A sensitive TSH assay in spot-coated microwells utilizing recombinant antibody fragments.

We have developed a novel TSH immunoassay based on a simplified test protocol suitable for point-of-care testing yet providing 3rd generation TSH assay sensitivity. The antibody density and the functional solid phase capacity were improved up to six-fold by capturing the site-specifically biotinylated recombinant Fab fragment or single chain antibody fragment onto the surface of immobilized streptavidin. An important mechanism for obtaining a low limit of detection (0.003 mIU/l) was the reduction of the coated area to a size ("spot") more closely coinciding with the excitation beam. The reporter technology was based on time-resolved fluorometric detection of inherently fluorescent europium chelates of high quantum yield. The ready-to-use assay concept employed the all-in-one (Aio!) principle--holding all assay components in a dry form in the microtitration well--to provide a simple assay protocol. Direct signal measurement from the surface was done after the washing step without a separate development step. It is concluded that size reduction and site-specific labeling of the antibodies to create a surface with high functional capacity provides a rapid, highly sensitive immunoassay.

Antibodies, Monoclonal↗

Prevalence of zeranol, taleranol and Fusarium spp. toxins in urine: implications for the control of zeranol abuse in the European Union.

There is currently little information concerning the prevalence of zeranol and taleranol in animal urine following metabolism of the naturally occurring Fusarium spp. toxins. An epidemiological study is described which involves four European Union control laboratories in which 8008 urine samples were screened for the presence of zeranol using a time-resolved fluoroimmunoassay (TR-FIA). Of these samples, 93.6% screened negative for zeranol. All samples testing positive for zeranol were then analysed with a confirmatory method. Based on the confirmatory results, the TR-FIA-positive samples were then categorized as false-positive, true-positive or 'equivocal' (zeranol/taleranol and the Fusarium spp. toxins detected). The true-positive samples represented only 0.05% of the total number of samples (n = 4). After statistical analysis, 170 of 174 equivocal samples proved to belong to a 'normal' population in which the amount of zeranol/taleranol could be related to the total amount of Fusarium spp. toxins through a linear regression with a 99% prediction interval. This suggested that the presence of zeranol in these samples might be due to in vivo metabolism of the Fusarium spp. toxins. The presence of zeranol in the four remaining 'outliers' might be attributable to zeranol abuse rather than to natural contamination. The results are of interest for control laboratories as they might provide an analytical tool to help distinguish between abuse and natural contamination in zeranol testing.

Animals↗

Development and validation of a method for the confirmation of halofuginone in chicken liver and eggs using electrospray tandem mass spectrometry.

A method is described for the quantitative confirmation of halofuginone (HFG) residues in chicken liver and eggs. This method is based on LC coupled to positive ion electrospray MS-MS of the tissue extracts, prepared by trypsin digestion of the tissues followed by liquid-liquid extraction and final clean-up using Solid Phase Extraction (SPE). The [M+H](+) ion at m/z 416 is monitored along with four transitions at m/z 398, 138, 120 and 100. The method has been validated according to the draft EU criteria for the analysis of veterinary drug residues at 15, 30 and 45 microg kg(-1) in liver and 5, 15 and 50 microg kg(-1) in eggs. The new analytical limits, CCalpha and CCbeta were calculated for liver and were 35.4 and 43.6 microg kg(-1), respectively.

Calibration↗

Interlaboratory ring test of time-resolved fluoroimmunoassays for zeranol and alpha-zearalenol and comparison with zeranol test kits.

Many zeranol immunoassay test kits cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the evaluation and application of recently published, dry reagent time-resolved fluoroimmunoassays (TR-FIA) for zeranol and the toxin alpha-zearalenol. A ring test of bovine urine fortified with zeranol and/or alpha-zearalenol in four European Union National Reference Laboratories demonstrated that the TR-FIA tests were accurate and robust. The alpha-zearalenol TR-FIA satisfactorily quantified alpha-zearalenol in urine fortified at 10-30 ng ml(-1). The specificity-enhanced zeranol TR-FIA accurately quantified zeranol in the range 2-5 ng ml(-1) and gave no false-positive results in blank urine, even in the presence of 30 ng ml(-1) alpha-zearalenol. Zeranol TR-FIA specificity was demonstrated further by analysing incurred zeranol-free urine samples containing natural Fusarium spp. toxins. The TR-FIA yielded no false-positive results in the presence of up to 22 ng ml(-1) toxins. The performance of four commercially available zeranol immunoassay test kits was more variable. Three kits produced many false-positive results. One kit produced only one potential false-positive using a protocol that was longer than that of the TR-FIA. These TR-FIAs will be valuable tools to develop inspection criteria to distinguish illegal zeranol abuse from contamination arising from in vivo metabolism of Fusarium spp. toxins.

