PubMed Health⌕ Search

Biomedical subjects

T Ohyama

Publications and source records attributed to T Ohyama.

At least 19 recordsLinked to original sources

Detection system of Cryptosporidium parvum oocysts by brackish water benthic shellfish (Corbicula japonica) as a biological indicator in river water.

The brackish water benthic shellfish, Corbicula japonica, was experimentally exposed to Cryptosporidium parvum oocysts at 1.51x10(4)oocysts/clam/day for 7 or 14 days. Oocysts were predominantly eliminated through the feces of Corbicula japonica in both cases by microscopic and PCR methods. The fecal excretion rates of oocysts within 4 days after the last exposure to Corbicula japonica were 87.6% for the 7-day exposure group and 86.0% for the 14-day exposure group. The tissue residue level of oocysts in the gastrointestinal tract 3 days after the last exposure was 2.7% of total exposed oocysts and that of 7 days was 1.1% for the 7-day exposure case and 1.6 and 0.5% for the 14-day exposure case, respectively, maintaining infectivity to cultured cells (HCT-8) in vitro. At the same time, field tests of Corbicula japonica for collecting oocysts showed that this clam could certainly collect Cryptosporidium parvum oocysts in the natural river and, furthermore, the gene type of C. parvum could be also identified proving its effectiveness as a biological indicator. The present study showed that the brackish water benthic shellfish Corbicula japonica may be capable of gathering and preserving Cryptosporidium parvum oocysts to a considerable extent under the natural ecological conditions, and further suggests the effectiveness of Corbicula japonica as a practical and general bioindicator for estimates of river water contamination by oocysts of Cryptosporidium parvum.

Animals↗

Influence of food platform width of mandibular removable partial denture on food mixing ability.

The aim of this study was to clarify the influence of food platform width on food mixing ability in patients with mandibular removable partial dentures (RPDs). Twelve subjects (six males and six females, mean age 56.8 years) with intact dentition except for unilaterally missing mandibular first and second molars participated in the study. The food platforms of their RPDs were made of light polymerized composite and three platform conditions were evaluated. A food platform (Control condition) had 7 mm width with a central focus on the top of the residual ridge. Narrowed platforms (5 mm) were created by trimming a lingual portion (Buccally oriented occlusion, Buccal condition) or a buccal portion (Lingually oriented occlusion, Lingual condition) from the control. Subjects chewed a standardized wax cube which provided an estimate of food mixing ability [Mixing Ability Index (MAI)] for each of the three platforms. A significant effect (P < 0.001) on the MAI was found for food platform type (repeated measures one-way analysis of variance). Tukey multiple comparisons found significant differences of MAI between Control condition (1.05 +/- 0.26) and Buccal condition (0.86 +/- 0.23) (P = 0.032), and between Control and Lingual condition (0.54 +/- 0.37) (P < 0.001). Furthermore, MAI with Lingual condition was significantly smaller than that with Buccal condition (P < 0.001). These results suggest that reduction in the width of the food platform may impair masticatory function and the buccal portion of mandibular food platform of RPD is more critical for food mixing than the lingual portion of the platform.

Composite Resins↗

Detection of improvement in the masticatory function from old to new removable partial dentures using mixing ability test.

The aim of this study was to determine the sensitivity of the Mixing Ability Test to detect improvement of masticatory function in subjects on transition from old to new removable partial dentures. Thirty-two subjects (seven males, 25 females, mean age 65.0 years) with distal extension partially edentulous area in mandible and/or maxilla participated in the study. The following reasons were presented for replacing the old removable partial dentures with new ones: fracture and/or poor fitness of retainers, extraction of abutment teeth, poor fitness of denture base, severe wear of artificial teeth and request for metal base dentures. Masticatory function with old and new removable partial dentures after an adaptation period (mean 27.4 weeks) was evaluated by the Mixing Ability Test. Subjects were asked to masticate five two-coloured wax cubes with each removable partial denture. Mixing Ability Index was obtained from the colour mixture and shape of the masticated cubes. Wilcoxon signed-rank test was used to test the difference of Mixing Ability Indexes between old and new removable partial dentures. The mixing ability indexes with new removable partial dentures (mean+/- s.d.: 0.70+/- 0.68) was significantly higher (P<0.001) than those with old removable partial dentures (-0.11+/-1.13). The results suggest that the Mixing Ability Test was capable of detecting improvement in masticatory function with new removable partial dentures.

