PubMed HealthSearch

Biomedical subjects

T Ryan

Publications and source records attributed to T Ryan.

At least 19 recordsLinked to original sources

Exercise echocardiography.

Exercise echocardiography is a versatile, noninvasive diagnostic test that involves the recording and interpretation of 2-dimensional echocardiograms prior to, during, and after exercise. By analyzing and comparing wall motion at each stage, a prediction about the presence or absence of coronary artery disease can be made. The development of a wall motion abnormality is both sensitive and specific for the presence of a significant coronary stenosis. Changes in regional systolic function during exercise enable the clinician to distinguish between infarction and ischemia. Thus, the test yields information on the presence, extent, severity, and location of coronary artery disease. Echocardiography can be adapted to almost any form of stress, although treadmill or bicycle exercise are most commonly employed. An advantage of bicycle stress echocardiography is the opportunity to image during exercise, rather than relying on postexercise recording. This contributes to enhanced sensitivity, although false-positive results may increase due to the difficulties of analyzing wall motion during strenuous exercise. Exercise echocardiography increases the diagnostic accuracy of stress testing in a manner similar to radionuclide perfusion imaging. It is particularly useful in the setting of an ambiguous stress electrocardiography (ECG) or when a false-negative or false-positive result is suspected. It has been successfully applied to patients following revascularization and yields useful prognostic data in a variety of clinical situations. Exercise echocardiography is being increasingly utilized as a safe and accurate test in patients with known or suspected coronary artery disease.

Coronary Disease

Dobutamine stress echocardiography: correlation with coronary lesion severity as determined by quantitative angiography.

This study was performed 1) to determine the ability of dobutamine stress echocardiography to detect stenoses in individual coronary arteries by utilizing a new model of coronary artery distribution; 2) to evaluate its ability to detect coronary artery stenosis with a minimal lumen diameter less than 1 mm; and 3) to correlate the heart rate at which a positive test result occurs with the severity of coronary artery disease. Eighty-five patients were identified who underwent both dobutamine stress echocardiography and quantitative coronary angiography. During incremental infusion of dobutamine, two-dimensional echocardiograms were obtained at rest, during low and peak stress and after stress. Echocardiograms were interpreted with use of a modified 16-segment model with an anteroinferior overlap scheme. The overall sensitivity of the technique for the detection of significant coronary artery disease (diameter stenosis greater than or equal to 50%) was 95%; specificity was 82% and accuracy 92%. The sensitivity for detection of individual coronary artery lesions did not differ significantly (p greater than 0.05) in the three major coronary artery distributions (79% left anterior descending, 70% left circumflex, 77% right coronary artery). Among 35 stenoses with a minimal lumen diameter less than 1 mm, the test result was positive in 30 (86%). Test results were correctly positive for 88%, 82% and 86% of stenoses in the left anterior descending, left circumflex and right coronary artery distributions, respectively. Multivessel disease was present in 11 of 16 patients with normal wall motion at rest who developed a wall motion abnormality at a heart rate less than 125 beats/min. The incidence of multivessel disease was statistically higher in patients with positive findings on a dobutamine stress echocardiogram at a heart rate less than or equal to 125/min. In conclusion, dobutamine stress echocardiography has high sensitivity and specificity for the detection and localization of coronary artery disease. Detection of stenosis in individual coronary arteries is improved in those lesions with a minimal lumen diameter less than 1 mm. Patients with a positive test result at a heart rate less than or equal to 125 beats/min have a high likelihood of multivessel coronary artery disease.

Adult

Distinguishing ischemic cardiomyopathy from nonischemic dilated cardiomyopathy with coronary echocardiography.

