PubMed Health⌕ Search

Biomedical subjects

T Jakobs

Publications and source records attributed to T Jakobs.

4 recordsLinked to original sources

[Liver tumor ablation].

Minimal-invasive techniques for ablation of primary and secondary hepatic tumors gain increasingly clinical importance. This is especially true since surgical resection and classic chemotherapy is successful only in a limited number of patients. Local ablative methods incorporate chemo- (percutaneous alcohol instillation, transarterial chemoembolization), thermo- (radiofrequency-, laser-, microwave-, cryoablation, high intensive focused ultrasound) and radio-ablative techniques (interstitial brachytherapy, selective internal radiotherapy). Regarding their implementation and specific effects these methods are varying widely, nevertheless all of them have a high therapeutical efficacy together with a low complication rate in common-correct application presumed. The knowledge on specific indications and contraindications is crucial to implement these methods into multimodality therapy concepts.

Brachytherapy↗

Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose.

The aim of the study was to implement an abdominal CT angiography protocol using 100 kVp and to compare SNR and CNR, as well as subjective image quality, to a standard CT angiography protocol using 120 kVp on a 16 detector-row CT scanner. Forty-eight patients were referred for routine abdominal CT angiography on a 16 detector-row CT scanner. Patients were scanned using either 120 or 100 kVp at constant mAs settings. Vessel opacification was provided by automated contrast injection using similar injection protocols. Density measurements were performed along the aorto-iliac axis with SNR and CNR calculation. In addition, the estimated effective patient radiation dose was calculated. Results of both protocols were compared. The 100-kVp protocol (432+/-80 HU) showed a significantly higher vessel density than the 120-kVp (333+/-90 HU; P<0.001) protocol, corresponding to an average increase in signal intensity of 30.7%. SNR (36.0 vs 37.0) and CNR (31.1 vs 31.7) for the 100-kV protocol were not significantly lower that those for the standard protocol (P=0.79 and P=0.87), whilst the average estimated dose was significantly lower using the 100-kVp protocol (6.7+/-0.4 vs 10.1+/-1.2 mSv; P<0.0001). Tube kVp reduction from 120 to 100 kVp allows for significant reduction of patient dose in abdominal CT angiography, without significant change in SNR,CNR and image quality.

Adult↗

[Methods of quantification of coronary artery calcifications with electron-beam and conventional computed tomography].

PURPOSE: To compare electron beam CT (EBCT) und prospectively ECG gated conventional CT for the detection and quantification of coronary artery calcifications. METHODS: 42 patients (mean age 62.8 +/- 8.8 years) were scanned, both with EBCT and ECG gated sequential CT. For quantification, the traditional "total calcium score" (TCS) according to the Agatson method as well as the "volumetric calcium score" (VCS) as determined with a stand-alone workstation (NetraMD) was calculated for both modalities. RESULTS: There was close correlation between EBCT and conventional CT, both for TCS (r = 0.984) as well as for VCS (r = 0.986) score values. The median difference was 17% for TCS and 13% for VCS. The difference between the two modalities was not statistically significant (p = 0.44). CONCLUSION: EBCT and prospectively ECG triggered conventional CT are equivalent for the quantification of coronary artery calcifications. The extent of calcifications can be established with both modalities using either TCS or VCS score values.

Age Factors↗

Trunk position sense in the frontal plane.

Twenty healthy volunteers (ages 18 to 25 years) were tested for their ability to sense the lateral position of the top of their thoracic spine. When moved slowly from side-to-side in the frontal plane with vision occluded and pelvis immobilized, they could sense the position of a midline point on the skin at the T1 level to within 3 mm of a mean center position in relaxed standing tests, and to within 9 mm in supine tests. When subjects centered themselves actively, or additionally, contracted trunk flexor or extensor muscles to predetermined levels of activity, no increase in trunk positioning accuracy was found. The effect of a lateral pelvic tilt or lateral trunk moment had little effect on trunk positioning accuracy, but always induced a characteristic trunk offset. No differences were found in any of these results between males or females, or gymnasts or nongymnasts.

Adolescent↗