Aged↗

The influence of altered occlusal guidance on condylar displacement during submaximal clenching.

As cited in literatures, canine protected occlusion has a potential to reduce clenching induced temporomandibular joint loadings. However, these previous studies did not perform a control of the clenching level which differed with the depending occlusal conditions. This result may be due largely to an associated reduced jaw closing muscle activity. The present study has investigated clenching induced condylar displacements with controlled clenching level. Twenty healthy human subjects (15 males and five females with an average age of 26.5 years) volunteered to participate in this study. Metallic occlusal overlays were fabricated for the lower working side canine and overlaid to the second molar and the non-working side second molar in order to simulate a canine protected occlusion, group function occlusion and bilateral balanced occlusion. Electromyographic (EMG) activity from the bilateral masseter, anterior temporalis, and posterior temporalis was recorded. These signals were rectified, summarized, and presented to each subject using an oscilloscope screen. Using this visual feedback, subjects were asked to perform clenching tasks at a 50% level of maximal voluntary contraction exerted with simulated group function occlusion and three-dimensional condylar displacements were recorded. An experimental occlusal pattern that shows statistically significant affects on condylar displacements (anova: P<0.001) was found. When compared with the simulated canine protected occlusion, the simulated group function occlusion caused smaller working side condylar displacement and the simulated bilateral balanced occlusion caused significantly smaller non-working side and working side condylar displacements. These results suggest that the increased working side tooth contacts have a potential to reduce working side joint loadings, and a balancing side contact has a potential to reduce non-working side joint loadings, under the laboratory condition where the clenching level is controlled.

Adult↗

ProNectin F-grafted-ethylene vinyl alcohol copolymer (EVAL) as a liquid type material for treating cerebral aneurysm--an in vivo and in vitro study.

The authors aimed to develop a liquid material for embolization of aneurysms. In vitro and in vivo performances of the new embolic material were examined by cell culture and using an aneurysm model made in common carotid arteries (CCAs) of adult rats. Engineered protein ProNectin F (PnF), which contains 13 sites of an arginine-glycine-aspartic acid (RGD), was grafted onto ethylene vinyl alcohol copolymer (EVAL-g-PnF). The liquid material, EVAL-g-PnF dissolved in DMSO, was infused into an aneurysm model. The blood segments were harvested 2, 5, and 14 days and examined histologically. A number of bovine coronary artery endothelial cells became able to attach to and form cobblestone-like islands on the EVAL by incorporating PnF. The aneurysm model infused with the EVAL-g-PnF solution revealed that the aneurysm lumen was filled with proliferated fibroblasts and macrophages. On the other hand, the aneurysm model treated with unmodified EVAL showed that the cavity was almost filled with EVAL mass and that fibroblasts and macrophages filled a narrow space between the EVAL mass and the cavity wall. The results indicate that EVAL-g-PnF could be more suitable for reorganizing the cavity of an aneurysm than native EVAL.

Aneurysm↗

Finite element contact stress analysis of the RPD abutment tooth and periodontal ligament.

