T Rockwell Mackie

Publications and source records attributed to T Rockwell Mackie.

5 recordsLinked to original sources

Confirmation, refinement, and extension of a study in intrafraction motion interplay with sliding jaw motion.

The interplay between a constant scan speed and intrafraction oscillatory motion produces interesting fluence intensity modulations along the axis of motion that are sensitive to the motion function, as originally shown in a classic paper by Yu et al. [Phys. Med. Biol. 43, 91-104 (1998)]. The fluence intensity profiles are explored in this note for an intuitive understanding, then compared with Yu et al., and finally further explored for the effects of low scan speed and random components of both intrafraction and interfraction motion. At slow scan speeds typical of helical tomotherapy, these fluence intensity modulations are only a few percent. With the addition of only a small amount of cycle-to-cycle randomness in frequency and amplitude, the fluence intensity profiles change dramatically. It is further shown that after a typical 30-fraction treatment, the sensitivities displayed in the single fraction fluence intensity profiles greatly diminish.

Body Burden↗

Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are usually based on the surface matching of the organ in two images. Such a surface matching, however, is hard to obtain from medical images. In this study, we developed a new boundary condition to circumvent the traditional difficulties. Finite element contact-impact analysis was employed to simulate the interaction between the organ of interest and the surrounding body. The displacement loading is not necessarily specified. The algorithm automatically deforms the organ model into the minimum internal energy state. The analysis was performed on CT images of the lung at two different breathing phases (exhalation and full inhalation). The result gave the displacement vector map inside the lung. Validation of the result showed satisfactory agreement in most parts of the lung. This approach is simple, operator independent and may provide improved accuracy of the prediction of organ deformation.

Algorithms↗

Plastic scintillation dosimetry: optimization of light collection efficiency.

Practical contemporary radiotherapy dosimetry systems used for dose measurement and verification are ionization chambers (which typically have at least a 0.1 cm3 air cavity volume), thermoluminescent dosimeters (TLDs) and silicon diodes. However, during the last decade, there has been an increased interest in scintillation dosimetry using small water-equivalent plastic scintillators, due to their favourable characteristics when compared with other more commonly used detector systems. Although plastic scintillators have been shown to have many desirable dosimetric properties, as yet there is no successful commercial detector system of this type available for routine clinical use in radiation oncology. The objectives of this study are to identify the factors preventing this new technology from realizing its full potential in commercial applications. A definition of signal to noise ratio (S/N) will be proposed for this category of detectors. In doing so the S/N ratio for an early prototype design has been calculated and/or measured. Criteria to optimize the response and sensitivity of this category of detectors are presented.

Cobalt Isotopes↗

Helical tomotherapy: an innovative technology and approach to radiation therapy.

Helical tomotherapy represents both a novel radiation treatment device and an innovative means of delivering radiotherapy. The helical tomotherapy unit itself is essentially a hybrid between a linear accelerator and a helical CT scanner for the purpose of delivering intensity-modulated radiation therapy (IMRT). The imaging capacity conferred by the CT component allows targeted regions to be visualized prior to, during, and immediately after each treatment. The megavoltage CT (MVCT) images supplant the port-films used in conventional radiotherapy, providing unprecedented anatomical detail. Image-guidance through MVCT will allow the development and refinement of the concept of "adaptive radiotherapy", the reconstruction of the actual daily delivered dose (as opposed to planned dose) accompanied by prescription and delivery adjustments when appropriate. In addition to this unique feature, helical tomotherapy appears capable of further improvements over 3-dimensional conformal radiation therapy and non-helical IMRT in the specific avoidance of critical normal structures, i.e "conformal avoidance", the counterpart of conformal radiation therapy. Based on radiobiological principles that exploit the physical advantages of helical tomotherapy, several dosimetric and clinical investigations are underway.

Combined Modality Therapy↗

PET/CT following intensity-modulated radiation therapy for primary lung tumor in a dog.

A primary lung tumor in a dog treated with intensity-modulated radiation therapy was imaged approximately 6 weeks and 1-year posttreatment with combined positron emission tomography (PET) and computed tomography, utilizing the radiotracers 18F-fluorodeoxyglucose and 18F-fluorothymidine. These two tracers allowed discrimination of tumor from inflammation, and demonstrated spread of tumor along airways over time after treatment. Fusion of functional imaging with anatomic imaging is a useful tool, particularly in the field of oncology, with the potential for PET markers that delineate tumor from normal or reactive tissue, and potential or actual response to therapy.

Animals↗