PubMed Health⌕ Search

Biomedical subjects

T Kööbi

Publications and source records attributed to T Kööbi.

At least 19 recordsLinked to original sources

Ten-year prognosis of Puumala hantavirus-induced acute interstitial nephritis.

Nephropathia epidemica (NE) is a hemorrhagic fever with renal syndrome caused by Puumala hantavirus. Its long-term prognosis is considered favorable. There are, however, some reports about subsequent hypertension, glomerular hyperfiltration, and proteinuria after previous hantavirus infection. Therefore, we studied 36 patients 5 and 10 years after acute NE, with 29 seronegative controls. Office blood pressure, ambulatory 24-h blood pressure (ABP), glomerular filtration rate (GFR), and proteinuria were examined. Hypertensive subjects were defined as those patients having increased ambulatory or office blood pressure, or receiving antihypertensive therapy. Office blood pressure was used to define hypertension only if ABP was not determined. At 5 years, the prevalence of hypertension was higher among NE patients than in controls (50 vs 21%, P=0.020). At 10 years, the difference between the groups was no more significant (39 vs 17%, P=0.098). Five years after NE, patients showed higher GFR (121+/-19 vs 109+/-16 ml/min/1.73 m(2), P=0.012) and urinary protein excretion (0.19 g/day, range 0.12-0.38 vs 0.14 g/day, range 0.09-0.24, P=<0.001) than controls. At 10 years, there were no more differences in GFR or protein excretion between the groups (GFR: 113+/-20 vs 108+/-17 ml/min/1.73 m(2), P=0.370; proteinuria: 0.14 g/day, range 0.07-0.24 vs 0.13 g/day, range 0.06-0.31, P=0.610). In conclusion, the 10-year prognosis of NE is favorable, as glomerular hyperfiltration and slight proteinuria detected at 5 years disappeared during the longer follow-up. However, the possibility exists that NE may predispose some patients to the development of hypertension.

Acute Disease↗

Maternal haemodynamics in pre-eclampsia compared with normal pregnancy during caesarean delivery.

OBJECTIVE: To determine how pre-eclampsia modifies maternal haemodynamics during caesarean delivery. DESIGN: Prospective study. SETTING: Tampere University Hospital, Finland. POPULATION: Ten pre-eclamptic parturients and ten healthy parturients with uncomplicated pregnancies scheduled for elective caesarean section under spinal anaesthesia. METHODS: Haemodynamic parameters were assessed by whole-body impedance cardiography noninvasively. MAIN OUTCOME MEASURES: Stroke index (SI), heart rate (HR), cardiac index (CI), systemic vascular resistance index (SVRI) and mean arterial pressure (MAP) were recorded before operation, continuously during caesarean section, during the period of dissipation of anaesthesia and on the second to fifth postpartum day. RESULTS: Baseline haemodynamics in women with pre-eclampsia differed significantly from healthy women in higher SVRI and MAP and lower SI and CI. In women with pre-eclampsia, preload infusion increased both SI and HR, causing a significant rise in CI, while in healthy parturients, only HR rose. In both the groups, spinal blockade reduced SVRI but CI remained stable. At the moment of delivery, CI increased in both groups. In uncomplicated pregnancies, both SI and HR increased, but in women with pre-eclampsia, SI was not altered and the rise in CI was due to an increase in HR only. After the reversal of anaesthesia, haemodynamics in the control group returned to baseline values, whereas in women with pre-eclampsia, SI and CI fell to levels that were significantly lower than the levels observed before surgery. CONCLUSIONS: In women with pre-eclampsia, inability to increase SI at the moment of delivery may suggest dysfunction of the left ventricle to adapt to volume load caused by delivery and prompts concern for the increased risk of pulmonary oedema.

Adult↗

Effects of hypertonic saline (7.5%) on extracellular fluid volumes in healthy volunteers.

