PubMed Health⌕ Search

Biomedical subjects

T Shigemitsu

Publications and source records attributed to T Shigemitsu.

At least 19 recordsLinked to original sources

Low stray ELF magnetic field exposure system for in vitro study.

An exposure facility for wide application to cell exposure to an ELF (extremely low frequency) magnetic field was developed. It is suitable for conducting experiments under a high-intensity, variable-frequency magnetic field, on the biological effects of the ELF magnetic field in an in vitro study. The exposure system consists of Merritt's 4-square coil as a basic component to generate the required magnetic field intensity of 10 mT at 50 Hz with spatial field uniformity less than +/-3% in a 400 mm cube. Concentric compensation coils are adopted to eliminate the effects of stray fields on sham (control) samples in the vicinity of the exposure system. The uniformity of the magnetic field in the exposure coil, the increase in the power supply capacity due to the existence of compensation coils, and the stray field estimation were investigated carefully. After fabricating the system, performance tests were carried out and all the characteristics were found to be satisfactory. In addition, the ideal configuration for a concentric coil system was proposed.

Animals↗

Immunocytochemical features of lens after cataract tissue--signalling molecules (growth factors, cytokines, other signalling molecules), cytoskeleton proteins, cellular and extracellular matrix proteins.

UNLABELLED: We examined the immunocytochemical features of after cataract tissue and cataractous lens epithelium prior to cataract surgery and at the time of surgery. METHODS: This study included 23 cases. Antibodies against the following antigens were used: epidermal growth factor (EGF), EGF receptor (EGF-R), fibroblast growth factor (FGF), FGF receptor (FGF-R), transforming growth factor (TGF)-beta, TGF-beta receptor II (TGF-beta -RII), insulin-like growth factor (IGF)II, platelet derived growth factor (PDGF)-AB, interleukin (IL)-6, IL-1 receptor II, tumor necrosis factor (TNF)-alpha, tissue plasminogen activator (TPA), prostaglandin (PG) E2, plasminogen activator inhibitor (PAI)-1, alpha smooth muscle actin (alpha-SMA), keratin, vimentin, myosin, fibronectin, laminin, types I, II, III, IV, V and VI collagen (Col), and lens epithelial cells (LECs). RESULTS: The following substances were present in posterior and anterior capsular fibrosis of after cataract: EGF, EGF-R, FGF, FGF-R, TGF-beta, TGF-beta-RII, IGF-II, PDGF-AB, IL-6, IL-1RII, TNF-alpha, PGE2, PAI-1, alpha-SMA, keratin, fibronectin, laminin, Type I col, Type II to VI col and LECs. Elschnig's pearls of after cataract expressed FGF-R, TNF-alpha, laminin and LECs. Soemmering's ring of after cataract tissue expressed EGF, FGF, FGF-R, IL-1RII, TPA, PAl-1, keratin and LECs. The following substances were present in cataractous lens epithelium prior to cataract surgery: EGF, EGF-R, FGF, FGF-R, TGF-beta-RII, IL-1-RII, TNF-alpha, PAI-1, keratin, laminin and LECs. The following substances were present in the lens epithelium of anterior capsules collected at the time of cataract surgery: EGF, EGF-R, FGF, FGF-R, TGF-beta, TGF-beta-RII, IGF-II, IL-6, IL-1-RII, TNF-alpha, PGE2, keratin, fibronectin, laminin, Type IV Col and LECs. CONCLUSIONS: These results prove that many kinds of signalling molecules and proteins exist in the process of after cataract formation.

Aged↗

Endoscopic management of gastric varices using a detachable snare and simultaneous endoscopic sclerotherapy and O-ring ligation.

