A new type of surgical adhesive made from porcine collagen and polyglutamic acid.

We have developed a new adhesive for surgical use. The new adhesive is made of three components: porcine collagen, poly(L-glutamic acid) and water-soluble carbodiimides (WSC). The optimum concentration of each component was determined by measuring the time required for gel formation in experiments in vitro. Using these optimum concentrations, we applied the adhesive to wounds made on rats. A conventional fibrin glue was used as a control. Measurement of tensile strength and histological examination were performed 5, 7, 10, and 14 days after the operation. The tensile strength of wounds treated with 2.5 mg/mL collagen glue was not significantly different from that of wounds treated with fibrin glue except at 7 days after the operation (p < 0.05 by Student's t-test). Histological examination revealed that the speed of cell infiltration into, and absorption of 2.5 mg/mL collagen glue was slower than for fibrin glue, but faster than for 5.0 mg/mL collagen glue. One of the important advantages of our collagen glue is that the absorption rate of it can be controlled by the collagen concentration. Therefore, it seems to be adequate for sealing air leakage from the lung, which takes a relatively long period for recovery. Moreover it does not contain human serum, and, hence, it requires no blood donation and can be obtained with low cost.

Animals↗

Long-term implantation test and tumorigenicity of polyvinyl alcohol hydrogel plates.

Two types of flat plates made from a polyvinyl alcohol (PVA) hydrogel with a water content of 80 and 20 (PVA-H80, PVA-H20), 20 x 10 x 1 mm in size, were subcutaneously implanted into each of 50 young, male Wistar rats. As a control, a sham operation was done on another set of 50 rats (Sham Op group). The shape and transparency of the PVA hydrogel were unchanged for up to 24 months. Tumors arose in 14 rats from the PVA-H80 group. In the PVA-H20 group, tumors appeared in 15 rats. The average tumor latency was 598 +/- 109 days in the PVA-H80 and 637 +/- 94 days in the PVA-H20. There was no difference in tumor incidence between the PVA-H20 and PVA-H80 groups (p < 0.05). In the Sham Op group, no malignant tumors appeared. Histopathologically, the tumors induced by hydrogel plates were malignant tumors resembling fibrosarcoma or malignant fibrous histiocytoma. This indicates that PVA hydrogel implants also induce solid state carcinogenesis at a similarly high rate to medical grade hydrophobic material reported in a previous study.

Absorbable Implants↗

Peripheral nerve regeneration across an 80-mm gap bridged by a polyglycolic acid (PGA)-collagen tube filled with laminin-coated collagen fibers: a histological and electrophysiological evaluation of regenerated nerves.

We evaluated peripheral nerve regeneration across an 80-mm gap using a novel artificial nerve conduit. The conduit was made of a polyglycolic acid (PGA)-collagen tube filled with laminin-coated collagen fibers. Twelve beagle dogs underwent implantation of the nerve conduit across an 80-mm gap in the left peroneal nerve. In four other dogs used as negative controls, the nerve was resected and left unconnected. Histological observation showed that numerous unmyelinated and myelinated nerve fibers, all smaller in diameter and with a thinner myelin sheath than normal nerve fibers, regrew through and beyond the gap 12 months after implantation. The distribution of the regenerated axonal diameters was different from that of the normal axonal diameters. Compound muscle action potentials, motor evoked potentials, and somatosensory evoked potentials were recorded in most animals 3 months after implantation. Peak amplitudes and latencies recovered gradually, which indicating the functional establishment of the nerve connection with the target organs. In addition to the ordinary electrophysiological recoveries, potentials with distinct latencies originating from Aalpha, Adelta and C fibers became distinguishable at the 6th lumbar vertebra following stimulation of the peroneal nerve distal to the gap 12 months after implantation. The pattern of walking without load was restored to almost normal 10-12 months after implantation. Neither electrophysiological nor histological restoration was obtained in the controls. Our nerve conduit can guide peripheral nerve elongation and lead to favorable functional recovery across a wider nerve gap than previously reported artificial nerve conduits.

Animals↗

Prevention of postoperative air leakage from lungs using a purified human collagen membrane-polyglycolic acid sheet.

BACKGROUND: Human amnion has useful biomedical applications because it contains a large amount of human collagen fibers. We prepared purified human collagen membrane (HCM) from human amnion and used it to develop a new sheet by combining it with synthetic bioabsorbable polyglycolic acid (PGA) mesh. We evaluated its efficacy in preventing air leakage from the lungs of dogs. METHODS: In 20 dogs, HCM-PGA sheet (n = 5), sheets using fibrin glue with a separate application method (n = 5), a mixed application method (n = 5), and fibrin glue alone (n = 5), were used as dressing materials after partial lung resection. RESULTS: The HCM-PGA sheet using fibrin glue with a separate application method was shown to be significantly more effective by an air leakage pressure test than the other three methods. These results indicate that the HCM-PGA sheet is useful for preventing air leakage from the lung. CONCLUSIONS: The HCM-PGA sheet is more effective than conventional fibrin glue for controlling postoperative air leakage.

