Development of contrast-enhanced virtual MR cholangioscopy: a feasibility study.

The purpose of this study was to examine the feasibility of contrast-enhanced virtual MR cholangioscopy (CE VMRC). Intraluminal views of the extrahepatic biliary tree were generated in ten patients undergoing abdominal MRI post mangafodipir trisodium administration employing coronal 2.5-mm 3D fast low-angle shot (FLASH) images (TR 6.8 ms, TE 2.3 ms, matrix 195 x 512) with fat saturation and a commercially available software. Contrast-enhanced VMRC was compared with single-shot turbo spin-echo T2-weighted MR cholangiography (T2 MRC) in terms of ductal visualization and artifact presence, utilizing a five-point grading scale. Four anatomic segments were evaluated: the intra- and extra-pancreatic segment of the common bile duct (CBD), and the cystic duct and the area of hepatic duct bifurcation. Both CE VMRC and T2 MRC depicted 38 of 40 segments. There were no significant differences between CE VMRC and T2 MRC in ranking ductal segments visualization ( p=0.27). The high contrast between intraluminal fluid and extraluminal tissues facilitated the generation of endoscopic views. Contrast-enhanced virtual MR cholangioscopy is a feasible technique providing endoscopic views of the CBD. Initial results show correlation of CE VMRC with projectional MR cholangiography.

Bile Ducts↗

MR enteroclysis protocol optimization: comparison between 3D FLASH with fat saturation after intravenous gadolinium injection and true FISP sequences.

The aim of this study was to introduce the true fast imaging with steady-state precession (FISP) sequence for MR enteroclysis and compare it with the already used T1-weighted fast low-angle shot (FLASH) sequence. Twenty-one patients underwent both MR and conventional enteroclysis. The MR enteroclysis examination was performed after administration of an iso-osmotic water solution through a nasojejunal catheter and the following sequences were included: (a) true FISP; and (b) 3D FLASH with fat saturation after intravenous injection of 20 mg Buscopan or 1 mg glucagon and 0.1 mmol/kg gadolinium chelates. The true FISP sequence provided images with significantly fewer motion artifacts, whereas 3D FLASH was less sensitive to susceptibility and chemical shift artifacts. The homogeneity of endoluminal opacification, wall conspicuity, and distention of the small bowel were very good to excellent and the two sequences presented no statistically significant differences here. True FISP provided significantly better overall image quality than did 3D FLASH. The true FISP sequence can provide good anatomic demonstration of the small bowel on T2-like images and could be combined with T1-weighted FLASH images for an integrated protocol of MR enteroclysis.

Adolescent↗

An individualized approach for the implantation of a humeral prosthesis with the proper retroversion in fractures.

We applied a new methodology in 7 patients with a fracture of the upper humeral head that required hemiarthroplasty, to implant a humeral prosthesis with an individualized posterior version. Our goal was to determine preoperatively the distance from the posterior edge of the bicipital groove where the lateral fin of the humeral prosthesis should sit, in order to reproduce the individual retroversion during surgery. Using three computed tomography scan sections of the upper humerus and image processing software, we estimated the above-mentioned distance in the sound humerus and implanted the prosthesis in each patient accordingly. The differences in retroversion between the left and right humeral heads permit a better approximation to normal applying this methodology than inserting the prosthesis in a standard retroversion.

Humans↗

High-efficiency non-viral transfection of primary chondrocytes and perichondrial cells for ex-vivo gene therapy to repair articular cartilage defects.

BACKGROUND: Primary perichondrial cells and chondrocytes have been used to repair articular cartilage defects in tissue engineering studies involving various animal models. Transfection of these cells with a gene that induces chondrocytic phenotype may form an ideal method to affect tissue engineering of articular cartilage. DESIGN: A protocol for high-efficiency transfection of primary perichondrial and cartilage cells was optimized. Plasmids carrying the marker beta-galactosidase (beta-gal), PTHrP and TGF-beta1 genes driven by a strong mammalian promoter were transfected into primary perichondrial cells and chondrocytes. A three-step method was used to achieve high efficiency of transfection: (1) permeabilization of primary cells using a mild detergent, (2) association of plasmid DNAs with a polycationic (poly-l-lysine) core covalently linked to a receptor ligand (transferrin), (3) introduction of cationic liposomes to form the quaternary complex. For in-vivo assessment, polylactic acid (PLA) scaffolds seeded with beta-gal transfected perichondrial cells were implanted into experimentally created osteochondral defects in rabbit knees for 1 week. RESULTS: The efficiency of transfection was determined to be over 70%in vitro. The transformed cells continued to express beta-gal, in vivo for the entire test period of 7 days. Furthermore, primary perichondrial cells transfected with TGF-beta1 and PTHrP over-expressed their cognate gene products. CONCLUSION: The ability to transfect autologous primary perichondrial cells and chondrocytes with high efficiency using a non-viral system may form a first step towards tissue engineering with these transformed cells to repair articular cartilage defects.