BACKGROUND: Cyanoacrylate injection is highly effective and is regarded as the treatment of choice in bleeding gastric varices in Europe, but intravenous injection of cyanoacrylate is not allowed in the USA and Japan because it may cause embolisms in other organs. Accordingly, we developed a new endoscopic combined treatment of endoscopic management of gastric varices using a detachable snare (EVLs) and simultaneous endoscopic sclerotherapy and O-ring ligation (EISL) (i.e. EVLs + EISL), and we prospectively evaluated its efficacy and safety. METHODS: Gastric varices were ligated with the loop of a detachable snare that opened to a diameter of 4 cm (EVLs). Then the residual varices around the ligated portion were sclerosed by ethanolamine oleate and the injected vessel was ligated using a pneumo-activated EVL device (EISL). The EVLs + EISL was performed in 35 patients: on an emergency basis in eight patients, on an elective basis in six patients and as primary prophylaxis in 21 patients. Liver function was classified as Child-Pugh class A in 12 patients, class B in 12 patients and class C in 11 patients. RESULTS: Endoscopic disappearance of gastric varices was obtained in 97.1% of the patients and they regressed in all patients. Haemostasis was achieved in all eight emergency cases. The 2-year cumulative non-recurrence rate was 85%, the 2-year cumulative non-bleeding rate was 92% and the 2-year cumulative survival was 80%. No patients died of bleeding from gastric varices. There were no serious short-term complications, such as haemorrhage, gastro-oesophageal perforation, ileus, or renal impairment. CONCLUSION: Combined EVLs + EISL appears to be a useful treatment for gastric varices due to its safety and good clinical outcome.

Endoscopy↗

Linearly and circularly polarized, 50 Hz magnetic fields did not alter intracellular calcium in rat immune cells.

This study was conducted to determine if exposure to 50 Hz magnetic field (MF) affects intracellular calcium ([Ca2+]i). We employed flow cytometry for real-time detection of possible changes in [Ca2+]i in a large number of cells. A solenoid coil for vertical MF exposure and a multiple-loop square-coil for horizontal MF were utilized. In the laboratory, background 50 Hz MF was less than 0.08 microT when all necessary equipment was powered. Rat thymocytes were exposed to 0.1 mT horizontal or vertical field, or to 0.14 mT circularly polarized field for 30 min; the effects of consecutive exposures to vertical and horizontal MFs, or vice versa, for 20 min each also were examined. In addition, intact thymocytes or lectin-activated thymocytes, splenocytes and peripheral blood lymphocytes were exposed to the 5 mT vertical field for 30 min. In all these experiments, no alteration in [Ca2+]i was evident. As a positive control, a calcium ionophore always was added to the medium following MF exposure to verify that the cells were capable of increasing [Ca2+]i and the system would record the response. The data indicate that MF exposure had no effect on [Ca2+]i under any of the conditions examined.

Animals↗

[Immunohistochemical studies on factors involved in after cataract].

In this study, lenses of autopsy eyeballs, anterior capsules including lens epithelium taken during operation for cortical cataract, after cataract tissue obtained at the time of operation, and Elschnig's pearles and Soemmerring's ring from autopsy eye-balls were examined for a variety of factors, such as growth factors, cytokines, bioactive substance factors, cytoskeleton proteins and extracellular matrices by immunocytohistochemistry. Preoperative lens epithelium expressed epidermal growth factor (EGF), EGF-receptor (R), fibroblast growth factor (FGF), FGF-R, interleukin (IL)-1-RII, tumor necrosis factor-alpha (TNF-alpha), plasminogen activator inhibitor type-1 (PAI-1), keratin and laminine. In addition to the above factors, opacified fibrous capsule in after cataract expressed transforming growth factor-beta (TGF-beta), insulin-like growth factor-II (IGF-II), platelet derived growth factor-AB (PDGF-AB), IL-6, prostaglandin-E2 (PG-E2), alpha smooth muscle actin, fibronectin, and I and III to VI type collagen. Elschnig's pearls expressed FGF-R, TNF-alpha, and laminin. Soemmerring's ring expressed EGF, FGF, FGF-R, IL-1-RII, keratin, tissue-PA, and PAI-1.

Cataract↗

Endoscopic ultrasonography and endoscopy for staging depth of invasion in early gastric cancer: a pilot study.

