On the design of active contours for medical image segmentation. A Scheme for Classification and construction.

OBJECTIVES: To provide a comprehensive bottom-up categorization of model-based segmentation techniques that allows to select, implement, and apply well-suited active contour models for segmentation of medical images, where major challenges are the high variability in shape and appearance of objects, noise, artifacts, partial occlusions of objects, and the required reliability and correctness of results. METHODS: We consider the general purpose of segmentation, the dimension of images, the object representation within the model, image and contour influences, as well as the solution and the parameter selection of the model. Potentials and limits are characterized for all instances in each category providing essential information for the application of active contours to various purposes in medical image processing. Based on prolops surgery planning, we exemplify the use of the scheme to successfully design robust 3D-segmentation. RESULTS: The construction scheme allows to design robust segmentation methods, which, in particular, should avoid any gaps of dimension. Such gaps result from different image domains and value ranges with respect to the applied model domain and the dimension of relevant subsets for image influences, respectively. CONCLUSIONS: A general segmentation procedure with sufficient robustness for medical applications is still missing. It is shown that in almost every category, novel techniques are available to improve the initial snake model, which was introduced in 1987.

Diagnostic Imaging↗

Implementation of a generalized TACT algorithm for arbitrary source-object distances.

OBJECTIVES: To implement, refine, and evaluate a generalized TACT reconstruction method that corrects for misregistration caused by uncontrolled variations in projective magnification, alleviates normalization artifacts at borders of backprojections, and exploits all available source information to minimize losses produced from projective truncations in three dimensions. METHODS: A new Java-based software application was designed and tested in vitro using clinically representive data derived from four titanium dental implants in a cadaver jaw segment. These implants were irradiated by an intra-oral X-ray machine from various angles and distances using a solid-state sensor producing 48 radiographs. Six radiopaque markers were attached to the segment facilitating inference of associated projection geometries from analyses of the distributions of their respective shadows as seen by the sensor. Three-dimensional (3D) images were produced using the new algorithm, and the results were compared with those obtained from existing code. RESULTS: Slices processed using the new program were corrected for magnification errors. The resulting 3D displays showed significantly reduced tomosynthetic blur relative to uncorrected counterparts. The new reconstructions also minimized known border artifacts and made use of all available information. These images demonstrated apparent details otherwise hidden or lost when comparably processed using the control algorithm. CONCLUSIONS: The new software reduces both misregistration and scaling artifacts in tomosynthetically reconstructed slices. Hence, these modifications are expected to increase diagnostic accuracy and facilitate the appropriate application of TACT to an enlarged set of diagnostic tasks as compared with earlier implementations of the method.

Algorithms↗

Image processing and enhancement provided by commercial dental software programs.

OBJECTIVES: To identify and analyse methods/algorithms for image processing provided by various commercial software programs used in direct digital dental imaging and to map them onto a standardized nomenclature. METHODS: Twelve programs presented at the 28th International Dental-Show, March, 2001, Cologne, Germany and the Emago advanced software were included in this study. An artificial test image, comprised of gray scale ramps, step wedges, fields with Gaussian-distributed noise, and salt and pepper noise, was synthesized and imported to all programs to classify algorithms for display; linear, non-linear and histogram-based point processing; pseudo-coloration; linear and non-linear spatial filtering; frequency domain filtering; measurements; image analysis; and annotations. RESULTS: The 13 programs were found to possess a great variety of image processing and enhancement facilities. All programs offer gray-scale image display with interactive brightness and contrast adjustment and gray-scale inversion as well as calibration and length measurements. While Emago enables arbitrary spatial filtering with user-defined masks up to 7x7 pixels in size, most programs sparsely include filters and tools for image analysis and comparison. Moreover, the naming and implementation of provided functions differ. Some functions inappropriately use standardized image processing terms to describe their operations. CONCLUSIONS: Image processing and enhancement functions are rarely incorporated in commercial software for direct digital imaging in dental radiology. Until now, comparison of software was limited by the arbitrary naming used in each system. Standardized terminology and increased functionality of image processing should be offered to the dental profession.

Algorithms↗

Virtual radiographs computed from TACT volume data as a gold standard for image registration prior to subtraction.

OBJECTIVE: To develop a three-dimensional (3D) model for quantitative analysis of image subtraction methods simulating clinical conditions and relevant to dental radiology. METHOD: A high-resolution volume representation of a formalin-preserved segment of a human maxilla was synthesized from a set of 51 digital radiographs equidistantly covering the entire sampling aperture by means of Tuned-Aperture Computed Tomography (TACT). Two-dimensional (2D) projection renderings of a 3D model were generated yielding arbitrary but well-known 2D projections with, and without, structured noise producing 'virtual radiographs'. RESULTS: Virtual radiographs were found to be similar to actual clinical images with respect to appearance, structure, and texture. Because the TACT reconstruction process allows all possible positions and orientations of source, specimen, and image plane to be simulated with negligible under sampling over a reasonable range of solid angles (sampling aperture), the resulting 3D model provided a rigorous method for establishing a truly objective gold standard (ground truth) for testing different registration techniques. CONCLUSIONS: TACT image registration can be assessed quantitatively by comparing actually observed vs theoretically professed parameters that presumably constrain the underlying projection geometries. Other attributes that vary from one method to the next, such as the use of nonlinear or region-specific techniques to facilitate registration, likewise, now can be rigorously measured by context-based methods such as quantitative determination of image similarity. Hence, a 3D model that renders idealized virtual radiographs from any desired projection geometry makes possible truly objective comparison of various digital subtraction techniques.

