PubMed Health⌕ Search

Biomedical subjects

T Pasierski

Publications and source records attributed to T Pasierski.

At least 19 recordsLinked to original sources

Risk factors for atherosclerosis in healthy employees-a multidisciplinary approach.

BACKGROUND: The aim of the study was to investigate the prevalence of early atherosclerosis in healthy workers and the relationship between classical, psychological, and immunological risk factors and atherosclerosis, as well as their predictive value. METHODS: One hundred healthy managers and 50 office workers aged 35-65 were studied. In all subjects, individual, family, and occupational stress/coping risk factors were evaluated, including plasma levels of biochemical (total cholesterol, LDL, HDL, TG, glucose) and inflammatory-immunological (aCL, anti-beta(2) GPI, oxLDL, HSP, HSCRP) parameters. Carotid artery intima-media thickness (IMT) and atherosclerotic plaques in carotid arteries were assessed with computer analysis of B-mode ultrasound images. RESULTS: In 107 persons (71%) no changes were found in ultrasound images and in 43 individuals (29%) the presence of plaque was shown. The mean IMT value was 0.0618+/-0.013 mm. Cross-domain analysis showed that core predictors for IMT were age, LDL level, smoking, and occupation (being a manager) (beta=0.33, 0.30, 0.23, and 0.20, respectively); the core predictors for plaque were age, total cholesterol level, and an occupational stressor home-work balance (Wald=7, 6.7, and 5.6, respectively). Immunological factors were not independent predictors. CONCLUSIONS: In atherosclerosis, not only traditional risk factors (age, lipid disorders, and lifestyle) but also occupational stress factors may play a role. Immunological factors do not seem to play a role in the development of atherosclerosis in a population of healthy workers. The interplay between occupational stress and atherosclerotic changes requires further investigation.

Journal Article↗

Advantages of exercise echocardiography in comparison to dobutamine echocardiography in the diagnosis of coronary artery disease in hypertensive subjects.

OBJECTIVE: The aim of the study was to compare the efficacy and safety of two stress echocardiography methods, exercise and dobutamine, in the diagnosis of coronary artery disease in hypertensive patients with angina. PATIENTS AND METHODS: A total of 197 treated hypertensive patients, age 53 +/- 9 years (65 women) with no history of myocardial infarction referred for coronary angiography were prospectively investigated with exercise electrocardiography (ECG), exercise and dobutamine echocardiography. RESULTS: Sensitivity of the exercise ECG, exercise echocardiography and dobutamine echocardiography did not differ (77%, 82% and 75%). Negative predictive value of exercise ECG was significantly lower than exercise echocardiography (64% vs 79%, P < 0.01). Specificity and positive predictive value of exercise ECG were markedly lower than exercise and dobutamine echocardiography (57%, 96%, 98% and 72%, 97%, 98%, P < 0.0001 for both stress echocardiography vs ECG). Specificity and sensitivity of diagnostic methods were not influenced by the presence of echocardiographic left ventricular hypertrophy. Dobutamine infusion in comparison to exercise was more often associated with substantial arterial blood pressure rise or fall (7% vs 2%, P < 0.05) and with simple ventricular ectopy (15,7% vs 6,1%, P < 0.05). CONCLUSIONS: In hypertensive patients with the symptoms of angina, both stress echo methods are significantly more specific than the exercise ECG test. Maximal exercise is associated with less frequent side effects than infusion of dobutamine, so exercise echocardiography may be preferred in the diagnosis of angina in hypertensive patients.

Adult↗

Transesophageal echocardiographic findings in patients with anterior and posterior circulation infarcts.