Transthoracic echocardiographic examination of the proximal left coronary system was performed in 59 patients who had dilated cardiomyopathy to determine if this technique could distinguish between ischemic and nonischemic dilated cardiomyopathy. With use of annular array transducers (3.5 or 5 MHz) and digital image processing, echocardiographic visualization of the coronary arteries was successful in 55 (93%) of 59 patients. As assessed by coronary angiography, 32 subjects had ischemic cardiomyopathy and 27 had nonischemic cardiomyopathy. Twenty-seven (84%) of the 32 patients who had coronary artery disease and 24 (89%) of the 27 patients with nonischemic cardiomyopathy were correctly identified. The accuracy of coronary echocardiography was 86% in the entire study group and 93% when patients with inadequate studies were excluded. All subjects who had ischemic cardiomyopathy had evidence of disease by coronary echocardiography or segmental wall motion abnormalities. Multivariate analysis permitted correct classification of 93% of all subjects based on the results of the coronary echocardiogram, evaluation of segmental wall motion and a history of prior myocardial infarction. The correct diagnosis was made in 86% when the results of coronary echocardiography were excluded from analysis using all other echocardiographic and clinical variables. Transthoracic coronary echocardiography can be performed with a high degree of success in patients with dilated ventricles and the technique can reliably distinguish between ischemic and nonischemic dilated cardiomyopathy.

Cardiomyopathy, Dilated

Dobutamine stress echocardiography as a predictor of cardiac events associated with aortic surgery.

Two-dimensional echocardiography can detect regional wall motion abnormalities resulting from myocardial ischemia produced by dobutamine infusion. In 60 patients undergoing elective aortic surgery (27 with aneurysms, 33 with occlusive disease), we evaluated the ability of dobutamine stress echocardiography to predict perioperative cardiac events. Echo images were obtained at rest and during incremental dobutamine infusion to a peak dose of 50 micrograms/kg/min, unless another test end point was reached (angina, heart rate greater than or equal to 85% of age-predicted maximum, significant ST segment depression, or new stress-induced wall motion abnormalities). Dobutamine stress echocardiography results were stratified as follows: group I, no wall motion abnormalities; group II, resting wall motion abnormalities unchanged with stress; group III, stress-induced worsening of resting wall motion abnormalities; group IV, new-onset wall motion abnormalities with stress. Twelve cardiac events occurred within the first 30 postoperative days: three cardiac deaths (5%), six nonfatal myocardial infarctions (10%), two patients with unstable angina (3.3%), and one patient with asymptomatic elevation of creatine phosphokinase MB isoenzymes without electrocardiographic changes (1.7%). Eleven events occurred in the 38 patients with an abnormal dobutamine stress echocardiograph (groups II to IV); in contrast, only one of 22 patients with a normal dobutamine stress echocardiograph (group I) had a cardiac event. These event rates (29% vs 4.6%) differed significantly (p less than 0.025). Dobutamine stress echocardiography is a new, safe, rapid, relatively low cost, noninvasive, nonexercise cardiac stress test for risk stratification before major vascular surgery.

Aged

Transoesophageal pulsed wave Doppler measurement of cardiac output during major vascular surgery: comparison with the thermodilution technique.

We measured cardiac output in 12 patients undergoing elective abdominal vascular surgery at specific times during the procedure with simultaneous thermodilution and transoesophageal pulsed Doppler echocardiographic techniques. No patient had clinical evidence of valvular heart disease before surgery. Five patients had echocardiographic evidence of mitral regurgitation on colour-coded Doppler. Using Bland and Altman analysis to compare the cardiac output measurement by the two techniques, the Doppler method overestimated the cardiac output (bias = 0.86 litre min-1) compared with the thermodilution technique and there were wide limits of agreement between the two techniques (+2.4 to -4.1 litre min-1). However, in the seven patients with no evidence of mitral regurgitation, closer agreement (bias 0.14 litre min-1) and narrower limits (+1.6 to -1.3 litre min-1) were observed. We conclude that, in patients with competent mitral valves, transoesophageal echocardiograph may provide accurate determination of cardiac output.

Aorta

Agitation and postdexamethasone cortisol levels in Alzheimer's disease.

