Management of a giant middle cerebral artery fusiform serpentine aneurysm with distal clip application and retrograde thrombosis: case report and review of the literature.

Giant fusiform aneurysms are rare vascular anomalies that due to their size are often difficult to manage. We describe one such aneurysm that was managed with a superficial temporal to middle cerebral artery bypass followed by the application of a single clip just distal to the vascular dilation. Follow-up angiography has shown aneurysm obliteration by the process of retrograde thrombosis.

Adult↗

Experimental determination of wall shear rate in canine carotid arteries perfused in vitro.

The mathematical model of Hung (Tsai and Hung, 1984) is employed to determine the wall shear rate acting on canine carotid arteries perfused in vitro. Model equations for pulsatile flow in a deformable vessel are coupled with experimental data of dynamic pressure drop, flow rate, vessel radius and radial wall motion. Derived quantities, e.g. velocity profiles and wall shear, are obtained for vessels exposed to 'normotensive' hemodynamics, 'hypertension' simulations and perfusions in which the compliance of the vessel wall is deliberately altered. Our results indicate that wall shear varies markedly as a function of the hemodynamic environment. The effects of vessel radius vs flow rate on the development of wall shear are also demonstrated. It is found that convective processes correlate with the magnitude of wall shear in the 'hypertension' simulations. The present findings and complementary published data may explain, at least in part, the variations in vessel wall transport and endothelial cell biology we observe as a function of the hemodynamic environment. For example we have documented that the exposure of canine carotids to 'hypertensive' (vs 'normotensive') hemodynamics is associated with an increased flux of lipoproteins (LDL) into the intima and luminal media. Alternations in wall compliance, on the other hand, profoundly influence endothelial shape, orientation and cytoskeletal array.

Animals↗

An in-vivo measurement and analysis of viscoelastic properties of the spinal cord of cats.

An in-vivo experimental technique was employed to determine the linear and nonlinear characteristics of viscoelastic properties of the spinal cord of anesthetized cats. The stress relaxation and recovery curves were reproducible in a group of cat experiments. The data of linear viscoelastic properties were used to develop a power law model with Boltzmann's convolution integral. The model was capable of predicting a prolonged stress relaxation and recovery curve. For larger deformation, the results were quantified using a nonlinear analysis of viscoelastic response of the spinal cord under the uniaxial experiment.

Animals↗

Biomechanics of spinal cord injury.

This article summarizes the biomechanical relationship of the spinal column to load stresses with respect to column failure, and the resulting associated central nervous system injury. In addition, it presents pertinent animal research, which has focused onto the development standardized animal spinal cord injury model.

Animals↗

Simulation in vitro of pulsatile vascular hemodynamics using a CAD/CAM-designed cam disc and roller follower.

An in vitro perfusion circuit is described that is capable of stimulating pulsatile peripheral vascular hemodynamics. A novel feature of its design is the incorporation of a computer-aided design and manufacture disc cam and roller follower for delivery of pulsatile hemodynamics. To date approximately 75 canine carotids have been perfused for periods of 2-24 h. The delivery of quantifiable hemodynamics in vitro via the rotation of a cam and roller follower has been found to be highly reliable on a cycle-to-cycle basis.

Animals↗

Mechanical and neurological response of cat spinal cord under static loading.

The force/deformation relationship of the exposed spinal cord of cats was studied when the force was gradually applied posteriorly at T10. A linear elastic behavior was identified for deformation less than 0.5 mm, but it was not observed when the static force was no longer supported by the dural sheath. Nonlinear force/deformation, along with a strong hysteresis during a cycle of compression and decompression. The mechanical behavior remained practically the same in a repeated loading if the deformation was less than 2 mm. The motor function of cats did not recover after the cord had been compressed to 4 mm. The associated static force was about 15% of the dynamic force producing the same deformation.

Animals↗

Stress-strain relationship and neurological sequelae of uniaxial elongation of the spinal cord of cats.

An in vivo experimental method was developed to measure the mechanical or rheological properties of the spinal cord of anesthetized cats. This novel approach resulted in measurements of the tensile force in the cord and the modulus of the spinal cord tissue under longitudinal elongation. Both sensory and motor function of the cats recovered within a week after a spinal cord segment had been stretched by a 50% elongation.

Animals↗

Positioning the right atrial catheter: a model for reappraisal.

