PubMed Health⌕ Search

Biomedical subjects

T Rauch

Publications and source records attributed to T Rauch.

24 records · Page 2Linked to original sources

An experimental approach to quantitative thermal coronary angiography.

Thermal coronary angiography is a noninvasive but not yet quantitative method to intraoperatively assess graft patency in CABG surgery. Aim of this study was to quantify graft flow by measuring perfusion-induced myocardial temperature changes over time. Saphenous vein grafts to the left anterior descending artery were perfused at flow rates of 16-105 ml/min with warm saline. A thermal scanner with a 256 x 256 focal-plane array detector providing a spatial resolution of 1.2 mrad was used. The resulting temperature curves were averaged and a non-linear fit procedure was performed to calculate the time constant (tau) at each flow rate. An increase of myocardial temperature along the LAD with different flow rates could be demonstrated. There was an excellent correlation between the calculated time constant and actual flow (r = 0.96, p < 0.0002). By determining the time constant for different flow rates an estimate of actual graft flow is possible using thermal coronary angiography. Clinical studies have to show if the time constant can be used as a predictor of graft flow in patients.

Animals↗

Changes of leukocyte subsets in coronary artery bypass surgery: cardiopulmonary bypass versus 'off-pump' techniques.

BACKGROUND: The use of cardiopulmonary bypass (CPB) in coronary bypass grafting is associated with a generalized inflammatory response. This negative impact of CPB may be avoided by using new surgical techniques recently introduced to perform coronary bypass grafting 'off-pump', i.e. without CPB. METHODS: Since the specific effects of CPB on the immunorelevant cells have still not been fully investigated, we measured the changes in leukocyte subsets of the circulating blood in patients who underwent coronary bypass surgery with a conventional sternotomy approach and CPB (group A, n = 10), in patients who underwent the same surgical procedure but without CPB (group B, n = 10), and in patients who underwent a minimally invasively performed single bypass to the left anterior descending artery (LAD) (group C, n = 10). RESULTS: Leukocyte subsets showed a similar change during and after coronary bypass grafting in all three groups. The total number of leukocytes was increased soon after reperfusion in the CPB group. A similar but delayed increase was observed in both off-pump groups. Changes in lymphocyte subsets and T-lymphocyte subsets were similar in all three groups, with a drop of lymphocytes during the first 24 postoperative hours mainly caused by a drop of T4-helper cells. CONCLUSION: The results indicate a reaction of the leukocyte subsets to coronary bypass surgery which is more related to the surgical trauma in general than to CPB in particular.

Aged↗

Discrepancy of sizers for conventional and stentless aortic valve implants.

BACKGROUND AND AIM OF THE STUDY: As the hemodynamic performance of an artificial heart valve is closely related to the size of the valve implanted, exact sizing of the prosthesis is important in aortic valve replacement. In the past, discrepancies have been recognized between the actual and labeled diameters of sizers used for conventional aortic valves; this study aimed to examine the accuracy of sizers for both conventional and stentless valves. METHODS: Currently used sets of sizers were analyzed using a high-precision digital micrometer with a resolution of 0.01 mm. Sizers of aortic bileaflet mechanical valves (ATS, CarboMedics, St. Jude Medical Standard, St. Jude Medical HP), conventional aortic bioprostheses (Carpentier Edwards) and stentless aortic bioprostheses (Freestyle, TorontoSPV) were analyzed. The diameters were recorded when the sizer could not be moved laterally while still able to be rotated. RESULTS: Results are given as mean +/- standard deviation for 20 repeat measurements. All mechanical valve sizers were 0.77 +/- 0.03 to 1.01 +/- 0.02 mm larger than labeled, whereas all bioprosthetic valve sizers proved to be sized as labeled (0 +/- 0.01 mm). CONCLUSIONS: Exact sizing is important in stentless valve replacement. The use of accurate sizers is recommended with other types of replacement valves as well. Results of valve replacement procedures worldwide would be more comparable if sizers of identical size were available in all operating rooms. As long as discrepancies between different sizers still exist, surgeons must be made aware of the problem.

Aortic Valve↗

Analysis of the complete nucleotide sequences of goose and muscovy duck parvoviruses indicates common ancestral origin with adeno-associated virus 2.

The complete nucleotide sequences of two parvoviruses isolated from goose and muscovy duck were determined. The two virus genomes share 81.9% nucleotide sequence identity, indicating that they are closely related. The coding regions are bracketed by inverted terminal repeats containing palindromes. This is similar to the genome organization of human parvoviruses, adeno-associated virus 2, and B19. Amino acid sequence comparison shows that the closest relative of the goose and muscovy duck parvoviruses is adeno-associated virus 2. This is surprising, because the goose and muscovy duck parvoviruses do not require any helper virus for productive replication, suggesting that adeno-associated virus 2 has been derived from a helper-independent ancestor.

Amino Acid Sequence↗

Identification of a nuclear factor-I family protein-binding site in the silencer region of the cartilage matrix protein gene.

Cartilage matrix protein (CMP) is synthesized by chondrocytes in a developmentally regulated manner. Here we have dissected promoter upstream elements involved in its transcriptional regulation. We show that although the 79-base pair CMP minimal promoter is promiscuous, 1137 base pairs of 5'-flanking region are capable of directing tissue- and developmental stage-specific transcription when fused to a reporter gene. This results from two positive control regions which, in proliferating chondrocytes, relieve the repression mediated by two non-tissue-specific negative control regions. Characterization of the promoter proximal silencer by DNase I footprinting and gel shifts revealed the presence of two elements, SI and SII, which bound mesenchymal cell proteins. Methylation interference analysis indicated a gapped palindromic binding site similar to nuclear factor I (NF-I) family proteins within SI, but only a half-site within SII. Gel shift assays with specific NF-I and mutated SI competitors, binding of recombinant NF-I, as well as supershift analysis with NF-I-specific antiserum verified the binding of NF-I family proteins to the SI element. Double-stranded SI and SII oligonucleotides inserted in single copy in either orientation were found to repress both homologous and heterologous promoters upon transfection into mesenchymal cells. Transcriptional repression also occurred when a consensus NF-I site itself was fused to the CMP minimal promoter. We conclude that NF-I-related protein(s) can mediate transcriptional repression in cells of mesenchymal origin.

Animals↗

Experimental aortic stenosis and corresponding left ventricular hypertrophy in sheep.

Left ventricular hypertrophy (LVH) is an independent cardiac risk factor. A simple standard experimental model of inducing LVH for further studies using experimental aortic stenosis in sheep was performed. The aim of this study is to describe animal-specific requirements as well as perioperative therapy, postoperative care, and the use of echocardiography for routine follow-up examinations. Supracoronary aortic banding was performed in 55 female sheep at an age of 6 to 8 months. General anesthesia and an antero-lateral thoracotomy were used. The objective was to achieve pressure gradients of 20 to 30 mm Hg. In addition a 4th intercostal space rib window was created to improve echocardiographic vision. The operations were completed successfully in all animals. Intraoperatively, little severe arrhythmia occurred. During the follow-up interval of 8 +/- 1.3 months, 8 animals died, due to incomplete perforation of the ascending aorta (3), chronic heart failure (2), pericardial cyst (1), and respiratory failure and infection (2). All remaining animals were amenable for further studies. Severe LVH was diagnosed with routine echocardiography on follow-up. Thus, experimental aortic stenosis in sheep is a safe and relatively simple technique to generate stable LVH. Echocardiography is an easy tool for follow-up evaluations. Due to low complication rates, the sheep model is well suited for further research in LVH.

Animals↗