PubMed Health⌕ Search

Biomedical subjects

T Schwenteck

Publications and source records attributed to T Schwenteck.

3 recordsLinked to original sources

[Clinical evaluation of a new tonometer on the basis of international standard ISO 8612].

BACKGROUND: There is a continuous process of development of new tonometer types following different measurement principles on the tonometer market. A new tonometer working on the dynamic contour measurement principle is currently available for ophthalmologists. This device has special properties, since it determines the intraocular pressure as well as the ocular pulse amplitude. So far, clinical comparison measurements exist between the new tonometer Pascal and the applanation tonometer by Goldmann albeit without any reference to a standard. Besides, these measurements cover only a small pressure range between 7 mmHg and 23 mmHg which is not sufficient for medical diagnosis. PATIENTS AND METHODS: This new tonometer was investigated by clinical comparison measurements according to the currently valid international standard for human eye tonometers (ISO 8612). The tested tonometer determines the intraocular pressure without fluorescein. In an ophthalmogical hospital in Berlin the clinical comparison measurements were carried out by ophthalmologists on 127 patients according to the methods and criteria of the above-mentioned standard. A calibrated AT 870 from the Haag-Streit company served as reference tonometer. RESULTS: The different cornea surface geometries of individual eyes, the variation of tear liquid volume, and also the different elastic properties of the human eye due to a large variation in rigidity led to measurements of intraocular pressure by this tonometer with an excessively high number of outliers p (i) (i = 1, ..., 3) per group (p (1) = 16.28 %, p (2) = 8.85 %, p (3) = 15.69 %, 5.0 % outliers per group only are permitted for the differences method), which do not correspond to the requirements of the international standard for tonometers ISO 8612. This is also shown by application of total method of least squares of regression line (slope a = 0.964, interception b = 2.868 mmHg, standard deviation s (y) = 2.628 mmHg). CONCLUSIONS: The test of conformity of results of clinical comparison measurements to the international standard for tonometers ISO 8612 is the target of this work. The measurement results of the investigated tonometer are analysed and discussed according to this standard. Statements about the medical application of this medical measurement device for ophthalmologists are presented. According to the presented investigations the requirements of this international standard are not fulfilled by the tonometer Pascal.

Equipment Design↗

[New trends in tonometry].

BACKGROUND: Though the knowledge about the risk of elevated intraocular pressure for pathogenesis for development and progress of glaucoma is more than 400 years old. It took another 300 years before by means of tonometry this elevation could be quantified. After discussion of the key words it is our aim to demonstrate the latest trends in tonometry, specifically by use of modern electronics for instrument design. MATERIALS: Goldmann was the founder of the "applanation tonometry", measuring the corelation of applanated area and applied force. Here, the next step was the development of instruments, measuring independent of position or gravity to allow application also at the lying patient. Electronic area detection was the next step to avoid examinor's error. Also important was the introduction of automatic UV-desinfection to avoid contamination of the other eye or other patients. Other tonometers control the force applied by an inductive method, which also allows application independent of position. Airpuff-tonometry uses completely different measuring principles - the resulting change of corneal curvature indicates the intraocular pressure. The impedance principle is applied even through the closed eye lid. The shock waves resulting shall be measured. Direct application of a surface sensor incorporated into a concave surface contact body shall allow direct measurement of intraocular pressure independent of corneal thickness, curvature, astigmatism. This method has been tried for more than 20 years. Also exposition of the eye to count waves of different frequency was an early attempt. Here also change of reflectivity is used to calculate intraocular pressure. CONCLUSIONS: Even after use of modern electronic technology the precision of many of these new devices does not lead to better results. This specifically is shown by modern calibration methods.

Diagnosis, Computer-Assisted↗

[Clinical Testing of New Tonometers on the Basis of the International Standard for Human eye Tonometers ISO 8612].

There is a continuous process of development of new tonometer types following different measurement principles. The impedance measurement method, using the elasticity of the eyeball, allows tonometry even through the eyelid. Two new tonometers based on the impedance principle were investigated by clinical comparison measurements according to the international standard for human eye tonometers ( ISO 8612). The tested tonometers determine the intraocular pressure without topical anaesthesia. The different elastic properties of an individual eyelid and also the different elastic properties of the human eye due to a large variation in rigidity cause serious problems for these measurements. Statistical properties of the two investigated tonometers are presented and discussed. Statements and conclusions about the medical application of these measurement devices for ophthalmologists are made.

Elasticity↗