This study evaluated the effects of 7.5% saline on plasma and other extracellular fluid volumes. After baseline measurements, eight healthy postmenopausal female volunteers received 4 ml.kg-1 of hypertonic saline over 30 min. After the fluid infusion, the volunteers were studied for 60 min. Plasma volume was measured using a dilution of 125-iodine-labelled human albumin. Extracellular water and cardiac output were measured by whole body impedence cardiography. The infused volume was 4 ml.kg-1 (average 260 ml). Plasma volume increased rapidly during the infusion (mean +/- standard deviation, 442 +/- 167 ml). At the end of the 1-h follow-up period, plasma volume had increased by on average 465 ml (SD 83). The increase of extracellular water at the end of infusion and at the end of study was 650 ml (SD 93) and 637 ml (SD 192), respectively. The highest serum sodium recorded in the volunteers was 158 mmol.l-1. The effect of 7.5% saline on plasma volume was rapid and lasted for at least 1 h. Plasma volume remained elevated by more than the infused volume at the end of the study. The increase in plasma and extracellular fluid volumes was partly achieved by mobilizing intracellular water to extracellular compartment.

Aged↗

Isolated ultrafiltration affects dynamic vectorcardiographic ischemia monitoring parameters.

AIMS: The present study was undertaken to assess the role of isolated ultrafiltration (UF phase) and hemodialysis with minimal ultrafiltration (HD phase) in changes in parameters reflecting myocardial ischemia: QRS vector difference (QRS-VD), ST change vector magnitude (STC-VM) and ST vector magnitude (ST-VM6) registered by MIDA (myocardial infarction dynamic analysis). PATIENTS AND METHODS: Twelve patients on maintenance hemodialysis were first ultrafiltrated for 2.5 h without dialysis (UF) followed by a 2.5-hour session of hemodialysis with minimal ultrafiltration (HD). Computerized vectorcardiography (VCG) was used for on-line dynamic analysis of ST segment and QRS complex changes. Blood volume (BV) changes were monitored non-invasively and continuously with the CRIT-LINE instrument. Whole-body bioelectric impedance analysis (BIA) was used for extracellular water (ECW) estimation. RESULTS: During the UF phase QRS-VD and STC-VM showed a statistically significant increasing linear trend (time effect for both QRS-VD and STC-VM p < 0.0001, while no changes were noted in ST-VM6; time effect p = 0.986). During the HD phase none of these parameters changed (time effect for QRS-VD p = 0.855, for STC-VM p = 0.275 and for ST-VM6 p = 0.976). During the UF, phase changes in QRS-VD were in close relation to those in ECW. CONCLUSION: Isolated ultrafiltration leads to an increase in the VCG ischemia monitoring parameters QRS-VD and STC-VM. The increase of QRS-VD is related to changes in ECW. Hemodialysis with minimal ultrafiltration has no effect on VCG ischemia monitoring parameters.

Adult↗

Effects of hypertonic 75 mg/ml (7.5%) saline on extracellular water volume when used for preloading before spinal anaesthesia.

BACKGROUND: Prevention of hypotension during spinal anaesthesia is commonly achieved using fluid preloading. This may result in a substantial amount of excess free water retained in the body after spinal anaesthesia. We aimed to evaluate the effects of 7.5% hypertonic saline on extracellular water volume and haemodynamics when used for fluid preloading before spinal anaesthesia. METHODS: This randomised double-blind study evaluated the effects of 75 mg/ml (7.5%) hypertonic saline (HS) on extracellular water volume and haematocrit in patients undergoing arthroscopy or other lower limb surgery under spinal anaesthesia. Amounts of 1.6 ml/kg of HS (20 patients) or 13 ml/kg of 9 mg/ml normal saline (20 patients) were administered for preloading before spinal anaesthesia with a 10 mg dose of 0.5% hyperbaric bupivacaine. Etilefrine was administered in order to maintain mean arterial pressure (MAP) at >or=80% of its baseline value. Whole-body impedance cardiography-derived cardiac index (CI) and extracellular water (ECW) were measured. RESULTS: There were no significant differences in demographic data or in the number of blocked segments. ECW remained similar in both groups despite the much smaller amount of infused free water in the HS group. There were no significant differences between the groups in CI values during the study. The amount of etilefrine administered was similar in the treatment groups. Dilution of haematocrit was also similar in both groups. CONCLUSION: Hypertonic 75 mg/ml (7.5%) saline is an alternative for preloading before spinal anaesthesia in situations where excess free water administration is not desired. It is effective in small doses of 1.6 ml/kg, which increase the extracellular water, plasma volume and cardiac output, and thus maintain haemodynamic stability during spinal anaesthesia.

