PubMed Health⌕ Search

Biomedical subjects

T P Willems

Publications and source records attributed to T P Willems.

11 recordsLinked to original sources

The benefit of 64-MDCT prior to invasive coronary angiography in symptomatic post-CABG patients.

PURPOSE: The purpose of this study is to assess the diagnostic accuracy of 64-MDCT in symptomatic patients after CABG and to explore the advantages of the 64-MDCT results on the CAG procedure. MATERIAL AND METHODS: From December 2004 until August 2005, 34 post-CABG patients (29 men, mean age 63.5 +/- 8.5 years) with 69 coronary artery bypass grafts were scanned on a 64-MDCT (Somatom Sensation 64, Siemens AG, Forchheim, Germany) prior to CAG. Angiograms and 64-MDCT images were evaluated for the existence of occlusions or significant stenosis (>or=50% lumen reduction) in bypass grafts and native coronary arteries. RESULTS: 64-MDCT had a sensitivity, a specificity, and a diagnostic accuracy of 100% for occlusion detection. For stenosis detection, sensitivity was 100%, specificity 98.7% and diagnostic accuracy 98.7%. For detecting significant stenosis in native coronary arteries, 64-MDCT had a sensitivity of 80.0%, specificity of 90.8%, and a diagnostic accuracy of 87.1%. Seventeen patients (50.0%) did not need invasive treatment, 14 patients (41.2%) underwent a percutaneous coronary intervention (PCI), and 3 patients (8.8%) underwent surgery. Treatment advice based on 64-MDCT was correct in 88.2% of patients and when 64-MDCT results would have been known 58.8% of diagnostic CAG procedures could have been prevented. CONCLUSION: In conclusion, 64-MDCT has a high diagnostic accuracy in detecting bypass graft stenosis and occlusions, and 64-MDCT based treatment advice was correct in 88.2% of patients.

Aged↗

Quantification of global left ventricular function: comparison of multidetector computed tomography and magnetic resonance imaging. a meta-analysis and review of the current literature.

Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI.

Humans↗

A 16-slice multidetector computed tomography protocol for evaluation of the gastroepiploic artery grafts in patients after coronary artery bypass surgery.

Arterial coronary bypass grafts [internal mammary arteries and gastroepiploic artery (GEA)] are in widespread use for coronary surgery. Since selective catheterisation of the GEA graft to monitor patency, is often unsuccessful, a non-invasive protocol to visualise the GEA-graft from origin to anastomosis is presented using 16-slice multidetector computed tomography (MDCT). Twenty-six male patients (mean age 58.1+/-6.7 years) with GEA grafts were scanned according to a protocol of an ECG-synchronised cardiac scan followed by a thoracoabdominal scan. To terminate the scan at the correct anatomical level, the lowest level of the GEA was coded based on the lumbar vertebrae level. Scores ranging from one (excellent) to four (bad) were assigned to evaluate visualisation quality of the grafts. GEA grafts were assessable in 62% of the thoracoabdominal scans and 69% of the cardiac scans. On average, the lowest part of the GEA corresponded with a level between L1 and L2, in two cases in the upper part of L3. Mean visualisation score in the thoracoabdominal scans and cardiac scans was good (respectively 1.4+/-0.6 and 1.4+/-1.0). Sixteen-slice MDCT is a promising alternative for catheterisation in evaluating patency of GEA grafts, using the presented protocol with thoracoabdominal scan including L3 for complete coverage of the GEA graft.

Clinical Protocols↗

Multidetector computed tomography-guided treatment strategy in patients with non-ST elevation acute coronary syndromes: a pilot study.

Patients with non-ST elevation acute coronary syndrome (ACS) and evidence of myocardial ischaemia are scheduled for coronary angiography (CAG). In most patients CAG remains a single diagnostic procedure only. A prospective study was performed to evaluate whether 16-slice multidetector CT (MDCT) could predict treatment of the patients and to determine how many CAGs could have been prevented by MDCT scanning prior to CAG. Twenty-two patients with ACS were scanned prior to CAG. Based on MDCT data, a fictive treatment was proposed and compared to CAG-based treatment. Excellent accuracy was observed to detect significant stenoses using MDCT (sensitivity 94%, specificity 96%). In 45%, no PCI was performed during CAG, because of the absence of significant coronary artery disease (27%) or severe coronary artery disease, demanding CABG (18%). MDCT predicted correct treatment in 86%. By using MDCT data, 32% of the CAGs could have been prevented.

