PubMed Health⌕ Search

Biomedical subjects

T Kissel

Publications and source records attributed to T Kissel.

At least 19 recordsLinked to original sources

Branched polyesters based on poly[vinyl-3-(dialkylamino)alkylcarbamate-co-vinyl acetate-co-vinyl alcohol]-graft-poly(d,l-lactide-co-glycolide): effects of polymer structure on cytotoxicity.

Branched polyesters of the general structure poly[vinyl-3-(dialkylamino)alkylcarbamate-co-vinyl acetate-co-vinyl alcohol]-graft-poly(d,l-lactide-co-glycolide) have shown potential for nano- and micro-scale drug delivery systems. For further optimization of this polymer class their cytotoxicity needs to be characterized establishing structure-toxicity relationships. Effects of type and degree of amine substitution as well as molecular weight on cytotoxicity were evaluated in L929 mouse fibroblasts using a MTT assay whereas interactions with cell membranes were quantified by LDH release and caspase (3/7)-activation. Finally, direct cell-polymer contact assays were conducted. Ungrafted amine-modified polymer backbone yielded IC(50) values in the range of 0.05-10mg/ml. Generally higher toxicities were observed with an increasing degree of amine substitution. Amine substituents could be ranked as diethylaminopropylamine (DEAPA)<diethylaminoethylamine (DEAEA)<dimethylaminopropylamine (DMAPA) but the degree of amine substitution was more dominant than the type of amine function. Membrane interactions seem to cause necrotic cell reactions in a dose-dependent manner for highly charged amine-poly(vinyl alcohol) (PVA) backbones. To attenuate cytotoxic effects DEAPA-PVA backbones were grafted with biodegradable PLGA side chains at molecular ratios of 1:10 and 1:20. Cytotoxicity of extracts of these polymers was significantly lower compared to ungrafted polymers possibly caused by shielding of polycationic backbone with hydrophobic PLGA side chains. P(33)-20, a polymer containing a sufficiently high degree of amine substitution could serve as a lead candidate for further investigations. In conclusion, structure-toxicity relationships could be established and shielding the polycationic backbone using PLGA side chains seems to be a promising strategy meriting further investigations.

Animals↗

Bone targeting potential of bisphosphonate-targeted liposomes. Preparation, characterization and hydroxyapatite binding in vitro.

The main constituent of bone is hydroxyapatite (HAP). Since HAP is only present in 'hard' tissues like bone and teeth, it represents a promising target for the selective drug delivery to bone. Due to the exceptional affinity of bisphosphonates (BP) for HAP, cholesteryl-trisoxyethylene-bisphosphonic acid (CHOL-TOE-BP), a new tailor-made BP derivative, was used as bone targeting moiety for liposomes. CHOL-TOE-BP-targeted liposomes were designed for the treatment of bone-related diseases to achieve prolonged local exposure to high concentrations of the bioactive compounds, thereby enhancing therapeutic efficacy and minimizing systemic side effects. The CHOL-TOE-BP-targeted liposomes were characterized regarding particle size and zeta potential. To study the bone targeting potential of these conjugates, an in vitro HAP binding assay was established. The obtained binding data indicate that CHOL-TOE-BP is useful as targeting device for liposomal drug delivery to bone.

Binding Sites↗

Poly(ethylene carbonate): a thermoelastic and biodegradable biomaterial for drug eluting stent coatings?

A first feasibility study exploring the utility of poly(ethylene carbonate) (PEC) as coating material for drug eluting stents under in vitro conditions is reported. PEC (Mw 242 kDa, Mw/Mn=1.90) was found to be an amorphous polymer with thermoelastic properties. Tensile testing revealed a stress to strain failure of more than 600%. These properties are thought to be advantageous for expanding coated stents. In vitro cytotoxicity tests showed excellent cytocompatibility of PEC. Based on these findings, a new stenting concept was suggested, pre-coating a bare-metal stent with PPX-N as non-biodegradable basis and applying a secondary PEC coating using an airbrush method. After manual expansion, no delamination or destruction of the coating could be observed using scanning electron microscopy. The surface degradation-controlled release mechanism of PEC may provide the basis for "on demand" drug eluting stent coatings, releasing an incorporated drug predominantly at an inflamed implantation site upon direct contact with superoxide-releasing macrophages. As a release model, metal plates of a defined size and area were coated under the same conditions as the stents with PEC containing radiolabelled paclitaxel. An alkaline KO(2-) solution served as a superoxide source. Within 12 h, 100% of the incorporated paclitaxel was released, while only 20% of the drug was released in non-superoxide releasing control buffer within 3 weeks.