The clinical correlates of hypothalamic-pituitary-adrenal (HPA) functioning were examined in 29 patients with probable Alzheimer's disease. The 8:00 a.m. postdexamethasone cortisol levels of these patients were highly correlated with higher agitation scores but not with the degree of depressed mood or memory impairment. The possible neural basis for the association between hypercortisolism and behavioral disturbance in Alzheimer's disease warrants further exploration and replication.

Alzheimer Disease

Sudden infant death syndrome in New Jersey: 1991.

Sudden infant death syndrome (SIDS) is the leading cause of death in infants one month to one year of age. The New Jersey Sudden Infant Death Syndrome Resource Center gathers epidemiological data on all SIDS deaths in New Jersey, noting differences in population and countries.

Humans

Thymus-dependent network responses to a monoclonal cross-reactive antiidiotypic antibody.

BALB/c mice were inoculated i.p. with a cross-reactive anti-Idiotypic mAb (designated FD5-1) in the absence of Ag or adjuvants. Injection with unmodified FD5-1 resulted in the induction of serum antibodies reactive with both FD5-1 (Ab3) and the hapten DNP (Ab1'). Endpoint titers of the Ab3 response showed an increase in serum IgM, which was dose-responsive to both the number of injections and the amount of FD5-1 antibody injected. The serum IgM Ab3 response was found to be thymus dependent and idiotypically specific for FD5-1. Athymic mice injected with FD5-1 were unable to produce a serum IgM Ab3 response, whereas their euthymic littermates produced strong Ab3 responses. Serum Ab3 responses and Ab1' were detectable only in the IgM isotype; no specific IgG responses were observed. Indeed, IgG recognized by FD5-1 appeared to be suppressed by FD5-1. Injection of mice with FD5-1 modulated serum IgM responses to DNP, (4-hydroxy-3-nitrophenyl)acetyl (NP), 4-ethoxymethylene-2-phenyloxazol-5-one (OX), phosphorylcholine (PC), and alpha 1,3-dextran (DEX) in a thymus-dependent manner. FD5-1 injection induced IgM responses against DNP, (4-hydroxy-3-nitrophenyl)acetyl (NP), 4-ethoxymethylene-2-phenyloxazol-5-one, and DEX but decreased IgM binding to PC. No detectable Ab1' responses to any of the aforementioned molecules were found when the same sera were probed for IgG. The specificity of serum Ab1' from FD5-1-injected mice was evaluated by antigenic inhibition. Binding of serum Ab1' to DNP-BSA was inhibitable by DNP-lysine, whereas equivalent concentrations of lysine alone had no inhibitory effect. The antigenic specificity of IgM from normal serum binding to PC-BSA was demonstrated by inhibition with free PC, and the binding of Ab1' from FD5-1-injected mice to DEX-coated plates was shown to be inhibitable by DEX. We have described in vivo network perturbation in adult BALB/c mice injected with anti-Id antibody in the absence of Ag or adjuvants. Our findings show that injection of the cross-reactive anti-Id FD5-1 can induce thymus-dependent Ag-specific responses. In two systems where FD5-1 functions as an anti-anti-anti-Id antibody (PC and DEX), thymus-dependent responses were also observed. FD5-1 injection suppressed antibodies binding to PC, whereas DEX-specific responses were induced.

Animals

Segmental wall motion abnormalities in the absence of clinically documented myocardial infarction: clinical significance and evidence of hibernating myocardium.

