PubMed Health⌕ Search

Biomedical subjects

T K Abboud

Publications and source records attributed to T K Abboud.

At least 19 recordsLinked to original sources

Rapacuronium for modified rapid sequence induction in elective caesarean section: neuromuscular blocking effects and safety compared with succinylcholine, and placental transfer.

We have compared rapacuronium 2.5 mg kg-1 (n = 20) with succinylcholine 1.5 mg kg-1 (n = 22) in a multicentre, blinded, randomized study in full-term parturients undergoing elective Caesarean section under general anaesthesia. Thiopental 5 mg kg-1 was given i.v. followed by the neuromuscular blocking agent. Sixty seconds later intubation was performed. Intubating conditions, evaluated as excellent, good or poor, were good to excellent in 95% and 91% in the intent-to-treat patients after rapacuronium and succinylcholine, respectively (ns). Mean onset times at the adductor pollicis muscle for rapacuronium and succinylcholine were 80.4 (SEM 14.4) s and 63.9 (5.6) s (ns) while maximum block was 96 (1.9)% and 99 (0.4)%, respectively (ns). Rate of recovery was significantly longer after rapacuronium; times for return of T1 to 25% were 16.9 (1.5) min and 9.6 (1.1) min for rapacuronium and succinylcholine, respectively (P = 0.0004). Maternal side effects included more tachycardia and skin erythema with rapacuronium; no maternal mortality or morbidity, including bronchospasm, occurred in either group. There were no neonatal adverse effects in either group based on: Apgar scores at 1 and 5 min; times to sustained respiration; neuroadaptive capacity scores at 15 min, 2 h and 24 h; and umbilical venous and arterial blood-gas values and acid-base status. At delivery (17.7 (3.2) min), mean maternal plasma concentrations of rapacuronium were 9041.4 (1259.1) ng ml-1 and 506.4 (24.9) ng ml-1 for Org 9488 (the main metabolite). Corresponding values for umbilical venous plasma were 808.0 (92.1) ng ml-1 and 59.1 (6.5) ng ml-1, and for umbilical arterial plasma, 361.4 (56.4) ng ml-1 and 29.7 (4.6) ng ml-1, respectively. Umbilical venous to maternal venous ratios for rapacuronium and Org 9488 were 8.8% (1.3)% and 10.2 (1.7)%, respectively.

Adolescent↗

Systemic vascular resistance index determined by thoracic electrical bioimpedance predicts the risk for maternal hypotension during regional anesthesia for cesarean delivery.

OBJECTIVE: Our purpose was to evaluate the predictive value of the baseline systemic vascular resistance index for the development of maternal hypotension during regional anesthesia for cesarean delivery. STUDY DESIGN: Patients receiving a standardized spinal or epidural anesthetic for nonemergency cesarean delivery were studied prospectively. Hemodynamic data were obtained noninvasively with an NCCOM-3 cardiac output monitor (Bomed Medical Manufacturing, Irvine, Calif.), which uses thoracic electrical bioimpedance to estimate stroke volume and cardiac output. Measurements obtained were indexed to body surface area. The systemic vascular resistance index was calculated from mean arterial pressure and thoracic electrical bioimpedance-derived cardiac index. Hemodynamic data obtained were analyzed to identify statistically significant predictors of maternal hypotension. RESULTS: Maternal hypotension occurred in 24 of 42 (57%) patients studied. The incidence of hypotension did not differ between the types of anesthesia: spinal 17 of 274 (62%) versus epidural 7 of 15 (47%, p=0.48). The mean interval to the onset of hypotension was 12.2 minutes (SD 2.2 minutes, range 2 to 24 minutes). Mean (SD) baseline maternal systolic blood pressure was higher in patients who had hypotension (145 torr [4]) than those who did not (129 torr [4], p=0.01). The mean (SD) baseline systemic vascular resistance index was higher in patients who had hypotension (633 [SD 36] dyne . cm . sec-5/m2) than those who did not (454 [SD 29] dyne . cm . sec-5/m2; p =0.001). With receiver-operator characteristic curves, a baseline systemic vascular resistance index of 500 had a sensitivity of 83%, a specificity of 78%, a positive predictive value of 83%, and a negative predictive value of 78% for maternal hypotension (odds ratio 17.5, 95% confidence interval 3.1 to 109.4). A baseline systolic blood pressure of 140 torr had a sensitivity and specificity of 42% and 72%, respectively (odds ratio 1.9, 95% confidence interval 0.4 to 8.8). CONCLUSIONS: Baseline systemic vascular resistance index obtained by noninvasive cardiac output monitoring with thoracic electrical bioimpedance and systolic blood pressure are useful to predict the risk for maternal hypotension with regional anesthesia. Patients with increased baseline systemic vascular resistance index or systolic blood pressure are at increased risk for hypotension.