Animals↗

Investigation of the proinflammatory potential of biodegradable nanoparticle drug delivery systems in the lung.

Particulate nanocarriers have been praised for their advantageous drug delivery properties in the lung, such as avoidance of macrophage clearance mechanisms and long residence times. However, instilled non-biodegradable polystyrene nanospheres with small diameters and thus large surface areas have been shown to induce pulmonary inflammation. This study examines the potential of biodegradable polymeric nanoparticles composed of poly(lactic-co-glycolic acid) (PLGA) and the novel PLGA derivative, diethylaminopropylamine polyvinyl alcohol-grafted-poly(lactic-co-glycolic acid) (DEAPA-PVAL-g-PLGA), to provoke inflammatory responses in the murine lung after intratracheal instillation. Lactate dehydrogenase (LDH) release, protein concentration, MIP-2 mRNA induction, and polymorphonucleocyte (PMN) recruitment in the bronchial alveolar lavage fluid (BALF) were used to evaluate an inflammatory response in Balb-C mice. Two sizes of polystyrene (PS) nanospheres (diameters: 75 nm and 220 nm) were included in the study for comparison. All nanoparticle suspensions were instilled at concentrations of 1 microg/microl and 2.5 microg/microl, representative of an estimated "therapeutic dose" and a concentrated "dose" of particles. In all experiments, the 75 nm PS particles exhibited elevated responses for the inflammatory markers investigated. In contrast, biodegradable particles of comparable hydrodynamic diameter showed a significantly lower inflammatory response. The most marked differences were observed in the extent of PMN recruitment. While the 75 nm and 220 nm PS nanospheres exhibited 41 and 74% PMN within the total BALF cell population after 24 h, respectively, PMN recruiting in lungs instilled with both types of biodegradable particles did not exceed values of the negative isotonic glucose control. In conclusion, evidence suggests that biodegradable polymeric nanoparticles designed for pulmonary drug delivery may not induce the same inflammatory response as non-biodegradable polystyrene particles of comparable size.

Animals↗

Nano-carriers for DNA delivery to the lung based upon a TAT-derived peptide covalently coupled to PEG-PEI.

Gene therapy aimed at the respiratory epithelium holds therapeutic potential for diseases such as cystic fibrosis and lung cancer. Polyethylenimine (PEI) has been utilized for gene delivery to the airways. In this study, we describe a new modification of PEI, in which an oligopeptide related to the protein transduction domain of HIV-1 TAT was covalently coupled to 25 kDa PEI (PEI) through a heterobifunctional polyethylenglycol (PEG) spacer resulting in a TAT-PEG-PEI conjugate. Improved DNA reporter gene complexation and protection was observed for small (approximately 90 nm) polyplexes as well as significantly improved stability against polyanions, Alveofact, bronchial alveolar lining fluid and DNase. To determine polyplex toxicity in vitro, MTT assays were performed and, for in vivo testing, the mice bronchial alveolar lavage was investigated for total cell counts, quantity of neutrophils, total protein and TNF-alpha concentration. All parameters suggest significantly lower toxicity for TAT-PEG-PEI. Transfection efficiencies of both PEI and TAT-PEG-PEI polyplexes with DNA were studied under in vitro conditions (A549) and in mice after intratracheal instillation. While luciferase expression in A549 cells was much lower for TAT-PEG-PEI (0.2 ng/mg protein) than for PEI (2 ng/mg), significantly higher transfection efficiencies for TAT-PEG-PEI were detected in mice. Reporter gene expression was distributed through bronchial and alveolar tissue. Thus, TAT-PEG-PEI represents a new approach to non-viral gene carriers for lung therapy, comprising protection for plasmid DNA, low toxicity and significantly enhanced transfection efficiency under in vivo conditions.

Animals↗

Cationic microparticles consisting of poly(lactide-co-glycolide) and polyethylenimine as carriers systems for parental DNA vaccination.

