Dark lumen MR colonography based on fecal tagging for detection of colorectal masses: accuracy and patient acceptance.

BACKGROUND: Magnetic resonance colonography (MRC) with fecal tagging has recently been investigated in clinical studies for the detection of polyps. We assessed fecal tagging MRC in a field trial. METHODS: Forty-two patients in a private gastroenterologic practice underwent MRC with barium-based fecal tagging (150 mL of 100% barium at each of 6 main meals before MRC) and conventional colonoscopy. Diagnostic accuracy of MRC and patient acceptance were assessed and compared with the respective results of conventional colonoscopy. RESULTS: Eighteen percent of all MRC examinations showed a remaining high stool signal in the colon that impeded a reliable inclusion or exclusion of polyps. On a lesion-by-lesion basis, sensitivities for polyp detection were 100% for polyps larger than 2 cm (n = 1), 40% for polyps between 10 and 19 mm, 16.7% for polyps between 6 and 9 mm, and 9.1% for polyps smaller than 6 mm. The main reason for the low acceptance of MRC was the barium preparation, which was rated worse than the bowel cleaning procedure with conventional colonoscopy. CONCLUSION: MRC with fecal tagging must be further optimized. The large amount of barium resulted in poor patient acceptance, and barium according to this protocol did not provide sufficient stool darkening. Other strategies, such as increasing the hydration of stool, must be developed.

Adult↗

Measuring tongue volumes and visualizing the chewing and swallowing process using real-time TrueFISP imaging--initial clinical experience in healthy volunteers and patients with acromegaly.

This study assessed both two-dimensional (2D) TrueFISP imaging for quantifying tongue volume and real-time TrueFISP imaging for evaluating chewing and swallowing in healthy volunteers and patients with acromegaly. In 50 healthy volunteers, tongue volumes were measured using a 2D TrueFISP sequence. Chewing and swallowing were visualized using a real-time TrueFISP sequence. Ten patients with acromegaly were examined twice with the same magnetic resonance imaging protocol: once prior to therapy and a second time 6 months after therapy. Prior to therapy, healthy volunteers had an average tongue volume of 140 ml for men and 90 ml for women, and patients with acromegaly had an average tongue volume of 180 ml for men and 145 ml for women. However, 6 months after therapy the mean tongue volumes in patients with acromegaly had decreased to 154 ml in the men and to 125 ml in the women. The chewing and swallowing process was normal in all volunteers. Prior to therapy, just two patients showed a chewing and swallowing pathology, which disappeared after therapy. Patients with acromegaly had larger tongue volumes than healthy volunteers, and TrueFISP imaging proved feasible for visualizing chewing and swallowing in real time and is capable of detecting possible pathologies. Furthermore, TrueFISP imaging can be used to monitor therapeutic approaches in patients with acromegaly.

Acromegaly↗

Dark-lumen MR colonography.

Magnetic resonance colonography (MRC) has been shown to be an appropriate diagnostic tool for the detection of colorectal pathologies. Recently, dark-lumen MRC has been introduced. This technique is based on the acquisition of a T1-weighted sequence after the administration of water enema and the intravenous administration of paramagnetic contrast. This report describes the underlying techniques of dark-lumen MRC concerning data acquisition and image interpretation. Furthermore, it points out the advantages of this approach as compared with conventional endoscopy or other MR methods. Possible improvements in the future such as the implementation of fecal tagging strategies to avoid bowel cleansing are discussed.

Colon↗

Diagnosis of a cardiac angiosarcoma by fluorine-18 fluordeoxyglucose positron emission tomography.

Cardiac angiosarcoma is a rare tumour entity with a poor prognosis. Early detection is difficult but important for the further course of the disease. We report on a young patient with a tumour of unknown origin and dignity of the right atrium. Magnetic resonance imaging, CT and echocardiography were sufficient in localisation, but no statement on the dignity was possible. Furthermore, staging led to ambiguous results. Malignancy could be proved by fluorine-18 fluordeoxyglucose positron emission tomography, leading to early surgery. Histology revealed a poorly differentiated angiosarcoma.

Adolescent↗

Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study.

A technique for whole-body magnetic resonance (MR) imaging in only 30 seconds was developed on the basis of a rolling table platform with integrated surface coils and real-time true fast imaging with steady-state precession. In five patients, all hepatic and pulmonary lesions with a diameter exceeding 8 mm were detected by using thoracic and abdominal helical computed tomography as the reference method. Whole-body MR imaging with real-time true fast imaging with steady-state precession is feasible and may be suitable for tumor screening and staging.

Adult↗

MR colonography without colonic cleansing: a new strategy to improve patient acceptance.

OBJECTIVE: MR colonography permits accurate detection of colonic polyps larger than 8 mm. Patient acceptance remains limited because of the need for bowel cleansing. The aim of this study was to develop and assess a strategy obviating colonic cleansing by performing MR colonography in conjunction with fecal tagging based on the oral administration of barium. SUBJECTS AND METHODS: Six healthy volunteers and six patients with suspected colorectal tumors, undergoing conventional colonoscopy within 1 week of MR imaging, were included in this study. For fecal tagging, 200 mL of a barium-containing contrast agent was ingested with each of four principal meals preceding the examination. For MR colonography, the colon was filled with a barium and water mixture while gadobenate dimeglumine (0.2 mmol/kg) was injected IV. RESULTS: The combination of fecal tagging and colonic filling with barium resulted in a homogeneously low signal throughout the colonic lumen in all 12 subjects. IV injection of gadolinium caused avid enhancement of the colonic wall. Similarly, lesions arising from the colonic wall enhanced avidly. In the six evaluated patients, MR colonography correctly identified two colonic carcinomas in two patients and one polyp in each of another two patients. CONCLUSION: Fecal tagging obviates bowel cleansing and should, therefore, enhance patient acceptance for MR colonoscopy. Barium used as the tagging agent is promising because it is inexpensive, commercially available, and characterized by an excellent safety profile.

Adult↗