Adult↗

The efficacy of intrathecal injection of sufentanil using a microspinal catheter for labor analgesia.

Intrathecal sufentanil can provide labor analgesia. We investigated the efficacy of multiple injections and the maternal and neonatal effects of intrathecal sufentanil during labor. Seventeen healthy women in active labor received multiple injections of intrathecal sufentanil of 5 micrograms each through microspinal catheters. Overall maternal satisfaction of analgesia was quantified using 10 cm visual analogue scales and side effects were evaluated. Neonatal outcome was also determined. Onset of analgesia was less than 5 min after the first injection and lasted approximately 148 min. Tolerance developed for the successive injections. The mean onset times were 12.9 and 20.1 min and the durations were 76.6 and 33.9 min for the second and third injections, respectively (P < 0.05). Failure to obtain analgesia developed in all patients after the forth injection. No motor blockade was observed in any of the patients. Mild or moderate pruritus developed in 88% of the patients. Mean systolic blood pressure decreased by a maximum of 11.3% at 30 min and up to 90 min (P < 0.05) after the first injection; three patients required ephedrine treatment. No significant hemodynamic changes were observed after subsequent injections. Five patients experienced transient decrease in sensation. Neonatal status, as evaluated by Apgar scores, Neurological Adaptive Capacity Scores (NACS), fetal heart rate (FHR), and umbilical cord acid-base status, were within normal limits. Results from our study suggest that multiple small doses of sufentanil administered intrathecally provided satisfactory analgesia for parturients with short duration of labor since acute tolerance developed with multiple injections. High incidence of mild or moderate pruritus was observed during the study. Close attention should be given to hemodynamically unstable patients when this technique is applied.

Adult↗

Intravenous propofol vs thiamylal-isoflurane for caesarean section, comparative maternal and neonatal effects.

Several studies on propofol (Diprivan) for induction of anaesthesia during caesarean section have demonstrated its safety, however, it safety during maintenance of anaesthesia is not yet fully evaluated. The present study was undertaken to compare the maternal and neonatal effects of propofol or isoflurane in 74 term parturients undergoing primary or repeat caesarean section. Patients were randomly assigned to two groups, propofol group (n = 37) received propofol 1.5-2.5 mg.kg-1 for induction followed by a continuous infusion of propofol of 0.05-0.2 mg.kg-1.min-1. The isoflurane group (n = 37) received thiamylal 3-4mg.kg-1 for induction followed by isoflurane 0.25-0.75% for maintenance. All patients had rapid sequence induction using succinylcholine and endotracheal intubation, 50% N2O and O2 were used in all patients until delivery. After delivery N2O concentration was increased to 67% and intravenous butorphanol (Stadol) was given as needed. Patients in the propofol group had less hypertension after intubation (P < 0.05) and this was also of shorter duration compared to patients in the isoflurane group (5 min vs 10 min respectively). Maternal blood loss as well as intraoperative awareness and recovery time did not differ significantly between the two groups. Neonatal status as ascertained by Apgar scores, cord acid base status and the neurological and adaptive capacity scores (NACS) was equally good in both groups. It is concluded that propofol used for induction and maintenance of anaesthesia is a safe alternative to thiamylal/isoflurane for patients undergoing caesarean section and is associated with less hypertensive response during laryngoscopy and intubation.

Acid-Base Equilibrium↗

Desflurane analgesia for vaginal delivery.

The use of subanaesthetic concentration of inhalational anaesthetic for vaginal delivery offers many advantages to the mother and newborn. Desflurane, with the characteristics of rapid onset and minimal metabolism, may provide better analgesia and safety for labour pain control. Eighty healthy parturients were randomly assigned to receive either desflurane 1.0-4.5% and oxygen (n = 40) or nitrous oxide 30-60% in oxygen (n = 40). Analgesia was assessed using a score from 0 (no relief) to 4+ (excellent analgesia), amnesia for the delivery, blood loss were recorded. Neonates were evaluated by Apgar scores and neurologic and adaptive capacity scores (NACS). Data were analyzed for statistical significance using Student's t-test or Chi-square when appropriate. Analgesia scores were similar for both groups with more amnesia in desflurane group (23% vs 0% P < 0.05). Blood loss did not differ significantly, 364 ml for the desflurane group and 335 ml for the nitrous oxide group. There were no significant differences for neonatal Apgar score at 1 min or at 5 min or the NACS at 2 hr or 24 hr between the two groups. We conclude that desflurane in subanaesthetic doses is safe and effective inhalation agent for normal delivery but might be associated with amnesia.

Acid-Base Equilibrium↗

Desflurane: a new volatile anesthetic for cesarean section. Maternal and neonatal effects.