BACKGROUND: We compared the accuracy of endoscopic ultrasonography (EUS) for staging depth of invasion of early gastric cancer with that of conventional endoscopy. PATIENTS AND METHODS: We assessed the depth of invasion of 108 lesions (104 patients) using EUS with a thin 20 MHz probe and compared the results with those of conventional endoscopy and of histologic examination of endoscopically or surgically resected specimens. RESULTS: The overall accuracy rates for staging depth of invasion for conventional endoscopy and EUS were 72.2% and 64.8%, respectively. Lesions that were classified as limited to the mucosa on both conventional endoscopy and EUS were very likely (92.2%) to be limited to the mucosa on histologic examination. The rates for understaging and overstaging were 16.7% and 11.1%, respectively, for conventional endoscopy; and 7.4% and 24.1%, respectively, for EUS. The highest rate for understaging based on conventional endoscopy occurred for lesions in the gastric body (including cardia, 23.9%). CONCLUSIONS: EUS appears to be useful in combination with conventional endoscopy for staging depth of invasion of early gastric cancer. In particular, the two techniques in tandem may accurately predict that a lesion is limited to the mucosa, and EUS may be useful to overcome the potential for understaging by conventional endoscopy, particularly in the gastric body.

Adult↗

Therapeutic results of endoscopic variceal ligation for acute bleeding of oesophageal and gastric varices.

Endoscopic variceal ligation (EVL) using 'O' rings is widely accepted as a treatment of oesophageal varices that is at least as effective as endoscopic injection sclerotherapy but which produces fewer complications. Endoscopic variceal ligation using detachable snares has attracted attention as a safe and easy method of endoscopic treatment for gastric varices. Nineteen patients with acute bleeding from oesophageal or gastric varices were treated in the present study. Of these, 14 patients were treated with EVL using 'O' rings and five patients were treated with EVL using detachable snares and the treatment results were evaluated. Haemostasis was achieved in all patients. No serious complications of the procedures were observed. However, recurrences and rebleeding were observed in some patients during the maximum follow-up period of 24 months. Endoscopic variceal ligation using 'O' rings and detachable snares is useful for achieving haemostasis in cases of acute bleeding from oesophageal or gastric varices. However, additional endoscopic sclerotherapy may be needed to eliminate the variceal feeding vessels to further improve the long-term prognosis of these patients.

Acute Disease↗

Effects of mucin ophthalmic solution on epithelial wound healing in rabbit cornea.

To test the hypothesis that a mucin ophthalmic solution could accelerate the healing of corneal epithelium, we conducted a study in rabbits using an ophthalmic solution containing mucin extracted from bovine submaxillary gland. The corneas of rabbits were abraded with a razor blade in the central portion over an area demarcated with a 7-mm trephine. Mucin-containing eye drops were instilled into the right eye 4 times a day for 3 days, and the vehicle was instilled into the left eye. After enucleation, the eyes were observed by scanning and transmission electron microscopy as well as light microscopy. Mucin-containing eye drops were shown to reduce the epithelial defect area more rapidly than the vehicle. Thus, the eye drops accelerated corneal epithelial wound healing.

Animals↗

Endoscopic ultrasonography of superficial esophageal cancers using a thin ultrasound probe system equipped with switchable radial and linear scanning modes.

BACKGROUND: Detailed information on the depth of invasion of superficial esophageal cancer is required for endoscopic mucosal resection. As a pretherapeutic diagnostic procedure, endoscopic ultrasonography using conventional 7.5 MHz systems has been ineffective at providing sufficient details. A newly developed, thin ultrasound probe system provides both radial and linear scanning for evaluation of superficial esophageal cancer. METHODS: Endoscopic ultrasonography was performed in 16 patients using a switchable probe driven at 20 MHz. Seventeen lesions of superficial esophageal cancer were evaluated for depth of invasion to discriminate mucosal from submucosal penetration. RESULTS: The overall accuracy of staging was 64.7%. In all six errors, mucosal cancers were overstaged as submucosal invasion. The diagnostic accuracy was 80% when the muscularis mucosae was visualized. CONCLUSION: A 20 MHz linear-radial switchable probe is a useful new method in the staging of superficial esophageal cancer.

Aged↗

Horizontal or vertical 50-Hz, 1-microT magnetic fields have no effect on pineal gland or plasma melatonin concentration of albino rats.

