PubMed Health⌕ Search

Biomedical subjects

T Rockall

Publications and source records attributed to T Rockall.

11 recordsLinked to original sources

Robot-assisted laparoscopic Heller cardiomyotomy: preliminary UK results.

BACKGROUND/AIM: Laparoscopic Heller cardiomyotomy is an established modality in the surgical treatment of patients having achalasia cardia. We present our initial experience in robot-assisted laparoscopic Heller cardiomyotomy without addition of an antireflux procedure and discuss the relative merits and disadvantages of the procedure. PATIENTS AND METHODS: Five patients underwent robot-assisted laparoscopic Heller cardiomyotomy between August 2001 and October 2002. The diagnosis had been confirmed by radiology and manometry in all patients prior to surgery. RESULTS: All procedures were completed successfully using the robotic system, without conversion to open procedure. Mucosal perforation occurred in 1 patient and was sutured robotically. The average operative time was 114.8 (range 65-160) min which is comparable to laparoscopic procedures. After a mean follow-up period of 9.4 (range 3-17) months, 4 patients remained completely asymptomatic, and 1 patient has benefited from symptomatic improvement. CONCLUSIONS: The enhanced dexterity and the high-quality three-dimensional vision available with robot-assisted surgery make the application of this technology highly suitable for Heller cardiomyotomy. The minimal lateral and posterior dissection due to the wristed instruments avoids the need for an antireflux procedure.

Adult↗

An innovative method for the assessment of skills in lower gastrointestinal endoscopy.

BACKGROUND: Although virtual reality (VR) simulators can be used ability to objectively assess skills in endoscopy, the evaluation is solely quantitative. We have developed a novel method for the objective assessment of technical skills in lower gastrointestinal (GI) endoscopy that incorporates qualitative as well as quantitative measures. METHODS: We developed a virtual endoscopy suite by deconstructing the VR simulator to enable a more realistic and ergonomic placement of the monitor. Trainee endoscopists with varying levels of experience performed the case 4 task of the simulator. Ten essential components of endoscopic performance were rated on a five-point Likert scale (global score) by three independent observers. These observers viewed two videos (one showing scope handling and the other showing the monitor image), which were synchronized and played simultaneously. RESULTS: The study population comprised six experts (group 1, > 200 procedures), seven subjects with intermediate experience (group 2, 20-80 procedures), and seven novices (group 3, 1-10 procedures). The global score was found to discriminate the level of skills across all three groups (p < 0.001). There were significant differences between groups 1 and 2 (p = 0.003) and groups 2 and 3 (p = 0.004). There was a significant correlation between the global score and the percentage of red-out (without vision) as recorded by the simulator (correlation coefficients = -0.61, p = 0.004). CONCLUSION: This novel method for the assessment of technical skills in lower GI endoscopy has construct validity and high interrater reliability.

Clinical Competence↗

Robotics in colorectal surgery.

Minimally invasive surgery has been shown to offer many advantages to general surgical patients but has not been widely adopted for colorectal disease. Initial fears surrounding the oncological safety of laparoscopic colectomies have largely subsided but the technical challenges still remain. Surgical robots or telemanipulators present the laparoscopic surgeon with unrivaled dexterity and vision, which may allow colonic resections to be completed with greater ease. Although initial studies suggest promising results using currently available systems, it will take further time for patient benefits to be proven, therefore justifying the greater expense of operating with this new technology.

Colonic Diseases↗

Dexterity enhancement with robotic surgery.

BACKGROUND: The aim of this study was to quantify the extent of dexterity enhancement in robotic surgery as compared to laparoscopic surgery. METHODS: Ten surgeons with varying laparoscopic suturing experience were asked to place three sutures on a suture pad. The sutures were placed laparoscopically, robotically with 2-D vision and robotically with 3-D vision. The da Vinci systems Application Programming Interface (API) was used for positional data. A validated motion analysis system was used for data retrieval for the laparoscopic task. Custom software was developed for data analysis. RESULTS: Compared to laparoscopic suturing, when the task was undertaken robotically with 2-D vision there was a 20% reduction in the time taken but this was not significant (p = 0.07). There was a 55% reduction in the path traveled by the right hand (p = 0.01) and a 45% reduction in the path traveled by the left hand (p = 0.008). When the task was undertaken robotically with 3-D vision, there was a 40% reduction in the time taken (p = 0.01). There was a 70% reduction in the path traveled by right hand (p = 0.008) and a 55% reduction by the left hand (p = 0.08). CONCLUSIONS: The presence of wristed instrumentation, tremor abolition, and motion scaling enhance dexterity by nearly 50% as compared to laparoscopic surgery. 3-D vision enhances dexterity by a further 10-15%. In addition, the presence of 3-D vision results in a 93% reduction in skills-based errors.

