Structure study of 42Ca by alpha +38Ar cluster model: Coexistence of alpha-particle clustering and shell structure.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to T Sakuda.
Explore the source record for details and available documents.
With the purpose of screening potential antimalarial agents, oxidized starch imine derivatives of sulfonamides or pyrimidine - derivatives of sulfisoxazole (ML8), sulfameter (ML11) and trimethoprim (ML13) - and oxidized cellulose imine derivatives of dapsone (ML14), sulfadiazine (ML17), sulfamethoxazole (ML18), sulfisoxazole (ML19), sulfamethoxypyridazine (ML20) and sulfameter (ML22) were submitted to in vivo biological assays with mice infected with Plasmodium berghei. Only ML11 was 100% curative in test conditions; ML 17 showed the same effect as its prototype. The drug content in both prodrugs is lower in the applied dose than that used in the original drugs. It can be suggested that the latentiation enhanced the effectiveness of the prototypes.
Explore the source record for details and available documents.
Previous studies found task and vision performance differences between presbyopic contact lens corrections and distant contact lenses combined with reading spectacles. The present study was designed to compare task and vision performance with single vision contact lenses and spectacles. Eighteen soft (SCL) and seventeen rigid gas permeable (RGP) successful contact lens wearers were examined and fitted with CR-39 spectacles (SPEX) which corrected their distance vision. Their occupational task performance and visual acuity (high contrast, low contrast, low contrast with glare) were measured while they wore their contact lenses and spectacles. The tasks included putting pointers in straws, filing cards in a box, counting letters on a photograph of a VDT screen, and a distance/near fixation task. Visual acuity scores were lower with SCL than with SPEX. Low contrast visual acuity with glare was reduced by 1.36 letters on a 5-letter row (p less than 0.05) for SCL compared to SPEX. No statistically significant differences in performance times were measured between contact lenses and spectacles. None of the error performance differences were statistically significant; however, more errors were made on each occupational task with soft contact lenses compared to spectacles. The findings suggest nearly equivalent task and visual performance with properly prescribed RGP contact lenses and spectacles, and minimal performance decrements with SCL compared to spectacles.