Animals↗

Development and validation of dry reagent time-resolved fluoroimmunoassays for zeranol and alpha-zearalenol to assist in distinguishing zeranol abuse from Fusarium spp. toxin contamination in bovine urine.

Zeranol, an oestrogenic growth promoter in food animals, is banned within the European Union (EU). However, commercially available immunoassay kits for zeranol cross-react with toxins formed by naturally occurring Fusarium spp. fungi, leading to false-positive screening results. This paper describes the validation of a specificity enhanced, rapid dry reagent time-resolved fluoroimmunoassay (TR-FIA) for zeranol (recovery 99%, limit of detection 1.3 ng ml(-1)) demonstrating that up to 150 ng ml(-1) of Fusarium spp. toxins in urine do not lead to false-positive results. This assay will assist EU Member States to implement Council Directive 96/23/EC, which requires states to monitor for potential abuses of zeranol. A similar TR-FIA for the Fusarium spp. toxin alpha-zearalenol, using the same sample extract, is also described (recovery 68%, limit of detection 5.6 ng ml(-1)). Only the addition of diluted sample extract is required to perform these dry-reagent TRFIAs, the results being available within 1h of extract application. The EU-funded project 'Natural Zeranol' (FAIR5-CT97-3443) will use these fluoroimmunoassays to screen bovine urine in four Member States to gather data on the seasonality of Fusarium spp. toxin contamination of urine and the incidence of zeranol screening test positives.

Animals↗

High-throughput genetic analysis using time-resolved fluorometry and closed-tube detection.

Robust methods for genetic analysis are required for efficient exploitation of the constantly accumulating genetic information. We describe a closed-tube genotyping method suitable for high-throughput screening of genetic markers. The method is based on allele-specific probes labeled with an environment-sensitive lanthanide chelate, the fluorescence intensity of which is significantly increased upon PCR amplification of a complementary target. Genomic DNA samples were analyzed in an insulin gene single nucleotide polymorphism (SNP) assay using universal amplification primers and probes that recognized the two different alleles. The feasibility of dry reagent based all-in-one PCR assays was tested using another diabetes-related genetic marker, human leukocyte antigen DQB1 allele *0302 as a model analyte in a dual-color, closed-tube end-point assay. There was a 100% correlation between the novel SNP assay and a conventional PCR restriction fragment length polymorphism assay. It was also demonstrated that using real-time monitoring, accurate genotyping results can be obtained despite strongly cross-reacting probes, minimizing the time and effort needed for optimization of probe sequence. Throughput can be maximized by using predried PCR mixtures that are stable for at least 6 months. This homogenous, all-in-one dry reagent assay chemistry permits cost-effective genetic screening on a large scale.

Alleles↗

Utilization of kinetically enhanced monovalent binding affinity by immunoassays based on multivalent nanoparticle-antibody bioconjugates.

The monovalent binding affinity of high binding site density nanoparticle-antibody bioconjugates is shown to exceed the intrinsic affinity of the original, monoclonal antibody. The nanoparticle-antibody bioconjugates were prepared by covalent coupling of antibodies to long-lifetime fluorescent, europium(III) chelate nanoparticles, 107 nm in diameter. Experiments were carried out in standard microtitration wells to determine solid-phase association and dissociation rate constants, nonspecific binding, and affinity constants of the various binding site density nanoparticle-antibody bioconjugates and the conventionally labeled monoclonal antibody. The affinity constant for monovalent binding of a high binding site density bioconjugate (5.4 x 10(10) M(-1)) was 8-fold higher than the intrinsic affinity of the antibody (6.6 x 10(9) M(-1)). The separately measured association (2.5 x 10(6) M(-1) s(-1)) and dissociation (3.7 x 10(-5) s(-1)) rate constants of the bioconjugate were 2-fold higher and 4-fold lower, respectively, compared to the antibody. The dependence of the association rate constant of the density of the binding sites enhanced the kinetics and the affinity of the high binding site density bioconjugates. The nanoparticle labels with high specific activity, low nonspecific binding, and enhanced binding affinity of the nanoparticle-antibody bioconjugates contribute to the design of the next generation immunoassays with extreme sensitivity.