To determine the frequency and significance of left ventricular wall motion abnormalities in patients without clinical evidence of myocardial infarction, we reviewed the two-dimensional echocardiograms of 252 patients who had no history or electrocardiographic evidence of myocardial infarction and who subsequently underwent coronary angiography. Seventy-seven patients (31%) had one or more segmental wall motion abnormalities. Sixty-six of the 77 patients (86%) had significant coronary artery disease (greater than or equal to 50% luminal diameter stenosis). Seventy-four percent of the patients with coronary artery disease had multivessel disease. The left ventricle was divided into anterior and posterior regions. In the 66 patients, there were 77 separate regions with wall motion abnormalities (49 hypokinesis, 22 akinesis, 6 dyskinesis), including 60 regions (78%) supplied by coronary vessels with greater than or equal to 70% stenosis. Thirty-two patients underwent coronary artery bypass surgery or percutaneous transluminal coronary angioplasty. Follow-up echocardiograms were obtained in 19 patients who had wall motion abnormalities involving 22 regions. Twenty of the 22 regions were revascularized. Wall motion improved in 17 of 20 regions (85%) and returned to normal in 15 regions (75%). We conclude that segmental wall motion abnormalities may be detected by echocardiography in up to one third of patients evaluated for suspected coronary artery disease without documented myocardial infarction. These abnormalities are associated with a high likelihood of multivessel disease as well as with significant narrowing of the artery supplying the region demonstrating abnormal wall motion. Improvement in segmental wall motion abnormalities after revascularization suggests that these areas represent regions of hibernating myocardium.

Adult

RTOG quality assurance guidelines for clinical trials using hyperthermia for deep-seated malignancy.

Quality assurance has been vague or lacking in many previous hyperthermia trials. Recent publications by the Hyperthermia Physics Center, the Center for Devices and Regulatory Health, and the Radiation Therapy Oncology Group have described general guidelines for quality assurance in equipment reliability and reproducibility, superficial applications, and microwave techniques. The present report details quality assurance factors that are believed to be important for hyperthermia of deep clinical sites, defined as extending at least 3 cm beyond the skin surface. This document will discuss patient and physician factors, as well as thermometric accuracy, assessment of specific absorption rates (SAR), assurance of adequate coverage of tumors by the energy deposition pattern of the treatment device, and recommended documentation of the location, quantity, and frequency of treatment, specifically oriented to deep hyperthermia. The recommendations are structured to facilitate compliance in multiinstitutional trials.

Clinical Protocols

RTOG quality assurance guidelines for interstitial hyperthermia.

This document specifies the current recommendations for quality assurance for hyperthermia administration with interstitial techniques as specified by the Radiation Therapy Oncology Group (RTOG). The document begins by providing a brief description of the physical principles behind the use of the three most commonly used methods of interstitial hyperthermia: radiofrequency (RF-LCF), microwave antennas, and ferromagnetic seeds. Emphasis is placed on features that effect quality assurance. Specific recommendations are provided for: a) Pretreatment planning and equipment performance checks, b) Implant considerations and documentation, c) Thermometry, and d) Safety procedures. Specific details regarding quality assurance issues that are common to all local and regional hyperthermia methods are outlined in previous documents sponsored by the RTOG. It is anticipated that technological advances may lead to future modifications of this document.

Documentation

End-systolic regional wall stress-length and stress-shortening relations in an experimental model of normal, ischemic and reperfused myocardium.

Assessment of left ventricular function is influenced by a number of hemodynamic factors. The purpose of this study was to evaluate the end-systolic regional wall stress-dimension relation in a series of 25 mongrel dogs. In Group A (n = 18) the regional wall stress-velocity of circumferential fiber shortening relation was measured before and after three interventions: volume infusion, metoprolol infusion and dobutamine infusion. The electrocardiogram, left ventricular pressure and its first derivative (dP/dt), arterial pressure and echocardiograms were recorded at baseline and after phenylephrine administration (to increase afterload). For each dog values for regional wall stress were plotted against the velocity of circumferential fiber shortening. For all dogs the relations were inversely linear (r = -0.65 to -0.98). Volume infusion increased end-diastolic volume (p less than 0.05) without shifting the slope or intercept of the relation, indicating its independence from preload. Dobutamine caused a shift in the intercept to the right but no change in slope and metoprolol shifted the relation to the left without altering the slope. The effect of ischemia and reperfusion on the end-systolic regional wall stress-length relation was examined in Group B (n = 7), at baseline, after 5 min of mid-left anterior descending coronary artery occlusion and after 10 min of reperfusion. Afterload was increased by hydraulic aortic occlusion. Regional wall stress was lowest at baseline, highest during ischemia and intermediate after reperfusion (100.2 +/- 32.1, 193.5 +/- 81.5, 141.9 +/- 67.6 kdyn/cm2, respectively, p less than 0.001). The end-systolic regional wall stress-length relation was linear during baseline, ischemia and reperfusion (r = 0.96, 0.95, 0.98, respectively, p less than 0.05). Ischemia caused an increase in the slope and a shift in the intercept to the right compared with baseline. Reperfusion represented an incomplete return toward baseline. This study demonstrates that the regional wall stress-velocity of circumferential fiber shortening relation is linear, independent of preload, incorporates afterload and is sensitive to changes in contractility. In addition, the regional wall stress-length relation can be measured in a nonhomogeneously contracting left ventricle and is predictably altered by ischemia and reperfusion. This relation may prove useful to determine whether alterations in regional systolic function result from changes in local load or contractility in the left ventricle with a regional wall motion abnormality.

