PubMed HealthSearch

Biomedical subjects

T J Cullip

Publications and source records attributed to T J Cullip.

6 recordsLinked to original sources

Image registration: an essential part of radiation therapy treatment planning.

PURPOSE: We believe that a three-dimensional (3D) registration of nonplanning (diagnostic) imaging data with the planning computed tomography (CT) offers a substantial improvement in tumor target identification for many radiation therapy patients. The purpose of this article is to review and discuss our experience to date. METHODS AND MATERIALS: We reviewed the charts and treatment planning records of all patients that underwent 3D radiation treatment planning in our department from June 1994 to December 1995, to learn which patients had image registration performed and why it was thought they would benefit from this approach. We also measured how much error would have been introduced into the target definition if the nonplanning imaging data had not been available and only the planning CT had been used. RESULTS: Between June 1994 and December 1995, 106 of 246 (43%) of patients undergoing 3D treatment planning had image registration. Four reasons for performing registration were identified. First, some tumor volumes have better definition on magnetic resonance imaging (MRI) than on CT. Second, a properly contrasted diagnostic CT sometimes can show the tumor target better than can the planning CT. Third, the diagnostic CT or MR may have been preoperative, with the postoperative planning CT no longer showing the tumor. Fourth, the patient may have undergone cytoreductive chemotherapy so that the postchemotherapy planning CT no longer showed the original tumor volume. In patients in whom the planning CT did not show the tumor volume well an analysis was done to determine how the treatment plan was changed with the addition of a better tumor-defining nonplanning CT or MR. We have found that the use of this additional imaging modality changed the tumor location in the treatment plan at least 1.5 cm for half of the patients, and up to 3.0 cm for 1/4 of the patients. CONCLUSIONS: Multimodality and/or sequential imaging can substantially aid in better tumor definition in many patients undergoing 3D treatment planning. In some patients the appropriate nonplanning imaging source can change the perceived tumor location by several centimeters and is thus essential for proper treatment planning.

Humans

Improving treatment planning accuracy through multimodality imaging.

PURPOSE: In clinical practice, physicians are constantly comparing multiple images taken at various times during the patient's treatment course. One goal of such a comparison is to accurately define the gross tumor volume (GTV). The introduction of three-dimensional treatment planning has greatly enhanced the ability to define the GTV, but there are times when the GTV is not visible on the treatment-planning computed tomography (CT) scan. We have modified our treatment-planning software to allow for interactive display of multiple, registered images that enhance the physician's ability to accurately determine the GTV. METHODS AND MATERIALS: Images are registered using interactive tools developed at the University of North Carolina at Chapel Hill (UNC). Automated methods are also available. Images registered with the treatment-planning CT scan are digitized from film. After a physician has approved the registration, the registered images are made available to the treatment-planning software. Structures and volumes of interest are contoured on all images. In the beam's eye view, wire loop representations of these structures can be visualized from all image types simultaneously. Each registered image can be seamlessly viewed during the treatment-planning process, and all contours from all image types can be seen on any registered image. A beam may, therefore, be designed based on any contour. RESULTS: Nineteen patients have been planned and treated using multimodality imaging from November 1993 through August 1994. All registered images were digitized from film, and many were from outside institutions. Brain has been the most common site (12), but the techniques of registration and image display have also been used for the thorax (4), abdomen (2), and extremity (1). The registered image has been an magnetic resonance (MR) scan in 15 cases and a diagnostic CT scan in 5 cases. In one case, sequential MRs, one before treatment and another after 30 Gy, were used to plan patient's initial fields and boost, respectively. Case illustrations are shown. CONCLUSIONS: We have successfully integrated multimodality imaging into our treatment-planning system, and its routine use is increasing. Multimodality imaging holds out the promise of improving treatment planning accuracy and, thus, takes maximum advantage of three dimensional treatment planning systems.

Humans

The tetrad and hexad: maximum beam separation as a starting point for noncoplanar 3D treatment planning: prostate cancer as a test case.