Antibodies↗

Development of highly fluorescent detection reagents for the construction of ultrasensitive immunoassays.

We developed two kinds of highly fluorescent streptavidin-based conjugates for use as universal detection reagents in ultrasensitive immunoassays. The direct conjugate was produced by covalently linking streptavidin to poly(Glu: Lys) which was labeled heavily with Eu chelates; the indirect conjugate was made by first conjugating bovine serum albumin (BSA) to poly(Glu:Lys) labeled heavily with Eu chelates and then further linking streptavidin to the conjugate of BSA-poly(Glu:Lys)-Eu chelate. Both direct and indirect conjugates were used to construct a highly sensitive time-resolved fluorometric assay for prostate-specific antigen (PSA). Of two monoclonal antibodies used in the assay, one was coated on the well surface of the microtitration strips, and the other was biotinylated. When 10 microL of sample volume was used, we found that the assay using the indirect conjugate had a detection limit of 0.006 microg/L, which was approximately 5.6-fold more sensitive than the one using Eu chelate directly labeled detection antibody and 6.8-fold more sensitive than the one using Eu chelate-labeled streptavidin. However, the assay that used the direct conjugate was 1.5-fold more sensitive than the one that utilized the indirect conjugate. When 45 microL of sample volume was used, a detection limit of 0.001 microg/L was achieved by using the direct conjugate. This improvement in sensitivity should be equally obtainable for the analytes other than PSA. We further demonstrated that the final immunoassay performance was affected not only by the quality of the streptavidin-based conjugate used but also by the quality of the biotinylated antibody reagent. The universal detection reagents described here are believed to be particularly useful for the construction of ultrasensitive time-resolved fluorometric immunoassays and are potentially applicable in other fields such as immunohistochemistry and nucleic acid detection.

Biotin↗

Simultaneous quantification of human glandular kallikrein 2 and prostate-specific antigen mRNAs in peripheral blood from prostate cancer patients.

We present a multiplexed and internally calibrated quantitative reverse transcription-PCR (QRT-PCR) assay to detect human glandular kallikrein 2 (hK2) and prostate-specific antigen (PSA) transcripts in blood samples from healthy subjects and prostate cancer (PC) patients. The assay detected 50 copies of hK2 and PSA mRNA, and 1 PSA- and 10 hK2-expressing LNCaP cells in the presence of 2.5 x 10(6) PSA- and hK2-negative cells. In PC patients, 20 of 25 and 19 of 25 gave detectable PSA and hK2 mRNAs, respectively. Number of hK2 mRNA copies was significantly higher than that of PSA mRNA copies in patients with biochemically progressive (P = 0.02) PC, and with locally advanced and metastasized (P = 0.004) PC. Patients with rapidly progressive and hormone refractory PC gave detectable hK2 mRNA only in 2 of 8 and PSA mRNA in 3 of 8 patients. Neither PSA nor hK2 mRNAs were detected in 16 healthy subjects. PSA and hK2 discriminated PC patients with biochemically progressive and advanced disease from the controls and from the aggressive distant metastatic disease. The assay provides a reliable quantification of the number of hK2 and PSA mRNA copies, allows to discriminate PC cases from healthy subjects, and offers a tool for further studies on molecular staging of PC.

Calibration↗

Dual-label detection of amplified products in quantitative RT-PCR assay using lanthanide-labeled probes.