Animals↗

Narrow stereotactic beam profile measurements using N-vinylpyrrolidone based polymer gels and magnetic resonance imaging.

In this work, polymer gel-MRI dosimetry (using VIPAR gels), radiographic film and a PinPoint ion chamber were used for profile measurements of 6 MV x-ray stereotactic beams of 5 and 10 mm diameter. The VIPAR gel-MRI method exhibited a linear dose response up to 32 Gy. VIPAR gels were found to resolve the penumbra region quite accurately, provided that the in-plane image resolution of the related T2-map is adequate (< or = 0.53 mm). T2-map slice thickness had no significant effect on beam profile data. VIPAR measurements performed with a spatial resolution of 0.13 mm provided penumbra widths (80%-20% distance) of 1.34 and 1.70 mm for the 5 and 10 mm cones respectively. These widths were found to be significantly smaller than those obtained with the film (2.23 mm for the 5 mm cone, 2.45 mm for the 10 mm cone) and PinPoint (2.25 mm for the 5 mm cone, 2.52 mm for the 10 mm cone) methods. Regarding relative depth dose measurements, good correlation between VIPAR gel and PinPoint data was observed. In conclusion, polymer gel-MRI dosimetry can provide relatively accurate profile data for very small beams used in stereotactic radiosurgery since it can overcome, to some extent, the problems related to the finite size of conventional detectors.

Calibration↗

Contrast-enhanced magnetic resonance cholangiography versus heavily T2-weighted magnetic resonance cholangiography.

RATIONALE AND OBJECTIVES: To investigate the feasibility of contrast-enhanced magnetic resonance cholangiography (CE-MRC) and compare it with single-shot turbo spin-echo magnetic resonance cholangiography (SSTSE-MRC). METHODS: Fifteen patients with suspected metastatic liver disease (n = 10) or biliary tree abnormalities (n = 5) underwent a magnetic resonance imaging (1.5-T system) examination before and after mangafodipir administration. Contrast-enhanced MRC with a three-dimensional fast low-angle shot sequence after mangafodipir trisodium administration was compared with SSTSE-MRC. Four anatomic segments were evaluated: the intrapancreatic and extrapancreatic common bile duct segments, the cystic duct, and the area of hepatic bifurcation. Contrast-enhanced MRC and SSTSE-MRC were separately analyzed on a 5-point grading scale in terms of ductal segment visualization and lumen narrowing or dilatation. RESULTS: There was no difference (P = 0.375) in segment visualization between CE-MRC and SSTSE-MRC; 56 of the 60 segments were visualized by both techniques. In the evaluation of ductal narrowing or dilatation, nonsignificant differences (P = 0.500) were observed. Contrast-enhanced MRC was not influenced by fluid superimposition and provided additional information from background tissues. CONCLUSIONS: Contract-enhanced MRC is a feasible technique showing anatomic correlation with SSTSE-MRC, and it can in addition provide functional information. Contrast-enhanced MRC may be used in selected patients when traditional SSTSE-MRC is inconclusive.

Bile Ducts↗

MR enteroclysis imaging of Crohn disease.