Algorithms↗

Computer-assisted quantification of axo-somatic boutons at the cell membrane of motoneurons.

This paper presents a system for computer-assisted quantification of axo-somatic boutons at motoneuron cell-surface membranes. Different immunohistochemical stains can be used to prepare tissue of the spinal cord. Based on micrographs displaying single neurons, a finite element balloon model has been applied to determine the exact location of the cell membrane. A synaptic profile is extracted next to the cell membrane and normalized with reference to the intracellular brightness. Furthermore, a manually selected reference cell is used to normalize settings of the microscope as well as variations in histochemical processing for each stain. Thereafter, staining, homogeneity, and allocation of boutons are determined automatically from the synaptic profiles. The system is evaluated by applying the coefficient of variation (Cv) to repeated measurements of a quantity. Based on 1856 motoneuronal images acquired from four animals with three stains, 93% of the images are analyzed correctly. The others were rejected, based on process protocols. Using only rabbit anti-synaptophysin as primary antibody, the correctness increases above 96%. Cv values are below 3%, 5%, and 6% for all measures with respect to stochastic optimization, cell positioning, and a large range of microscope settings, respectively. A sample size of about 100 is required to validate a significant reduction of staining in motoneurons below a hemi-section (Wilcoxon rank-sum test, alpha = 0.05, beta = 0.9). Our system yields statistically robust results from light micrographs. In future, it is hoped that this system will substitute for the expensive and time-consuming analysis of spinal cord injury at the ultra-structural level, such as by manual interpretation of nonoverlapping electron micrographs.

Animals↗

Addendum: B-spline interpolation in medical image processing.

This paper analyzes B-spline interpolation techniques of degree 2, 4, and 5 with respect to all criteria that have been applied to evaluate various interpolation schemes in a recently published survey on image interpolation in medical imaging (Lehmann et al., 1999). It is shown that high-degree B-spline interpolation has superior Fourier properties, smallest interpolation error, and reasonable computing times. Therefore, high-degree B-splines are preferable interpolators for numerous applications in medical image processing, particularly if high precision is required. If no aliasing occurs, this result neither depends on the geometric transform applied for the tests nor the actual content of images.

Diagnostic Imaging↗

Color line search for illuminant estimation in real-world scenes.

The estimation of illuminant color is mandatory for many applications in the field of color image quantification. However, it is an unresolved problem if no additional heuristics or restrictive assumptions apply. Assuming uniformly colored and roundly shaped objects, Lee has presented a theory and a method for computing the scene-illuminant chromaticity from specular highlights [H. C. Lee, J. Opt. Soc. Am. A 3, 1694 (1986)]. However, Lee's method, called image path search, is less robust to noise and is limited in the handling of microtextured surfaces. We introduce a novel approach to estimate the color of a single illuminant for noisy and microtextured images, which frequently occur in real-world scenes. Using dichromatic regions of different colored surfaces, our approach, named color line search, reverses Lee's strategy of image path search. Reliable color lines are determined directly in the domain of the color diagrams by three steps. First, regions of interest are automatically detected around specular highlights, and local color diagrams are computed. Second, color lines are determined according to the dichromatic reflection model by Hough transform of the color diagrams. Third, a consistency check is applied by a corresponding path search in the image domain. Our method is evaluated on 40 natural images of fruit and vegetables. In comparison with those of Lee's method, accuracy and stability are substantially improved. In addition, the color line search approach can easily be extended to scenes of objects with macrotextured surfaces.

Algorithms↗

Computer-based registration for digital subtraction in dental radiology.

OBJECTIVES: (1) To review computerized a posteriori techniques for geometry and contrast registration prior to digital subtraction in dental radiography; (2) to define a uniform notation for their methodological and technical classification and based on this key code; (3) to derive criteria for successful application of computer-based a posteriori registration for routine clinical subtraction. METHODS: All techniques are classified with respect to the (1) dimension of geometry registration; (2) origin; (3) abstraction level, and (4) linkage of features used for registration of geometry; (5) elasticity; (6) domain, and (7) parameter determination of the geometrical transform used; (8) interaction of geometrical registration; as well as (9) origin of features, (10) model of transform, and (11) interaction of procedure for contrast correction. RESULTS: With respect to clinical practicability, superior registration techniques are based on the low level abstraction of intrinsic features for both geometry and contrast registration. By approximately linking the features, a global projective transform should be generated for geometry registration by automatic methods, while automatic contrast correction should be non-parametric. This challenge is met only by one out of 36 published algorithms. Hence, although numerous computer-based techniques have been published, only a few of them are applied more than once in practice. CONCLUSION: The key code proposed in this paper is useful for technical classification of a posteriori registration methods in dental radiography and allows their objective comparison. Further investigations will focus on standardization of practicable procedures to evaluate the robustness of competing methods.