Desflurane, a new volatile anesthetic agent with low blood/gas solubility, has recently been studied in clinical and animal trials but its use in obstetrics has not been adequately evaluated. This prospective study was undertaken to evaluate the maternal and neonatal effects of desflurane in obstetrical patients. Seventy-five healthy parturients undergoing primary or repeat cesarean section were randomly assigned to one of three groups of 25 each, end-tidal 3% desflurane, 6% desflurane or 0.6% enflurane, combined with 50% N2O and O2. All patients had rapid sequence induction of anesthesia with thiopentone sodium followed by succinylcholine for tracheal intubation. After delivery, anesthesia was maintained with reduced concentration of desflurane or enflurane with 67% N2O in O2, supplemented by butorphanol tartrate. Maternal hemodynamic parameters, blood loss and maternal awareness during surgery were monitored. Neonatal outcome was evaluated by Apgar scores, neurological and adaptive capacity scores (NACS), cord blood gas and acid-base status, and time to sustained respiration (TSR). Maternal blood loss did not differ significantly between the three groups and none of the patients developed intraoperative awareness. All three groups responded to psychomotor performance equally fast. Patients in all three groups developed transient hypertension and tachycardia during induction of anesthesia which returned to baseline values in approximately 5 min. Neonatal outcome was equally good in the three groups. More neonates in the 6% desflurane group had TSR > 90 s compared to the 3% desflurane group (P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, Obstetrical↗

Transnasal butorphanol: a new method for pain relief in post-cesarean section pain.

This study was undertaken to evaluate the efficacy and the safety of transnasal butorphanol (TNB) compared to intravenous butorphanol (IVB) in 186 patients experiencing moderate to severe post-cesarean section pain. Patients were randomly assigned to five groups in a double-blind fashion: Group I (n = 37) received 2 mg IVB, Group II (n = 38) 2 mg TNB, Group III (n = 36) 1 mg TNB followed by a repeat dose of 1 mg TNB at 60 min, Group IV (n = 38) 0.5 mg TNB followed by a repeat dose of 0.5 mg at 60 min, and Group V (n = 37) received placebo. All administrations were double dummy. Pain intensity and relief were noted and the incidence of side effects was recorded. Remedication with the same study drug was allowed up to 72 h. Onset of analgesia was more rapid in the 2 mg IV group compared to the three TN groups: 5 min vs 15 min, respectively. However, the 2 mg and the 1-1 mg TN groups had a longer duration of analgesia, approximately 4.5 h, compared to 3.0 h for the 2 mg IV group (P less than 0.05). Somnolence was dose related and was the most frequent side effect, and was less frequent when the TN dose was divided into 2 doses administered 1 h apart. Multiple doses of TNB and IVB were safe and clinically acceptable up to 3 days at all doses studied. There were no incidences of nasal mucosa irritation, or cardiovascular or respiratory depression. It is concluded that transnasal butorphanol represents a safe and effective alternative to injectable butorphanol for post-cesarean section pain and offers a better and longer duration of analgesia compared to IV butorphanol. The optimum dose seems to be 2 mg TN butorphanol and it is tolerated better when divided into 1 mg increments, given 1 h apart.

Administration, Intranasal↗

Prophylactic oral naltrexone with intrathecal morphine for cesarean section: effects on adverse reactions and analgesia.

The influence of two different doses of oral naltrexone on the adverse effects and the analgesia associated with intrathecal morphine was compared in a double-blind, placebo-controlled study. Thirty-five patients undergoing cesarean section were provided postoperative analgesia by 0.25 mg intrathecal morphine. Sixty minutes later they were given 6 mg naltrexone, 3 mg naltrexone, or placebo as an oral solution. Pain relief was assessed by the Visual Analog Scale. Requirements for additional analgesics and side effects were recorded. Duration of analgesia was shorter in the 3- and 6-mg naltrexone groups than in the placebo group, 10.0 +/- 2.6, 12.4 +/- 2.6, and 19.2 +/- 4.5 h (mean +/- SEM), respectively, but values did not reach statistical significance. The incidence of pruritus and vomiting was significantly less in the 6-mg naltrexone group than in the other two groups (P less than 0.05). Somnolence was significantly less in the 3- and 6-mg naltrexone groups than in the placebo group (P less than 0.05). Naltrexone (6 mg) is an effective oral prophylactic against the pruritus and vomiting associated with intrathecal morphine for analgesia after cesarean section, but it is associated with shorter duration of analgesia.

Administration, Oral↗

Prophylactic oral naltrexone with epidural morphine: effect on adverse reactions and ventilatory responses to carbon dioxide.

