PubMed Health⌕ Search

Biomedical subjects

T J Spinks

Publications and source records attributed to T J Spinks.

40 records · Page 3Linked to original sources

Neutron-activation measurement of metabolic activity of sodium in the human hand.

Turnover of sodium in the human hand was studied by neutron activation. One hand of each subject was irradiated with a 1.5-rad dose of partially thermalized fast neutrons. The activity of 24Na was measured at intervals from 3 min to 48 hr after irradiation. The loss of sodium from the hand during this period can be described either by two exponentials or by a single power function. The latter description involves only two disposable factors compared with four in the former. The rate of loss of sodium was found, on the average, to be greater in patients suffering from bone disease than in normal subjects. Neutron activation is a powerful method for studying sodium turnover because the sodium atoms are labeled simultaneously and with equal probability, regardless of the turnover time of individual bodily compartments.

Adult↗

Influence of intravascular activity on the determination of blood flow and oxygen extraction in normal and ulcerated legs using the 15O steady-state technique and positron emission tomography.

An analysis using the 15O steady-state inhalation technique has been carried out into the effects of correction for intravascular activity on the determination of blood flow and oxygen extraction ratio (OER) in the legs of patients affected by ulceration. Transaxial images of the distribution of activity in a plane passing through the ulcer were obtained during steady-state inhalation of C15O2 and 15O2, respectively, using a single slice positron emission tomographic scanner. From these, the basic tracer model equations were solved to obtain blood flow and oxygen extraction with and without additional correction for the presence of intravascular activity. The latter was obtained from a scan following the inhalation of a tracer quantity of 11CO, which labels the red blood cell pool. Mean blood flow and OER in ulcerated regions were 0.087 ml/ml/min and 0.33, respectively. With correction for blood volume, assumed to be all venous, the mean OER decreased to 0.12. In the "mirror" region of normal legs mean blood flow was 0.011 ml/ml/min with uncorrected and corrected OER values of 0.87 and 0.75, respectively. The effect of assuming a nonzero arterial volume increases as flow and OER decrease but is uncertain due to the unknown arterial fraction. Correction for intravascular 15O is essential and generally the assumption that all blood volume is venous is adequate.

Humans↗

Physical aspects of cardiac scanning with a block detector positron tomograph.

Physical aspects relating to cardiac scanning are described for an eight ring (15 plane) positron tomograph consisting of BGO block detectors (CTI/Siemens 931-08/12). Performance parameters were derived from a cylindrical heart phantom having a "myocardial" wall of thickness varying from 3 mm to 27 mm. This phantom was inserted into a chest phantom consisting of simulated chest wall, lungs, and arms. Recovery coefficients for myocardial thicknesses of 10 mm and 15 mm were 0.75 and 0.9, respectively. Division by the transmission minus "blood pool" (extravascular density) image was found to give a variation of corrected myocardial counts within +/- 5% when transmission data were smoothed. The on-line dead time correction algorithm was found to be accurate to within 5% up to 20 mCi (740 MBq) in the axial field of view (FOV) (10.8 cm) in the central chamber of the heart phantom. However, the correction factor at this rate is approximately 3, which would imply poor use of administered dose. Counts in the image due to scatter are approximately 2% in the (cold) central cavity of the heart phantom relative to counts/pixel in the active myocardium. The presence of phantom arms in the FOV was found to have only a small effect on mean pixel counts and noise in the heart phantom image, as did movement of the arms within a reasonable range.

Calibration↗