Three experiments were carried out on male Wistar-King rats to determine if 6 weeks of exposure to horizontally- or vertically-oriented 1-microT, 50-Hz magnetic fields suppresses melatonin content in plasma and pineal gland, as does 6 weeks of exposure to circularly-polarized, 50-Hz, 1-microT magnetic fields. In each experiment, a concurrent sham-exposed control group was exposed to a stray field of 0.02 microT. In addition, a separate control experiment was completed between the horizontal and vertical field experiments in which cage-controls were housed in the exposure facility for 6 weeks without activation of the magnetic field coils. Subjects were sacrificed at 12:00 or at 24:00 h for collection of plasma and pineal gland; melatonin was determined by radioimmunoassay. In contrast to the results of experiments with rotating-vector magnetic fields, there were no significant differences among 1-microT, 0.02-microT and control groups in melatonin concentration of pineal gland or plasma.

Animals↗

Circularly polarized 50-Hz magnetic field exposure reduces pineal gland and blood melatonin concentrations of Long-Evans rats.

In order to determine if pigmented rats also exhibit melatonin suppression like that described for albino rats exposed to circularly polarized, 50-Hz, 1-muT magnetic fields for 6 weeks, two experiments were conducted with Long-Evans rats. The field-exposed experimental group received circularly polarized, 50-Hz, 1-muT magnetic fields for 6 weeks, the concurrent sham-exposed control group was exposed to the stray field of 0.02 muT. In addition, prior to the exposure experiment, two cage-control groups were placed in the facility for 6 weeks without activation of the 50-Hz magnetic field generation apparatus. Rats were sacrificed at 12.00 and at 24.00 h for collection of plasma and pineal gland: melatonin was determined by radioimmunoassay. Significant reductions of plasma and pineal gland melatonin contents were observed at 0.02 muT as compared to the control values, and a further reduction was observed at 1 muT. As do albino rats, pigmented rats rats also exhibit melatonin suppression when exposed to time-varying magnetic fields.

Animals↗

Recovery of nocturnal melatonin concentration takes place within one week following cessation of 50 Hz circularly polarized magnetic field exposure for six weeks.

In our earlier paper [Kato et al. (1993): Bioelectromagnetics 14:97-106], melatonin concentration in pineal gland and blood was reported to be suppressed after exposure to a circularly polarized 50 Hz magnetic field for 6 weeks. In the present series of experiments, we investigated the time course of recovery after cessation of the exposure. Rats were exposed to a circularly polarized 50 Hz magnetic field at 1 microT for 6 weeks, and the melatonin concentration of blood of separate groups was determined at the end of the exposure and at 1 week and 4 weeks following cessation of exposure. Nocturnal melatonin concentration was reduced (P < 0.05) after 6 weeks of exposure. Melatonin concentration at 1 week following cessation of exposure was normal, and no further change was observed 4 weeks later.

Animals↗

Circularly polarized, sinusoidal, 50 Hz magnetic field exposure does not influence plasma testosterone levels of rats.

We exposed rats to circularly polarized 50 Hz magnetic fields to determine if plasma testosterone concentration was affected. Previous experiments indicate that magnetic fields suppress the nighttime rise in melatonin, suggesting that other neuroendocrine changes might occur as well. Male Wistar-King rats were exposed almost continuously for 6 weeks to magnetic flux densities of 1, 5, or 50 microT. Blood samples were obtained by decapitation at 12:00 h and 24:00 h. Plasma testosterone concentration showed a significant day-night difference, with a higher level at 12:00 h when studied in July and December, but night difference, with a higher level at 12:00 h when studied in July and December, but the day-night difference disappeared when concentrations were studied in April. In three experiments, magnetic field exposure had no statistically significant effect on plasma testosterone levels compared with the sham-exposed groups. These findings indicate that 6 weeks of nearly continuous exposure to circularly polarized, 50 Hz magnetic fields did not change plasma testosterone concentration in rats.

Animals↗

Abducent nerve paralysis during interferon alpha-2a therapy in a case of chronic active hepatitis C.

A 59-year-old woman with chronic active hepatitis C was treated with recombinant human interferon alpha-2a. After three days of administration, the patient complained of diplopia with dizziness and head heaviness. Ophthalmic examinations revealed a disturbance of the movement of left eye ball to the outer side without any other neurological signs. The diplopia, which was diagnosed as abducent nerve paralysis, improved rapidly and reversed at about 6 weeks after discontinuation of interferon and during infusion of hydrocortisone. To our knowledge, this is the first report of abducent nerve paralysis associated with alpha-2a interferon.

Abducens Nerve↗

Effects of exposure to a circularly polarized 50-Hz magnetic field on plasma and pineal melatonin levels in rats.