Quantitative RT-PCR (QRT-PCR) enables the sensitive and specific detection of mRNA with a small copy number. We used the QRT-PCR method and dual-label analysis of amplification products for the detection of prostate-specific antigen (PSA) mRNA. The QRT-PCR assay employed a PSA-like internal standard (IS) mRNA, which was used to quantify the PSA mRNA copies and to control the variations during the whole assay procedure from the RNA extraction to the detection of QRT-PCR amplification products by hybridization assay. After co-amplification, the PSA and IS products were detected in a microplate using Eu3+ chelate-labeled PSA and Tb3+ chelate-labeled IS hybridization probes. The detection probes allowed the simultaneous and dual-label detection of PSA and IS products in the same microtiter well. Compared to the single-label assay, the dual-label detection improved the within- and between-assay CV% from 21.7 to 7.5 and from 36.0 to 30.3, respectively. The between- and within-assay variation of the dual-label assay was further studied using PSA-producing LNCaP cells. The cells were found to express 980 +/- 170 (mean +/- SD) copies of PSA-mRNA with the within-assay CV% of 17.7 and 890 +/- 220 (mean +/- SD) copies of PSA-mRNA with the between-assay CV% of 25.0. The methodology developed may help in future studies to obtain reliable quantification of PSA mRNA generated by circulating prostate cancer cells.

Animals↗

Solid-phase PCR with hybridization and time-resolved fluorometry for detection of HLA-B27.

BACKGROUND: Preactivated solid surfaces provide new possibilities for multiple consecutive reactions in a microtiter plate format. In this study, a combination of PCR and subsequent hybridization in the same microtiter well was applied for the detection of HLA-B27 alleles. METHODS: A multiplex solid-phase PCR to amplify the HLA-B27 alleles together with beta-actin as an amplification control gene was performed on the NucleoLink (Nunc) surface. PCR was followed by hybridization and detection with time-resolved fluorescence. For the covalent capture of the PCR primers onto the solid support via a 1-(3-dimethylamino-propyl)-3-ethylcarbodiimide hydrochloride-mediated reaction, different 5'-end modifications of oligonucleotides were tested [amination, phosphorylation, and a poly(dT)10 linker]. RESULTS: For covalent immobilization of the primers, amination of the 5' end combined with use of the poly(dT)10 linker was superior. At least 19.5% of the primer added per well was attached via a stable bond. When the standard time-resolved, fluorescence-based HLA-B27 detection system was compared with the newly developed method in a sample series of 82 genomic DNAs and the corresponding dried-blood spots, all results were in full agreement. CONCLUSIONS: The new solid-phase PCR approach can be applied for multiple-target DNA detection. PCR followed by hybridization can be accomplished in a few hours using precoated strips and dried-blood spot PCR templates.

5' Untranslated Regions↗

Europium nanoparticles and time-resolved fluorescence for ultrasensitive detection of prostate-specific antigen.

BACKGROUND: Nanoparticle-based detection technologies have the potential to improve detection sensitivity in miniature as well as in conventional biochemical assays. We introduce a detection technology that relies on the use of europium(III) nanoparticles and time-resolved fluorometry to improve the detection limit of biochemical assays and to visualize individual molecules in a microtiter plate format. METHODS: Streptavidin was covalently coated on 107-nm nanoparticles containing >30 000 europium molecules entrapped with beta-diketones. In a model assay system, these nanoparticles were used to trace biotinylated prostate-specific antigen (PSA) in a microtiter plate format. RESULTS: The detection limit (mean + 3 SD of the zero calibrator) of biotinylated PSA was 0.38 ng/L, corresponding to 10 fmol/L or 60 zeptomoles (60 x 10(-21) moles) of PSA. Moreover, single nanoparticles, representing individual PSA molecules, were visualized in the same microtiter wells with a time-resolved fluorescence microscope using a x10 objective. Single nanoparticles, possessing high specific activity, were also detected in solution by a standard time-resolved plate fluorometer. CONCLUSIONS: The universal streptavidin-coated europium(III) nanoparticle label is suitable for detection of any biotinylated molecule either in solution or on a solid phase. The europium(III) nanoparticle labeling technology is applicable to many areas of modern biochemical analysis, such as immunochemical and multianalyte DNA-chip assays as well as histo- and cytochemistry to improve detection sensitivities.

Biotinylation↗

Measurement of circulating forms of prostate-specific antigen in whole blood immediately after venipuncture: implications for point-of-care testing.