OBJECTIVES: The purpose of this study was to determine the influence of the occlusal rest position in removable partial dentures on the displacement of the abutment tooth and the stress distribution in the periodontal ligament (PL). METHODS: We constructed three-dimensional finite element models of the mandibular first and second premolars. A layer of the PL and a mesial or distal occlusal rest were produced on the second premolar as an abutment. A zero displacement was prescribed on the outer surface of the PL and the first premolar. In each simulation, the rest was moved 0.05 mm vertically to the apical direction, with or without restriction of horizontal movements. We simulated the contact phenomena on the abutment surfaces, and calculated the movements of the abutment and stress distributions in the PL. RESULTS: We observed a maximum distal displacement of 42 microm at the buccal cusp of the abutment and a principal compressive stress of 0.35 MPa in the PL when the abutment was vertically loaded by a distal rest that was allowed to move horizontally. However, the displacements and stresses were relatively small, and were all within the physiological limitations of the tissues. The restriction of the horizontal movement of the rests was effective in reducing the horizontal displacements of the abutment, regardless of the rest position. CONCLUSIONS: The single vertical load exerted from either the mesial or distal rest on the abutment was unlikely to cause any mechanical damage to its supporting tissues.

Bicuspid↗

Salmonella Enteritidis outbreak associated with a school-lunch dessert: cross-contamination and a long incubation period, Japan, 2001.

A Salmonella Enteritidis (SE) outbreak in Japan was investigated with an observational study, analytical epidemiology and bacteriological examination (including phage typing). The outbreak occurred among 96 schoolchildren, and was caused by SE phage type 1. The outbreak source was dessert buns served at a school lunch (RR 42.55, 95 % CI 5.93-305.11, P < 0.001). The buns were probably cross-contaminated from eggs from a factory with a history of SE-contaminated products. The incubation period was longer than usual (3-16 days, median 8 days). A low contaminating dose may account for the long incubation period and low attack rate. Outbreak detection was hampered by the absence of routine Salmonella surveillance in Japan. The investigation was complicated by concurrent illnesses from other SE phage types. It was successful, in part, because adequate food samples were available for microbiological testing.

Child↗

Effect of metal strengthener length on stress distribution in acrylic denture bases: a finite element study.

This study investigated the influence of metal strengthener length on stress created in acrylic denture bases in relation to location of the vertical support to the dentures. Finite element analysis was conducted to calculate stress generated in the straps of 2 mm-thickness and 18 mm-width that were reinforced with metal strengtheners of five different lengths. A vertical biting force of 60 N was directed on one end of each strap, while the other end was fixed. Vertical movements were restricted at one of the three support locations between the centre of the strap and the loading site. When the straps were vertically supported near the loading site, greater maximum tensile stresses were seen in the straps with relatively short strengtheners than those shown in the straps with longer strengtheners. The metal strengtheners with sufficient length may provide a preventive denture design against the acrylic fractures.

Acrylic Resins↗

Bone mineral density of the mandible in ovariectomized rats: analyses using dual energy X-ray absorptiometry and peripheral quantitative computed tomography.

INTRODUCTION: Although previous studies have shown that maxillary molar extraction in ovariectomized (OVX) animals causes mandibular loss of bone, it is still questionable as to whether estrogen deficiency affects mandibles with functional occlusion. MATERIALS AND METHODS: To answer this question, 13-week-old female Sprague-Dawley rats were bilaterally OVX or sham-operated. After 109 days, the bone mineral density (BMD) of the femurs and mandibles was measured using dual-energy X-ray absorptiometry (DEXA) and peripheral quantitative computed tomography (pQCT). RESULTS: In DEXA analysis, although the BMD of the total mandible of the OVX rats was similar to that of the sham-operated rats, the BMD of the condylar region in the OVX rats had decreased by 12.5%. In pQCT analysis, decrease in trabecular BMD of the mandibular bone was detectable but low in the molar region (maximal 13%), whereas no difference was seen in cortical BMD. In the femurs, the trabecular bone prominently decreased in OVX rats (30% decrease in pQCT analysis) as previously reported. CONCLUSION: This study revealed regional differences in the mandibular bone decrease in OVX rats. Although the mechanism of low susceptibility of the mandible to estrogen-deficient conditions remains unknown, it is likely that mechanical stress derived from functional occlusion is preventing bone loss in this pathological condition. Furthermore, this study demonstrated the advantage of pQCT in analyzing rat mandibular bone.

Absorptiometry, Photon↗

A new and simple method for evaluating masticatory function using newly developed artificial test food.