Cationic microparticles for DNA adsorption were formulated by blending poly(lactide-co-glycolide) (PLGA) (50:50), with different cationic agents, either PEI 25 kDa (polyethylenimine) or CTAB (cetyl-trimethyl-ammonium-bromide). The aim was to create adjuvant delivery systems increasing the efficiency of DNA vaccines. Microparticles formulated with 10% PEI exhibited a highly positive zeta-potential, small particle sizes, in contrast to particles prepared with CTAB, which revealed highly aggregated structures in scanning electron micrographs. PEI 10% microparticles efficiently adsorbed DNA and protected DNA from enzymatic degradation. Microparticles with up to 10% PEI did not affect membrane integrity whereas CTAB particles showed higher LDH release. Transfection efficiencies were assessed using a luciferase reporter gene assay compared to naked DNA and PEI/DNA polyplexes. DNA adsorbed onto microspheres with 10% or 50% PEI generally had higher transfection efficiencies than CTAB but reached lower expression levels than PEI/DNA polyplexes alone. This documented the intact release of DNA. The mechanism of gene delivery to non-phagocytic cells was studied via covalent fluorescence labeling of both the DNA and PEI by confocal microscopy and suggested uptake of DNA. Immunization of mice was performed using plasmids encoding immunodominant antigens of Listeria monocytogenes adsorbed onto RG 502 H+PEI 10% microparticles. The efficiency was tested by intravenous challenge with an otherwise lethal dose of L. monocytogenes. PLGA+PEI microspheres can be used as adjuvant delivery systems for DNA but further optimization is necessary to exploit their full potential.

Adsorption↗

Comparative study of DNA encapsulation into PLGA microparticles using modified double emulsion methods and spray drying techniques.

Recently, several research groups have shown the potential of microencapsulated DNA as adjuvant for DNA immunization and in tissue engineering approaches. Among techniques generally used for microencapsulation of hydrophilic drug substances into hydrophobic polymers, modified WOW double emulsion method and spray drying of water-in-oil dispersions take a prominent position. The key parameters for optimized microspheres are particle size, encapsulation efficiency, continuous DNA release and stabilization of DNA against enzymatic and mechanical degradation. This study investigates the possibility to encapsulate DNA avoiding shear forces which readily degrade DNA during this microencapsulation. DNA microparticles were prepared with polyethylenimine (PEI) as a complexation agent for DNA. Polycations are capable of stabilizing DNA against enzymatic, as well as mechanical degradation. Further, complexation was hypothesized to facilitate the encapsulation by reducing the size of the macromolecule. This study additionally evaluated the possibility of encapsulating lyophilized DNA and lyophilized DNA/PEI complexes. For this purpose, the spray drying and double emulsion techniques were compared. The size of the microparticles was characterized by laser diffractometry and the particles were visualized by scanning electron microscopy (SEM). DNA encapsulation efficiencies were investigated photometrically after complete hydrolysis of the particles. Finally, the DNA release characteristics from the particles were studied. Particles with a size of <10 microm which represent the threshold for phagocytic uptake could be prepared with these techniques. The encapsulation efficiency ranged from 100-35% for low theoretical DNA loadings. DNA complexation with PEI 25?kDa prior to the encapsulation process reduced the initial burst release of DNA for all techniques used. Spray-dried particles without PEI exhibited high burst releases, whereas double emulsion techniques showed continuous release rates.

DNA↗

Modified polyethylenimines as non viral gene delivery systems for aerosol therapy: effects of nebulization on cellular uptake and transfection efficiency.

This study examined the effect of nebulization on the cellular uptake and transfection efficiency of polyplexes from four polyethylenimine (PEI) modifications: branched 25 kDa PEI (bPEI), linear 22 kDa PEI (linPEI), pegylated PEI (pegPEI) and biodegradable PEI (bioPEI). Polyplexes were aerosolized with air-jet and ultrasonic nebulizers. The aerosol was collected and used to determine complex size and zeta potential. Fluorescence-assisted cell sorting (FACS) was used to quantify the cellular association of polyplexes in primary alveolar cells (AEC), A549 cells and primary bronchial cells (BEC). Confocal laser scanning microscopic images provided information about the internalization of polyplexes. Transfection efficiencies of polyplexes were quantified via measurement of luciferase expression. All polymers were stable during nebulization, although size increases were observed after air-jet nebulization. FACS studies showed a two- to three-fold increase in polyplex association with BEC compared to A549 cells, while polyplex association with AEC was negligible. BPEI, linPEI and bioPEI polyplexes were internalized, while pegPEI polyplexes remained predominately attached to the cellular membrane. Luciferase expression was detected only in BEC and A549 cells with transfection efficiencies approximately one order of magnitude higher in BEC. All PEI modifications investigated were suitable for aerosol therapy, although cell type and polymer structure significantly influenced the uptake and transfection efficiency of the polyplexes.

