Wavelet-based edge detection in ultrasound images.

We introduce a new wavelet-based method for edge detection in ultrasound (US) images. Each beam that is analyzed is first transformed into the wavelet domain using the continuous wavelet transform (CWT). Because the CWT preserves both scale and time information, it is possible to separate the signal into a number of scales. The edge is localized by first determining the scale at which the power spectrum, based on the wavelet transform, has its maximum value. Next, at this scale we find the position of the peak for the squared CWT. This method does not depend on any threshold, after the range of scales have been determined. We suggest a range of scales for US images in general. Sample edge detections are demonstrated in US images of straight and jagged edges of simple structures submerged in water bath, and of an abdominal aorta aneurysm phantom.

Algorithms↗

Bayesian 2-D deconvolution: a model for diffuse ultrasound scattering.

Observed medical ultrasound images are degraded representations of the true acoustic tissue reflectance. The degradation is due to blur and speckle and significantly reduces the diagnostic value of the images. To remove both blur and speckle, we have developed a new statistical model for diffuse scattering in 2-D ultrasound radio frequency images, incorporating both spatial smoothness constraints and a physical model for diffuse scattering. The modeling approach is Bayesian in nature, and we use Markov chain Monte Carlo methods to obtain the restorations. The results from restorations of some real and simulated radio frequency ultrasound images are presented and compared with results produced by Wiener filtering.

Algorithms↗

Bayesian 2-D deconvolution: effect of using spatially invariant ultrasound point spread functions.

Observed ultrasound images are degraded representations of the-true tissue reflectance. The specular reflections at boundaries between regions of different tissue types are blurred, and the diffuse scattering within homogenous regions causes speckle because of the oscillating nature of the transmitted pulse. To reduce both blur and speckle, we have developed algorithms for the restoration of simulated and real ultrasound images based on Markov random field models and Bayesian statistical methods. The algorithm is summarized here, although a more detailed description can be found in our companion paper [1]. Because the point spread function (psf) is unknown, we investigate the effects of using incorrect frequencies and sizes for the model psf during the restoration process. First, we degrade the images either with a known simulated psf or a measured psf. Then, we use different psf shapes during restoration to study the robustness of the method. We found that small variations in the parameters characterizing the psf, less than +/- 25% change in frequency, width, or length, still yielded satisfactory results. When altering the psf more than this, the restorations were not acceptable. The restorations were particularly sensitive to large increases in the restoring psf frequency. Thus, 2-D Bayesian restoration using a fixed psf may yield acceptable results as long as the true variant psfs have not varied too much during imaging.

Bayes Theorem↗

Initial experience with stereoscopic visualization of three-dimensional ultrasound data in surgery.

Initial in vivo and in vitro experiments were performed to evaluate the feasibility of stereoscopically displaying three-dimensional (3D) ultrasound data from neurosurgery, laparoscopic surgery, and vascular surgery. Stereoscopic visualization was illustrated by four video sequences, which can be downloaded from http://www.us.unimed. sintef.no/. These sequences show a brain tumor, hepatic arteries in relation to the gallbladder, a model that mimics a neuroendoscope in a cyst, and a "flight" into model of an artery with an intima flap. The experiments indicate that stereoscopic display of ultrasound data is feasible when there is sufficient contrast between the objects of interest and the surrounding tissue. True 3D vision improves perception, thus enhancing the ability to understand complex anatomic structures such as irregular lesions and tortuous vessels.

Filtration↗

SonoWand, an ultrasound-based neuronavigation system.

OBJECTIVE: We have integrated a neuronavigation system into an ultrasound scanner and developed a single-rack system that enables the surgeon to perform frameless and armless stereotactic neuronavigation using intraoperative three-dimensional ultrasound data as well as preoperative magnetic resonance or computed tomographic images. The purpose of this article is to describe our two-rack prototype and present the results of our work on image quality enhancement. DESCRIPTION OF INSTRUMENTATION: The system consists of a high-end ultrasound scanner, a modest-cost computer, and an optical positioning/digitizer system. Special technical and clinical efforts have been made to achieve high image quality. A special interface between the ultrasound instrument and the navigation computer ensures rapid transfer of digital three-dimensional data with no loss of image quality. OPERATIVE TECHNIQUE: The positioning system tracks the position and orientation of the patient, the ultrasound probe, the pointer, and various surgical instruments. This makes it possible to update the three-dimensional map during surgery and navigate by ultrasound data in a similar manner as with magnetic resonance data. METHODS: The two-rack prototype has been used for clinical testing since November 1997 at the University Hospital in Trondheim. EXPERIENCE AND RESULTS: The image quality improvements have enabled us, in most cases, to extract information from ultrasound with clinical value similar to that of preoperative magnetic resonance imaging. The overall clinical accuracy of the ultrasound-based navigation system is expected to be comparable to or better than that of a magnetic resonance imaging-based system. CONCLUSION: The SonoWand system enables neuronavigation through direct use of intraoperative three-dimensional ultrasound. Further research will be necessary to explore the potential clinical value and the limitations of this technology.

Equipment Design↗

Diffusion coefficients and solubility coefficients for gases in biological fluids and tissues: a review.

Based on a review of 166 references for diffusion and solubility coefficients in biological fluids and tissues, we have tabulated experimental values for the gases Ar, CO2, H2, He, N2, Ne, N2O, O2, and SF6. Two major conclusions can be drawn: a) for tissues, there is a scarcity of available data; and b) in general, there are significant differences between values determined by different investigators, the discrepancies being most prominent for diffusion coefficients. For water, we give numeric values of the temperature coefficients and preferred diffusion and solubility coefficients at 25 degrees and 37 degrees C. Further, we describe several methods for estimation of coefficients where experimental data are lacking. For tissues, none of the formulas described give precise predictions for all gases, but rough estimates sufficient for most qualitative work can almost always be found. In particular, the data material indicates that for all tissues other than fatty tissues consisting of mainly triacylglycerols, the solubility coefficients for water may be used as a good approximation. Except for SF6, the error in this approximation probably does not exceed 20%. In contrast, diffusion coefficients for most tissues are from 25 to 50% lower than the respective coefficients in water, generally increasing with the water content of the tissue.

Animals↗