PubMed Health⌕ Search

Biomedical subjects

T M Turner

Publications and source records attributed to T M Turner.

At least 37 records · Page 2Linked to original sources

Effects of fixation technique on displacement incompatibilities at the bone-implant interface in cementless total knee replacement in a canine model.

Bone-implant displacements can be caused by rigid body motion and by differences in material properties of the implant and bone. In the present study of the tibial component in total knee replacement, we tested a series of tibial component fixation designs to determine how certain design features influenced the magnitude of the tangential displacement between the component and supporting bone in a canine model. The transverse expansion of the proximal tibia under static axial loading was measured in the intact tibia and then in the same bone following implantation of tibial components with different interface characteristics: cementless flat smooth, cementless flat porous-coated, cementless flat porous-coated with screws, cementless pegged porous-coated, cementless pegged porous-coated with screws, cemented pegged, and cemented pegged with screws. In all cases, the magnitude of the transverse expansion increased with higher applied loads. When the statistical analysis was restricted to the cementless interfaces, the presence/absence of the porous coating, the presence/absence of pegs, and the use of screws had no significant influence on tibial expansion. However, in an analysis including the cemented and cementless pegged components, tibial expansion was reduced with the use of screws. The magnitude of the interface motion due to these displacement incompatibilities was approximately fivefold lower than the amount of interface motion related to rigid body motion found in a separate study with the canine model. The measured expansion was similar in the intact tibiae and the implanted tibiae, suggesting that the transverse constraint in the canine proximal tibia must be provided by the surrounding cortical ring rather than the subchondral bone.

Animals↗

Distribution of Young's modulus in the cancellous bone of the proximal canine tibia.

Canine cancellous bone is used as a model for human bone in experimental orthopedic research, including models of total knee arthroplasty. Depth-force measurements produced by small-diameter indentation testing were used to derive the variation of Young's modulus over the transverse cross-sectional surface at three levels within the proximal canine tibia. At the most proximal section the presence of lateral and medial peaks of equal modulus (approximately 1100 MPa) was found. Modulus averages for the three resection levels revealed a trend of distally decreasing values, from 692 MPa proximally to 417 MPa distally. Average regional modulus values for the canine tibia were 50-75% higher than previously reported for the tibia of healthy young adult humans, although the local maxima were only 5-20% greater in canines.

Adult↗

Initial in vitro stability of the tibial component in a canine model of cementless total knee replacement.

The tibial component of a canine cementless total knee replacement model was used to determine the degree to which pegs and screws contributed to the initial in vitro stability of the device. Three implant designs were investigated: (1) a four-peg implant in which cortical bone screws passed through the pegs, (2) the four-peg implant without adjuvant screw fixation, and (3) a flat implant with screws placed in the same positions as in the first design. For measuring the interface motion, the tibial component and proximal tibia were modeled as rigid bodies and an experimental method was developed which permitted all six degrees of freedom of the motion between these two objects to be determined. In tests performed to validate this methodological approach, the potential confounding influences of tibial deformation and differential amounts of tibial deformation with the use of screws or pegs were shown to be minimal, supporting the use of the rigid-body method. In general, the areas of greatest motion were at the periphery of the bone-implant interface, regardless of whether or not screws or pegs were used. The components secured with screws had up to five-fold reductions in interface motion compared to components which had pegs but lacked screw fixation. Components with pegs and screws and components with screws only had the same amount of interface motion. Thus, in the presence of screw fixation, the addition of pegs did not increase the stability of the tibial component.

Alloys↗

Effect of pegs and screws on bone ingrowth in cementless total knee arthroplasty.

The purpose of the present study was to assess the effects of pegs and screws on bone ingrowth into the tibial component in cementless total knee replacement. Left total knee replacements were performed in 21 mature male dogs with 3 cementless porous-coated tibial tray configurations (7 animals per group): (1) 4-peg design implanted with cortical screws passing through the pegs; (2) 4-peg design implanted without screws; and (3) pegless design secured by 4 cortical screws. The animals were allowed unrestricted activity and were euthanized 6 months postoperatively. The pegless components (Group 3) had the highest extent of bone ingrowth into the tray (90.3% +/- 9.4%), followed by the components with 4 pegs only (Group 2, 82.8% +/- 9.2%), and the components with 4 pegs and 4 screws (Group 1, 75.9% +/- 11.8%). The difference between Groups 1 and 3 was statistically significant (p < 0.05). The volume fraction of bone ingrowth in the tray did not differ among the 3 groups, with an overall mean of 22.5% (+/- 4.6%). At the posterolateral quadrant, Group 1 had significantly less bone ingrowth than Group 3 within the tray whether measured as the extent (63.6% +/- 20.5% versus 91.0% +/- 10.6%, p < 0.05) or volume fraction (19.1% +/- 8.8% versus 32.9% +/- 10.5%, p < 0.05). There were no between-group differences at the other quadrants. This study indicated that pegs provided no added benefit in a circumstance where sufficient initial fixation was obtained with screws.

