PubMed Health⌕ Search

Biomedical subjects

T Strömberg

Publications and source records attributed to T Strömberg.

At least 37 records · Page 2Linked to original sources

Hand problems in 100 vibration-exposed symptomatic male workers.

Long-term use of hand-held vibrating tools may induce various types of hand problems. One hundred symptomatic men exposed to vibration from such tools were interviewed and examined with special reference to neurosensory and vasospastic problems. Three distinct symptomatic groups were identified: isolated neurosensory symptoms (48%), isolated vasospastic problems (20%), and combined neurosensory and vasospastic problems (32%). Abnormal cold intolerance (pain and coldness without blanching of the fingers on exposure to cold) occurred in 27% of the patients. Neurosensory problems were more predominant than vasospastic ones, especially during the first 20 years of vibration exposure. Of 80 patients with neurosensory symptoms, only 22 had signs of a carpal tunnel syndrome (CTS). It is concluded that vibration-induced neurosensory and vasospastic symptoms can occur separately or together, and that the neurosensory symptoms are often not due to a CTS.

Adult↗

Impaired regeneration in rat sciatic nerves exposed to short-term vibration.

We have studied the effects of vibration on the regeneration capacity of the peripheral nerve. A rat model was used where one hind limb was subjected to vibration of defined magnitude and duration while the contralateral hind limb was not exposed to vibration. Seven days later, the sciatic nerves were transected bilaterally and cross-joined giving the following groups: group A, a proximal vibrated nerve end sutured to a non-vibrated distal nerve end; group B, a non-vibrated proximal nerve end sutured to a distal vibrated nerve end, and group C, non-vibrated proximal nerve end sutured to a non-vibrated distal nerve end. The regeneration distances were measured 3, 6 and 8 days after surgery. The control group showed a normal linear outgrowth. The outgrowth in the two experimental groups was initially not different to controls but later became significantly different, indicating a retardation of outgrowth in these groups. It is concluded that short-term exposure to vibration can impair nerve regeneration after transection and nerve repair.

Animals↗

Clinical management of nonhealing periradicular pathosis. Surgery versus endodontic retreatment.

OBJECTIVES: This prospective randomized study compared the outcome of retreatment and surgical intervention in root canal treated teeth with nonhealing periradicular pathosis. STUDY DESIGN: One such tooth from each of 38 patients was randomly allotted to retreatment or root-end resection and root-end filling. Treatment outcome after 1 year was evaluated and compared clinically and radiographically. RESULTS: The success rate for surgery was higher than for conventional retreatment, but the difference was not statistically significant. CONCLUSIONS: For management of nonhealing periradicular pathosis associated with root canal treated teeth, surgical intervention should be considered as an alternative to retreatment. In cases with a similar prognosis for both modes of treatment, the choice should be governed by consideration of intrinsic and extrinsic factors.

Adult↗

A method for measuring the CO2 dead space volume in facial visors and respiratory protective devices in human subjects.

The external CO2 dead space volume (Vd) in facial visors and respiratory protective devices is difficult, but important, to measure in human subjects. The lack of proper methods for its assessment has hampered the development of standards and the improvement of visor and device design. We have improved and evaluated a method for measuring Vd and the mean inspired fraction of CO2 (FI,CO2) in human subjects wearing facial visors or respiratory protective devices. The method is based on indirect measurements of inspiratory volumes using a calibrated respiratory inductive plethysmograph (RIP), and measurements of FCO2 with a mass spectrometer. The accuracy of the RIP method was assessed in eight subjects and its repeatability was studied during nasal and oral breathing, at rest and after bicycle ergometer work. We related the Vd,RIP results to two known external VdS (with the effective Vd equal to the geometric volume; 15 ml and 320 ml), through which the subjects breathed, using RIP and a pneumotachometer (PTM) simultaneously (Vd,RIP and Vd,PTM). The repeatability of Vd and mean FI,CO2 results was determined from duplicate recordings during the wearing of a welding visor. Initial RIP calibration was accepted if the inspiratory tidal volume error was < or = 10%. This resulted in an acceptable Vd,RIP error (< or = 20%; Vd = 320 ml) in six eight subjects. The validation technique allowed us to separate the Vd,RIP error into a volumetric error and an error related to CO2 measurement. Poor RIP volumetric accuracy over the initial portion of inspiration was detrimental to Vd accuracy. Using the welding visor, Vd and mean FI,CO2 were less at rest than after work and less during nasal breathing than during oral breathing. The intra-individual variability of Vd and mean FI,CO2 were lower during nasal breathing than during oral breathing. To summarize, the improved RIP based method can accurately (< or = 20% error) assess Vd and mean FI,CO2 in facial visors and respiratory protective devices in standardized work situations. A meticulous RIP calibration procedure and repeated validations of RIP volume and CO2 measurement accuracy must, however, be applied.