Acute Disease↗

Human tissue valves in aortic position: determinants of reoperation and valve regurgitation.

BACKGROUND: Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve regurgitation measured by serial echocardiography. METHODS AND RESULTS: In adult patients, 218 cryopreserved aortic allografts were implanted with the subcoronary (85) or the root replacement technique (133), and 81 patients had root replacement with a pulmonary autograft. Mean follow-up was 4.2 years (SD 2.7; range, 0 to 10.5). Patient age, operator experience with subcoronary implantation, and allograft diameter were independent predictors for reoperation. With repeated color Doppler echocardiography, the severity of aortic regurgitation was assessed by the jet length method and the jet diameter ratio. Multilevel hierarchical linear modeling was used to estimate initial aortic regurgitation (intercept), its change over time (slope), and the effect of 11 potential determinants of durability on aortic regurgitation. With the jet length method, the intercept was 0.94 grade and the slope was 0.11 grade per year. With the jet diameter ratio, the intercept was 0.34 and the annual increase was 0.01. Subcoronary implanted valves had more initial aortic regurgitation, but progression of aortic valve regurgitation did not differ from root replacement. At midterm follow-up, recipient age <40 years was the only independent predictor of aortic regurgitation. CONCLUSIONS: Subcoronary implantation has a learning curve, resulting in more initial aortic regurgitation and early reoperation compared with root replacement. In both techniques, progression of aortic regurgitation over time is small but accelerated in young adults.

Adolescent↗

Aortic allograft implantation techniques: pathomorphology and regurgitant jet patterns by Doppler echocardiographic studies.

BACKGROUND: The diagnosis of allograft-specific pathology by echocardiography has important consequences for patient counseling and research. This study describes the pathomorphologic findings and color Doppler jet patterns in a consecutive series of patients after allograft placement with either the subcoronary implantation or root replacement technique. METHODS: From 1987 to July 1996, the subcoronary allograft implantation technique and root replacement technique were used in 82 patients and 70 patients, respectively. These patients comprised the study group. RESULTS: The incidence of paravalvular leaks and eccentric regurgitant jets was higher with subcoronary implantation (41%) than with root replacement (11%). Patients with a subcoronary implanted allograft had a higher incidence of eccentric jets. CONCLUSIONS: These findings support the concept of preservation of valve geometry after root replacement, as allograft-specific pathomorphologic abnormalities and eccentric jets are more common after subcoronary implantation of allografts. Learning effects, however, cannot be excluded as the cause of these abnormalities.

Adolescent↗

Allograft reconstruction of the right ventricular outflow tract.

OBJECTIVE: Evaluation of allograft reconstruction of the right ventricular outflow tract (RVOT). METHODS: From 1986 to April 1995, 201 allografts (146 pulmonary, 55 aortic) were implanted in 189 patients for conduit reconstruction of the RVOT in congenital heart disease or in the pulmonary autograft procedure. The mean age at allograft implantation was 16 years (range 2 weeks - 54 years). The primary diagnoses of these patients were truncus arterious (n = 19, 10%), transposition of the great arteries (TGA) with ventricular septal defect (VSD) and pulmonary atresia (PA) or stenosis (PS) (n = 14, 7%), PA with VSD (n = 26, 14%), PA or PS with intact septum (n = 7, 4%), tetralogy of Fallot (n = 44, 23%), corrected TGA with PA or PS (n = 11, 6%), tricuspid atresia (n = 9, 5%), aortic valve pathology for pulmonary autograft procedure (n = 55, 29%), and miscellaneous (n = 4, 2%). The allograft implantation was a reoperation in 54 patients (29%). RESULTS: The mean follow-up was 2.5 years (range 4 weeks-9 years). Six patients died in hospital (3.2%). Patient survival at 5 years was 91% (95% CL 86-95%). Freedom from all valve-related events (2 deaths, 17 reoperations, one endocarditis), as determined during reoperation or autopsy at 5 years was 78% (95% CL 65-86%). Freedom from structural allograft failure was 83% (2 deaths, 12 reoperations, 95% CL 70-90%). Allografts implanted for congenital right heart defects failed earlier than allografts used for pulmonary autograft procedures (P = 0.05). Aortic allografts showed structural failure more often than pulmonary allografts (P = 0.05). There were more valve-related events in patients of a younger age at implantation (P = 0.02) and in those allograft valves from younger donors (P = 0.004). CONCLUSIONS: Allograft RVOT reconstruction is an adequate surgical therapy. The allograft should preferably be pulmonary. A younger age at implantation is a risk factor for allograft failure. Donor age may be a thus-far underestimated risk factor for allograft degeneration.

