PubMed Health⌕ Search

Biomedical subjects

T Saga

Publications and source records attributed to T Saga.

At least 19 recordsLinked to original sources

Residual formaldehyde on plastic materials and medical equipment following low-temperature steam and formaldehyde sterilization.

We measured the amount of residual formaldehyde on 16 plastic materials and five medical devices following low-temperature steam and formaldehyde (LTSF) sterilization, based on the European Standard EN14180. The amounts of formaldehyde residue on the plastic materials were compared with that on a filter paper of similar dimensions. The amount of residual formaldehyde on polyamide 6, polyurethane, natural rubber and polyacetal was higher (21.9, 15.2, 3.0 and 2.1 times, respectively) than that on the filter paper. The amount of formaldehyde recovered from a breathing circuit, anaesthesia circuit, oxygen tubing, airway tube and tweezers was 260, 240, 594, 56 and 0 microg, respectively, following LTSF sterilization. Our results emphasize the need to verify the main material composing the medical equipment before LTSF sterilization, as the amount of formaldehyde retrieved following sterilization varies according to the material used for construction.

Cross Infection↗

Delayed esophageal necrosis and perforation secondary to thoracic aortic rupture: a case report and review of the literature.

Delayed esophageal necrosis secondary to aortic rupture is extremely rare but potentially fatal. Although diagnostic techniques have improved, survival remains rare. The clinical and imaging features have not been characterized, as no large series have been reported since the advent of computed tomography (CT) and endoscopy. Moreover, as delayed esophageal necrosis secondary to aortic rupture is rarely anticipated, diagnosis is usually delayed. We recently encountered a case of this complication and present this along with a literature review, in order to facilitate early recognition and treatment. In many cases, hemodynamics remain relatively stable despite aortic rupture and the long interval between onset and operation. Dysphagia is therefore an important symptom that may indicate compression of the esophagus and subsequent esophageal necrosis. Preoperative total obstruction of the esophagus on barium swallow, endoscopy, or CT is also an important feature suggesting ischemic change of the esophagus. Endoscopy often reveals an annular ulcer suggestive of an ischemic process leading to necrosis. Death generally occurs from severe mediastinitis occurring after graft repair of the aorta. We recommend performing postoperative endoscopy after aortic surgery when preoperative obstruction of esophagus is found. If endoscopy reveals annular necrosis, surgical treatment involving esophagectomy and omental translocation should be performed expediently before perforation occurs.

Aged, 80 and over↗

Morphological imaging in the localization of neuroendocrine gastroenteropancreatic tumors found by somatostatin receptor scintigraphy.

PURPOSE: To evaluate the necessity of morphological images (MI) in reading somatostatin receptor scintigraphy (SRS) in patients with suspected neuroendocrine gastroenteropancreatic (GEP) tumors. MATERIAL AND METHODS: A Japanese multicenter clinical trial of SRS was conducted in 40 patients with suspected GEP tumors. Three experienced radiologists interpreted the images in three separate sessions in a blinded manner (1: SRS images alone, 2: MI alone, 3: SRS and MI analyzed simultaneously), and the reading results of each session were compared. In addition, the diagnostic abilities of SRS, MI and SRS alone and simultaneous SRS and MI readings were compared for patients where final diagnosis was obtained. RESULTS: SRS detected more suspected lesions (positive or inconclusive uptake) than morphological images did (51 vs 27 lesions), but included many physiological uptakes detected as positive or inconclusive uptakes. Combined reading of SRS and morphological images helped to correctly recognize these physiological uptakes, and also helped in determining the anatomical localization of the abnormal uptakes. Combined reading of SRS and morphological images gave the highest diagnostic impact. CONCLUSION: The sensitivity of SRS with regard to GEP is high. However the specificity is very low. Morphologic imaging is necessary for the exclusion of physiological uptake and correct anatomic location of an abnormal tracer uptake. The combined reading of SRS and morphologic imaging studies gives the highest diagnostic impact.