Adult↗

Effects of hypertonic saline (7.5%) on extracellular fluid volumes compared with normal saline (0.9%) and 6% hydroxyethyl starch after aortocoronary bypass graft surgery.

OBJECTIVE: To compare the effects of hypertonic (7.5%) saline (HS), normal (0.9%) saline (NS), and 6% hydroxyethyl starch (HES) on extracellular fluid volumes in the early postoperative period after cardiopulmonary bypass. DESIGN: A prospective, randomized, double-blind study. SETTING: University teaching hospital. PARTICIPANTS: Forty-eight patients scheduled for elective coronary artery bypass graft surgery. INTERVENTIONS: Patients were randomly allocated to receive 4 mL/kg of HS, NS, or HES during 30 minutes when volume loading was needed during the postoperative rewarming period in the intensive care unit. Plasma volume was measured using a dilution of iodine-125-labeled human serum albumin. Extracellular water and cardiac output were measured by whole-body impedance cardiography. MEASUREMENTS AND MAIN RESULTS: Plasma volume had increased by 19 +/- 7% in the HS group and by 10 +/- 3% in the NS group (p = 0.001) at the end of the study fluid infusion. After 1-hour follow-up time, the plasma volume increase was greatest (23 +/- 8%) in the group receiving HES (p < 0.001). The increase of extracellular water was greater than the infused volume in the HS and HES groups at the end of the infusion. One-hour diuresis after the study infusion was greater in the HS group (536 +/- 280 mL) than in the NS (267 +/- 154 mL, p = 0.006) and HES groups (311 +/- 238 mL, p = 0.025). CONCLUSION: The effect of HS on plasma volume was short-lasting, but it stimulated excretion of excess body fluid accumulated during cardiopulmonary bypass and cardiac surgery. HS may be used in situations in which excess free water administration is to be avoided but the intravascular volume needs correction.

Aged↗

TERVA: system for long-term monitoring of wellness at home.

Long-term monitoring of physiological and psychosocial variables in out-hospital conditions would be beneficial for investigating changes in wellness status of an individual or to understand interaction between physiological and behavioral processes. We aimed to design a personal wellness monitoring system (TERVA), which would allow monitoring of wellness-related variables at home for several weeks or even months. The designed TERVA system runs on a laptop computer and interfaces with different measurement devices through a serial interface. Measured variables include beat-to-beat heart rate, motor activity, blood pressure, weight, body temperature, respiration, ballistocardiography, movements, and sleep stages. In addition, self-assessments of daily well-being and activities are stored by keeping a behavioral diary. To test the system, one healthy man used the system for 10 weeks. The system was successfully applied in out-hospital conditions. The success rate of the measurements was 70-91%, depending on the variable under consideration. The pilot study indicated that the recorded data accurately reflected the health status of the subject. The TERVA system provides a method to record and investigate wellness-related data over several weeks, or even months, outside the hospital among subjects capable of using a personal computer. Several applications of the system are discussed.

Diagnosis, Computer-Assisted↗

Segmental composition of whole-body impedance cardiogram estimated by computer simulations and clinical experiments.

Whole-body impedance cardiography (ICGWB) has been proposed as a feasible means of measuring cardiac output (CO). However, the source distribution of heart-related impedance variations in the whole body is not known. To establish how much of a signal originates in each segment of the body and what the contribution of each is to stroke volume (SV) in ICGWB, impedance in the extremities and trunk were investigated in 15 healthy volunteers. In addition, the theoretical measurement properties of ICGWB were studied using a computer model of the whole-body anatomy as a volume conductor. The model confirmed the expected result that most of the basal impedance originates from the extremities. Clinical experiments revealed that the heart-related amplitude variations in the ICGWB signal originate more evenly from various body segments, the trunk slightly more than the arms or legs. The heart-related ICGWB signal represents a weighted sum of segmental pulsatile events in the body yielding physiologically meaningful data on almost the whole circulatory system.