OBJECTIVES: The aim of this study was to assess the role of transesophageal echocardiography in detecting the source of cerebral embolism in ischemic stroke patients and to evaluate the difference in occurrence of heart abnormalities in anterior and posterior circulation infarcts. MATERIAL AND METHODS: The study group included 104 patients, 51 males and 53 females with ischemic stroke without significant atherosclerosis in the carotid arteries. Age of the patients ranged from 14 to 82 years (mean 55). The clinical picture of stroke suggested the embolic etiology, 34 of them had atrial fibrillation. Transthoracic and transesophageal echocardiography were performed in all patients. All patients were separated as anterior or posterior circulation infarcts. The control group consisted of 100 patients aged from 14 to 73 years (mean 53) without stroke history. RESULTS: Transesophageal echocardiography (TEE) examination revealed left atrial thrombus in 12%, left atrial spontaneous contrast in 16%, interatrial communication in 31%, mitral valve prolapse in 20%, atrial septal aneurysm in 14%, ventricular thrombus in 6% and aortic atheromas of 5 mm or more in size in 7% of stroke patients. In the control group left atrial spontaneous contrast was found in 10%, interatrial communication in 17%, mitral valve prolapse in 4%, atrial septal aneurysm in 8%, neither atrial nor ventricular thrombi were found. At least one abnormal TEE finding was present in 70 (67%) of stroke patients. Abnormal TEE findings were more often seen in patients with anterior circulation infarct than in those with posterior circulation infarcts, although the difference was not statistically significant. Left atrial thrombus and mitral valve prolapse occurred statistically significantly more often in stroke patients than in the control group. CONCLUSIONS: Echocardiographic examination is often abnormal in patients with ischemic stroke. The study did not reveal the statistically significant difference in the prevalence of abnormal transesophageal echocardiography findings between patients with anterior and posterior circulation infarcts.

Adolescent↗

Resolution of an aortic mobile mass with anticoagulation without evidence of arterial embolism.

The prognostic significance of aortic mobile debris detected by transesophageal echocardiography (TEE) in patients without history of embolism has not been established. A mobile aortic arch mass was found by TEE in a 59-year-old man with coronary artery disease, and with rheumatic mitral valve disease, and with no embolic symptoms. The patient was anticoagulated for 6 weeks and the mass was no longer seen on repeated TEE. He had no embolic symptoms during 9 months of follow-up. Different therapeutic approaches to mobile aortic debris are discussed and anticoagulant treatment of asymptomatic cases is advocated.

Anticoagulants↗

Surgery as an effective nonpharmacological mode of treatment of atrial fibrillation resistant to standard therapy.

There are two surgical methods for atrial fibrillation (AF) treatment: Maze and corridoring procedures. The first one prevents AF occurrence by performing multiple atriotomies. During the second procedure a corridor between a sino-atrial and the AV node is created together with an electrical isolation of the atria. During 1992 and 1993 seven patients, aged 27-55, mean 43-years-old, with recurrent, resistant to standard therapy AF were referred for surgical treatment to our department. Additional diagnoses include: concealed WPW syndrome in 1 patient, atrial septal defect (ASD) in 3 patients, coronary artery disease in 1 patient. Maze procedure was performed solely in 1 patient, in another together with 2 accessory pathways ablation, in 3 patients with ASD closure and in 1 patient with 2 bypass grafts. In one patient corridoring procedure was performed. Normal sinus rhythm was restored in every patient from 7 to 26 days after the procedure. No surgical complications were noted during the postoperative period. Mechanical function of the atria was documented with echo Doppler 2-6 weeks after the operation. No evidence for AF recurrence was noted within 3-14 months (mean 5 months) of follow-up. The preliminary results of Maze and corridoring procedures are encouraging.

Adult↗

A comparison between the automatized impedance cardiography and pulsed-wave Doppler echocardiography methods for measurements of stroke volume (SV) and systolic time intervals (STI).

Stroke volume (SV) and systolic time intervals (STI) were measured automatically using impedance cardiography signals (ICG) and compared with those obtained by pulsed-wave Doppler echocardiography using the apex approach. The comparison was made in 9 healthy male subjects, mean age 24.9 +/- 12.2 years, using recordings of 10 heart cycles simultaneously obtained by the two methods. During measurements the subjects rested in the supine position. There were no differences between mean values of SV determined by the two methods as well as between mean values of ejection time (ET) (p > 0.8 and p > 0.9, respectively). The pre-ejection period (PEP) estimated by ICG was 22 ms longer than that determined by echocardiography (p < 0.001). The relationship between SV values measured by impedance cardiography (SVA) vs those calculated by echocardiography (SVE) was found to be close to the line of identity in the range of measurements. The regression equation for SV was: SVA = 0.784.SVE + 15 (r = 0.69, p < 0.001, SEE = 10.7 ml). We conclude that automatic determination of SV and ET from ICG signals provides results comparable in absolute values with those obtained by the pulsed wave Doppler ultrasonocardiography using the apex approach for subjects remaining in the supine position.