Amnion↗

Intrathoracic esophageal replacement in the dog with the use of an artificial esophagus composed of a collagen sponge with a double-layered silicone tube.

OBJECTIVES: Intrathoracic esophageal replacement with an artificial esophagus is considered difficult. We attempted to replace the intrathoracic esophagus with an artificial esophagus composed of a collagen sponge with a double-layered silicone tube and examined the state of host tissue regeneration. METHODS: A 5-cm long gap was created in the intrathoracic esophagus in 9 dogs and repaired by interposition of our prosthesis. The dogs were fed only by intravenous hyperalimentation for 28 days. The silicone tube was removed at 29 days after the operation, and oral feeding was reintroduced. RESULTS: One dog was put to death at each of the following times: 1, 2, 3, 3, 6, 12, and 24 months after the operation. One dog is still surviving without problems after more than 26 months. One dog died of malnutrition at 10 months. In all dogs, the host regenerated tissue had replaced the resulting gap at the time of silicone tube removal. The mucosa had fully regenerated within 3 months and the glands within 12 months. The process of stenosis and shrinkage was complete within 3 months and did not advance thereafter. The lamina muscularis mucosae were observed as islets of smooth muscle within 12 months. Although the skeletal muscle regenerated close to the anastomoses, it did not extend to the middle of the regenerated esophagus even after 24 months. CONCLUSIONS: Use of a collagen sponge with a double-layered silicone tube was shown to be feasible even in the thorax and to allow the regenerated host tissue, consisting of the mucosa, glands, and lamina muscularis mucosae, to replace the esophageal gap.

Anastomosis, Surgical↗

Facial nerve repair using a collagen conduit in cats.

We evaluated facial nerve regeneration using a collagen tube as a nerve conduit in five cats. In three 5 mm of the facial nerve were resected, a collagen tube was implanted, and a 5 mm segment of the opposite facial nerve was resected, reversed 180 degrees, and sutured back as an autologous nerve graft. In one a collagen tube was implanted on one side, and in the remaining one a 5 mm nerve segment was reversed. Histological, electrophysiological, and horseradish peroxidase labelling examinations were carried out 4-24 weeks postoperatively. Histological study showed that the nerve was well vascularised and regenerated. Electrophysiological examination confirmed the recovery of evoked electromyograms through to the regenerated axons. Horseradish peroxidase examination also confirmed restoration of the whole facial nerve. The collagen tube is an efficient nerve conduit.

Animals↗

Biodegradation and tumorigenicity of implanted plates made from a copolymer of epsilon-caprolactone and L-lactide in rat.

Flat plates made from a copolymer of epsilon-caprolactone and L-lactide (P-CL-LA) [50:50 (w/w), molecular weight 1.62 x 10(5); 20 x 10 x 1 mm size] were subcutaneously implanted into 50 young, male Wistar rats (P-CL-LA group). After 24 months the plates had become a mass of small pieces, which were concentrated in an area of 3 x 2 x 1 mm. For comparison, 50 rats were implanted with medical-grade polyethylene plates (PE group) while another set of 50 rats was subjected to the same operation but without an implant (Sham Op group). Tumors arose in 25 rats from the P-CL-LA group: 24 were malignant mesenchymal tumors at the implant sites. In the PE group, tumors appeared in 16 rats (14 at the implant sites and two ectopically). The average tumor latency was 578+/-84 days in the P-CL-LA group and 452+/-102 days in the PE group. There was no difference in tumor incidence between the P-CL-LA and PE groups (p < 0.05). In the Sham Op group, two malignant tumors appeared over 2 years. Pathologically, these induced tumors arose from the inflammatory cells surrounding the degrading fragments of P-CL-LA within the tissue capsule. This indicates that relatively slowly degrading material can induce malignant tumors at a similarly high rate to nonabsorbable medical grade PE, at least in this animal model.

Abdominal Neoplasms↗

The experimental replacement of a cervical esophageal segment with an artificial prosthesis with the use of collagen matrix and a silicone stent.

OBJECTIVE: Attempts have been made to replace esophageal defects with a variety of artificial materials. However, because of the artificial nature of the materials, problems such as infection, leakage, stricture, or dislocation could not be avoided. Therefore we have designed a new type of artificial esophagus that is gradually replaced by host tissue. METHODS: Our artificial esophagus was a two-layered tube consisting of a collagen sponge matrix and an inner silicone stent. We used it to replace 5 cm esophageal segmental defects in 43 dogs, and the inner silicone stent was removed endoscopically at weekly intervals from 2 to 4 weeks. RESULTS: In the 27 dogs from which the silicone stent was removed at 2 or 3 weeks, constriction of the regenerated esophagus progressed and the dogs became unable to swallow within 6 months. In the 16 dogs from which the silicone stent was removed at 4 weeks, highly regenerated esophageal tissue successfully replaced the defect, leaving no foreign body in the host. Moreover, the regenerated esophagi had stratified flattened epithelia, striated muscle tissue composed of an inner circular and an outer longitudinal muscle layer, and esophageal glands. CONCLUSIONS: Even in mature adult higher mammals, esophageal high-order structures can be regenerated provided that an adequate three-dimensional extracellular structure is put in place for a sufficient period.