Adolescent↗

Comparison of bioimpedance and radioisotope methods in the estimation of extracellular water volume before and after coronary artery bypass grafting operation.

To estimate extracellular water volume (ECW) changes in connection with coronary artery bypass grafting operation, simultaneous ECW estimations by 51Cr-EDTA dilution and whole-body bioimpedance techniques were performed in 15 patients. The assessments of ECW were compared with patients' weighing results. Whole-body bioimpedance-derived ECW correlated significantly with 51Cr-EDTA dilution-based ECW in the pre-operative period (r=0.74; P<0.005); the bias was 0.2 +/- 1.1 l (+/-SD). In the post-operative period, the agreement between these methods was poor, the bias being 0.5 +/- 2.5 l, and no significant correlation between the methods was found (r=0.38; P>0.05). Whole-body bioimpedance-derived ECW changes correlated significantly with weight changes of the patient induced by the operation (r=0.52; P<0.05). 51Cr-EDTA dilution-based ECW changes correlated neither with weight changes (r=0.33; P>0.05) nor with bioimpedance-derived ECW changes (r=0.03; P>0.05). Alterations in radioisotope tracer distribution and loss of it due to blood leakage in the post-operative period were presumed to explain the discrepancy between dilution technique and weighing results. The results suggest that bioimpedance is a useful non-invasive method for assessment of extracellular volume changes induced by coronary artery bypass grafting operations. 51Cr-EDTA dilution-based ECW determination is not suitable in related conditions.

Aged↗

Can stroke volume and cardiac output be determined reliably in a tilt-table test using the pulse contour method?

The applicability of the finger pressure-derived pulse contour (PC) technique was evaluated in the measurement of stroke volume (SV), cardiac output (CO) and their changes in different phases of the tilt-table test. The reference method was whole-body impedance cardiography (ICG). A total number of 40 physically active patients, aged 41 +/- 19 years, were randomly chosen from a pool of 230. Specifically speaking, 20 of the patients experienced (pre)syncope (tilt+ patients) during the head-up tilt (HUT), and 20 did not (tilt-). A total number of three measurement periods, 30-60 s each, were analysed: supine position, 5 min after the commencement of HUT, and 1 min before set down. SV and CO values measured by PC underestimated significantly those measured by ICG (biases +/- SD 19 +/- 14 ml and 1.55 +/- 1.14 l min-1, respectively) in agreement with earlier reports. The bias between the methods was almost the same in the different phases of the test. However, the SD of the bias was bigger for tilt+ (P < 0.05). When the bias between the methods was eliminated by scaling the first measurement to 100%, the agreement between the methods in the second and third measurements was clearly better than without scaling. Both methods showed a physiological drop in SV after the commencement of HUT. These results indicate that PC suffices in tracking the changes in CO and SV, but for absolute values it is not reliable.

Adult↗

The comparison of hypertonic saline (7.5%) and normal saline (0.9%) for initial fluid administration before spinal anesthesia.

Hypertonic saline can be used for initial fluid administration before spinal anesthesia. It is effective in small-volume fluid resuscitation. This randomized double-blinded study compared the effects of 7.5% hypertonic saline (HS) and 0.9% normal saline (NS) in doses containing 2 mmol/kg of sodium in 40 ASA physical status I-II patients undergoing arthroscopy or other lower limb surgery under spinal anesthesia. We infused 1.6 mL/kg of HS or 13 mL/kg of NS for initial fluid administration before spinal anesthesia induced with a 10-mg dose of 0.5% hyperbaric bupivacaine. Etilefrine was administered to maintain mean arterial pressure at > or =80% of its control value. Systolic and diastolic blood pressure, heart rate, and cardiac index did not differ between the groups, and the amount of etilefrine administered was similar in the treatment groups. In all our patients, the plasma sodium concentrations were within the normal range after surgery and serum osmolality was within the normal range after spinal anesthesia. The time and the volume of the first micturition were similar in both groups, despite the much smaller amount of infused free water in the HS group. We conclude that 7.5% HS was as good as NS for the initial fluid administration before spinal anesthesia when the amount of sodium was kept unchanged.