Aerosols↗

Modified polyethylenimines as non-viral gene delivery systems for aerosol gene therapy: investigations of the complex structure and stability during air-jet and ultrasonic nebulization.

Polyelectrolyte complexes between DNA and polyethylenimine (PEI) are promising non-viral delivery systems for pulmonary inhalation gene therapy and thus require sufficient stability during nebulization. The structure and stability of four different PEI-DNA polyplexes, namely branched (bPEI), linear (linPEI), poly(ethylene glycol)-grafted PEI (PEGPEI), biodegradable (bioPEI) PEI with DNA, were investigated. Using atomic force microscopy, the morphology of DNA and polyplexes before and after both air-jet and ultrasonic nebulization was characterized. The influence of nebulization on physico-chemical properties, particle size and zeta potential, was studied. Efficient DNA condensation to spherical particles was achieved with bPEI (90 nm) and PEGPEI (110 nm). By contrast, incomplete DNA condensations, seen as flower structures, were observed with linPEI (110 nm) and bioPEI (105 nm). Air-jet nebulization altered the polyplex structure to a greater extent than ultrasonic nebulization and resulted mainly in smaller and non-spherical particles (30-200 nm). Ultrasonic nebulization did not change the spherical structure or particle size of the polyplexes. In particular, the shape and size of the PEGPEI polyplexes did not change. We conclude that ultrasonic nebulization is a milder aerosolization method for gene delivery systems based on PEI. Additionally, PEGPEI-DNA polyplexes seem to be more stable than their counterparts, which may be advantageous in pulmonary inhalation gene therapy.

Aerosols↗

In situ forming parenteral drug delivery systems: an overview.

Biodegradable injectable in situ forming drug delivery systems represent an attractive alternative to microspheres and implants as parenteral depot systems. Their importance will grow as numerous proteins will lose their patent protection in the near future. These devices may offer attractive opportunities for protein delivery and could possibly extend the patent life of protein drugs. The controlled release of bioactive macromolecules via (semi-) solid in situ forming systems has a number of advantages, such as ease of administration, less complicated fabrication, and less stressful manufacturing conditions for sensitive drug molecules. For these reasons, a number of polymeric drug delivery systems with the ability to form a drug reservoir at the injection site are under investigation. Here, we review various strategies used for the preparation of in situ forming parenteral drug depots and their potential benefits/draw-backs, especially with regard to the delivery of protein drug candidates.

Animals↗

Microencapsulation of hydrophilic drug substances using biodegradable polyesters. Part II: Implants allowing controlled drug release--a feasibility study using bisphosphonates.

The prolonged delivery of hydrophilic drug salts from hydrophobic polymer carriers at high drug loading is an ambitious goal. Pamidronate disodium salt (APD) containing implants prepared from spray-dried microparticles were investigated using a laboratory ram extruder. An APD-containing polymer matrix consisting of an APD-chitosan implant embedded in the biodegradable polymer D,L-poly(lactide-co-glycolide acid-glucose) (PLG-GLU) was compared with a matrix system with the micronized drug distributed in the PLG-GLU. The APD-chitosan matrix system showed a triphasic release behaviour at loading levels of 6.86 and 15.54% (w/w) over 36 days under in-vitro conditions. At higher loading (31.92%), a drug burst was observed within 6 days due to the formation of pores and channels in the polymeric matrix. In contrast, implants containing the micronized drug showed a more continuous release profile over 48 days up to a loading of 31.78% (w/w). At a drug loading of 46.17% (w/w), a drug burst was observed. Using micronized drug salts and reducing the surface area available for diffusion, parenteral delivery systems for highly water-soluble drug candidates were shown to be technically feasible at high drug loadings.

Adjuvants, Pharmaceutic↗

In vivo biocompatibility and biodegradation of poly(ethylene carbonate).