Magnetic resonance (MR) enteroclysis imaging is emerging as a technique for evaluation of the small bowel in patients with Crohn disease. Administration of 1.5-2 L of isosmotic water solution through a nasojejunal catheter ensures distention of the bowel and facilitates identification of wall abnormalities. True fast imaging with steady-state precession (FISP), half-Fourier acquisition single-shot turbo spin-echo (HASTE), and postgadolinium T1-weighted three-dimensional fast low-angle shot sequences can be employed in a comprehensive and integrated MR enteroclysis examination protocol to overcome specific disadvantages of each of the sequences involved. Superficial abnormalities that are ideally delineated with conventional enteroclysis are not consistently depicted with MR enteroclysis. The characteristic transmural abnormalities of Crohn disease such as bowel wall thickening, linear ulcers, and cobblestoning are accurately shown with MR enteroclysis imaging, especially with the true FISP sequence. MR enteroclysis is comparable to conventional enteroclysis in the detection of the number and extent of involved small bowel segments and in the disclosure of luminal narrowing or prestenotic intestinal dilatation. The clinical utility of MR enteroclysis in Crohn disease has not been fully established. At present, the method may be used for follow-up studies of known disease, estimation of disease activity, and determination of the extramucosal extent and spread of the disease process.

Artifacts↗

Estimation of spleen volume using MR imaging and a random marking technique.

The aim of this study was to apply a random marking volumetric technique in MR images for estimation of spleen volume. The MR imaging was performed in phantoms and 16 patients with indications unrelated to splenic disease. Images were transferred to a workstation to perform volumetric measurements using the random marking technique and the conventional technique of manual planimetry. Two observers independently measured splenic volume in order to evaluate reproducibility of both volumetric techniques. Phantom experiments revealed that the accuracy of the random marking technique and manual planimetry was approximately the same. In vivo splenic volume measurements derived from both volumetric techniques were highly correlated (r = 0.99, p < 0.0001). For both observers intraobserver variation was found to be lower with the random marking technique than with manual planimetry. Interobserver coefficient of variation using the manual planimetry was 4.6% and was reduced to 2.9% by adopting the random marking technique. The random marking technique was almost two times faster than the manual planimetry. The combination of the random marking technique with MR imaging might provide accurate, reproducible, quick splenic volume estimations.

Female↗

Assessment of the gain transfer function of phosphors for application in medical imaging radiation detectors.

OBJECTIVE: to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. MATERIALS AND METHODS: four phosphor materials, La(2)O(2)S:Tb, Y(2)O(2)S:Tb, Y(2)O(2)S:Eu and Y(2)O(3):Eu were used in the form of fluorescent layers prepared in the laboratory. The GTF was determined at 30 kVp and 80 kVp X-ray tube voltages for various phosphor coating weights. RESULTS: La(2)O(2)S:Tb, which was the highest density and effective atomic number phosphor used, was found to exhibit the best GTF performance at 80 kVp. At 30 kVp, the yttrium based phosphors were found of increased performance. This is mainly due to the proximity of the X-ray energy to the K-absorption edge of yttrium at 17 keV. Europium activated phosphors were found to perform very well when combined with the red sensitive film and the silicon photodiode. CONCLUSION: The GTF may be a useful method for comparing and selecting phosphor materials for use in various medical imaging applications.

Diagnostic Imaging↗

MR imaging of the small bowel with a true-FISP sequence after enteroclysis with water solution.

RATIONALE AND OBJECTIVES: To evaluate a novel MR enteroclysis technique for small-bowel imaging. METHODS: Twenty-one patients with suspected small-bowel disease underwent both MR and conventional enteroclysis. MR enteroclysis was performed by injecting an iso-osmotic water solution through a nasojejunal catheter with a flow rate of 80 to 150 mL/min. A maximum of 2 L of water solution was administered. A dynamic heavily T2-weighted single-shot turbo spin-echo sequence was applied in coronal orientation to monitor the bowel filling and adequate distention. Twelve 4-mm-thick slices were acquired by using a true fast imaging with steady-state precession (true-FISP) sequence during an 18-second breath-hold interval. Small-bowel distention, wall conspicuity, homogeneity of opacification, and the presence of artifacts were subjectively evaluated by two reviewers using five-point scales. RESULTS: Chemical shift artifacts were low and ghost artifacts were absent. Susceptibility artifacts were more prominent in the ileum; motion artifacts were low in the jejunum, ileum, and ileocecal area. Homogeneity of opacification was very good in the jejunum, good to very good in the ileum, and good in the ileocecal area. Distention was very good to excellent in the jejunum and ileum and very good in the ileocecal area. Wall conspicuity was very good to excellent in the jejunum and ileum. CONCLUSIONS: MR enteroclysis with the true-FISP sequence produced high-quality images of the small bowel. Further clinical studies are required to determine the clinical efficacy of the new technique compared with conventional enteroclysis.

