Imaging of hypoxia in human tumors with [F-18]fluoromisonidazole.

Fluoromisonidazole (FMISO) has been shown to bind selectively to hypoxic cells in vitro and in vivo at radiobiologically significant oxygen levels. When labeled with the positron emitter fluorine-18 (F-18), its uptake in tissue can be detected quantitatively with high precision by positron emission transaxial tomography (PETT). This paper presents the first experiences with PETT imaging of [F-18]FMISO uptake in human malignancies, and describes the development of this technique as a tool for the non-invasive assessment of tumor hypoxia. Eight patients with selected cancers were imaged prior to primary radiotherapy, and 3 returned for follow-up scans, for a total of 11 imaging studies. Six of eight pre-radiotherapy studies revealed retention of [F-18]FMISO in tumors that significantly exceeded plasma concentrations by 2 hr after drug injection; all five patients with head and neck primaries had such "positive" scans. An analytic method for the interpretation of [F-18] FMISO PETT images is presented, defining hypoxic elements within a tumor volume as regions with a threshold regional tumor:plasma [F-18]FMISO ratio of greater than or equal to 1.4 by 2 or more hours after injection. Toward the end of a course of fractionated radiotherapy, three repeat studies in patients with initially positive scans showed no tumor accumulation of drug above the threshold ratio of 1.4, suggesting reoxygenation had occurred. Pharmacokinetic and dosimetry data support continued use of [F-18]FMISO as a safe hypoxia probe. Two imaging protocols have been developed for human studies; a long protocol allows for more complete biodistribution and dosimetry information, and a shorter protocol facilitates increased patient accrual by applying a simple, clinically expedient imaging procedure. When correlated with tumor outcome, [F-18]FMISO PETT imaging may be developed as a predictor of tumor response to conventional radiotherapy. The implications of this technique in addressing persistent questions of tumor hypoxia in human oncology is discussed.

Cell Hypoxia

Noninvasive detection of hypoxic myocardium using fluorine-18-fluoromisonidazole and positron emission tomography.

Fluoromisonidazole (FMISO) is metabolically trapped in viable cells as a function of reduced cellular pO2. Therefore [18F]-FMISO is potentially useful for evaluating patients with hypoxic but viable myocardium. The goal of this study was to investigate [18F]FMISO uptake in ischemic myocardium non-invasively using positron emission tomography (PET). Studies were performed in 10 open-chest dogs subjected to either complete (Group 1, n = 5) or partial (Group 2, n = 5) occlusion of the left anterior descending coronary artery. The tracer was administered by intravenous bolus following the onset of ischemia and serial PET images were acquired for the next 4 hr. In Group 1, viability was assessed using histochemical staining (nitroblue tetrazolium, NBT) and 99mTc-pyrophosphate (Tc-PYP). In Group 2, viability was assessed using measurements of regional wall motion, histochemical staining and histology (two animals). In each study, PET images obtained at times between 2 and 4 hr postinjection showed specific enhancement of tracer activity in the distal anterior wall and apex of the left ventricle. At 4 hr, the tissue-to-blood pool count ratio was significantly higher in ischemic regions; 1.8 +/- 0.4 for Group 1 and 1.6 +/- 0.2 for Group 2 versus 1.0 +/- 0.1 in nonischemic regions. Postmortem tissue sampling of Group 1 hearts showed significant FMISO retention in samples without evidence for infarction, either by NBT or Tc-PYP deposition, as well as in more severely ischemic regions. In Group 2 animals, FMISO was retained in myocardial regions with reduced blood flow (microspheres), which exhibited improved contraction following reperfusion. We conclude that PET imaging of [18F]FMISO is a promising technique for the noninvasive identification of viable hypoxic myocardium.

Animals

A method for imaging therapeutic doses of iodine-131 with a clinical gamma camera.

Imaging therapeutic doses of 131I-labeled monoclonal antibody would provide valuable biodistribution data for dosimetry, but gamma cameras are unable to accurately handle the corresponding high counting rate. To image patients undergoing radioimmunotherapy, we attached 1.6- to 6.4-mm-thick Pb sheets to the front face of a high-energy parallel-hole collimator. With this method, we were able to acquire planar images of up to 700 mCi of radiolabeled antibody 1 hr after infusion. Monte Carlo simulations indicated that less than 7% of the events counted in the photopeak window were due to 364-keV photons that scattered in the Pb attenuator. Measurements indicated that the Pb sheets degraded system resolution by no more than 13%. A quantitative comparison of trace and therapy biodistribution data from planar images of the same patient was made using corrections for Pb sheet attenuation and camera deadtime.

Gamma Cameras

Performance standards in positron emission tomography.

A standard set of performance measurements is proposed for use with positron emission tomographs. This set of measurements has been developed jointly by the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. The measurements include tests of spatial resolution, scatter fraction, sensitivity, count rate losses and randoms, uniformity, scatter correction, attenuation correction, and count rate linearity correction.

Humans

Evaluation of a clinical scintillation camera with pulse tail extrapolation electronics.