The influence of two different doses of oral naltrexone on the adverse effects and the analgesia of epidural morphine were compared in a double-blind, placebo-controlled study. Forty-five patients undergoing cesarean section were provided postoperative analgesia with 4 mg epidural morphine. Five minutes later they received 6 mg naltrexone, 9 mg naltrexone, or placebo as an oral solution. Pain relief was assessed by the Visual Analog Scale (VAS) and by direct questioning of the patients. Requirement for additional analgesics and side effects were noted. Respiratory effects of epidural morphine and naltrexone were assessed using the ventilatory responses to CO2 and by monitoring O2 saturation (Spo2) using pulse oximetry. All patients in the placebo group had adequate analgesia. One of the 15 patients who received naltrexone 6 mg had inadequate analgesia versus five of the 15 patients who received naltrexone 9 mg (P less than 0.05), 9 mg versus placebo. Ten patients (67%) in the placebo group had pruritus while no patient in the 6 mg naltrexone group and one patient in the 9 mg group experienced mild pruritus (P less than 0.05), placebo versus other two groups. The CO2 response slopes were depressed compared to control values from 6-16 h in the placebo group, from 6-12 h in the 6 mg naltrexone group. No significant depression was noted in the 9 mg naltrexone group. The authors conclude that oral naltrexone 6 mg significantly reduces the incidence of pruritus associated with epidural morphine without affecting analgesia and that 9 mg naltrexone is associated with shorter duration of analgesia than 6 mg naltrexone.

Administration, Oral↗

Isoflurane or halothane for cesarean section: comparative maternal and neonatal effects.

The maternal and neonatal effects of isoflurane and halothane combined with 50% N2O - 50% O2 were compared in 60 healthy parturients undergoing primary or repeat cesarean section. All patients had rapid sequence induction of anesthesia with sodium thiamylal 4 mg/kg followed by succinylcholine for tracheal intubation. Patients were randomly assigned to one of three groups of 20 each (inspired 0.5% isoflurane, 1% isoflurane or 0.5% halothane), combined with 50% N2O and O2. After delivery, 67% N2O in O2 was used, supplemented by butorphanol. Maternal blood loss did not differ significantly among the three groups and none of the patients developed intraoperative awareness. At the time of delivery, maternal plasma epinephrine levels were significantly above preinduction levels in the 0.5% isoflurane group but unchanged in the other two groups. Neonatal status as ascertained by Apgar scores, cord acid base status and the Neurologic and Adaptive Capacity Scores (NACS) was equally good in the three groups of patients. Serum inorganic fluoride concentrations in the mother after anesthesia were not significantly above preanesthetic levels in any of the groups and there was no biochemical evidence of renal toxicity. In all neonates fluoride ion concentrations in the first voided urine sample were less than 7 mumol/l, a value well below that associated with nephrotoxicity. It is concluded that isoflurane is a safe supplement to N2O - O2 mixture for cesarean section and is a safer alternative to halothane in situations when patients receiving beta-adrenergic therapy require cesarean section since halothane might potentiate arrhythmias caused by beta adrenergic agonists.

Adult↗

Mini-dose intrathecal morphine for the relief of post-cesarean section pain: safety, efficacy, and ventilatory responses to carbon dioxide.

To determine the safety, efficacy, and the ventilatory responses to carbon dioxide (CO2) of mini-dose intrathecal morphine, 33 healthy women who underwent cesarean section with spinal anesthesia using 0.75% bupivacaine in 8.25% dextrose were studied. Patients were randomly assigned to receive, in a double-blind fashion, either morphine 0.25 mg (group I, n = 11), morphine 0.1 mg (group II, n = 10), or saline (group III, placebo group, n = 12) in 0.5 ml volume mixed with the bupivacaine. In both groups I and II excellent postoperative analgesia with long duration was obtained (27.7 +/- 4.0 and 18.6 +/- 0.9 hours, respectively, X +/- SEM). All patients in group III required an analgesic (8 mg subcutaneous morphine) within 3 hours of spinal anesthesia. Seven patients in group I and four patients in group II developed mild pruritus that did not require treatment. Ventilatory responses to CO2 showed no evidence of depression attributable to either the 0.25 or 0.1 mg of morphine, but significant depression of the CO2 responses was observed in group III patients after administration of subcutaneous morphine. It is concluded that a dose as low as 0.1 mg of intrathecal morphine gives excellent analgesia with minimal to no side effects and that subcutaneous morphine is associated with marked depression of the ventilatory variables.

Adult↗

Epidural and intrathecal administration of opioids in obstetrics.

Intraspinal epidural or intrathecal injection of opiates can provide outstanding analgesia in obstetric patients. Epidural and intrathecal opiates may afford more prolonged analgesia without interference of neuromuscular function or depression of the sympathetic nervous system that can occur with other anesthetic regimens. However, certain precautions are recommended to minimize potential side effects.

Anesthesia, Epidural↗