Artifacts↗

PT-12, a putative ras-activated proliferation-dependent gene, is expressed in patellar tendon and not in anterior cruciate ligament.

We describe a gene (PT-12) that is expressed in the patellar tendon and not in the anterior cruciate ligament. We used a recently developed polymerase chain reaction-based subtractive cDNA analysis to discover genes that are overexpressed in the patellar tendon but not expressed in the anterior cruciate ligament; the long-term objective was to find genes that are central to the self-repair of the patellar tendon, in contrast with the inability of the anterior cruciate ligament to launch a repair response following injury. PT-12 is a homologue of human S2 or mouse LLRep3 ribosomal genes, which are known to be overexpressed in highly proliferating cells. This study opens a new vista to the development of techniques and reagents to study the differences between two periarticular tissues (i.e., the patellar tendon and anterior cruciate ligament) that differ primarily in their ability to self-repair.

Animals↗

A new polymer gel for magnetic resonance imaging (MRI) radiation dosimetry.

New composition polymer gels, the N-vinylpyrrolidone argon (VIPAR) gels, were developed and investigated as MRI dosimeters. VIPAR gels were irradiated in the dose range of 0-12 Gy by a 6 MV x-ray linear accelerator and MR-scanned in a 1.5 T magnetic resonance imager. A linear relationship was found between absorbed dose and spin spin relaxation rate R2. The dose sensitivity was found to be approximately 0.1 s(-1) Gy(-1) for a gel composition of 4% w/w in N-vinylpyrrolidone, 4% w/w in N,N'-methylene-bisacrylamide, 5% w/w in gelatine type A and 87% w/w in water. This dose sensitivity was stable with time and did not deteriorate even when a boost radiation dose of 2.5 Gy was applied 15 days after the first irradiation. Good reproducibility of these results was observed when a new batch of gels was produced and used for corresponding measurements and analysis.

Gels↗

Age-related changes in the expression of cadherin-11, the mesenchyme specific calcium-dependent cell adhesion molecule.

Cadherin-11 is a calcium-dependent cell adhesion molecule that is expressed in cells of the mesenchymal lineage during embryonic development. In this study we show, for the first time, that cadherin-11 gene is expressed in the bone marrow and bone cells obtained from rabbits of various age groups. Furthermore, a quantitative measurement of gene expression revealed that cadherin-11 was expressed in young rabbits (6 week-old: open epiphysis) at a level of 6.7 x 10(5) +/- 0.7 x 10(5) molecules; in mature rabbits (8-10 month-old: closed epiphysis) at 11 x 10(5) +/- 0.9 x 10(5) molecules; and in aged rabbits (4-5 year-old) at a level of 1.2 x 10(5) +/- 0.2 x 10(5) molecules/microg total RNA. The relative level of cadherin-11 gene expression in mature rabbit marrow was found to be approximately 50% greater than in young rabbits. However, aged animals showed a reduction in cadherin-11 specific gene expression of greater than 900% as compared with mature animals. Age-related changes in bone remodeling/turnover lead to reduced bone density and high fracture risk, and since cadherins play a crucial role in tissue morphogenesis, this marked decrease may represent an index of the aging process in bone.

Age Factors↗

Myocardial iron deposition in beta-thalassemia studied by magnetic resonance imaging.

Myocardial iron deposition is a common finding in beta-thalassemia. The iron content of the myocardium was assessed using the T2 relaxation time of the heart. The T2 relaxation time of the liver and skeletal muscle was also assessed in order to study the relation of iron deposition between heart, liver and skeletal muscle. ECG gated spin echo images were obtained from thirty-eight consecutive adult thalassemic patients examined in an outpatient clinic, aged (x +/- SD) 25 +/- 6 years, using a 0.5 T system. Patients were divided into groups A and B, according to their average serum ferritin levels of the preceding five years (> or < 2000 ng/ml). Results were compared with nine controls, aged 24 +/- 7 years. Heart T2 relaxation time in the control group (x +/- SD) (48.3 +/- 5.5 msec) was higher compared to group A (28.4 +/- 6.7 msec, p < 0.001) but not to group B (43.4 +/- 7.4 msec). The T2 relaxation time of the heart correlated positively with the T2 relaxation time of the liver (r = 0.68, p < 0.001) and negatively with ferritin levels (r = -0.67, p < 0.001). There was no correlation with the T2 relaxation time of skeletal muscle. This study indicates that regularly transfused beta-thalassemia patients may present with a broad variation of heart iron deposition which, however, is related to serum ferritin levels.

