Correction regarding an adverse reaction to the recombinant hepatitis B vaccine.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to T J Hudson.
Explore the source record for details and available documents.
Expansion of trinucleotide repeats can give rise to genetic disease. We have developed a technique, repeat expansion detection (RED), that can identify potentially pathological repeat expansion without prior knowledge of chromosomal location. Human genomic DNA is used as a template for a two-step cycling process that generates oligonucleotide multimers when expanded trinucleotide sequences are present at the level found in myotonic dystrophy and fragile-X patients. We have identified at least one new locus exhibiting trinucleotide expansion. Analysis of three families transmitting a long CTG repeat shows that the allele in these families corresponds to a locus on chromosome 18. RED constitutes a powerful tool to identify other diseases caused by this mechanism, particularly diseases associated with anticipation.
Explore the source record for details and available documents.
One hundred highly informative simple sequence repeat (SSR) polymorphisms have been isolated and mapped to specific human chromosomes by somatic cell hybrid analysis. These markers include 97 (CA)n, 2 (AGAT)n, and a single (AACT)n repeat. All the SSRs have heterozygosities greater than 0.50 and can be amplified using identical PCR conditions. At least one SSR was detected on every chromosome, except for chromosomes 22 and Y. The frequency of (CA)n repeats on each chromosome was proportional to the relative chromosomal length, except for chromosome 15, on which a substantial excess of markers was identified.
Explore the source record for details and available documents.
A high-performance liquid chromatographic procedure was developed for the analysis of calcium pantothenate in nutritional supplements. The method involves a simple extraction using phosphate buffer and sonication. Chromatographic separation is obtained using an aminopropyl-loaded silica gel column in the reverse-phase mode. A UV detector set at 210 nm was used to monitor the effluent. Quantitative recoveries were obtained, and precision of the method is discussed. The method is applicable to multivitamin tablets, calcium pantothenate raw material, and yeast grown in the presence of high levels of calcium pantothenate. The results of the method are compared with results obtained from the USP microbiological method of analysis. It was concluded that the procedure is rapid, accurate, easily automated, and practical for routine quality control use.
OBJECTIVE: To test for potential bacterial contamination of the ADD-Vantage system when the components are assembled in various hospital environments. STUDY DESIGN: One hundred fifty ADD-Vantage units were assembled by three different people in three separate locations within a hospital. Each person assembled ten units per day; the study spanned five days. After 72 hours of incubation, units were inspected for evidence of contamination. SETTING: ADD-Vantage units were assembled by a pharmacist in a laminar-flow hood, a pharmacy student using the pharmacy counter, and a nurse at a patient's bedside table. Personnel at each site wore their regular work attire. Each person observed handwashing techniques normally used during routine working hours. DATA EXTRACTION: Positive results were sent to the hospital microbiology laboratory for determination of growth type. RESULTS: After 72 hours, none of the systems exhibited microbial growth on visual inspection. No differences in microbial contamination of the ADD-Vantage systems relative to assembly site, day of assembly, or person performing the assembly were observed. The incidence of contamination was calculated at less than seven percent. CONCLUSIONS: There is minimal risk of bacterial contamination when ADD-Vantage systems are compounded either on a pharmacy counter or at a patient's bedside. Larger samples must be studied in order to detect differences in the incidence of contamination among assembly sites.