PURPOSE: In contrast to computer optimized three-dimensional (3D) treatment planning, we have used maximally separated, noncoplanar beams as the starting point for 3D treatment planning of prostate cancer to maximize the rate of dose fall off from the target volume and minimize dose to surrounding tissues. MATERIALS AND METHODS: A planar four-field plan, a planar six-field plan, a tetrad plan, and a hexad plan are analyzed using a 3D treatment planning system which is capable of displaying real-time 3D dose distributions within volume reconstructed data sets (VISTAnet--an extension of the virtual simulator). The tetrad plan is based on the methane molecule and the hexad plan has a minimum separation of 58 degrees on beam entrance. All fields are conformal. The irradiated volume equals the clinical target volume plus a 1 cm margin. Competing plans are compared using cumulative dose-volume histograms and normal tissue complication probabilities. RESULTS: The crossover point, the isodose surface that conforms more to the beams than the target, is introduced and described. The hexad and tetrad plans result in tighter dose distributions when compared to the planar plans with the same number of beams. The tetrad plan treats a volume less than or equal to the planar six-field plan at isodose surfaces above 18% except between 37% and 44% where the tetrad volume is slightly larger. As expected from integral dose considerations, the amount of normal tissue receiving some radiation increases, but the amount receiving clinically significant amounts of radiation decreases as the number of beams increase. The plan involving the largest number of noncoplanar beams results in the tightest isodose distribution. Analysis of rectal and bladder cumulative dose volume histograms does not reveal a clearly superior plan based on normal tissue complication probabilities. CONCLUSIONS: Using basic principles of solid geometry, maximally separated beams without significant overlap on exit or entrance can be designed which minimize clinically significant dose to surrounding tissues and tighten the isodose distribution around the target volume. The emphasis of this treatment plan optimization is geometric in contrast to methods using computer optimization or artificial intelligence.

Humans

A Monte Carlo study of accelerator head scatter.

The production of off-focus x rays in the head of a 6 MV linac has been investigated using the EGS4 Monte Carlo code. The purpose of the study was to identify the sources of off-focus radiation and the relative contribution for each source. Even though a particular energy and linac were modeled, the broad conclusions are expected to be general since the effects of head scatter are similar for most conventional head designs, regardless of manufacturer, energy, and model. The head components that were modeled include the exit window of the accelerating structure, target, beam stopper, flattening filter, monitor chamber, primary and secondary collimators, and air. Monoenergetic 6 MeV electrons were followed through the exit window, target, and beam stopper until all energy was expended. Primary- and higher-order x rays produced throughout the head were followed until they were either absorbed or passed through a plane at the isocenter. Sites of off-focus radiation were found to be diffusely distributed throughout the head, with the most intense sources being the primary collimator, flattening filter, and beam stopper. Data analysis shows that the collimator effect is determined primarily by the volume of the extended head-scatter source that is exposed to the point of measurement through the collimating system. The results of this study provide a rationale for developing extended source models to calculate the collimator factor for fields defined by arbitrary collimation. An additional advantage is an improvement in the agreement between measured and calculated isodose distributions.

Energy Transfer

Digitally reconstructed fluoroscopy and other interactive volume visualizations in 3-D treatment planning.

PURPOSE: Add radiographic context to the beam's-eye-view used in 3-dimensional treatment planning. Improve methods for interactive visualization of anatomy and dose distributions. METHODS AND MATERIALS: Most 3-dimensional treatment planning systems feature a beam's-eye view that includes only graphical representations of patient anatomy. With input devices such as a mouse or trackball, the user interactively shapes the treatment field using the graphical models to provide geometric information. Radiographic context provides additional geometric information important for determining field shape. We have implemented digitally reconstructed fluoroscopy in the beam's-eye view by increasing the efficiency for computing digitally reconstructed radiographs. In addition we have improved algorithms for real-time surface and volume rendering for anatomy and doses using an experimental graphics supercomputer. RESULTS: Without radiographic context in the beam's-eye-view, field shapes were sometimes changed after simulation or portal images were obtained. Digitally reconstructed fluoroscopy has essentially eliminated these changes. Higher quality interactive three-dimensional displays improve the comprehension, confidence and efficiency of the user. Our improvements have already been implemented on one model of a new generation of commercial graphics workstations. CONCLUSION: Addition of radiographic context to the beam's-eye-view is recommended. Incorporation of higher quality interactive graphics is rapidly becoming practical and is encouraged.

Computer Simulation

VISTAnet: interactive real-time calculation and display of 3-dimensional radiation dose: an application of gigabit networking.

Three-dimensional treatment planning can allow the clinician to create plans that are highly individualized for each patient. However, in lifting the constraints traditionally imposed by 2-dimensional planning, the clinician is faced with the need to compare a much larger number of plans. Although methods to automate that process are being developed, it is not yet clear how well they will perform. VISTAnet is a 3 year collaborative effort between the Departments of Radiation Oncology and Computer Science at the University of North Carolina, the North Carolina Supercomputing Center, BellSouth, and GTE with the medical goal of providing real-time 3-dimensional radiation dose calculation and display. With VISTAnet technology and resources, the user can inspect 3-dimensional treatment plans in real-time along with the associated dose volume histograms and can fine tune these plans in real-time with regard to beam position, weighting, wedging, and shape. Thus VISTAnet provides an alternate and, possibly, complementary approach to computerized searches for optimal radiation treatment plans. Building this system has required the development of very fast radiation dose code, methods for simultaneously manipulating and modifying multiple radiation beams, and new visualizations of 3-dimensional dose distributions.

Computer Communication Networks