Adult↗

T2 relaxation times of irradiated vertebral bone marrow in patients with seminoma.

Our purpose was to demonstrate the effects of localized radiotherapy on lumbar vertebral bone marrow with the use of quantitative MRI with measurements of T2 relaxation times. Ten patients with early stage testicular seminoma with a history of radiation therapy to a "dog-leg" field including the lumbar vertebrae underwent MR imaging of their lumbar spine using a 0.5 Tesla magnet. Five healthy subjects and two nonirradiated patients were imaged as well. The intervals from the beginning of radiotherapy to MRI examination varied from 1.5 to 52 months, and the radiation dose ranged from 3000-4200 cGy. The T2 relaxation times of the lumbar vertebral bone marrow and subcutaneous fat were calculated for each subject. Postirradiation bone marrow in irradiated seminoma patients exhibited significantly longer T2 relaxation times than nonirradiated bone marrow in controls (71.1 vs. 63.6 ms, p = 0.047, t-test). The differences between the T2 relaxation times of bone marrow and subcutaneous fat for each subject allowed for even better differentiation between irradiated patients and controls (10.4 vs. 0.4 ms, p = 0.0004, t-test). Postirradiation bone marrow had significantly longer T2 relaxation times than subcutaneous fat in irradiated patients (N = 10, 71.1 vs. 60.7 ms, p = 0.00009, t-test), while nonirradiated bone marrow had T2 relaxation times not statistically different from subcutaneous fat in nonirradiated subjects (N = 7, 63.6 vs. 63.2 ms). Measurements of T2 relaxation times of bone marrow enabled us to differentiate between irradiated seminoma patients and controls. Postirradiation bone marrow undergoes late radiation effects resulting in longer T2 relaxation times than nonirradiated bone marrow and subcutaneous fat.

Adipose Tissue↗

Radiotherapy effects on vertebral bone marrow: easily recognizable changes in T2 relaxation times.

The effect of localized radiotherapy on vertebral bone marrow was demonstrated in two patients using quantitative MRI studies with pixel-by-pixel measurement of T2 relaxation times with generation of T2 images. Conventional T1-weighted spin-echo images were obtained as well. Irradiated vertebral bone marrow was found to have longer T2 relaxation times than the neighboring nonirradiated bone marrow. These changes corresponded to the increased signal intensity on T1-weighted images and to the field of radiotherapy and were noted 2.5 to 32 mo after radiotherapy. Radiologists should be aware of the increased T2 relaxation times in irradiated bone marrow to correctly assess spinal disorders in irradiated patients. The reported T2 changes may reflect the abundance of adipose cells that proliferate in bone marrow after radiotherapy, or may indicate an additional histological change, such as bone marrow necrosis or edema. Conclusive histological proof remains to be obtained.

Bone Marrow↗

Linkage disequilibrium between the expanded (CAG)n repeat and an allele of the adjacent (CCG)n repeat in Huntington's disease patients of Greek origin.

Huntington's disease (HD) is associated with an expanded unstable (CAG)n repeat in the IT15 gene. This repeat was investigated in 44 HD patients and 59 of their relatives at risk who were members of 29 unrelated families from various parts of Greece. Abnormal elongation of the (CAG)n repeat ranging from 39 to 95 trinucleotide units was found in all but one of the 44 HD patients tested with 70% of these patients showing 42-47 repeats. The size of the expanded sequence correlated inversely with the age at disease onset (r = 0.77, p < 0.00001, n = 43). In a single sporadic case, de novo expansion of the (CAG)n repeat was detected. Twenty-four of 59 asymptomatic family members at risk showed expansion of the (CAG)n repeat in the HD range (39-56 trinucleotide units) while three had intermediate alleles (36-37 repeats). Evaluation of the adjacent polymorphic (CCG)n repeat showed a strong linkage disequilibrium between the 7-unit (CCG)n repeat allele and the HD mutation, with 51% of normal and 93% of HD chromosomes showing this allele (chi 2 = 15.55, p < 0.0001, n - 260). These data on HD patients of Greek origin are consistent with the thesis that the (CAG)n expansion is the primary gene defect of the disease and that this mutation occurred primarily on chromosomes with the (CCG)7 repeat haplotype.

Age of Onset↗