Actins↗

Porous-type tracheal prosthesis sealed with collagen sponge.

BACKGROUND: Reconstruction of a long section of the trachea is clinically problematic. Tracheal reconstructions using prostheses have met with limited success due to local infection, hemorrhage, luminal stenosis and prosthesis dislocation. METHODS: We have designed a porous type of tracheal prosthesis in which the mesh is sealed with collagen sponge. We used this prosthesis (50 mm in length) to reconstruct the cervical trachea in 10 mongrel dogs and evaluated its efficacy. RESULTS: One dog died due to an accident with anesthesia at 6 weeks and 1 of suffocation at 10 weeks. The other 8 dogs had an uneventful postoperative course until they were killed between 6 and 24 months after implantation. At sacrifice, all the prostheses had become completely incorporated into the host. Microscopic examination revealed advanced formation of a new epithelial lining in 1 dog at 6 months, and a confluent epithelial lining was observed in another dog at 12 months. Central stenosis was not significant in any of the animals. CONCLUSIONS: This tracheal prosthesis gives good results in canine tracheal reconstruction, and appears very promising for the clinical repair of tracheal defects.

Animals↗

Intrathoracic tracheal reconstruction with a collagen-conjugated prosthesis: evaluation of the efficacy of omental wrapping.

Reconstructions of the intrathoracic trachea in 24 dogs were done with the use of 50 mm long collagen-conjugated tracheal prostheses. Omental wrapping was also done in 14 of the dogs (omentopexy group) to evaluate the efficacy of this option in comparison with results in the other 10 dogs (control group). All 24 dogs had uneventful postoperative courses and were killed at 4 weeks or 3, 6, or 12 months after the operation. Better epithelialization and fewer complications, such as mesh exposure and luminal stenosis, were observed in the omentopexy group than in the control group. Angiography and analysis of regenerated blood vessels revealed that vessel ingrowth had started within 4 weeks and that vessel formation reached its maximal point within 6 to 12 months in the omentopexy group. In contrast, revascularization of the subepithelial region in the control group was poor even after 3 months, and vessel formation continued for as long as 12 months. The differences between the two groups were considered to be mainly a result of the speed of blood vessel ingrowth into the regenerated mucosa. We conclude that our prosthesis can be used safely for intrathoracic tracheal reconstruction and that omental wrapping is a useful supplementary method that reduces the occurrence of complications.

Anastomosis, Surgical↗

Nerve regeneration across a 25-mm gap bridged by a polyglycolic acid-collagen tube: a histological and electrophysiological evaluation of regenerated nerves.

In the study reported here we have examined the nerve regeneration that occurs over a 25-mm gap using a novel biodegradable nerve guide tube. The tube was a composite of polyglycolic acid (PGA) mesh coated with collagen which was filled with neurotrophic factors. The left sciatic nerve of ten adult cats was dissected. The stumps were connected by the tube, and fixed gap. Histological examinations carried out 4-16 months after implantation of the tube revealed regeneration of well vascularized nerve tissue. Regeneration of both myelinated, unmyelinated axons and Schwann cells was confirmed by electron microscopy 5 months after surgery. Following injection of horseradish peroxidase (HRP) into a site peripheral to the regenerated segment of the sciatic nerves, motoneurons in the ventral horn of the spinal cord, afferent terminals in the medial portion of the dorsal column of the medulla oblongata, and sensory afferent nerve terminals in the dorsal horn of the spinal cord were labelled. Electrophysiological examinations revealed restoration of evoked electromyograms and sensory evoked potentials (SEPs) recorded from the cerebral cortex as well as the spinal cord. We also found that some of the regenerated motor axons exhibited branching in the regenerated segments. In two cases, a single motoneuronal axon from the regenerated side projected to both flexors and extensors, simultaneously. Our results indicate that the PGA-collagen composite tube is a promising tool for use as a nerve guide tube in peripheral nerve regeneration.

Animals↗

[Studies of resected small lung cancer associated with intrapulmonary metastasis].

We studied on intrapulmonary metastasis in 6 out of 136 cases where the resection for lung cancer was performed at Fukui Red Cross Hospital from 1984 to 1990. Four out of 6 were small lung cancer cases. The histological types were as follows: 4 adenocarcinomas and 2 squamous cell carcinomas. In adenocarcinoma cases, intrapulmonary metastasis tended to scatter to other pulmonary lobe and to increase in number. On the other hand, in squamous cell carcinoma cases, intrapulmonary metastasis was solitary and localized in the same pulmonary lobe as that of the primary lesion. Two squamous cell carcinoma cases were alive, and one of these was alive for more than 4 years in small lung cancer cases. It is suggested that in cases of intrapulmonary metastasis localized in the same pulmonary lobe as that of the primary lesion, to be expected metastatic route to be included in resected lobe, surgical operation is recommended, especially in squamous cell carcinoma cases.

Adenocarcinoma↗