Adolescent↗

A bioacoustic method for timing of respiration at cardiac investigations.

At cardiac investigations Doppler echocardiography is an established technique for the recording of intracardial and intravascular flow velocities. Transvalvular and venous flows are, however, markedly influenced by respiration. Since the start of inspiration is the important time of reference, accurate recording of the respiratory phase is important when analysing these flow velocities. A bioacoustic technique was therefore adopted to meet this demand and was tested in 10 normal subjects. Oesophageal balloon technique was used as a reference, and the bioacoustic technique was compared with a respiratory inductive plethysmograph. The average delay for the acoustic sensor signal compared to the oesophageal pressure changes was 205 +/- 46 (SD) ms, ranging from 160 to 320 ms for normal breathing, and is comparable to that of the respiratory inductive plethysmograph (210 +/- 90 ms). The bioacoustic technique is easier to apply than the respiratory inductive plethysmograph. The sensitivity to disturbances can be further reduced by signal processing and the method has clinical potential for the future.

Adult↗

A study in vitro of threaded titanium pins used for retrograde obturation of root canals.

The microleakage of four retrograde filling materials was compared in vitro. Fifty-three single rooted teeth were instrumentated and root filled with resin chloroform and gutta-percha. The gutta-percha cones were left extruding from the access opening. All teeth were apicected and retrograde fillings placed. The materials used were a non gamma 2 amalgam (Amalcap), a glass ionomer cement (ChemFil II), threaded titanium pins cemented with a glass ionomer cement (ChemFil II) and identical titanium pins cemented with a silicone material (Adheseal). After removal of the gutta-percha with tweezers, a radioactive isotope solution was placed in the teeth. Extraradicular samples were taken at 3, 7, 28, 77 and 104 days. All retrograde fillings showed some microleakage. The group with titanium pins cemented with silicone showed the least leakage: significantly less than the teeth with glass ionomer cement (P < 0.01) and with amalgam (P < 0.01). No significant differences were found between other groups.

Dental Amalgam↗

Assembly of Atlantic cod (Gadus morhua) brain microtubules at different temperatures: dependency of microtubule-associated proteins is relative to temperature.

Isolated cod (Gadus morhua) brain microtubules were found to have a broad temperature interval for assembly. In contrast to mammalian microtubules they assembled even at as low temperatures as 14 degrees C. Evidence was found that temperature alters the dependency of microtubule-associated proteins (MAPs) for assembly. The assembly was MAPs-dependent at low, but not at higher temperatures. Assembly at +18 degrees C was inhibited by both NaCl and estramustine phosphate. These compounds are well known to inhibit the binding of MAPs to tubulin. At higher temperatures there was no MAPs dependency for assembly, despite that MAPs bound to the microtubules. Cow MAPs had the same effect as cod MAPs, suggesting that despite differences in MAP composition, the effect is not caused by the unusual composition of cod MAPs. The results therefore suggest that these differences in MAPs dependency are due to intrinsic properties of cod tubulin or tubulin-to-tubulin interactions. Small temperature-induced conformational changes of tubulin and a slight enrichment of acetylated and detyrosinated tubulin in microtubules assembled at +30 degrees C as compared to +15 degrees C, were observed. The ability to alter the assembly stimulating effect of MAPs may be important for the cell to regulate microtubule dynamics and stability. In addition, changes in tubulin conformation and composition of tubulin isoforms may reflect adaptations for microtubule assembly at low temperatures.

Animals↗

Neurophysiological investigation of hands damaged by vibration: comparison with idiopathic carpal tunnel syndrome.