Animals↗

Adaptive bone remodeling around bonded noncemented total hip arthroplasty: a comparison between animal experiments and computer simulation.

Severe loss of bone related to stress-shielding is one problem threatening the long-term integrity of noncemented total hip arthroplasty. It is widely accepted that this phenomenon is caused by adaptive bone remodeling according to Wolff's law. Recently, quantitative bone-remodeling theories have been proposed, suitable for use in computer-simulation models in combination with finite-element codes, which can be applied to simulate the long-term effect of the remodeling process. In the present paper, the results of such a computer simulation are compared with those in an animal experiment. A three-dimensional finite-element model was constructed from an animal experimental configuration concerning the implantation of a fully coated femoral hip prosthesis in dogs. The simulation results of the adaptive bone-remodeling process (geometric adaptations at the periosteal surface and density adaptations within the cancellous bone) were compared with cross-sectional measurements of the canine femurs after 2 years of follow-up. The detailed comparison showed that long-term changes in the morphology of bone around femoral components of total hip replacements can be fully explained with the present quantitative adaptive bone-remodeling theory.

Adaptation, Physiological↗

Revision, without cement, of aseptically loose, cemented total hip prostheses. Quantitative comparison of the effects of four types of medullary treatment on bone ingrowth in a canine model.

A model that replicated the radiographic and histological features of aseptic loosening of the femoral component of a total hip replacement that had been done with cement was created in thirty-seven dogs. A deep wound infection developed in one dog, and that dog was excluded from the study. Revision was performed without cement in twenty-nine dogs, which were then followed for six months. The remaining seven dogs were used for histological study only. The components that were used for revision were made from Ti-6-Al-4-V, and a titanium fiber-metal porous surface had been applied to the anterior, posterior, and medial surfaces of the proximal part of the stem. The femora were revised either with no graft material applied to the osseous defect; with hydroxyapatite/beta-tricalcium phosphate placed in the defect; with application of an autologous cancellous bone graft as part of a one-stage revision; or with application of an autologous cancellous bone graft as the first part of a two-stage revision, with implantation of the component four months later. The use of an autologous bone graft led to greater and more consistent ingrowth of bone. The greatest amount of bone ingrowth was found in the group in which the procedure had been done in two stages (18 +/- 4.1 per cent), followed by the group in which the prosthesis and the graft had been inserted in a single stage (15 +/- 5.0 per cent), the group that had been treated with hydroxyapatite/beta-tricalcium phosphate (10 +/- 9.1 per cent), and the control group, in which no graft had been used (7 +/- 7.0 per cent). Notably, all of the components in the animals in which an autologous graft had been used were well fixed by bone ingrowth, while the component in two of the animals in the group in which no graft had been used in one animal in the hydroxyapatite/beta-tricalcium phosphate group had only fibrous-tissue ingrowth. In contrast to the findings with respect to bone ingrowth, there was more medullary bone adjacent to the lateral aspect of the implant in the groups in which hydroxyapatite/beta-tricalcium phosphate or no graft had been inserted than in the groups that had had an autologous graft.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Efficacy of autograft and freeze-dried allograft to enhance fixation of porous coated implants in the presence of interface gaps.

Autogenous cancellous bone and freeze-dried allogeneic cancellous bone were tested in a total of 41 adult male mongrel dogs. In each humerus, an implant with a commercially pure titanium fiber metal porous coating was placed in an overreamed cavity so that a uniform 3-mm gap was present between the implant and host cancellous bone. Graft material was placed in the gap of one humerus while the gap of the other humerus was left empty and served as a paired negative control. Histologically, both autograft and allograft appeared to aid repair of the defect, but quantitatively only autograft enhanced new bone formation within the defect. Treatment with autograft significantly increased the amount of bone ingrowth within the implants by nearly three-fold at 4 weeks and eight-fold at 8 weeks. The enhancing effect was recognizable as early as 2 weeks. The strength of fixation was increased by nearly seven-fold at 4 weeks and two-fold at 8 weeks in the autograft group, but this was only statistically significant at 4 weeks. Treatment with allograft did not enhance bone ingrowth at any time period, but had a small positive effect on strength of fixation at 4 weeks.

Analysis of Variance↗

Experimental studies of bone remodeling in total hip arthroplasty.

