PubMed Health⌕ Search

Biomedical subjects

T Slaton

Publications and source records attributed to T Slaton.

3 recordsLinked to original sources

Extremely low vertical-emittance beam in the accelerator test facility at KEK.

Electron beams with the lowest, normalized transverse emittance recorded so far were produced and confirmed in single-bunch-mode operation of the Accelerator Test Facility at KEK. We established a tuning method of the damping ring which achieves a small vertical dispersion and small x-y orbit coupling. The vertical emittance was less than 1% of the horizontal emittance. At the zero-intensity limit, the vertical normalized emittance was less than 2.8 x 10(-8) rad m at beam energy 1.3 GeV. At high intensity, strong effects of intrabeam scattering were observed, which had been expected in view of the extremely high particle density due to the small transverse emittance.

Journal Article↗

High-gradient millimeter-wave accelerator on a planar dielectric substrate.

We report the first high-gradient studies of a millimeter-wave accelerator, employing for the first time a planar dielectric accelerator, powered by means of a 0.5-A, 300-MeV, 11.424-GHz drive electron beam, synchronous at the 8th harmonic, 91.392 GHz. Embedded in a ring-resonator circuit within the electron beam line vacuum, this structure was operated at 20 MeV/m, with a circulating power of 200 kW, for 2 x 10(5) pulses, with no sign of breakdown, dielectric charging, or other deleterious high-gradient phenomena. We also present the first measurement of the quadrupolar content of an accelerating mode.

Journal Article↗

A performance study of the Loma Linda proton medical accelerator.

More than three years have passed since Loma Linda treated the first cancer patient with the world's first proton accelerator dedicated to radiation therapy. Since that time, over 1000 patients have completed treatments and the facility currently treats more than 45 patients per day. With a typical intensity of 3 x 10(10) protons per pulse and 27 pulses per minute, dose rates of 90-100 cGy/min are easily achieved on a 20-cm diameter field. In most cases, patient treatment times are 2 min, much less than the patient alignment time required before each treatment. Nevertheless, there is considerable medical interest in increasing field sizes up to 40-cm diameter while keeping dose rates high and treatment times low. In this article, beam measurements relevant to intensity studies are presented and possible accelerator modifications for upgrades are proposed. It is shown that nearly all intensity losses can be ascribed to the large momentum spread of the injected beam and occur at or near the injection energy of 2 MeV. The agreement between calculations and measurements appears quite good. In addition, optimum beam characteristics for a new injector are discussed based upon the momentum acceptance and space charge limits of the Loma Linda synchrotron.

Biophysical Phenomena↗