The performance of a new scintillation camera, designed for high event rate capability, was evaluated. The system consisted of a 400 mm field-of-view Nal(T1) camera with 61 photomultiplier tubes and modified General Electric Starport electronics. A significant feature of the system was circuitry for performing pulse tail extrapolation and separation of individual pulses involved in pulse pile-up events. System deadtime, flood field uniformity, energy resolution, linearity, spatial resolution, and bar phantom image quality were evaluated for count rates up to 200 kcps in a 20% photopeak window. Our results indicate that this camera design does not compromise image quality at normal clinical count rates and at higher event rates can provide better image quality and increased sensitivity over many Anger cameras currently employed in nuclear medicine.

Evaluation Studies as Topic

Blood flow changes following 137Cs irradiation in a rat glioma model.

Blood flow changes in response to 20 Gy 137Cs whole brain irradiation were measured with quantitative autoradiography of [14C]iodoantipyrine (IAP) in intracerebral grafts of the 36B-10 rat glioma, the brain around tumor (BAT), the contralateral corpus callosum, and the contralateral cerebral cortex. Irradiations were delivered on Day 14 post-transplantation, and measurements of flow (F) were performed with IAP on Day 15 or Day 16. Mean values of F were determined in individual tumors and in treatment groups. In 15- and 16-day-old unirradiated control tumors, the group mean F was 0.31 ml.g-1.min-1. In both 15- and 16-day-old tumor groups irradiated on Day 14 (Day 1 and 2 postirradiation tumors) the mean F for each day's group was 0.52 ml.g-1.min-1, 68% higher than the control (P less than 0.01). Flow in the BAT and the contralateral corpus callosum similarly was increased at these times (P less than 0.01). Flow in the contralateral cerebral cortex was 1.1, 1.5, and 1.3 ml.g-1.min-1 in the control, 1 day postirradiated, and 2 day postirradiated groups, respectively, but these increases were not significantly different from the control. These data indicate that flow increases in the intracerebral gliomas as well as in normal brain regions during the 2 days following 20 Gy irradiation. Changes such as these following radiotherapy may have important effects on the bioavailability of chemotherapeutic drugs.

Animals

Considerations in the purchase of a nuclear medicine computer system.

Selection of a nuclear medicine computer system is a process that should be approached with care and forethought. The general scheme should be to define your needs and constraints, determine what is available, investigate the leading candidates, make a site visit, and, finally, submit an order. Through a series of discussions between members of the Computer Council of the Society of Nuclear Medicine and representatives from the manufacturers of computer systems, a set of important considerations emerged, which are reported in this paper. This paper is not intended to be a step-by-step guideline to the purchase of a computer system. Rather, it is a set of concepts and considerations with which the prospective purchaser should be familiar before undertaking such a purchase.

Computer Systems

Regional blood-to-tissue transport in an irradiated rat glioma model.

To assess vascular permeability in intracerebral grafts of the 36B-10, F-344 rat glioma following 20 Gy 137Cs whole brain irradiation, the blood-to-tissue transport constant, K, of [14C]-alpha-aminoisobutyric acid (AIB) was measured with quantitative autoradiography. Mean, 90th percentile, and 95th percentile values of K were determined in individual tumors and in treatment groups. In 15-day-old unirradiated control tumors, mean, 90th percentile, and 95th percentile values of K were, respectively, 11.3, 18.4, and 20.8 ml kg-1 min-1. In 15-day-old tumors irradiated on Day 14 (Day 1 postirradiation tumors) the K values were 5.9, 9.4, and 10.4, all of which were significantly less than the respective control values (P less than 0.01). In 16-day-old tumors irradiated on Day 14 (Day 2 postirradiation tumors), the K values were 10.8, 15.0, and 16.0, respectively, none of which was significantly different from control tumors. Mean K values for Day 2 vs Day 1 postirradiation tumors (10.8 vs 5.9) yielded P less than 0.05, but the 90th percentile and 95th percentile values for Day 2 vs Day 1 yielded 0.05 less than P less than 0.10. Separate experiments measured AIB and 86RbCl uptake in 36B-10 cells in vitro 1 and 2 days following 20 Gy irradiation to assess whether this radiation dose reduced the capacity of tumor cells to trap AIB or Rb+. Irradiation did not reduce the accumulation of either tracer, but rather was associated with an increased accumulation of AIB. Therefore, the AIB transport data suggest that vascular permeability and/or surface area decreases significantly in the day following 20 Gy irradiation and that this decrease reverses by the second day following irradiation.

Aminoisobutyric Acids

Quantitative autoradiographic evidence for insulin receptors in the choroid plexus of the rat brain.