Adolescent↗

Subcoronary implantation or aortic root replacement for human tissue valves: sufficient data to prefer either technique?

The aortic root replacement technique with aortic allograft or pulmonary autograft might be superior to the subcoronary allograft implantation technique with regard to aortic regurgitation. We explored the influence of the learning process on the incidence of reoperation and the severity of postoperative aortic regurgitation as assessed by color Doppler echocardiography. The subcoronary implantation technique was used in 81 patients, and root replacement was done in 63 patients. The first 30 patients of each group were considered as the surgeons' learning curve. Reoperations were more common in the subcoronary implantation group. After exclusion of early reoperations, the median regurgitation score based on echocardiographic examination was 0.22 in the first 30 patients from the subcoronary implantation group and 0.14 in the root replacement group. The subsequent patients from these groups had regurgitation scores of 0.20 and 0.17, respectively. Statistical analysis of these data showed no significant difference. This interim report suggests that the learning curve for the surgical procedure and the grouping of echocardiographic data influence the interpretation of follow-up studies. The superiority of either technique with regard to aortic regurgitation has yet to be proved.

Adolescent↗

Aortic root replacement with a pulmonary autograft.

A series of 42 consecutive patients with exclusively aortic root replacement using the pulmonary autograft is presented. The mean age at operation was 19.3 years (range 0.3-41.4). Two patients died in hospital (4.8%; 70% CL: 0.0-8.2). This mortality was not related to the autograft procedure. The mean follow-up time was 30 months (range 3-70; SD: 20). Late mortality consisted of two patients; in one of these severe autograft failure occurred due to chronic juvenile rheumatoid arthritis. The estimated survival rate at 4 years was 88.8% (70% CL: 83.3-94.5). Morbidity involved three patients. One had a total heart block after operation, requiring pacemaker implantation and two patients were reoperated: one for severe autograft failure due to recurrent acute rheumatic fever and the other for severe stenosis at the distal anastomosis of the pulmonary allograft. Thromboembolic complications and endocarditis were not registered. Reoperations for technical or degenerative reasons were not necessary. The estimated event-free survival rate at 4 years was 78.7% (70% CL: 71.0-86.4). Serial echocardiography (n = 28) showed a significant increase of the autograft annulus diameter of 2.9 mm (SD: 2.7). Thirty-five of the 37 patients with an autograft in situ were in NYHA class I, and 2 in class II. At last follow-up precordial color Doppler echocardiography showed moderate aortic regurgitation in one patient and no, trivial or mild aortic regurgitation in 36 patients. Stenosis of the autograft was not observed. These medium-term results are promising with respect to mortality, morbidity and functional results.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Reproducibility of color Doppler flow quantification of aortic regurgitation.

The preferred method for quantification of aortic regurgitation severity with color Doppler echocardiography is the assessment of the ratio of jet diameter to left ventricular outflow tract diameter and jet area to left ventricular outflow tract area. However, the reproducibility of these measurements is not known and may limit its clinical application. This study was performed to identify sources of variability and reproducibility of the echocardiographic data. We examined 62 color Doppler echocardiographic examinations of patients showing isolated aortic regurgitation after human tissue valve implantation. The mean differences with standard deviations between paired measurements were calculated. The interobserver, intraobserver, and interframe variability showed a close agreement for the jet diameter and left ventricular outflow tract diameter measurements. The agreement for jet area and left ventricular outflow tract area measurements showed a small bias, but a large variance. The reproducibility of jet-left ventricular outflow tract diameter is better than the jet-left ventricular outflow tract area measurement and is more accurate to assess the severity of aortic regurgitation from color Doppler images.

Adult↗