Adult↗

[Primary arterial hypertension. Treatment with captopril and function of the left heart ventricle, concentration of catecholamine in blood and activity of renin].

We evaluated the effect of captopril treatment on left ventricular mass (LVM) and function in sustained mild-to-moderate primary hypertension. In 16 men aged 34.5 +/- 6.4 yrs. M-mode echo and pulsed wave Doppler recordings were obtained prior to and after 2 months captopril treatment (50-150 mg daily). No significant changes in heart rate, systolic blood pressure, ejection fraction, fractional shortening, cardiac output, LVM and Doppler-derived indices of mitral inflow were observed. Diastolic blood pressure measured during examination fell from 102.2 +/- 13.3 to 90.3 +/- 9 mmHg (p less than 0.026). No consistent correlations between catecholamines and indexes of left ventricular function were found. Two-month captopril therapy in mild-to-moderate hypertension results in diastolic blood pressure lowering with no effect on LVM or left ventricular function.

Adult↗

Factors influencing transmitral flow velocity in normal and hypertensive subjects.

Transmitral flow velocity and its determinants were examined with Doppler echocardiography in 53 hypertensive and 32 age-matched healthy normotensive men. Early and late maximal transmitral velocity, and early and late flow velocity integral were evaluated. In comparison with normal subjects, hypertensive patients were characterized by decreased maximal early velocity (66.3 +/- 12.3 versus 72.3 +/- 11.5 cm/sec, p less than 0.05), normalized early flow integral (67 +/- 7% versus 73 +/- 5%, p less than 0.001), increased maximal late flow velocity (45 +/- 10 cm/sec, p less than 0.001), and normalized late flow integral (29 +/- 7% versus 21 +/- 5%, p less than 0.001). Abnormally high late transmitral flow was found in 47% of the hypertensive group. Multiple regression analysis revealed that in normal subjects transmitral flow indexes were determined by age, relative wall thickness, and systolic blood pressure, but not by heart rate. A strong relationship of Doppler transmitral flow indexes with age was confirmed in hypertensive patients; however, relative wall thickness influenced transmitral flow velocity only weakly and systolic blood pressure did not affect transmitral flow. Left ventricular mass and diastolic blood pressure did not influence mitral filling velocity in either group. The altered pattern of mitral inflow found in a large number of hypertensive subjects is not related to elevated arterial blood pressure or to altered left ventricular geometry.

Adult↗

Pathophysiology of isolated systolic hypertension in elderly patients: Doppler echocardiographic insights.

Systemic hemodynamics were evaluated with aortic pulsed wave Doppler echocardiography in 79 elderly subjects with isolated systolic hypertension participating in the Systolic Hypertension in the Elderly Program (SHEP) and were compared with the values in 39 normal age-matched subjects. Cardiac output was elevated (4.50 +/- 1.13 L/min versus 3.94 +/- 1.12 L/min, p less than 0.05) in patients with isolated systolic hypertension in comparison with values in normal elderly subjects. Systemic vascular resistance did not differ between both groups (2140 +/- 536 dyn.sec/cm-5 versus 2011 +/- 553 dyn.sec/cm-5, p = NS). The mean acceleration of blood during left ventricular ejection was similar in patients with isolated systolic hypertension in comparison with normals (12.6 +/- 5.6 m/sec2 versus 11.5 +/- 3.5 m/sec2, p = NS). Patients with isolated systolic hypertension had significantly decreased arterial compliance, as measured by the stroke volume-to-pulse pressure ratio (0.77 +/- 0.26 cm3/mm Hg versus 1.11 +/- 0.30 cm3/mm Hg, p less than 0.0001). The prevalence of aortic and mitral regurgitation as well as valvular and annular calcification did not differ between analyzed groups. Isolated systolic hypertension in elderly patients appears to be multifactorial, with reduced arterial compliance and increased cardiac output both playing a role.

Aged↗

Initial clinical experience with a 48 by 48 element biplane transesophageal probe.