BACKGROUND: The purpose of this study was to validate the use of whole-blood samples in the determination of circulating forms of prostate-specific antigen (PSA). METHODS: Blood samples of hospitalized prostate cancer and benign prostatic hyperplasia patients were collected and processed to generate whole-blood and serum samples. Three different rapid two-site immunoassays were developed to measure the concentrations of total PSA (PSA-T), free PSA (PSA-F), and PSA-alpha(1)-antichymotrypsin complex (PSA-ACT) to detect in vitro changes in whole-blood samples immediately after venipuncture. The possible influence of muscle movement on the release of PSA from prostate gland was studied in healthy men by measuring the rapid in vitro whole-blood kinetics of PSA forms before and after 15 min of physical exercise on a stationary bicycle. RESULTS: Rapid PSA-T, PSA-F, and PSA-ACT assays were designed using a 10-min sample incubation. No significant changes were detected in the concentrations of PSA-T, PSA-F, and PSA-ACT from the earliest time point of 12-16 min compared with measurements performed up to 4 h after venipuncture. Physical exercise did not influence the concentrations of the circulating forms of PSA. Hematocrit-corrected whole-blood values of PSA-T and PSA-F forms were comparable to the respective serum values. Calculation of the percentage of PSA-F (PSA F/T ratio x 100) was similar irrespective of the sample format used, i.e., whole blood or serum. CONCLUSIONS: We found that immunodetectable PSA forms are likely at steady state immediately after venipuncture, thus enabling the use of anticoagulated whole-blood samples in near-patient settings for point-of-care testing, whereas determinations of PSA (e.g., PSA-T, PSA-F, or PSA-ACT) performed within the time frame of the office visit would provide results equivalent to conventional analyses performed in serum.

Blood Specimen Collection↗

Supersensitive time-resolved immunofluorometric assay of free prostate-specific antigen with nanoparticle label technology.

BACKGROUND: The extreme specific activity of the long-lifetime fluorescent europium(III) chelate nanoparticles and the enhanced monovalent binding affinity of multivalent nanoparticle-antibody bioconjugates are attractive for noncompetitive immunoassay. METHODS: We used a noncompetitive, two-step immunoassay design to measure free prostate-specific antigen (PSA). Europium(III) chelate nanoparticles (107 nm in diameter) were coated with a monoclonal anti-PSA antibody (intrinsic affinity, 6 x 10(9) L/mol). The nanoparticle-antibody bioconjugates had an average of 214 active binding sites per particle and a monovalent binding affinity of 7 x 10(10) L/mol. The assay was performed in a low-fluorescence microtitration well passively coated with an another monoclonal anti-PSA antibody (affinity, 2 x 10(10) L/mol), and the europium(III) fluorescence was measured directly from the bottom of the well by a standard time-resolved microtitration plate fluorometer. RESULTS: The detection limit (mean + 2 SD) was 0.040 ng/L (7.3 x 10(5) molecules/mL), and the dynamic detection range covered four orders of magnitude in a 3-h total assay time. The imprecision (CV) over the whole assay range was 2-10%. The detection limit of the assay was limited by the fractional nonspecific binding of the bioconjugate to the solid phase (0.05%), which was higher than the nonspecific binding of the original antibody (<0.01%). CONCLUSIONS: The sensitivity of the new assay is equal to that of the ambient-analyte, microspot immunoassay and will be improved by use of optimized, high binding-site density nanoparticle-antibody bioconjugates with reduced nonspecific binding and improved monovalent binding affinity.

Acetates↗

Time-resolved fluorescence imaging for specific and quantitative immunodetection of human kallikrein 2 and prostate-specific antigen in prostatic tissue sections.

OBJECTIVES: To design protocols for specific and quantitative immunohistochemical detection of human kallikrein 2 (hK2) using lanthanide chelate-labeled monoclonal antibodies (Mabs) and time-resolved fluorescence imaging. METHODS: Anti-prostate-specific antigen (PSA) Mabs were tested in microtiterplate assays for their ability to prevent PSA from cross-reacting with the anti-hK2 Mab 6H10. Europium-labeled 6H10 and terbium-labeled anti-PSA Mab 2E9, selected as the best blocker antibody, were used for dual-label immunodetection in routinely fixed benign (n = 7) and malignant (n = 5) prostate specimens. The amounts of IgG bound in tissue were calculated from drops containing known Mab concentrations. RESULTS: The use of anti-PSA Mab 2E9 for blocking diminished the cross-reaction from 5% to 0.3%. In the analyzed tissues, there was considerable variation in staining intensity for both proteins; PSA signals varied from 0.1 to 36.6 times that of hK2, with on average 10-fold more bound anti-PSA Mab than anti-hK2 Mab. In malignant tissue, the amounts of bound IgGs were lower and more variable than in benign tissue using both the anti-PSA Mab and the anti-hK2 Mab. The variation in signal intensities for PSA and hK2 correlated significantly in benign tissue (P >0.05), but not in benign hyperplastic and malignant specimens (P <0.05). CONCLUSIONS: Quantification of two lanthanide chelate-labeled antibodies bound in the same tissue section enabled comparison of PSA and hK2 content in individual cells. The average cellular content of hK2 relative to that of PSA was consistent with previous mRNA studies. The time-resolved fluorescence imaging-based quantification method has universal applicability in fixed tissue specimens.