Clinical Competence↗

The benefits of stereoscopic vision in robotic-assisted performance on bench models.

BACKGROUND: Previous studies have failed to establish clear advantages for the use of stereoscopic visualization systems in minimal-access surgery. The aim of this study was to objectively assess whether stereoscopic visualization improves performance on bench models using the da Vinci robotic system. METHODS: Eleven surgeons carried out a series of four tasks. Positional data streamed from the da Vinci system was analyzed by means of a previously validated custom-designed software-package. An independent blinded observer scored errors. Statistical analysis included the Wilcoxon signed rank test. A p < 0.05 was deemed significant. RESULTS: We found significant improvements in all tasks and for all parameters (p < 0.05). In addition, a significantly lower number of errors was scored using the stereoscopic mode as compared to the standard two-dimensional image (p < 0.001). CONCLUSION: Robotic-assisted performance on bench models is more efficient and accurate using stereoscopic visualization.

Data Display↗

Qualitative and quantitative analysis of the learning curve of a simulated surgical task on the da Vinci system.

BACKGROUND: Robotic telemanipulation systems provide solutions to the problems of less dexterity and visual constraints of minimally invasive surgery (MIS). However, their influence over surgeons' dexterity and learning curve needs to be assessed. We present motion analysis as an objective method to measure performance and learning progress.METHODS. Thirteen surgeons completed five synthetic small bowel anastomoses using the da Vinci system. Objective Structured Assessment of Technical Skills (OSATS) allowed qualitative analysis. Quantitative analysis used API software of the system to retrieve real-time robotic signal data of time, path length, and number of movements. Wilcoxon signed ranks test was used for statistical analysis. A p value <0.05 was considered significant.RESULTS. OSATS global scores were 18.6 points for the first attempt and 26 for the fifth attempt ( p < 0.02, Cronbach's alpha = 0.894). Paired data of motion analysis for attempts 1 vs 5 showed significant change: time taken 3507 sec and 2287 sec ( p < 0.008), total number of movements 2411 and 1387 ( p = 0.01), total path length 21,630 cm and 13,941 cm ( p = 0.01).CONCLUSIONS. A rapid learning curve to a competent level using the da Vinci system is possible aided by the system's intuitive motion. Motion analysis is a useful tool to measure performance in the da Vinci system compared to OSATS and time alone.

Anastomosis, Surgical↗

Robot-assisted laparoscopic adrenalectomy: preliminary UK results.

OBJECTIVE: To describe the results of our first two cases of laparoscopic adrenalectomy using the da Vinci surgical system (Intuitive Surgical, Inc., Mountain View, CA, USA). PATIENTS AND METHODS: Amongst 75 robot-assisted procedures performed at our institution, two patients underwent robot-assisted laparoscopic adrenalectomy. The set-up time, procedure time, hospital stay, complications and outcomes were recorded. RESULTS: Both operations were completed successfully using the robot; the mean (range) set-up time was 31 (25-37) min and mean procedure time 118.5 (107-130) min. One patient had a postoperative pulmonary embolus and was discharged 5 days after surgery; the second patient was discharged after 3 days. There were no intraoperative complications; both patients were well at the 1-year follow-up. CONCLUSIONS: Robot-assisted laparoscopic adrenalectomy is technically feasible and can be conducted efficiently and safely with the da Vinci surgical system.

Adenoma↗

Abdominal tuberculosis: the problem of diagnostic delay.

Abdominal tuberculosis can be difficult to diagnose. In order to minimize diagnostic delay, an audit study showed that the Mantoux test and/or culture of ascitic fluid did not reveal tuberculosis immediately. Laparoscopy/laparotomy with Ziel-Nielson staining and culture of tissue biopsy always confirmed the diagnosis. It is suggested that biopsy should be the first line in investigating patients suspected of having abdominal tuberculosis.

Adult↗