Adenocarcinoma↗

Evaluation of a fully automated system (RAISUS) for rapid identification and antimicrobial susceptibility testing of Staphylococci.

RAISUS is a system for rapid bacterial identification and antimicrobial susceptibility testing. RAISUS and VITEK showed 97.8% and 75.9% agreement in identification of 45 Staphylococcus aureus strains and 58 coagulase-negative staphylococci (CoNS), respectively, and RAISUS and CLSI (formerly NCCLS) methods showed 87.2% and 87.9% agreement in the MICs for S. aureus and CoNS, respectively. RAISUS provided these data within 3.75 h, suggesting its utility for clinical bacteriological laboratories.

Anti-Bacterial Agents↗

Elastic moduli of thyroid tissues under compression.

The aim of this study was to evaluate the elastic moduli of thyroid tissues under uniaxial compression and to establish the biomechanical fundamentals for accurate interpretation of thyroid elastograms. A total of 67 thyroid samples (24 samples of normal thyroid tissue, 2 samples of thyroid tissue with chronic thyroiditis, 12 samples of adenomatous goiter lesions and 7 samples of follicular adenoma, 19 samples of papillary adenocarcinoma (PAC) and 3 samples of follicular adenocarcinoma (FAC)) obtained from 36 patients who had received thyroid surgery were subjected to biomechanical testing within three hours after surgical resection at precompression strains of 5%, 10% and 20% and applied strains of 1%, 2%, 5% and 10% of sample height. As a result, the mean values of elastic moduli for benign thyroid lesions at all examined precompression levels were significantly higher than those for normal thyroid tissue measured at the same load (p<0.01). At low precompression (5%) and compression (1-2%) levels, benign thyroid nodule samples were 1.7 times harder than normal thyroid tissue. At high precompression (20%) and compression (10%) levels, this difference increased to 2.4 times. Stiffness of PAC samples was significantly higher than those for normal thyroid tissue and benign thyroid tumors measured at the same load (p<0.01). At low precompression (5%) and compression (1-2%) levels, PAC samples were 5.0 times harder than normal thyroid tissue. At high precompression (20%) and compression (10%) levels, this difference increased to 17.7 times. In contrast, samples of FAC were much softer than PAC (p<0.05) and were comparable in stiffness to normal thyroid tissues. The significant differences in the stiffness between normal thyroid tissue and thyroid tumors may provide useful information for accurate interpretation of thyroid elastograms.

Adult↗

Obstructed coarctation in a right aortic arch in an adult female.

Coarctation of a right aortic arch is rare congenital anomaly. We report a rare case of a 24-year-old female with coarctation of the right aortic arch with aberrant left subclavian artery between the right common carotid and right subclavian arteries. The coarctation progressed into complete obstruction as the interruption of the aorta in adulthood. To prevent cerebral complications and progression to heart failure, surgical procedure was selected. Extraanatomical bypass grafting between the ascending and descending aorta was successfully performed using cardiopulmonary bypass. Some patients diagnosed with interruption of the aortic arch in adulthood might be displaying progression of undiagnosed coarctation, as our in case. Three-dimensional computed tomography was useful to detect the obstructive lesion and to determine the surgical approach and methods.

Aortic Coarctation↗

Williams syndrome associated with complete atrioventricular septal defect.

Williams syndrome is a genetic disorder associated with characteristic facies, supravalvar aortic stenosis, peripheral pulmonary stenosis, mental retardation, hypertension, premature aging of skin, and congenital cardiac defects. Many cardiac defects such as bicuspid aortic valve, mitral valve regurgitation, coarctation of the aorta, and ventricular or atrial septal defects are linked to the syndrome. Complete atrioventricular septal defect has rarely been associated with Williams syndrome and only one necropsy case has been reported in the literature. The long term follow up of Williams syndrome associated with complete atrioventricular septal defect is reported. During a 10 year follow up period, the pressure gradient in the ascending aorta did not increase despite narrowing of the ascending aorta as identified on an aortogram.

