Bovine immune response to local infections. Immunization with bovine enteroviruses and quantitative studies on bovine colostral IgG.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to T Moll.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: To assess the clinical feasibility of an experimental modified angiographic system capable of real-time digital stereofluoroscopy and stereography in X-ray angiography, using a twin-focus tube and a stereoscopic monitor. METHODS: We report the experience obtained in 37 patients with a well-documented examination. The patients were examined for coronary angiography (11 cases), aortography (7 cases), pulmonary angiography (6 cases), inferior vena cava filter placement (2 cases), and cerebral angiography (11 cases). Six radiologists were asked to use stereoscopic features for fluoroscopy and angiography. A questionnaire was designed to record their subjective evaluation of stereoscopic image quality, ergonomics of the system, and its medical interest. RESULTS: Stereofluoroscopy was successfully used in 25 of 37 cases; diplopia and/or ghost images were reported in 6 cases. It was helpful for aortic catheterization in 10 cases and for selective catheterization in 5 cases. In stereoangiography, depth was easily and accurately perceived in 27 of 37 cases; diplopia and/or ghost images were reported in 4 cases. A certain gain in the three-dimensional evaluation of the anatomy and relation between vessels and lesions was noted. As regards ergonomic considerations, polarized spectacles were not considered cumbersome. Visual fatigue and additional work were variously reported. Stereoshift tuning before X-ray acquisition was not judged to be a limiting factor. CONCLUSION: A twin-focus X-ray tube and a polarized shutter for stereoscopic display allowed effective real-time three-dimensional perception of angiographic images. Our clinical study suggests no clear medical interest for diagnostic examinations, but the field of interventional radiology needs to be investigated.
In the case of non simultaneous acquisitions of stereoscopic images, an object motion biases the 3D visualisation or reconstruction. We propose a method in order to find the interpolated image between two successive frames. It supposes that the motion locally corresponds to a translation. It works in the frequential domain and uses the phase information of the DFT. A special analysis of the phase component is made and allows to find the true interpolated phase. The application to stereoscopic angiographies illustrates the method and gives good results.
The effects of passive immunization with immunoglobulin Y (IgY) on the pathogenesis of Marek's disease (MD) were examined in an experimental line of White Leghorn chickens highly susceptible to MD. Purified IgY with anti-MDV antibody activity, when injected into chicks, delayed the development of MDV viremia and lesions until 9 days postinoculation (PI) with Marek's disease virus (MDV). The blastogenic response of spleen cells to concanavallin-A was depressed at 6 days PI in the birds without passive immunization, whereas it was not totally depressed until 17 days in birds passively immunized with IgY anti-MDV antibody.