The aim of this study was to develop an objective evaluation system for the masticatory function. This system used paraffin wax cubes as a test food, which had six red- and green-coloured layers so that each of the six surfaces showed a pseudo-checkered pattern. A total of 100 paraffin cubes were chewed by 37 subjects and the images of these samples were captured and analysed using a digital image analyzer. With regard to the colour and the shape of each sample, five parameters were obtained. Furthermore, an independent examiner graded the degree of colour mixing in the chewed samples into three groups (poor, medium and good) by visual inspection. A discriminant analysis was performed using the five variables as predictors of two groups (good and poor). Mixing Ability Index (MAI) was calculated from the discriminant function and using this index, 97% of the samples from these two groups were classified correctly. This system needed only a few minutes to complete and is easy to use. Therefore, it has high potentials for clinical use.

Adult↗

Validity and reliability of a newly developed method for evaluating masticatory function using discriminant analysis.

The objective of the study was to assess validity and reliability of a newly developed method for evaluating mixing ability of masticatory function. A two-coloured paraffin wax cube was used as a test food in the mixing ability test. Eleven full dentate and 33 denture wearers participated in the validity assessment. They were divided into three groups according to their dental state. Validity was assessed by the Spearman's coefficient of correlations between the mixing ability test and the sieving method used as a 'gold standard' test of the masticatory performance. The subjects were asked to masticate the test foods for 5, 7, 10, 15, 20 and 30 strokes in each test. Significant correlations (P < 0.001) were obtained in natural dentition group (r(s) = 0.66), in denture-natural dentition group (r(s) = 0.72) and in denture-denture group (r(s) = 0.56). In the reliability assessment, three full dentate subjects were asked to repeat the mixing ability test a number of times. The intraclass correlation coefficients were 0.94 in interexaminer consistency, 0.98 in intra-examiner consistency, 0.89 in test-retest consistency and 0.99 in measuring consistency. These results indicated that the mixing ability test had the validity and the reliability for evaluation of the masticatory performance.

Adult↗

Influence of working side contacts on masticatory function for mandibular distal extension removable partial dentures.

The aim of this study was to clarify the influence of working side contacts for masticatory function for a distal extension removable partial denture. Five subjects who had edentulous arches from second premolar to second molar opposing natural teeth participated. Working side contacts were altered by using three types of artificial teeth attached to the denture base. A-form teeth made contact with opposite teeth while acting as the working side in a lateral excursion. The cusp angles of B- and C-form teeth were decreased by 10 degrees and 20 degrees, respectively compared with A-form teeth. B-and C-form teeth discluded with opposite teeth on the working side. Subjects were asked to perform two kinds of masticatory performance test. Obtained data were evaluated by the repeated-measures anova and the Tukey test for multiple comparisons. Results revealed that there was a significant difference (P=0.001) in the three types of teeth in the mixing ability test and the value of A-form teeth was statistically less value than those of the other teeth. However, there was no significant difference in the comminuting ability test. These results suggested that working side contacts between artificial teeth and opposite natural teeth influenced mixing ability, but not comminuting ability.

Adult↗

3-D Finite element analysis of all-ceramic posterior crowns.

The purpose of this study was to evaluate the stress distribution under various loading conditions within posterior all-ceramic crowns. A three-dimensional finite element model representing a lower first molar was constructed. Variations of the model had two types of single layer all-ceramic crowns (Dicor and Empress) and two types of double layer all-ceramic crowns (In-Ceram and Empress2) cemented. A load of 600 N, simulating the maximum bite force, was applied vertically to the crowns. Loads of 225 N, simulating masticatory force, were applied from three directions (vertically, at a 45 degrees angle, and horizontally). In the test simulating maximum bite force, the maximum tensile stresses on all crowns (17.4-19.4 MPa) concentrated around the loading points. In the masticatory force simulation test, the specimens experienced maximum tensile stresses of 19.7-27.0 MPa under a horizontal load and 10.8-10.9 MPa under a vertical load. When the load was applied horizontally, the maximum tensile stress was observed around the loading points on the surface in the case of the single layer crowns, and of the cervical area of the inner core of the double layer crowns. Within the limitation of this study, it was found that the strength of occlusal contact points is important to the integrity of posterior all-ceramic crowns and that bite forces applied from the horizontal direction are a critical factor.