Adolescent↗

Hemodialysis causes changes in dynamic vectorcardiographic ischemia monitoring parameters.

AIMS: The aim of this study was to establish whether changes in parameters reflecting myocardial ischemia QRS vector difference (QRS-VD), ST change vector magnitude (STC-VM) and ST vector magnitude (ST-VM6) during hemodialysis (HD) registered by MIDA (myocardial infarction dynamic analysis) are related to changes in blood volume (BV), extracellular water (ECW) and blood biochemistry. PATIENTS AND METHODS: Fifteen hemodialysis (HD) patients were studied. Computerized vectorcardiography was used for on-line dynamic analysis of ST segment and QRS complex changes. BV changes were monitored non-invasively and continuously with the CRIT-LINE instrument. Bioelectric impedance analysis (BIA) was used for ECW estimation. Blood samples were taken before and after hemodialysis for hemoglobin (B-Hb), hematocrit (B-Hcr), sodium (P-Na), chloride (P-Cl), magnesium (P-Mg), potassium (P-K), ionized calcium (P-iCa), phosphate (P-Pi) and astrup measurement. RESULTS: During dialysis treatment QRS-VD, ST-VM6 and STC-VM did not change in parallel. According to the linear mixed model, no statistically significant changes were noted in ST-VM6 during dialysis (time effect p = 0.5635). On the other hand, QRS-VD and STC-VM showed a statistically significant linear trend (time effect for QRS-VD p = 0.0001 and for STC-VM p = 0.0004). Changes in both ECW and BV affected the change in QRS-VD and in STC-VM. CONCLUSION: During HD treatment changes in the vectorcardiographic ischemia monitoring parameters QRS-VD and STC-VM are mostly related to ECW and BV changes and may give a false positive impression of myocardial ischemia. The ST-VM6 trend is less markedly influenced by volume changes.

Adult↗

Lead field theoretical approach in bioimpedance measurements: towards more controlled measurement sensitivity.

This study was conducted to demonstrate the potentiality of lead field theoretical approach in analyzing bioimpedance (BI) measurements. Anatomically accurate computer models and the lead field theory were used to develop BI measurement configurations capable of detecting more localized BI changes in the human body. The methods were applied to assess the measurement properties of conventional impedance cardiography (ICG) and such BI measurement configurations as can be derived using (i) the 12-lead electrocardiography (ECG) and (ii) the international 10-20 electroencephalography (EEG) electrode systems. Information as to how various electrode configurations are sensitive to detecting conductivity changes in different tissues and organs was thus obtained. Theoretical results with the 12-lead system suggested that, compared to conventional ICGs, significantly more selective ICG configurations can be derived for cardiovascular structures. In addition to theoretical investigations, clinical test measurements were made with the 12-lead system to establish whether characteristic waveforms are available. Sensitivity distributions obtained with the 10-20 electrode system give promise of the possibility of monitoring noninvasively cerebrospinal fluid (CSF) impedance changes related to impending epileptic seizures.

Cardiography, Impedance↗

Multiple lead recordings improve accuracy of bio-impedance plethysmographic technique.

We have developed the theory and instrumentation of multiple multi-electrode bio-impedance (BI) measurements based on lead field theoretical approach. To derive reliable information based on BI data, a quantity of measurements should be taken with electrode configurations possessing regional measurement sensitivity. An apparatus has been developed with an eye to the requirements imposed by the theoretical aspects of achieving multiple multi-electrode BI measurements. It has features compensating electrode-contact related errors and errors due to imbalance between the conductive pathways when multiple electrodes are utilised for BI measurement. The proposed design allows simultaneous multi-electrode BI and bioelectric recording with the same electrode system. Initial operation experiences in clinical environment indicate that the device functions as intended, and allows user-friendly utilisation of multiple BI measurements. Contributions presented to BI methodology and instrumentation improve the reliability of BI measurements.