Algorithms↗

Detection of leukocytes in contact with the vessel wall from in vivo microscope recordings using a neural network.

Leukocytes play an important role in the host defense as they may travel from the blood stream into the tissue in reacting to inflammatory stimuli. The leukocyte-vessel wall interactions are studied in post capillary vessels by intravital video microscopy during in vivo animal experiments. Sequences of video images are obtained and digitized with a frame grabber. A method for automatic detection and characterization of leukocytes in the video images is developed. Individual leukocytes are detected using a neural network that is trained with synthetic leukocyte images generated using a novel stochastic model. This model makes it feasible to generate images of leukocytes with different shapes and sizes under various lighting conditions. Experiments indicate that neural networks trained with the synthetic leukocyte images perform better than networks trained with images of manually detected leukocytes. The best performing neural network trained with synthetic leukocyte images resulted in an 18% larger area under the ROC curve than the best performing neural network trained with manually detected leukocytes.

Animals↗

Survey: interpolation methods in medical image processing.

Image interpolation techniques often are required in medical imaging for image generation (e.g., discrete back projection for inverse Radon transform) and processing such as compression or resampling. Since the ideal interpolation function spatially is unlimited, several interpolation kernels of finite size have been introduced. This paper compares 1) truncated and windowed sinc; 2) nearest neighbor; 3) linear; 4) quadratic; 5) cubic B-spline; 6) cubic; g) Lagrange; and 7) Gaussian interpolation and approximation techniques with kernel sizes from 1 x 1 up to 8 x 8. The comparison is done by: 1) spatial and Fourier analyses; 2) computational complexity as well as runtime evaluations; and 3) qualitative and quantitative interpolation error determinations for particular interpolation tasks which were taken from common situations in medical image processing. For local and Fourier analyses, a standardized notation is introduced and fundamental properties of interpolators are derived. Successful methods should be direct current (DC)-constant and interpolators rather than DC-inconstant or approximators. Each method's parameters are tuned with respect to those properties. This results in three novel kernels, which are introduced in this paper and proven to be within the best choices for medical image interpolation: the 6 x 6 Blackman-Harris windowed sinc interpolator, and the C2-continuous cubic kernels with N = 6 and N = 8 supporting points. For quantitative error evaluations, a set of 50 direct digital X rays was used. They have been selected arbitrarily from clinical routine. In general, large kernel sizes were found to be superior to small interpolation masks. Except for truncated sinc interpolators, all kernels with N = 6 or larger sizes perform significantly better than N = 2 or N = 3 point methods (p << 0.005). However, the differences within the group of large-sized kernels were not significant. Summarizing the results, the cubic 6 x 6 interpolator with continuous second derivatives, as defined in (24), can be recommended for most common interpolation tasks. It appears to be the fastest six-point kernel to implement computationally. It provides eminent local and Fourier properties, is easy to implement, and has only small errors. The same characteristics apply to B-spline interpolation, but the 6 x 6 cubic avoids the intrinsic border effects produced by the B-spline technique. However, the goal of this study was not to determine an overall best method, but to present a comprehensive catalogue of methods in a uniform terminology, to define general properties and requirements of local techniques, and to enable the reader to select that method which is optimal for his specific application in medical imaging.

Diagnostic Imaging↗

Observer-independent registration of perspective projection prior to subtraction of in vivo radiographs.

OBJECTIVES: To prove that the model of perspective projection allows precise registration of intra-oral radiographs regardless of whether they have been acquired with or without individual adjustment aids and independent of the human observer or computer algorithm marking corresponding landmarks in the images and, based on in vivo radiographs, to introduce and evaluate a model-based registration method. METHODS: Five observers (three experts and two non-experts) were asked to define corresponding points in 24 pairs of in vivo dental radiographs from the same region of the same patient. The landmarks were used to fit the model of perspective projection applying the least squares method. Misplaced landmarks were detected and suppressed by analysing the quality of all subsets of landmarks with respect to the minimal residual (leaving one out method). In addition, local correlation was used to optimize the quality of registration as well as observer independence. RESULTS: Using six or more corresponding landmarks in both radiographs the correlation of the images registered was > 0.95 (S.D. < 0.063) irrespective of the observers' expertise. CONCLUSIONS: Perspective projection is a reliable model for sequentially acquired intra-oral radiographs. The co-ordinates of anatomical landmarks are useful for determining the parameters of perspective projection. Local correlation and leaving one out techniques improve the geometrical adjustment as well as observer independence. Registration is nearly independent of the actual position of the landmarks and hence independent of the observer. Our algorithm will also be useful for registration techniques based on automatically detected landmarks.

Humans↗