Adolescent↗

Carotid artery intima-media thickness and brachial artery flow-mediated vasodilation in asymptomatic Japanese male subjects amongst apolipoprotein E phenotypes.

BACKGROUND: Epidemiological studies suggest that apolipoprotein E (apoE) polymorphism influences plasma lipoprotein levels and the development of cardiovascular disease. OBJECTIVE: To clarify the role of apoE polymorphism as a risk factor for early atherosclerosis. DESIGN: Using a high-resolution ultrasound method, we investigated the association between apoE phenotypes, carotid intima-media thickness (CCA-IMT), and flow-mediated dilation in the brachial artery (brachial-FMD) in 96 healthy asymptomatic Japanese men (mean +/- SD age, 50 +/- 8 years). RESULTS: Serum cholesterol and LDL-cholesterol levels in subjects with E3E4 were highest and those with E2E3 were lowest (P < 0.05 and P < 0.05, respectively). The CCA-IMT in E3E4 subjects (0.76 +/- 0.17 mm) was greater than that in E2E3 and E3E3 (0.61 +/- 0.15 and 0.64 +/- 0.14 mm, respectively; P < 0.01). In contrast, there was no difference between brachial-FMD and apoE phenotypes (P=0.15). By univariate analysis, CCA-IMT was positively correlated with age (r=0.51, P < 0.01), LDL-chol/HDL-chol ratio (r=0.37, P < 0.01), triglycerides (r=0.23, P < 0.05), and negatively correlated with HDL-cholesterol (r=-0.31, P < 0.01). An association between CCA-IMT and the presence of E4 allele was also found (P < 0.05). Logistic regression analysis revealed that the presence of E4 allele was a higher risk for increased IMT (relative risk of 4.4, 95% CI 1.5-12.5), even after adjustment for age, LDL-cholesterol, blood pressure and other known risk factors. A negative correlation between brachial-FMD and CCA-IMT was also found in all subjects (r=-0.21, P < 0.05), being most apparent in the E3E4 subjects (r=-0.53, P < 0.02). CONCLUSION: ApoE4 phenotype was independently associated with an increased risk of carotid atherosclerosis and elevated LDL-cholesterol levels in asymptomatic middle-aged Japanese men.

Adult↗

Simultaneous quantification of prostaglandins in human synovial cell-cultured medium using liquid chromatography/tandem mass spectrometry.

A liquid chromatographic-tandem mass spectrometric (LC/MS-MS) method was developed for the simultaneous quantification of prostaglandin (PG) E(2), PGF(2alpha), 6-keto-PGF(lalpha) and thromboxane (TX) B(2). These eicosanoids and their deuterium derivatives, using as internal standards, were extracted by solid-phase extraction and analyzed using LC/MS-MS in the selected reaction-monitoring (SRM) mode. A good linear response over the range of 10 pg to 10 ng for each eicosanoid was demonstrated. The accuracy of added eicosanoids ranged from 94.1 to 106.6% and coefficients of variation ranged from 0.62 to 7.8%. Furthermore, we applied this method for the determination of eicosanoids in the human synovial cell-cultured medium, stimulated by lipopolysaccharide (LPS). LPS produced each eicosanoid and they increased in a time-dependent manner. The production levels after 24 h stimulation were 6-keto-PGF(1alpha) > PGE(2) > TXB(2) >> PGF(2alpha). This simultaneous quantification method is so useful to clarify the function of synovial cells in rheumatoid arthritis (RA).

Calibration↗

[Pitfall of modified ultrafiltration in pediatric cardiac surgery].

Since June, 1998, modified ultrafiltration (MUF) was performed for 92 consecutive children who underwent cardiac surgery using cardiopulmonary bypass, except those with atrial septal defect. Among 92 cases, MUF could not be completed in two cases because of the accident that many air bubbles were found in the arterial line of the CPB circuit. The causes of such trouble were discussed.