Techniques of in vitro receptor autoradiography were used to visualize binding of 125I-insulin on slices of frozen rat brain. Slide-mounted sections of frozen rat brain were incubated in 0.05 nM porcine 125I-monoiodoinsulin, alone or mixed with 1 microM unlabeled porcine insulin, ribonuclease, or glucagon, for 2 h at 22 degrees C. The labeled brain slices were apposed to LKB Ultrofilm to generate autoradiograms. The method permitted equal access of labeled insulin to both sides of the blood-brain barrier and localization of insulin binding sites in small anatomic regions. Quantitative estimates of specific iodoinsulin binding were made by computer digital image densitometry of the autoradiographic film images. High concentrations of specific binding sites for iodoinsulin were present in the choroid plexus of the lateral (26.9 +/- 2.0 X 10(-3) fmol/mm2), fourth (18.3 +/- 3.0 X 10(-3) fmol/mm2), and third (13.2 +/- 1.5 X 10(-3) fmol/mm2) ventricles (insulin binding is expressed per unit area of autoradiographic image). Binding to the third ventricular choroid plexus was similar to the concentrations observed for liver slices and the external plexiform layer of the olfactory bulb. Specific binding of iodoinsulin in the cingulate cortex and other surrounding regions was less than in choroid plexus. Ribonuclease or glucagon had no measurable effect on binding when mixed with labeled insulin. The results support the hypothesis that the choroid plexus has a high density of receptors for insulin, and suggests that the choroid plexus may be a target of CSF insulin action and/or a site of insulin transport into the CSF.

Animals

Quantitative autoradiography using a personal computer.

A video digitizing system based on an Apple II personal computer has been developed for use in quantitative autoradiography. The selection process of an acceptable video camera, an illumination system, and the functions provided in the software are discussed. This system is in routine use and has been duplicated by several other laboratories.

Autoradiography

Total body calcium by neutron activation analysis in normals and osteoporotic populations: a discriminator of significant bone mass loss.

This paper reports total body calcium by neutron activation (TBC) measurements in 94 normal individuals and 86 osteoporotic patients. The ability of TBC to discriminate normal from osteoporotic females was evaluated with decision analysis. Bone mineral content (BMC) by single-photon absorptiometry was also measured. TBC was higher in males (range 826 to 1363 gm vs 537 to 1054 in females) and correlated with height in all normals (r = 0.55 in males, 0.58 in females; p less than 0.001). In females over age 55 there was a negative correlation with age (r = -0.51, p less than 0.01). Thus, for normals an algorithm was derived to allow comparison between measured TBC and that predicted by sex, age, and height (TBCp). In the 28 normal females over age 55, the TBC was 764 +/- 115 gm vs. 616 +/- 90 in the osteoporotics (p less than 0.001). In 63 of the osteoporotic females an estimated height, from tibial length, was used to predict TBC. In normals the TBC/TBCp ratio was 1.00 +/- 0.12, whereas in osteoporotic females it was 0.80 +/- 0.12 (p less than 0.001). A receiver operating characteristic curve showed better discrimination of osteoporosis with TBC/TBCp than with wrist BMC. By using Bayes' theorem, with a 25% prevalence of osteoporosis (estimate for postmenopausal women), the posttest probability of disease was 90% when the TBC/TBCp ratio was less than 0.84. We conclude that a low TBC/TBCp ratio is very helpful in determining osteoporosis.

Activation Analysis

A low-contrast phantom for daily quality control.

A simple phantom is proposed to provide a low-contrast test object for daily quality assurance. The phantom consists of four quarters and five dimes taped to a Plexiglas plate. For daily quality control, the phantom is used with 5 cm of Plexiglas as scattering material and a flood source. Examples of images are presented for several gamma cameras, illustrating some of the information that can be obtained. In particular, we present examples of cameras providing improper imaging performance with the coin phantom but with "normal" floods and bar-phantom images. The major conclusion is that daily quality-control images should include significant of scattering material and low-contrast objects.

Models, Structural

A comparison of count rate parameters in gamma cameras.

Pulse pile-up is a fundamental problem that limits the ability of a gamma camera to produce high quality images at high count rates. Pulse pile-up results in loss of events and spatial distortions in the image. The question asked in this study is how well do some of the test procedures for measuring count rate performance in gamma cameras compare. In four gamma cameras we compared measurements of spectral fraction, count-rate curve, pulse-pair resolution, deadtime, maximum count rate, full width at half maximum of the line spread function, and misplaced event count rate. The results indicated that no one technique provides a complete description of the count-rate effects in gamma cameras. The misplaced-event measurements provided the most information.

Evaluation Studies as Topic

A system for measuring total body calcium in man using the 40Ca(n, alpha)37 Ar reaction.

A technique to measure total body calcium using the 40Ca(n, alpha)37 Ar reaction has been developed. The technique is based on collecting 37Ar exhaled in the breath following a 10 mrad uniform total body irradiation by 14 MeV neutrons. The 37Ar in the exhaled breath is extracted by selective absorption and its radioactivity is measured inside a low-background proportional detector. The facilities developed include an activation facility providing a +/-2.7% activation uniformity, a closed circuit rebreathing and gas collection system, and a gas purification and counting system. The technique provides a precision of +/-2.4% as determined by repetitive measurements of human volunteers and has an accuracy for determination of total body calcium in grams of +/-5%.

Argon

A field procedure for the quantitative assessment of nuclear imaging cameras.

Techniques developed for the quantitative assessment of gamma cameras are described. The performance parameters discussed include energy resolution, intransic line spread function, uniformity, and extrinsic line spread function. In addition to describing the equipment used and indicating methods used in analyzing data, some of the potential problems in interfacing multichannel analyzers to gamma cameras are discussed.

Electronics, Medical