Biodegradation and biocompatibility of poly(ethylene carbonate) (PEC) was examined using an in vivo cage implant system. Exudate analysis showed that PEC and PEC degradation products were biocompatible and induced minimal inflammatory and wound healing responses. Adherent foreign body giant cells (FBGCs) caused pitting on the PEC surface, which led to extensive degradation over time. Data obtained from molecular weight and examination of film cross-sections in the scanning electron microscope (SEM) indicated that PEC underwent surface erosion with no change to the remaining bulk. Attenuated total reflectance infrared (ATR-FTIR) spectroscopy was used to characterize the chemical degradation. Superoxide anion released from inflammatory cells appeared to initiate an "unzipping" mechanism of degradation by deprotonation of PEC hydroxyl end groups. The resulting alkoxide ion participated in a concerted mechanism involving water and the carbonate carbonyl, leading to elimination of ethylene glycol. Carbonate ions decomposed further with release of carbon dioxide to regenerate alkoxide ion.

Absorbable Implants↗

Surfactant-free, biodegradable nanoparticles for aerosol therapy based on the branched polyesters, DEAPA-PVAL-g-PLGA.

PURPOSE: This study describes the development of surfactant-free, biodegradable nanoparticle systems with varying physicochemical properties and their suitability for pulmonary application via nebulization. METHODS: Nanoparticle suspensions were formulated from the branched polyester, diethylaminopropyl amine-poly(vinyl alcohol)-grafted-poly(lactide-co-glycolide) (DEAPA-PVAL-g-PLGA) alone, as well as with increasing amounts of carboxymethyl cellulose (CMC). Particle size, zeta potential, turbidity, and morphology (atomic force microscopy) were characterized. Three formulations were chosen for further study: Cationic nanoparticles without CMC, cationic nanoparticles with CMC, and anionic nanoparticles with an excess of CMC. Nanoparticle degradation was characterized, as well as stability during nebulization. Nanoparticle-cell interactions were investigated and quantified using confocal laser scanning microscopy and fluorescence spectrometry. RESULTS: Nanoparticles ranged in size from 70-250 nm and displayed zeta potentials of +58.9 to -46.6 mV. Anionic nanoparticles showed the highest stability during nebulization. The degradation rate of each nanoparticle formulation decreased with increasing amounts of CMC. Cell association was highest among cationic nanoparticles (57% and 30%, respectively), although these were not internalized. Despite a lower rate of cell association (3%), anionic nanoparticles were internalized by A549 cells. CONCLUSIONS: Surfactant-free nanoparticles from DEAPA-PVAL-g-PLGA are versatile drug delivery systems; however, only the anionic formulations investigated were proven suitable for aerosol therapy.

Aerosols↗

Effect of intravenous infusions of thiamine on the disposition kinetics of thiamine and its pyrophosphate.

BACKGROUND: Thiamine supplementation is necessary in patients with thiamine deficiency syndromes. Experimental evidence suggests that tissue uptake and the elimination of thiamine are dose-dependent. AIM: The aim of the present study was to investigate the effect of different i.v. infusion rates of thiamine on blood concentrations of thiamine and its active metabolite thiamine pyrophosphate (TPP) and on renal excretion of thiamine. METHODS: Twelve healthy subjects received in a two-period block randomized study 150 mg thiamine intravenously over either 1 or 24 h. RESULTS: The maximum blood concentrations (Cmax) of thiamine were significantly higher after the more rapid infusion (RI; 2300 ng/mL) than after the slower infusion (SI; 177 ng/mL). The AUC of thiamine was identical after both infusion protocols. There was a slightly (10%) increased AUC of TPP (P < 0.08) after SI, whereas C(max) values were comparable. Urinary excretion of thiamine was significantly decreased from 83.6% of the applied dose after RI to 57.6% after the SI. CONCLUSIONS: Our data suggest an increased tissue uptake of thiamine when it is given as an SI compared with a RI of the same dose. It is concluded, therefore, that an SI of thiamine may be superior to RI or bolus injections to treat severe deficiency syndromes.

Adult↗

Delivery of unmodified bioactive ribozymes by an RNA-stabilizing polyethylenimine (LMW-PEI) efficiently down-regulates gene expression.

