PubMed Health⌕ Search

Biomedical subjects

T Sieber

Publications and source records attributed to T Sieber.

7 recordsLinked to original sources

"Safe" Coulomb excitation of 30Mg.

We report on the first radioactive beam experiment performed at the recently commissioned REX-ISOLDE facility at CERN in conjunction with the highly efficient gamma spectrometer MINIBALL. Using 30Mg ions accelerated to an energy of 2.25 MeV/u together with a thin (nat)Ni target, Coulomb excitation of the first excited 2+ states of the projectile and target nuclei well below the Coulomb barrier was observed. From the measured relative deexcitation gamma-ray yields the B(E2;0(+)gs-->2(+)1) value of 30Mg was determined to be 241(31)e2 fm4. Our result is lower than values obtained at projectile fragmentation facilities using the intermediate-energy Coulomb excitation method, and confirms the theoretical conjecture that the neutron-rich magnesium isotope 30Mg resides outside the "island of inversion."

Journal Article↗

Patient satisfaction with anaesthesia care: development of a psychometric questionnaire and benchmarking among six hospitals in Switzerland and Austria.

BACKGROUND: We describe the development and comparison of a psychometric questionnaire on patient satisfaction with anaesthesia care among six hospitals. METHODS: We used a rigorous protocol: generation of items, construction of the pilot questionnaire, pilot study, statistical analysis (construct validity, factor analysis, reliability analysis), compilation of the final questionnaire, main study, repeated analysis of construct validity and reliability. We compared the mean total problem score and the scores for the dimensions: 'Information/Involvement in decision-making', and 'Continuity of personal care by anaesthetist'. The influence of potential confounding variables was tested (multiple linear regression). RESULTS: The average problem score from all hospitals was 18.6%. Most problems are mentioned in the dimensions 'Information/Involvement in decision-making' (mean problem score: 30.9%) and 'Continuity of personal care by anaesthetist' (mean problem score: 32.2%). The overall assessment of the quality of anaesthesia care was good to excellent in 98.7% of cases. The most important dimension was 'Information/Involvement in decision-making'. The mean total problem score was significantly lower for two hospitals than the total mean for all hospitals (significantly higher at two hospitals) (P<0.05). Amongst the confounding variables considered, age, sex, subjective state of health, type of anaesthesia and level of education had an influence on the total problem score and the two dimensions mentioned. There were only marginal differences with and without the influence of the confounding variables for the different hospitals. CONCLUSIONS: A psychometric questionnaire on patient satisfaction with anaesthesia care must cover areas such as patient information, involvement in decision-making, and contact with the anaesthetist. The assessment using summed scores for dimensions is more informative than a global summed rating. There were significant differences between hospitals. Moreover, the high problem scores indicate a great potential for improvement at all hospitals.

Adolescent↗

[Snakebite---intoxication by cobra venom].

A private reptile breeder who handled exotic snakes was bitten by a Cobra near his ear. An ambulance was immediately called and the patient was transferred under unstable hemodynamic conditions to the nearest major hospital. During transport the patient had to undergo cardiopulmonary resuscitation. In the hospital, his status again deteriorated and he was intubated at a Glasgow coma scale of 5 and vasoactive medications were given. The patient was transferred by helicopter to a university hospital, where several doses of antivenom were given. After 4 days of deep coma the patient regained consciousness and spontaneous respiration and was extubated. Around the location of the bite wound angioedema and local necrosis developed. Surgical treatment of the wound was not necessary and 8 days after the incident the patient was fully recovered and was discharged from the hospital.

Angioedema↗

Artifact-tolerant controllers for automatic drug delivery in anesthesia.

This article presents a method for treating measurement artifacts in model-based control systems. A nonlinear modification to the usual observer structure is introduced to prevent the measurement artifacts from winding up the controller states. It is shown how stability of the closed loop system can be analyzed and an example of a successful application in a clinical study is provided.

Algorithms↗

Intra- and postoperative quality control in minimally invasive direct coronary artery bypass (MIDCAB) surgery.