Cardiopulmonary Bypass↗

Dynamic micro-magnetic resonance imaging of liver micrometastasis in mice with a novel liver macromolecular magnetic resonance contrast agent DAB-Am64-(1B4M-Gd)(64).

DAB-Am64-(1B4M-Gd)(64) is a newly synthesized macromolecular liver magnetic resonance imaging (MRI) contrast agent with a polypropylenimine diaminobutane (DAB) dendrimer conjugated with a bifunctional diethylenetriaminepentaacetic acid (DTPA) derivative for complexing Gd(III) atoms. The characteristics of DAB-Am64-(1B4M-Gd)(64), which quickly accumulated in the liver, have been reported recently. In the present study, the dynamic micro-MRI with DAB-Am64-(1B4M-Gd)(64) was obtained in the mouse liver metastasis model using colon carcinoma cells to evaluate the ability to visualize the micrometastatic tumors compared with that using Gd-DTPA. The dynamic micro-MRI with DAB-Am64-(1B4M-Gd)(64) was able to homogeneously enhance the normal liver parenchyma and visualize micrometastatic tumors of 0.3-mm diameter in the liver of the mice with better contrast than that with Gd-DTPA. In conclusion, DAB-Am64-(1B4M-Gd)(64) is a new liver MRI contrast agent potentially useful for diagnosis of micrometastasis in the liver.

Animals↗

Tumour enhancement with newly developed Mn-metalloporphyrin (HOP-9P) in magnetic resonance imaging of mice.

The purpose of the study is to evaluate the tumour enhancing characteristics and biodistribution of a newly developed metalloporphyrin derivative, HOP-9P (13, 17-bis (1-carboxypropionyl) carbamoylethyl-3, 8-bis (1-phenylpropyloxyethyl)-2,7,12,18-tetra- methyl-porphynato manganese (III)). Seven mice bearing SCC VII tumours were imaged using T1-weighted conventional spin echo magnetic resonance images before and 5 min, 2 h and 24 h after intravenous injection of 0.1 mmol/kg of HOP-9P. For the acquired images, signal intensities of the tumour, muscle and oil-phantom were measured. Then, tumor/oil and tumor/muscle signal intensity ratios were calculated. Nineteen mice were sacrificed before or after the administration of HOP-9P (at 5 min, 2 h and 24 h), and the biodistribution of manganese in the tumour, muscle, liver, blood and kidneys was measured using optical emission spectrometers and was expressed as micrograms of manganese per gram of tissue. The tumour/muscle signal intensity ratio at 24 h (3.18 +/- 0.34) was significantly higher than precontrast ratio (1.77 +/- 0.20) (P < 0.05). The biodistribution assessment of manganese demonstrated that HOP-9P gradually and consistently accumulated in the tumour to reach the highest concentration at 24 h (3.49 +/- 1.22 micro gMn/g). It is concluded that HOP-9P is a potential tumour-specific MR contrast agent.

Animals↗

3D-micro-MR angiography of mice using macromolecular MR contrast agents with polyamidoamine dendrimer core with reference to their pharmacokinetic properties.

Four novel macromolecular MRI contrast agents, all of which had the same chemical composition but different molecular weights, were prepared using generation-3, -4, -5, and -6 polyamidoamine (PAMAM) dendrimers conjugated with a bifunctional diethylenetriaminepentaacetic acid derivative to change the blood retention, tissue perfusion, and excretion. Size-dependent changes in the pharmacokinetics were observed in the biodistribution study. (153)Gd-labeled generation-6 PAMAM-conjugates remained in the blood significantly longer than all of the other preparations (P < 0.001). The increase in blood-to-organ ratio of the preparations was found to correlate with increasing molecular size (P < 0.001). Additionally, 3D-micro MR images and angiography of mice of high quality and detail were obtained using PAMAM-(1B4M-Gd)x as a macro-molecular MRI contrast agent with a 1.5-T clinical MRI instrument. Numerous fine vessels of approximately 200 microm diameter were visualized on subtracted 3D-MR angiographms with G6D-(1B4M-Gd)(192). The quality of the images was sufficient to estimate the microvasculature of cancerous tissue for anti-angiogenesis therapy and to investigate knockout mice. Magn Reson Med 45:454-460, 2001.

