contrast and high spatial resolution. Cartilage volumes determined by MR imaging for the different subjects ranged from 115 microliters to 222 microliters for metacarpal cartilage and from 34 microliters to 86 microliters for proximal phalangeal cartilage. Accuracy errors for quantifying cartilage volume by MR imaging were -1.8% (95% confidence interval, -3.5% to -0.7%) for metacarpal cartilage and 9.1% (4.3% to 14.7%) for proximal phalangeal cartilage. Reproducibility errors were 5.2% (95% confidence interval, 2.9% to 7.6%) and 9.9% (5.4% to 15.1%), respectively. CONCLUSION: Fat-suppressed T1-weighted 3D MR imaging provides sufficient contrast and spatial resolution to allow accurate and reproducible quantification of articular cartilage volume in the metacarpophalangeal joints of the hand. This technique may be useful for monitoring cartilage loss in patients with arthritis.

Adult↗

Phosphorus-31 nuclear magnetic resonance studies of complexes of thymidylate synthase.

The interactions of thymidylate synthase (TS) with deoxyuridylate (dUMP), deoxythymidylate (dTMP) and 5-fluorodeoxyuridylate (FdUMP) were examined by 31P-NMR. Single 31P resonances appeared at 3.3 ppm, 3.2 ppm and 3.0 ppm from the standard, 85% phosphoric acid, for unbound dUMP, dTMP, and FdUMP, respectively. Incubation of the enzyme with either dUMP or dTMP, alone, resulted in new resonances at 3.9 and 3.6 ppm, respectively, which were assigned to noncovalent complexes with the enzyme. The same experiment employing FdUMP as the ligand gave two new resonances appearing at 3.6 and 4.6 ppm, which were attributed to noncovalent and covalent binary complexes, respectively. When the cofactor, CH2H4 folate, was present in the solution with enzyme and FdUMP, a new resonance appeared at 5.1 ppm, corresponding to the covalent inhibitory ternary complex. The ternary complex comprised of the enzyme, dUMP and the quinazoline folate CB 3731 produced a resonance at 5.0 ppm at the expense of the resonance due to the enzyme-dUMP binary complex at 3.9 ppm. Similarly, the ternary complex consisting of TS with dTMP and CB 3731 showed a deshielding of the resonance at 3.6 ppm by 0.8 ppm. A maximum binding of 1.5 nucleotides per enzyme dimer was found for dUMP and dTMP in both the presence and the absence of the quinazoline folate. The deshielding observed was attributed to changes in the interaction of the phosphate group with the nearby residues of the active site of the enzyme.

Deoxyuracil Nucleotides↗

MR guided biopsy of the breast.

This article examines technical and clinical issues related to MR guided biopsy of the breast. Designed features of breast biopsy instrumentation are discussed. Procedures for performing breast biopsies as well as clinical indications are also explored.

Biopsy, Needle↗

Fluorine-19 nuclear magnetic resonance studies of binary and ternary complexes of thymidylate synthase utilizing a fluorine-labeled folate analogue.

Traditional fluorine-19 nuclear magnetic resonance (19F NMR) studies of thymidylate synthase (TS) have utilized the fluorine substituent of 5-fluorodeoxyuridine 5'-monophosphate (FdUMP), a mechanism-based inhibitor of the enzyme, in complexes with various folate and folate analogues in order to establish a paradigm for the formation of binary and ternary complexes. In order to extent and confirm this paradigm, complexes of thymidylate synthase (TS) and the N-10-(fluoroethyl)quinazolinylfolate analogue CB3731 with either deoxyuridine 5'-monophosphate (dUMP), deoxythymidine 5'-monophosphate (dTMP), or FdUMP were examined from the perspective of the folate analogue using 19F NMR. The spectrum of the free folate analogue gave rise to a multiplet centered at -57.0 ppm, which was broadened by approximately 50% upon incubation with the enzyme. The use of FdUMP with CB3731 afforded us the opportunity to compare the spectrum obtained for the folate with that of the nucleotide. This comparison led to the assignment of the resonance at -53.5 ppm as representing the noncovalent TS:FdUMP:CB3731 ternary complex, while a new resonance at -52.0 ppm corresponded to the species in which the nucleotide is covalently attached to the enzyme and the folate is noncovalently associated. Ternary complexes consisting of TS, CB3731, and either dUMP or dTMP displayed a resonance at -53.5 ppm which represented the noncovalent TS-nucleotide adduct. None of the TS:nucleotide:CB3731 ternary complexes, however, was stable to native polyacrylamide gel electrophoresis.

Fluorine↗