Electrodes↗

Non-invasive cardiac output determination: state of the art.

This review deals with recent developments in non-invasive cardiac output measurement. In the past few years significant progress has been made with semi-invasive transoesophageal echocardiography; the method now provides advanced facilities to measure cardiac output and other important characteristics of cardiac function. The method is, however, operator-dependent and the equipment used is expensive, which means that large-scale use on intensive care patients is not feasible. Whole-body impedance cardiography has recently shown good accuracy and flexibility in use, and seems to be the most promising method for the non-invasive measurement of cardiac output.

Journal Article↗

Cardiac output can be reliably measured noninvasively after coronary artery bypass grafting operation.

OBJECTIVE: To evaluate the reliability of whole-body impedance cardiography in the measurement of cardiac output after coronary artery bypass grafting operation in comparison with the thermodilution method. DESIGN: Prospective, consecutive sampling. PATIENTS: A total of 82 patients undergoing coronary artery bypass surgery were investigated. In a group of 41 patients who were intubated, cardiac output measurements were taken simultaneously with whole-body impedance cardiography and the thermodilution method within the first 3 hrs after the operation (early intensive care unit [ICU] period). In another group of 41 patients, the measurements were taken before the operation and in the second 12 hrs after cardiac surgery (late ICU period). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The agreement between the thermodilution and whole-body impedance cardiography cardiac output measurements was good before the operation, bias 0.04 +/- 1.64 L/min (n = 41), and in the late ICU period, bias 0.00 +/- 1.84 L/min (+/-2 SD) (n = 41). The results were within 20% in 81%-85% of the cases. The agreement was satisfactory in the early ICU period, bias 0.38 +/- 2.74 L/min (n = 41). It was presumed that thermal instability of the patients was one possible source of measurement errors in the thermodilution method, causing reduced agreement between the methods in this period. The repeatability values (rv = 2.83 x SDs) for whole-body impedance cardiography were 0.44 L/min before the operation, 0.30 L/min in the early ICU period, and 0.65 L/min in the late ICU period, being significantly better than for the thermodilution method (0.79, 0.51, and 1.11 L/min, respectively) in all phases of the investigation (p < .001). The agreement between the thermodilution method and whole-body impedance cardiography is similar to reported comparisons between invasive methods in analogous settings. CONCLUSIONS: Whole-body impedance cardiography reliably measures cardiac output in patients after coronary artery bypass grafting operation. The excellent repeatability of whole-body impedance cardiography enhances the value of the method in continuous monitoring of patients after the operation.

Aged↗

Visual versus computerized analysis of upsloping ST segment depression in the exercise electrocardiogram.

A slowly upsloping ST segment depression is an abnormal, and a rapidly upsloping ST segment depression is a normal exercise ECG response. We investigated the agreement of expert physicians on the visual classification of the ST segment depression, and compared the (majority) vote with the computer-generated ST slope. A total of 206 exercise ECG leads with an amplitude of the ST segment depression > or = 0.15 mV and a ST segment slope > or = 0.5 mVs(-1) were evaluated. All three interpreters agreed in 68 cases, two agreed in 123 cases, and all disagreed in 15 cases. Intraobserver agreement was 61%. The ST segment slope was significantly (p < 0.001) greater in leads generally interpreted as rapidly upsloping (n = 38; 2.1 +/- 0.8 mVs(-1)), than in those interpreted as slowly upsloping (n 121; 1.3 +/- 0.6 mVs(-1)) or horizontal (n = 32; 1.1 +/- 0.4 mVs(-1)), although there was some overlap. Thus, standardization of the computer-assisted exercise ECG interpretation should be continued.

Adult↗