Animals

Regulation of atrial natriuretic peptide release in normal humans.

Atrial volume, pressure, and heart rate are considered the most important modulators of atrial natriuretic peptide (ANP) release, although their relative role is unknown. Continuous positive-pressure breathing in normal humans may cause atrial pressure and atrial volume to go in opposite directions (increase and decrease, respectively). We utilized this maneuver to differentially manipulate atrial volume and atrial pressure and evaluate the effect on ANP release. Effective filling pressure (atrial pressure minus pericardial pressure) was also monitored, because this variable has been proposed as another modulator of ANP secretion. We measured right atrial (RA) pressure, RA area, esophageal pressure (reflection of pericardial pressure), and RA and peripheral venous ANP in seven healthy adult males at rest and during continuous positive-pressure breathing (19 mmHg for 15 min). Continuous positive-pressure breathing decreased RA area (mean +/- SE, *P less than 0.05) 13.6 +/- 1.1 to 10.5 +/- 0.8* cm2, increased RA pressure 4 +/- 1 to 16 +/- 1* mmHg, increased esophageal pressure 2 +/- 1 to 12 +/- 1* mmHg, and increased effective filling pressure 2 +/- 0 to 4 +/- 1* mmHg. RA ANP increased from 67 +/- 17 to 91 +/- 18* pmol/l and peripheral venous ANP from 43 +/- 4 to 58 +/- 6* pmol/l.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Echocardiographic detection of coronary artery disease during dobutamine infusion.

BACKGROUND: Two-dimensional echocardiography performed during dobutamine infusion has been proposed as a potentially useful method for detecting coronary artery disease. However, the safety and diagnostic value of dobutamine stress echocardiography has not been established. METHODS AND RESULTS: In this study, echocardiograms were recorded during step-wise infusion of dobutamine to a maximum dose of 30 micrograms/kg/min in 103 patients who also underwent quantitative coronary angiography. The echocardiograms were digitally stored and displayed in a format that allowed simultaneous analysis of rest and stress images. Development of a new abnormality in regional function was used as an early end point for the dobutamine infusion. No patient had a symptomatic arrhythmia or complications from stress-induced ischemia. Significant coronary artery disease (greater than or equal to 50% diameter stenosis) was present in 35 of 55 patients who had normal echocardiograms at rest. The sensitivity and specificity of dobutamine-induced wall motion abnormalities for coronary artery disease was 89% (31 of 35) and 85% (17 of 20), respectively. The sensitivity was 81% (17 of 21) in those with one-vessel disease and 100% (14 of 14) in those with multivessel or left main disease. Forty-one of 48 patients with abnormal echocardiograms at baseline had localized rest wall motion abnormalities. Fifteen had coronary artery disease confined to regions that had abnormal rest wall motion, and 26 had disease remote from these regions. Thirteen of 15 patients (87%) without remote disease did not develop remote stress-induced abnormalities, and 21 of 26 (81%) who had remote disease developed corresponding abnormalities. CONCLUSIONS: Echocardiography combined with dobutamine infusion is a safe and accurate method for detecting coronary artery disease and for predicting the extent of disease in those who have localized rest wall motion abnormalities.

Adrenergic beta-Antagonists