A flexible Silastic casting of the human right atrium was developed to correspond to some in vivo human right atrium hemodynamic characteristics including chamber pressures, pulsatility, fluid output, and flow velocity. Using an infusion pump, air was introduced (10 ml in 30 s) into the superior vena cava of the model and aspirated via a catheter from different positions within the model atrial chamber. The tests were carried out at atrial inclinations of 60 degrees, 80 degrees, and 90 degrees from the horizontal and compared the aspiration efficiency of a single-orificed 16-gauge catheter to a 16-gauge multiorified (5 aperatures) catheter. Optimal air aspiration occurred with the multiorificed catheter tip positioned within the area 2.0 cm below the junction of the superior vena cava (SVC) and the atrial chamber at an inclination of 80 degrees. As much as 80 per cent of the incoming air could be aspirated under these conditions. At its optimal position the single-orificed catheter gave a maximal yield of 45 to 50 per cent aspiration when the tip was positioned 3.0 cm above the SVC and atrial chamber junction. Aspiration of air from mid right atrium (4.5 cm below the SVC-atrial junction) was poor regardless of the type of catheter used or atrial inclination. These data suggest a need for reappraisal of catheter design and placement.

Cardiac Catheterization↗

Biomechanical and neurological response of the spinal cord of a puppy to uniaxial tension.

An in-vivo experimental method was developed to measure the stress-strain relationship of a spinal cord segment of anesthetized puppies. A pseudo Young's modulus was defined for the linear region followed by a nonlinear rheological behavior of finite strain. Both the sensory response and motor function of the puppies were fully recovered within the 5 days after the spinal cord segment in the first lumbar region was elongated once by 50 percent or less. The usefulness of the in-vivo experiments was further elaborated by demonstrating the large artifacts that could be associated in an in-vitro experiment.

Animals↗

Cardiopulmonary dynamics during arteriovenous perfusion: cardiac output, pulmonary arterial resistance, and right venticular stroke work.

The effects of arteriovenous perfusion on myocardial performance, pulmonary circulatory dynamics, and organ preservation were studied in dogs in order to evaluate the applicability of arteriovenous extracorporeal membrane oxygenation for partial respiratory support. Studies were made on normally oxygenated dogs, on dogs made hypoxic by oxygen deprivation and ventilatory depression, and on dogs with pulmonary injury and moderate pulmonary hypertension induced by injection of oleic acid into the right ventricle. The latter two groups were included to assess the changes that occur in cardiopulmonary dynamics in the presence of hypoxia and pulmonary hypertension. A microchannel membrane oxygenator was employed to provide partial respiratory support to the group of animals with pulmonary injury. The results indicate that no deleterious hemodynamic changes occurred in any of the groups of animals with arteriovenous flow for periods of up to 5 hours at rates corresponding to 20 to 35% of the total cardiac output. Adequate systemic oxygenation was provided by the microchannel oxygenator at these rates of arteriovenous perfusion.

Animals↗

Analysis and comparison of venous air embolism detection methods.

Changes in precordial ultrasonic Doppler patterns in dogs were compared with changes of end-tidal carbon dioxide (EtCO2) and pulmonary arterial pressure (PAP). Possible mechanisms of pulmonary arterial hypertension after air embolism in dogs are discussed. After the injection of air, an immediate change in the Doppler ultrasonic pattern was detected, including a shift of the base line. The duration of change of Doppler patterns varied depending upon the length of time that trapped air remained in the right heart. There was a delay of 15 to 30 seconds before the EtCO2 and PAP responded. In a group of dogs pretreated with 0.3 mg of propranolol per kg, there was a significant decrease in the PAP response due to induced air embolism compared to the control group (P < 0.05). We found that the Doppler ultrasonic device was the most sensitive for detecting venous air embolism at a level as low as 0.05 ml of air per kg compared to 0.25 ml/kg for the PAP and EtCO2 responses.

Animals↗

Arteriovenous ECMO for neonatal respiratory support. A study in perigestational lambs.

A study was undertaken to investigate the applicability of the arteriovenous mode of perfusion for partial support of neonatal respiration. Perigestational lambs, delivered by cesarean section, served as the animal model of respiratory distress. Arteriovenous flow was accomplished between a single umbilical artery and vein. A microchannel membrane oxygenator was used to provide partial respiratory support to the newborn lambs. Total systemic flow, pulmonary blood flow, and pulmonary vascular resistance were assessed at various rates of arteriovenous perfusion and correlated with systemic oxygenation. A reduction in right-to-left shunting of blood and pulmonary vascular resistance occurred as arterial oxygenation rose from conditions of hypoxemia to PaO2 values higher than 50 torr. Myocardial performance was not impaired at rates of arteriovenous perfusion below 30 percent of the total systemic flow, as evidenced by normal electrocardiographic tracings, pulmonary capillary wedge pressures, and central venous pressures. Arteriovenous extracorporeal membrane oxgenation (ECMO) may be particularly suitable for use in infants with hypoxia and high pulmonary vascular resistance.

Animals↗

The standardization of experimental impact injury to the spinal cord.

The biomechanical criteria for standardization of experimental impact injury to the spinal cord are derived. The theory is verified experimentally using cats. The undesirable effect due to heavy impounders is discussed. A falling mass of 20 gm and a small impounder 5 mm in diameter with a mass of 0.1 gm are recommended, leaving the momentum of the falling body to be controlled for different degrees of trauma.

Animals↗