Bite Force↗

Enhancement of osteogenesis on hydroxyapatite surface coated with synthetic peptide (EEEEEEEPRGDT) in vitro.

Some dental implants are coated with hydroxyapatite (HA), which preferentially binds to bone. Several matrix proteins have an arginine-glycine-aspartic acid (RGD) sequence where cells attach via an integrin receptor. We hypothesized that coating an HA surface with an RGD-containing peptide might enhance the attachment and differentiation of osteoblasts. The HA disks (diameter 34 mm, thickness 1 mm) were treated with a solution (50 mM Tris/HCl and 150 mM NaCl, pH 7.4) containing the peptide EEEEEEEPRGDT, in which the E repetition exerts a high affinity to HA. After washing with phosphate-buffered saline, KUSA/A1 mouse osteoblastic cells were inoculated onto the HA surface and cultured. After 30 min, the number of cells attached to the surface was counted. The DNA content and alkaline phosphatase (ALP) activity were measured after 10 days in culture. Expression of bone matrix proteins was also examined by means of reverse transcriptase-polymerase chain reaction at 7 days; the mineralized area of the culture was also evaluated by staining with Alizarin Red S after 10 days. Treatment with the peptide stimulated cell attachment and increased DNA content and ALP activity. Furthermore, matrix protein expression and mineralized nodule formation were enhanced to a greater extent on the peptide-treated surface than on the nontreated surface. Our results indicate that coating an HA surface with RGD-containing peptide enhances osteoblast attachment and differentiation. This peptide treatment of HA-coated implants may stimulate the osseointegration of the implants.

Animals↗

Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

Bioterrorism↗

Vibration analysis of maxillary removable partial denture frameworks.

The purpose of this study was to investigate the vibratory characteristics of three designs of the Class I Kennedy maxillary removable partial denture frameworks as the basic study. Their major connectors comprised a U-shaped palatal connector (UPC), single palatal bar (SPB), and anterior-posterior palatal bars (APB). Frequency response functions were measured when the framework was impacted. The modal shape was observed and the decay rate was calculated using modal analysis software. The results showed that the vibratory properties of each framework differed from each other. Within the range of frequencies from 10 to 2000 Hz, the UPC type had seven natural frequencies, while the SPB and the APB types had six. The UPC type had a greater number of natural modes accompanied by elastic deformation, including fluttering and twisting, than the other type, and the UPC type was considered to be unfavourable. The decay rate of the APB type was significantly higher than those of the UPC and the SPB types (P < 0.01).

Analysis of Variance↗

Digital acoustic analysis of five vowels in maxillectomy patients.

The aim of the study was to characterize the acoustics of vowel articulation in maxillectomy patients. Digital acoustic analysis of five vowels, /a/, /e/, /i/, /o/ and /u/, was performed on 12 male maxillectomy patients and 12 normal male individuals. A simple set of acoustic descriptions called the first and second formant frequencies, F1 and F2, were employed and calculated based on linear predictive coding. The maxillectomy patients had a significantly lower F2 for all five vowels and a significantly higher F1 for only /i/ vowel. From the data plotted on an F1-F2 plane in each subject, we determined the F1 range and the F2 range, which are the differences between the minimum and the maximum frequencies among the five vowels. The maxillectomy patients had a significantly narrower F2 range than the normal controls. In contrast, there was no significant difference in the F1 range. These results suggest that the maxillectomy patients had difficulty in controlling F2 properly. In addition, the speech intelligibility (SI) test was performed to verify the results of this new frequency range method. A high correlation between the F2 range and the score of SI test was demonstrated, suggesting that the F2 range is effective in evaluating the speech ability of maxillectomy patients.

Acoustics↗