The sequence-specific cleavage of RNA molecules through ribozyme targeting is particularly attractive since it allows the effective abrogation of protein expression. So far, however, use of enzymatically active RNA molecules (ribozymes) has, without chemical modification, been severely hampered by ribozyme instability and poor cellular uptake. In this paper, we present a method for protection and cellular delivery of ribozymes by complexation with a low molecular weight polyethylenimine (LMW-PEI). We show that LMW-PEI almost completely stabilizes ribozymes or any RNA against degradation in vitro. Upon their highly efficient cellular uptake, non-toxic LMW-PEI-complexed ribozymes display intracellular bioactivity already at low concentrations as demonstrated by down-regulation of two different genes in different cell lines. In vivo, LMW-PEI-complexed ribozymes were stabilized after intraperitoneal (i.p.) injections, showed prolonged circulation time and intact ribozymes were detected in the subcutaneous (s.c.) tumor mass 60 min after the injection. In addition, i.p. injections of LMW-PEI-complexed ribozymes targeted against the growth factor pleiotrophin (PTN) resulted in marked reduction of s.c. human melanoma tumor growth and of intratumoral PTN levels in a mouse xenograft model. Thus, this paper describes a novel method for exogenous delivery of any bioactive RNA ribozyme in vitro and in vivo without chemical modification.

Animals↗

Cationized human serum albumin as a non-viral vector system for gene delivery? Characterization of complex formation with plasmid DNA and transfection efficiency.

Cationized human serum albumin (cHSA) could serve as a potential non-viral vector system for gene delivery. Native human serum albumin was cationized by covalent coupling of hexamethylenediamine to the carboxyl groups resulting in a shift of the isoelectric point from pH 4-5 to 7-9. The cationized albumin underwent spontaneous self-assembly with DNA as demonstrated by retardation of CMV-nlacZ plasmid in agarose gel electrophoresis. Photon correlation spectroscopy showed a decrease of complex size with increasing cHSA/plasmid ratios. Under optimized conditions complexes were formed with 230-260 nm mean diameter and a homogenous, narrow size distribution. At room temperature complexes were stable in 0.9% sodium chloride solution pH 7.4 for 1 h without aggregation. Process parameters such as albumin concentration, incubation time, temperature, pH, order of reagent addition, the presence of bivalent ions and the ionic strength of the complexation medium all influenced the complex size. Confocal laser scanning microscopy showed interactions of a Texas Red labeled cationized albumin with cell membranes of ECV 304 cells and an enhanced endocytic uptake compared to native albumin. The potential for introducing exogeneous DNA into cells was shown using NIH 3T3 fibroblasts. Successful, albeit low reporter gene expression could be achieved in the presence of chloroquine. Under in vitro conditions no toxic effect could be observed. In conclusion, cationized albumin may have promise as a non-toxic vector for gene delivery, especially for DNA vaccination.

DNA↗

Brush-like branched biodegradable polyesters, part III. Protein release from microspheres of poly(vinyl alcohol)-graft-poly(D,L-lactic-co-glycolic acid).

Brush-like branched polyesters, obtained by grafting poly(lactic-co-glycolic acid), PLGA, onto water-soluble poly(vinyl alcohol) (PVAL) backbones, were investigated regarding their utility for the microencapsulation of proteins. Poly(vinyl alcohol)-graft-poly(lactic-co-glycolic acid), PVAL-g-PLGA, offers additional degrees of freedom to manipulate properties such as e.g. molecular weight, glass transition temperature and hydrophilicity. PLGA chain length was varied at a constant molecular weight (M(w)) of the PVAL backbone and secondly M(w) of the PVAL backbone was varied keeping the PLGA chain lengths constant. The most striking feature of these polymers is their high M(w). Microencapsulation of hydrophilic macromolecules, such as bovine serum albumin, ovalbumin, cytochrome c and FITC-dextran using a w/o/w double emulsion technique was investigated. Surface morphology, particle size, encapsulation efficiencies and protein release profiles were characterized as well. Microencapsulation of model compounds was feasible at temperatures of 0-4 degrees C with yields typically in the range of 60-85% and encapsulation efficiencies of 70-90%. Both, encapsulation efficiency and initial protein release (drug burst) were strongly affected by the glass transition temperature, T(g), of the polymer in contact with water, whereas the in vitro protein release profile depended on the PVAL-g-PLGA structure and composition. In contrast to PLGA, protein release patterns were mostly continuous with lower initial drug bursts. Shorter PLGA chains increased drug release in the erosion phase, whereas initial pore diffusion was affected by the M(w) of PVAL backbone. Release profiles from 2 to 12 weeks could be attained by modification of composition and molecular weight of PVAL-g-PLGA and merit further investigations under in vivo conditions. The in vitro cytotoxicity of PVAL-g-PLGA is comparable to PLGA and therefore, this new class of biodegradable polyesters has considerable potential for parenteral drug delivery systems.

Animals↗