Animals↗

Micro-MR angiography of normal and intratumoral vessels in mice using dedicated intravascular MR contrast agents with high generation of polyamidoamine dendrimer core: reference to pharmacokinetic properties of dendrimer-based MR contrast agents.

Pharmacokinetic characteristics of intravascular macromolecular magnetic resonance imaging (MRI) contrast agents with polyamidoamine dendrimer cores smaller than generation-7 were previously studied in the literature. To evaluate the effects of greater hepatic uptake on the pharmacokinetics of the larger generation dendrimers, the MRI contrast agents GxD-(1B4M-Gd)(2(x+2)) were synthesized with generation-7, -8, and -9 polyamidoamine dendrimers and 2-(p-isothiocyanatobenzyl)-6-methyl-diethylenetriaminepentaacetic acid (1B4M). Their pharmacokinetic characteristics in mice were compared with that of G6D-(1B4M-Gd)(256). In biodistribution and dynamic micro-MRI studies, significantly less renal accumulation of G7D-(1B4M-Gd)(512), G8D-(1B4M-Gd)(1024), and G9D-(1B4M-Gd)(2048) was shown compared to G6D-(1B4M-Gd)(256) (P < 0.01). There was a significantly greater accumulation of G8D-(1B4M-Gd)(1024) and G9D-(1B4M-Gd)(2048) in the liver compared to G6D-(1B4M-Gd)(256) and G7D-(1B4M-Gd)(512) (P < 0.01). The highest blood retention of all dendrimer-based MRI contrast agents was exhibited by G7D-(1B4M-Gd)(512) (P < 0.01). The normal and intratumoral fine vessels of approximately 100 microm diameter were visualized in normal or tumor-bearing mice by high resolution three-dimensional-micro-MR angiographs with G7D-(1B4M-Gd)(512) and G8D-(1B4M-Gd)(1024) with good vessel-to-soft tissue contrast. In summary, increased accumulation in the liver with concomitant decreased uptake in the kidney was caused by increased molecular sizes of the dendrimer-based MRI contrast agents.

Analysis of Variance↗

Novel intravascular macromolecular MRI contrast agent with generation-4 polyamidoamine dendrimer core: accelerated renal excretion with coinjection of lysine.

One of the major limitations to macromolecular MRI contrast agents (MRI-CAs) is their slow clearance and associated decreased excretion of gadolinium (Gd(III)). The effect of coinjecting lysine to accelerate renal excretion of a macromolecular MRI-CA (generation-4 PAMAM dendrimer (G4D-(1B4M-Gd)64)) was investigated. The biodistribution and urine and fecal excretion in athymic mice was evaluated with and without lysine coinjection. 3D-dynamic-micro-MRI with G4D-(1B4M-Gd)64 was obtained with and without lysine coinjection, and the serial signal intensity (SI) change in the blood and organs was evaluated. When lysine was coinjected, urinary excretion of G4D-(1B4M-Gd)64 increased 5.4-fold compared to that without lysine, resulting in decreased renal accumulation of G4D-(1B4M-Gd)64 from 150% to 40% injected dose per gram (P < 0.001). On dynamic MRI with G4D-(1B4M-Gd)64, when lysine was coinjected, the kidney-to-blood SI ratio was significantly lower than that obtained without lysine (P < 0.001). When lysine was coinjected, the G4D-(1B4M-Gd)64 was excreted from the kidney intact.

Animals↗

3D MR angiography of intratumoral vasculature using a novel macromolecular MR contrast agent.