Experimental studies of bone remodeling after total hip arthroplasty are reviewed. Most of the studies have been motivated by the introduction of cementless hip replacements in which porous coatings are used to provide fixation by bone ingrowth. Stress shielding is thought to be the main factor responsible for bone loss after hip replacement. Experimentally, design features related to (1) the nature of the bone-implant interface and (2) stem stiffness have been tested to determine if the effects of stress shielding can be decreased. The dominant long-term design feature controlling bone remodeling in hip replacement appears to be stem stiffness.

Animals↗

Remodeling and ingrowth of bone at two years in a canine cementless total hip-arthroplasty model.

Remodeling and ingrowth of bone in association with the use of uncemented femoral components were examined at two years in a canine total hip-arthroplasty model. Twenty-two dogs received a unilateral uncemented femoral stem that was made of Ti6A14V and was covered with one of three types of titanium porous coating: fiber-metal, beads, or plasma flame-spray. The amount and distribution of ingrowth of bone differed somewhat among the groups at two years, but the patterns of remodeling of bone in the medullary canal and cortex were similar. In general, about 15 to 18 per cent of the cortical bone was lost adjacent to the levels of the stem that were covered with the porous coating. Most of the loss of cortical bone was due to subperiosteal resorption proximally and endosteal resorption at the middle and distal levels of the stem. Increased cortical porosity accounted for only a small fraction of the loss of cortical bone. The amount of medullary bone increased proximally and distally, so that the loss of total bone mass was significantly only at the mid-part of the stem. The amount of loss of cortical bone was similar to that observed in a previous six-month study, suggesting that a steady state was achieved in the present model.

Animals↗

Changes in tibial bone mass after primary cementless and revision cementless total hip arthroplasty in canine models.

The purpose of this study was to examine right-left differences in tibial bone mass after unilateral (left) cementless total hip arthroplasty (THA). Of 39 dogs with THAs, 9 had primary cementless porous-coated femoral stems for 6 months and 15 had similar stems for 2 years. Five dogs had aseptically failed cemented hips, and 10 had aseptically failed cemented hips that were revised with cementless porous-coated femoral stems (5 without bone graft and 5 with autogenous bone graft). These animals were sacrificed 6 months after the revision surgery. The primary cementless dogs showed no right-left difference in tibial bone mineral content (BMC) or cortical bone cross-sectional geometry after 6 months, but after 2 years there was a distal right-left difference in BMC of 6% caused by expansion of the medullary canal in the tibia of the operated limb. Tibial BMC was more than 20% lower in the operated limb of the failed cemented dogs, approximately 15% lower in the nongrafted group, and 7% lower in the grafted group. The right-left tibial difference in BMC in the 2-year primary cementless group is most probably because of subclinical disuse of the operated limb. Among the dogs with failed cemented stems, the lower right-left difference in the two revised groups compared with the non-revised group suggests that improved limb function after cementless revision THA may cause gain of previously lost bone.

Animals↗

The geometry of the adult canine proximal femur.

The canine is often used as a model to study functional bone adaptation after total hip replacement. To improve our understanding of the model, we defined the central tendencies and statistical variations in the cross-sectional geometry, angle of anteversion, and cervicodiaphyseal angle of the proximal femur in 15 adult male mongrel dogs and compared the results with published reports of the human femur. Numerous similarities in the cross-sectional geometry of the canine and the human femur were noted, supporting the use of the canine as a model. The two species differed in that the orientation of the principal axes in the proximal cross sections was not related to the angle of anteversion in the canine femur, whereas these angles are related in humans. In addition, the canine medullary canal is larger than the human medullary canal relative to the external dimensions of the femur, and hence the canine has relatively thinner cortical bone. This difference in femoral cross-sectional geometry may explain, in part, why the canine provides an accentuated model of bone loss in hip arthroplasty experiments.

Animals↗

Effects of radiation on fixation of non-cemented porous-coated implants in a canine model.

A non-weight-bearing porous-coated rod was implanted bilaterally in the proximal part of the humerus in thirty-five adult male mongrel dogs. In all of the animals, one limb was treated with radiation and the opposite limb served as the control. In twenty-one animals, the dose was 1000 centigrays (rads) and in fourteen, it was 500 centigrays. The strength of fixation and the volume fraction of ingrowth of bone were determined two, four, and eight weeks after the operation in the group that received 1000 centigrays and two and four weeks after the operation in the group that received 500 centigrays. Treatment with 500 centigrays had no significant effect on the strength of fixation or the amount of ingrowth of bone. In contrast, at two weeks, treatment with 1000 centigrays had reduced the strength of fixation to 50 per cent of the control value (p less than 0.01), although, at four and eight weeks, the strength of fixation was not significantly different than that in the control limb. The amount of ingrowth of bone in the irradiated limb was significantly reduced at two weeks (30 per cent of the control value) (p less than 0.01), four weeks (70 per cent of the control value) (p less than 0.05), and eight weeks (56 per cent of the control value) (p less than 0.05).