Antibodies, Monoclonal↗

Production and characterisation of monoclonal antibodies against a very small hapten, 3-methylindole.

Monoclonal antibodies were produced against a very small (131.2 Da) hapten, 3-methylindole. Nine derivatives of 3-methylindole were synthesised with spacers ending in a carboxyl group, and coupled to immunogenic carriers and europium chelate labels. Almost all the antigens elicited an antihapten response, but the majority of the mAbs produced strongly recognised the spacer group and did not bind free 3-methylindole. However, specific antibodies were obtained with five immunogens. Specificity could be directed against the pyrrole ring by locating the bridging group to the aromatic moiety of the indole ring system. Any modification in the position 3 of the indole ring strongly hindered mAb binding to the compound, and the cross-reactivity of physiologically important compounds, such as tryptophan and tryptamine, was negligible for all of the mAbs. The developed hapten structures successfully focused antibody recognition to the important sub-determinants in the indole ring system. Similar constructs could also be useful in the development of antibodies against other indolic compounds.

Antibodies, Monoclonal↗

A new label technology for the detection of specific polymerase chain reaction products in a closed tube.

A novel signal generation principle suitable for real time and end-point detection of specific PCR products in a closed tube is described. Linear DNA probes were labeled at their 5'-ends with a stable, fluorescent terbium chelate. The fluorescence intensity of this chelate is lower when it is coupled to single-stranded DNA than when the chelate is free in solution. The synthesized probes were used in the real time monitoring of PCR using a prototype instrument that consisted of a fluorometer coupled to a thermal cycler. When the probe anneals to a complementary target amplicon, the 5'-->3' exonucleolytic activity of DNA polymerase detaches the label from the probe. This results in an enhanced terbium fluorescence signal. Since terbium has a long excited state lifetime, its fluorescence can be measured in a time-resolved manner, which results in a low background fluorescence and a 1000-fold signal amplification. The detection method is quantitative over an extremely wide linear range (at least 10-10(7)initial template molecules). The label strategy can easily be combined with existing label technologies, such as TaqMan 5'-exonuclease assays, in order to carry out multiplex assays that do not suffer from overlapping emission peaks of the fluorophores.

Chelating Agents↗

N-terminal mutations in the anti-estradiol Fab 57-2 modify its hapten binding properties.

Recombinant antibodies often contain N-terminal mutations arising from the use of degenerate cloning primer sets and/or the introduction of restriction sites in the framework 1 regions. We studied the effects of such mutations in a recombinant anti-estradiol Fab fragment derived from the hybridoma cell line 57-2. The 5' ends of the heavy and light chain genes were originally modified to introduce the restriction sites XhoI and SacI, respectively, for cloning purposes. However, the affinity and specificity of the recombinant Fab were lowered compared to the proteolytic Fab' fragment of the parental hybridoma IgG. Replacing the mutated sites with authentic amino acid coding sequences restored the binding properties as well as increased the bacterial production levels fivefold and 10-fold at 30 and 37 degrees C, respectively. Local changes in the antigen binding site were probed by determining the affinity constants (Kd) for estradiol and four related steroids. It was found that the mutated heavy chain amino terminus specifically increased the Kd for testosterone whereas the mutated light chain amino terminus decreased the Kd for all of the steroids to the same extent; the heavy and light chain effects were additive. Analysis of a newly determined crystal structure of the authentic Fab 57-2 in complex with estradiol suggests that mutations in the residue 2 in V(H), and 2 and 4 in the V(L) domain were those responsible for the observed effects. Their general roles as structure-determining residues for the CDR3 loops imply that similar effects can occur with other recombinant antibodies as well.

Amino Acid Substitution↗