Noninvasive methods to visualize blood flow in the intratumoral vasculature have not previously been studied. In the present study, the use of a novel intravascular MR contrast agent with a generation-6 polyamidoamine dendrimer core (G6-(1B4M-Gd)192; MW: 175kD) was investigated, and the vasculature in experimental tumors was visualized using 3D MR angiography (MRA). Xenografted tumors in nude mice of two different histologies-KT005 (human osteogenic sarcoma) and LS180 (human colon carcinoma)-were used to obtain 3D MRA using G6-(1B4M-Gd)192 and Gd-DTPA. The contrast MR sectional images were correlated with the corresponding histological sections. The intratumoral vasculature in the KT005 tumor was clearly visualized by 3D MRA, which became more evident with the growth of the tumor xenograft. In contrast, the intratumoral vasculature in the LS180 tumor was sparser and much less developed than that in KT005 tumors. Blood vessels with a diameter as small as 100 microm based on histology were visualized using 0.033 mmol Gd/kg of G6-(1B4M-Gd)192. In conclusion, intratumoral vasculature with a 100-microm diameter was visualized better using 3D MRA with G6-(1B4M-Gd)192 than with Gd-DTPA.

Animals↗

Positive effects of polyethylene glycol conjugation to generation-4 polyamidoamine dendrimers as macromolecular MR contrast agents.

Macromolecules conjugated with polyethylene glycol (PEG) acquire more hydrophilicity, resulting in a longer half-life in circulation and lower immunogenicity. Two novel conjugates for MRI contrast agents were synthesized from a generation-4 polyamidoamine dendrimer (G4D), 2-(p-isothiocyanatobenzyl)-6-methyl-diethylenetriaminepentaacetic acid (1B4M), and one or two PEG molecules with a molecular weight of 20000 Da (PEG(2)-G4D-(1B4M-Gd)(62) (MW: 96 kD), PEG(1)-G4D-(1B4M-Gd)(63) (MW: 77 kD)). Their pharmacokinetics, excretion, and properties as vascular MRI contrast agents were evaluated and compared with those of G4D-(1B4M-Gd)(64) (MW: 57 kD). PEG(2)-G4D-(1B4M-Gd)(62) remained in the blood significantly longer and accumulated significantly less in the liver and kidney than the other two preparations (P < 0.01). Although the blood clearance was slower, PEG(2)-G4D-(1B4M-Gd)(62) was excreted more readily without renal retention than the other two preparations. In conclusion, the positive effects of PEG conjugation on a macromolecular MRI contrast agent were found to be prolonged retention in the circulation, increased excretion, and decreased accumulation in the organs.

Animals↗

Novel liver macromolecular MR contrast agent with a polypropylenimine diaminobutyl dendrimer core: comparison to the vascular MR contrast agent with the polyamidoamine dendrimer core.

As MRI contrast agents, more hydrophobic molecules reportedly accumulate in the liver and thus are potentially useful as liver MRI contrast agents. In this study, a generation-4 polypropylenimine diaminobutane dendrimer (DAB-Am64), which is expected to be more hydrophobic than the generation-4 polyamidoamine dendrimer (PAMAM-G4D), was used to synthesize a conjugate with 2-(p-isothiocyanatobenzyl)-6-methyl-diethylenetriaminepentaacetic acid (1B4M) [DAB-Am64-(1B4M-Gd)(64)] for complexing Gd(III) ions. This DAB conjugate quickly accumulated in the liver and its characteristics were studied and compared with those of a PAMAM conjugate [PAMAM-G4D-(1B4M-Gd)(64)], which is known to be a useful vascular MRI contrast agent, in regard to its availability as a liver MRI contrast agent. DAB-Am64-(1B4M-Gd)(64) accumulated significantly more in the liver and less in blood than PAMAM-G4D-(1B4M-Gd)(64) (P < 0.001). Contrast-enhanced MRI with DAB-Am64-(1B4M-Gd)(64) was able to homogeneously enhance liver parenchyma and visualize both portal and hepatic veins of 0.5 mm diameter in mice. In conclusion, DAB-Am64-(1B4M-Gd)(64) is a good candidate for a liver MRI contrast agent.

Animals↗