Forty-seven men with numbness and paresthesiae in their hands after long-term occupational exposure to vibrating hand-held tools were examined neurophysiologically and clinically. The vibration thresholds of the finger tips were assessed and fractionated neurography of the median nerve motor and sensory fibres carried out. They were compared with control groups of healthy subjects and patients with idiopathic carpal tunnel syndrome. The patients exposed to vibration had major increases in their finger vibration thresholds, shown with both the Goldberg-Lindblom vibrameter and the Lundborg vibrogram. They also had a moderately increased motor distal latency at the wrist, but significantly less than patients with idiopathic carpal tunnel syndrome. Similar changes were seen in the sensory conduction velocities from finger to wrist. Measurement of fractionated conduction velocity across the carpal tunnel showed a bimodal distribution; one group of patients exposed to vibration had a significant reduction in conduction velocity similar to that in the genuine carpal tunnel syndrome, and one group had no localised affection at the carpal tunnel, suggesting more distal dysfunction at the level of palm or finger, or at the receptor level. A careful neurophysiological assessment of these cases is necessary before treatment is planned. It is particularly important to confirm median nerve damage at the wrist level if the carpal tunnel ligament is to be sectioned.

Adult↗

Vibrotactile perception threshold measurements for diagnosis of sensory neuropathy. Description of a reference population.

Recognition of the fact that impairment of the tactile sense may occur independently of other disturbances in the vibration syndrome has rekindled an interest in developing a diagnostic method for early detection of vibration-induced neuropathy. There is also evidence suggesting that vibrotactile measurements represent a valuable diagnostic tool in compressive neuropathies, such as the carpal tunnel syndrome. The method may also become useful for diagnosing sensory neuropathies caused by other factors, such as solvents, pesticides, heavy metals, alcoholism, and diabetes. However, before vibrotactile measurement can be accepted and established as a tool for clinical diagnostic purposes, for screening, and in research, the level and the shape of the normal threshold curve have to be specified. With the purpose of assembling normative data, the vibrotactile perception thresholds (8-500 Hz) of the right index fingertip were measured in 171 healthy males (19-75 years) not exposed to vibration. A Békésy audiometer was modified to operate in combination with a vibration exciter, instead of headphones, at frequencies lower than usual (8-500 Hz). The results showed that the perception thresholds increased from about 100 dB to about 140 dB (rel. 10(-6) m/s2rms) as a function of frequency and age. The frequency-dependent changes were not linear, however, but displayed a peak in sensitivity at 125 Hz. Threshold changes due to aging were most pronounced at the highest frequencies. It is of the utmost importance that these natural changes are taken into account when making comparisons between groups or individuals.

Adult↗

Quantitative radioactive analysis of microleakage of four different retrograde fillings.

Sealing properties of four different retrograde filling materials were investigated in vitro. Radioactive isotopes were applied in the root canal, and leakage into an extraradicular fluid was measured at regular intervals. The method permitted repeated observation of the specimens over prolonged periods of time. Forty single-rooted human teeth were biomechanically instrumented and obturated using calcium-hydroxide paste. Following obturation, an apicectomy was performed and retrograde cavities were filled with four different materials: group 1, non gamma 2 amalgam (Amalcap); group 2, glass ionomer cement (Ketac Silver); group 3, calcium-hydroxide-based root canal sealer (Sealapex); group 4, composite resin (Palfique Light-S). After removal of the calcium hydroxide, the teeth were immersed in a fluid. An isotope solution was then placed in the root canals. Samples were taken from the fluid at 0, 3, 7, 28, 56, 105, 210, 285 and 376 days to determine the radioactivity. It was found that Sealapex and Palfique Light-S showed significantly less leakage than amalgam and glass ionomer cement, which had the highest apical leakage.

Analysis of Variance↗

Vibrotactile function of the hand in compression and vibration-induced neuropathy. Sensibility index--a new measure.