We sought to determine whether a 6-week exposure to a 50-Hz rotating magnetic field influences melatonin synthesis by 11-18 week-old Wistar-King male rats. Rats were exposed continuously to a rotating magnetic field at 1, 5, 50, or 250 microT (spatial vector rms) for 6 weeks, except for twice-weekly breaks of about 2 h for cleaning of cages and feeding. The rats were housed in exposure and sham-exposure facilities, which were located in the same room, under a 12:12 light-dark photoperiod (lights on at 06:00 h). The room was constantly illuminated by 4 small, dim red lights (< 0.07 lux in dark period). Levels of plasma and pineal gland melatonin were determined by radioimmunoassay. A significant decrease of melatonin was observed between the control group and groups exposed to a magnetic field at a flux density in excess of 1 microT during the night time, but no statistical differences were found among the exposed groups. These results indicate that subchronic exposure of albino rats to a 50-Hz rotating magnetic field influences melatonin production and secretion by the pineal gland.

Animals↗

50-Hz magnetic field exposure system for small animals.

The design, construction, and results of evaluation of an animal-exposure system for the study of biological effects of extremely low frequency (ELF) magnetic fields are described. The system uses a square coil arrangement based on a modification of the Helmholtz coil. Due to the cubic configuration of this exposure system, horizontal and vertical magnetic fields as high as 0.3 mT can be generated. Circularly polarized magnetic fields can also be generated by changing the current and phase difference between two sets of coils. Tests were made for uniformity of the magnetic field, stray fields, sham-exposure ratio of stray field, changes of temperature and humidity, light intensity and distribution inside the animal-housing space, and noise due to air-conditioning equipment. Variation of the magnetic field was less than 2% inside the animal housing. The stray-field level inside the sham-exposure system is less than 2% of experimental exposure levels. The system can be used for simultaneous exposure of 48 rats (2 to a cage) or 96 mice (4 to a cage).

Animals↗

Effect of magnetic field on pineal gland volume and pinealocyte size in the rat.

Light microscopic observations on the superficial pineal gland of Wistar-King rats were made to examine whether or not pineal volume and pinealocyte size, expressed as nuclear density, at daytime or nighttime are affected by long-term exposure to 50 Hz rotating magnetic field (MF) at 5.0 microT. Determinations of pineal volume and pinealocyte size were repeated twice (April and October) during the year. Size of pinealocytes in MF-exposed and sham-exposed rats exhibited, in addition to the difference between peripheral and central regions, regional differences in a proximodistal direction; pinealocytes in the distal and middle-peripheral regions were usually larger than those in the proximal and middle-central regions at daytime or nighttime. In October, distal and proximal pinealocytes showed significant day-night changes in size in sham-exposed rats, but not in MF-exposed animals. The situations in the two groups were almost reversed in April. Significant day-night differences were scarcely found in pinealocyte size in the middle region in the two groups. Throughout the study, pineal volume and pinealocyte size in each region were generally the same between MF-exposed and sham-exposed rats at daytime or nighttime. The results suggest that pinealocytes in the distal and proximal regions, but not those in the middle region, are affected by MF-exposure; day-night differences in sizes of distal and proximal pinealocytes appear in April and disappear in October under the influence of MF. MF may exert an effect on mechanisms controlling day-night rhythms of pinealocyte size in the rat.

Animals↗

Ultrastructural study of adsorbed protein on extracted intraocular lenses.

A comparative study was made of 33 explanted intraocular lenses (IOL) by stereomicroscope, light microscope, phase-contrast microscope, scanning electron microscope and transmission electron microscope. The materials of the extracted lenses were polymethylmethacrylate (PMMA), silicone, polyhydroxyethylmethacrylate (PHEMA) and coated PMMA. The implanted period varied between 3 days and 88 months. An ultrathin membrane-like structure composed of fine, granular material, 0.01 to 0.08 microns thick, that covered the entire explanted IOL surface was observed regardless of the implant period and kind of IOL. The structure was determined to be a layer of adsorbed protein since it showed a positive reaction to protein stainings such as Ponceau 3R, nigrosine or ruthenium red. No membranous structure or cellular deposit could be seen on the surface of the unused PMMA IOL which served as a control.

Adsorption↗