The introduction of new techniques allowing direct coronary artery revascularisation without sternotomy and extracorporeal circulation--called Minimally (or less) Invasive Direct Coronary Artery Bypass grafting (MIDCAB)--has opened up interesting perspectives for the treatment of patients with limited coronary artery disease. However, like any newer surgical technique, this approach to myocardial revascularisation requires a critical appreciation of the results which may be obtained; when introducing the MIDCAB technique in our institution we developed a quality control protocol based on intraoperative as well as early and late postoperative parameters. This protocol is designed to detect every significant adverse event, exercise capacity and quality of life of our patients. Moreover, several invasive parameters have to be recorded in the protocol, such as intraoperative flow in the internal mammary artery conduit, the angiographic verification of anastomotic patency at one-year follow-up and determination of coronary flow reserve. The results of the first 5 patients observed up to one year postoperatively are presented: all anastomoses were patent and the flow within the internal mammary artery was 69 +/- 40 ml/min at one-year follow-up angiography; this compares very favourably with the flow measured at the end of the operation, which was 31 +/- 8 ml/min. This demonstrates very clearly that internal mammary artery flow is recruitable and usually significantly increases within the first months postoperatively. Coronary flow reserve was 3.4 +/- 1.1 (normal value > 2.5). The results obtained in this pilot study, which was designed to establish a quality control protocol, are very satisfactory and confirm previous experience that this technique may be offered to selected patients with appropriate coronary anatomy.

Coronary Artery Bypass↗

Left ventricular regional wall motion and haemodynamic changes following bolus administration of pipecuronium or pancuronium to adult patients undergoing coronary artery bypass grafting.

The objective of this study was to compare the haemodynamic and myocardial effects of pipecuronium and pancuronium in patients undergoing coronary artery bypass grafting (CABG) during benzodiazepine/sufentanil anaesthesia. Twenty-seven ASA III-IV patients received lorazepam (1-3 mg) po and midazolam ( < 0.1 mg.kg-1) i.v. before induction of anaesthesia with sufentanil (3-8 micrograms.kg-1) was administered to facilitate tracheal intubation. According to random allocation, each patient received either pipecuronium (150 micrograms.kg-1) or pancuronium (120 micrograms.kg-1) after sternotomy but before heparinization. Mean arterial pressure, central venous pressure (CVP), pulmonary artery pressure (PAP), ST segment position and ECG (leads III, V5, AVF) were monitored continuously throughout the procedure. Thermodilution determinations of CO in triplicate were made immediately before, and at two and five minutes after muscle relaxant administration. Multiplane transoesophageal echocardiography (TEE, midpapillary short axis views of the left ventricle) images were continuously recorded from ten minutes before until ten minutes after muscle relaxant administration and graded by two experienced echocardiographic readers. Heart rate, MAP and CO increased after administration of pancuronium (by 13.6 beats.min-1, 10.8 mmHg and 1.0 L.min-1 respectively) but not after pipecuronium (P < 0.05). Evidence of myocardial ischaemia was not detected in any patients using ECG ST segment analysis or TEE assessment of left ventricular wall motion. We conclude that pancuronium caused increases in HR, MAP and CO but that neither pancuronium nor pipecuronium caused myocardial ischaemia.

Adult↗

Perioperative train-of-four monitoring and residual curarization.

It has been suggested that perioperative train-of-four (TOF) monitoring does not reduce the incidence of postoperative residual curarization (PORC). The purpose of this study was to examine whether the use of tactile assessment of the response of the adductor pollicis to supramaximal TOF stimulation of the ulnar nerve at the wrist during anaesthesia affected the incidence of PORC. Thirty-nine ASA I or II surgical patients were studied during thiopentone/fentanyl N2O/enflurane anaesthesia. Pancuronium (70-100 micrograms.kg-1) was used to facilitate tracheal intubation and additional pancuronium increments used to maintain surgical relaxation. The requirement for incremental doses of pancuronium and adequacy of recovery following reversal were assessed according to random allocation, either with (Group A; n = 20) or without (Group B; n = 19) access to TOF monitoring. Patients in the two groups received neostigmine in similar doses (Group A: 53 micrograms.kg-1 (5.9); Group B: 55 micrograms.kg-1 (5.4)). On arrival of the patient to the recovery area, neuromuscular function was assessed electromyographically (using the Datex NMT 221 to measure TOF ratio) and clinically. The incidence of PORC (TOF ratio < 70%) was greater in Group B (47%) than in Group A (15%) (P = 0.029). We conclude that the use of perioperative TOF monitoring decreases the incidence of pancuronium-induced PORC.

Adult↗