Animals↗

Bone ingrowth into the tibial component of a canine total condylar knee replacement prosthesis.

The purpose of this study was to evaluate the occurrence of bone ingrowth in a porous coated tibial component of a canine total condylar design knee replacement model. The entire undersurface of the tibial prosthesis was covered by a titanium fiber metal porous composite pad. Projecting from this surface were three short, cylindrical, fiber metal coated pegs that along with a posterior screw provided initial stabilization of the device. Left total knee replacements were performed on six dogs using alignment and cutting jigs to prepare the bony surfaces. The dogs were killed 6 months following surgery. Extensive bone ingrowth was present in all pegs of every tibial component. Bone ingrowth was present in 12% of the pad area of one component, 22.7 to 41.6% in four components, and 81.1% in another. The void spaces in other areas were filled with fibrous tissue or in the periphery of the device with fibrocartilage. Bone ingrowth in the pad was consistent in the vicinity of the pegs and was variable in regions not adjacent to the pegs, suggesting that the pegs exerted a strong influence on the pattern of bone ingrowth into the pad.

Animals↗

Symmetry of the canine femur: implications for experimental sample size requirements.

The purpose of this study was to determine the degree of bilateral variability in cross-sectional geometric properties of the adult canine proximal femur and to use these data to determine minimum detectable treatment effects in paired and independent experimental designs. Thirteen pairs of canine femora were sectioned at nine locations and 16 cross-sectional geometric properties were determined for each section location. The canine femur was found to be bilaterally symmetrical. For a given sample size, the magnitude of the detectable treatment effect was (a) smaller for diameters than for areas and area moments of inertia and (b) smaller within the middiaphysis than proximally. The data from this study can be used to estimate sample size requirements for experiments in which the treatment effect is determined by using the contralateral femur as a control. It was found that an increase from 3 to 7 animals would have a much greater effect on improving the sensitivity of an experiment than would an increase from 7 to 11 animals.

Animals↗

[Replacement of the hip joint in the dog].

Hundreds of total hip replacements in dogs have been performed at the Ohio State University of Veterinary Medicine since August 1976. Dogs with disabling diseases or conditions of the hip are candidates for the THR. The technique provides the dog with a pain free, mechanically sound ball and socket joint. The most commonly encountered complication is dislocation, while the most disastrous complication is infection. Complications can be minimized through adherence to detail during the procedure. By following strict aseptic principles, surgical technique and postoperative care, successful hip function has been achieved in 94.7% of the cases.

Animals↗

A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model.

The purposes of this study were to compare ingrowth of bone into three types of porous coating and to determine the effect of the type of porous coating and the degree of coverage of the stem on the remodeling of bone on the femoral side in cementless hip arthroplasty. A left total hip arthroplasty was performed in forty dogs. Thirty of the dogs had a titanium-alloy femoral prosthesis that had had one of three types of commercially pure titanium porous material applied along the length of the anterior and posterior surfaces of the stem: ten with sintered fiber-metal, ten with sintered beads, and ten with plasma flame-spray coating. The remaining ten dogs had a femoral component that was circumferentially coated with commercially pure titanium that was plasma flame-sprayed along the length of the stem. In each group, five animals were killed at one month and five were killed at six months. Ingrowth of bone into all three types of porous coating was observed, indicating secure fixation of all components. By six months, there was more ingrowth of bone and new medullary bone adjacent to the proximal and distal aspects of the stems compared with the middle level of the stems in all groups. No significant difference in ingrowth of bone was observed in the beaded surface (25.2 per cent) and the fiber-metal surface (16.6 per cent) at one month, but at six months there was significantly less ingrowth into the beaded surface (23.3 per cent) than into the fiber-metal surface (37.3 per cent). In all groups, a proximal-to-distal gradient of loss of cortical bone was observed by six months. The group of dogs that had the stem with the circumferential coating experienced more severe loss of bone than did the three groups that had a stem with a partial coating. The magnitude of loss of bone was dependent on the extent rather than the type of porous coating.

Animals↗

A canine cementless total hip prosthesis model.

To evaluate a porous fiber titanium composite as a fixation method, total hip arthroplasty was performed in 13 large male mongrel dogs. In seven both acetabular and femoral composites were fixed with a porous titanium fiber composite, and in the other six the acetabulum was fixed with acrylic cement. The animals were killed one, three, and six months following implantation. At autopsy all components were fixed by bony ingrowth. There was progressive remodeling of the ingrown bone and of the bone trabeculae surrounding the prosthesis in the three- and six-month animals, with gradual thickening and development of haversian structures. Cortical osteoporosis, which did not appear to be progressive, was detected in both the one- and six-month specimens.

Acetabulum↗