The perception thresholds for vibration stimuli of the hand at seven frequencies (8-500 Hz) were evaluated in 300 patients referred to the Department of Hand Surgery in Malmö during the years 1985-1990 for various types of neuropathy (carpal tunnel syndrome, vibration-induced neuropathy, cervical rhizopathy, brachialgia, ulnar neuropathy, radial tunnel syndrome, and polyneuropathy). A sensibility index was calculated by dividing the integrated area under the obtained vibrogram curve of each object tested (areaT) by that of the corresponding area under a superimposed and age matched reference curve (areaR). Sensibility index of less than 0.8 was regarded as the cut off value. The index and little fingers bilaterally were tested to reflect median and ulnar nerve function. There were considerable variations in patterns of pathology among the various groups of patients. In patients with unilateral carpal tunnel syndrome only 10 patients (23%) had abnormalities limited to one recording, while 21 patients (47%) showed abnormalities in all four recordings. This indicates that an isolated carpal tunnel syndrome may reflect more generalised disease of the peripheral nervous system.

Carpal Tunnel Syndrome↗

Trochanteric fractures--a clinical and radiologic evaluation of McLaughlin, Ender, and Richard's osteosynthesis.

Four hundred and thirty femoral trochanteric fractures operated with nail-plate (McLaughlin), Ender, or sliding screw-plate (Richard) osteosynthesis were followed up radiographically and clinically. For each method of osteosynthesis the initial nail position was correlated to the occurrence of late mechanical complications. Unstable fractures were associated with a higher incidence of one or more clinical complications such as repeated surgery, post-operative death, or increased pain. For Ender osteosynthesis correlations were found between several mechanical and clinical complications, while for Richard's osteosynthesis mechanical complications were significantly correlated to repeated surgery only. McLaughlin and Ender osteosyntheses had a higher incidence of reoperations than Richard's osteosynthesis, whereas the mobility and ADL function were the same at 4 months.

Bone Plates↗

A new principle for assessing vibrotactile sense in vibration-induced neuropathy.

The vibrotactile perception threshold has been evaluated in 20 manual workers not exposed to occupational vibration and in 27 workers using hand-held vibrating tools. Threshold values were evaluated with a Békesy type of vibrometer at frequencies ranging from 8 to 500 Hz. The earliest sign of vibration lesion was a reduction of sensation at frequencies of 125 to 250 Hz, indicating dysfunction in receptors of the fast adapting type II (stage 1 curve), followed in more severe cases by a prominent loss of sensation at all frequencies higher than 65 Hz (stage 2 curve). The stage 3 curve indicated the most severe loss of sensation in which the function of slowly adapting type I receptors, as well as fast adapting type I receptors, was deteriorated; consequently the vibrotactile thresholds at low-, median-, and high-frequency ranges were impaired. The vibrotactile changes corresponded well to numbness and the presence of vibration-induced white finger.

Adolescent↗

Digital vibrogram: a new diagnostic tool for sensory testing in compression neuropathy.

A Békésy audiometer was modified for use in analysis of vibrotactile sensibility of the hand at frequencies ranging from 8 to 500 Hz. In control subjects the "digital vibrogram" has a typical shape, which differs characteristically in patients with carpal tunnel syndrome (CTS). Changes in digital vibrogram usually parallel or precede abnormalities in neurophysiologic tests, and appear long before changes in two-point discrimination (2PD). One-hundred-thirty-two hands of 76 patients diagnosed as having CTS were tested with a vibrometer. Of 113 hands with normal 2PD, the digital vibrogram showed abnormal in 86 cases. Of 19 hands with abnormal 2PD, the digital vibrogram showed abnormal in all but three cases. Twenty-six hands with neurophysiologically normal appearance had abnormal digital vibrogram in 14 cases, while 53 hands neurophysiologically classified as CTS showed abnormal digital vibrogram in 44 cases. It is concluded that the digital vibrogram is a useful tool for early diagnosis of CTS.

Carpal Tunnel Syndrome↗

Histochemical demonstration of acid hydrolase activity in internal dentinal resorption.

The enzymes acid phosphatase (E.C. 3.133) and beta-glucuronidase (E.C. 3.2.1.31) have been demonstrated in dentin-resorbing cells by means of histochemistry. Addition of specific enzyme inhibitros revealed that the acid phosphatase of these cells was sensitive to fluride, copper, and m?OLYBDATE BUT RESISTANT TO Tartrate. The same pattern of enzyme activity has previously been found in bone-resorbing cells.

Acid Phosphatase↗