Recent technologic advances in ultrasound have resulted in the capability of transesophageal echocardiographic imaging in both transverse and longitudinal planes. Previous biplane probes suffered from inferior images because of reduced scan elements. We evaluated the utility of a prototype 48 X 48 element biplane transesophageal probe in 23 consecutive patients. Examinations were well tolerated with no side effects. In comparison to the single transverse plane, imaging with the longitudinal plane gave superior information on prosthetic valve pathology, atrial septal abnormalities, and pathoanatomy of the ascending aorta and mitral valve. Complementary information was provided by the longitudinal plane in patients with endocarditis and vegetations and in mitral protheses. Images obtained with this 48 X 48 element biplane probe along with color and spectral Doppler information were not perceptibly inferior to those obtained by single-plane probes. In conclusion, biplane transesophageal echocardiography with a 48 X 48 element probe indicates a great potential for enhanced three-dimensional understanding of cardiac pathology and diagnostic yield in specific pathologies.

Echocardiography↗

[Treatment of primary pulmonary hypertension with high doses of nifedipine controlled by Doppler echocardiography].

In a 22 year old female with primary pulmonary hypertension Doppler echocardiography revealed a systolic gradient between the right atrium and ventricle of 11.3 kPa (85 mmHg). A trial of high dose nifedipine therapy was started. It's efficacy was assessed by monitoring the tricuspid gradient. During therapy variations of the gradient were seen but without a favorable, steady, decrease trend. Although nifedipine did not produce any improvement during the "acute trial"--nifedipine therapy was continued--initially 60 mg, followed by 80 mg and finally 100 mg per day. Efficacy of this therapy was also controlled by Doppler echocardiography. Nifedipine was discontinued after 8 months due to lack of improvement in the patient's state. The patient died 30 months from the initial symptoms. Pathomorphological examination confirmed the clinical diagnosis. The use of Doppler echocardiography in assessing the vasodilators in primary pulmonary hypertension is discussed.

Administration, Oral↗

[Adaptation of the left ventricle to increased load in primary arterial hypertension].

Adaptational mechanisms of the left ventricle to increased afterload in essential hypertension were studied in a group of 53 males with essential hypertension and in 32 normotensive males of the control group. M-mode echocardiograms were performed in all patients. The degree of hypertrophy, contractility, end-systolic stress index were assessed. The group with essential hypertension had increased peripheral vascular resistance and normal LV out put. In this group there was also increase of LV contractility. Increased LV contractility and LV hypertrophy are adaptational mechanisms maintaining normal cardiac output in patients with hypertension through a decrease in end-systolic stress.

Adaptation, Physiological↗

Attempts at measuring pulmonary arterial pressure by means of Doppler echocardiography in patients with chronic lung disease.

In 72 patients with severe chronic pulmonary or pulmonary vascular disease pulmonary arterial pressure was measured by means of right heart catheterization. Forty three patients had pulmonary hypertension, (32 +/- 11 mmHg) and 27 patients had normal pressure (14 +/- 3 mmHg). These patients were examined with continuous wave (CW) and pulsed wave (PW) Doppler echocardiography. The retrograde systolic tricuspid valve pressure gradient assessed with CW Doppler correlated with systolic pulmonary pressure (r = 0.92, p less than 0.001, SEE 7.7 mmHg) but was measurable in only 17 of the 70 patients. The flow velocity pattern in the right ventricular outflow tract could be recorded in 68 of the 70 patients. Acceleration time (AcT) from systolic flow onset to peak velocity correlated with mean pulmonary artery pressure (r = 0.72, p less than 0.001, SEE 8.3 mmHg). An AcT less than 90 msec had an 84% positive predictive value for pulmonary hypertension. Right ventricular isovolumic relaxation time could be measured in 59 of the 70 patients and correlated with systolic pulmonary artery pressure (r = 0.69, p less than 0.001, SEE 12.4 mmHg). No single Doppler method is at the same time easily applicable and accurate in prediction of pulmonary arterial pressure in patients with chronic lung diseases.

Cardiac Catheterization↗

Aortic root abscess--echocardiographic image.

Autopsy findings point to a high prevalence of perivalvular abscesses in patients with infective endocarditis. Diagnosis of this complication, which may have therapeutical implications, is difficult. The authors present echocardiographic image obtained in a patient with bacterial endocarditis in whom an aortic root abscess was subsequently found at operation.

Abscess↗