Development of individual insulin infusion profiles for open loop infusion systems.

A computer controlled syringe-type insulin infusion pump storing up to 254 different infusion rates, eight different meal programs and two different basal rates automatically changeable during 24 h in EPROM was used for insulin infusion applying a wavy step profile. This profile approaching the physiological postprandial insulin secretion of the B-cell was calculated by an algorithm following the biphasic insulin secretion model proposed by E. Cerasi . The computer program for the open loop infusion device simulated the feed-back structure of a closed loop insulin secretion control by an algorithm based upon a theoretical postprandial blood sugar profile. Fifteen unstable juvenile onset insulin requiring diabetics could be well controlled after two to three days of an intravenous open loop insulin infusion program. The programs consisted of two constant basal rates and superimposed wavy step profile programs activated at the beginning of each meal. The preabsorptive bolus or cephalic phase was an additional tool both for improved postprandial blood sugar control and further reduction of insulin consumption. The programmable insulin infusion device proved as a valuable tool for the study of a sophisticated insulin infusion profile suitable as well for open loop as for closed loop insulin infusion systems.

Adult↗

The influence of different generations of computer algorithms on diabetes control.

With all control schedules, the management of diabetes is possible using Skyler's algorithm. In general, those control algorithms which do not allow the individual adaptation to changing conditions lead to overinsulinisation. So-called meal-related algorithms do usually minimise the fluctuations in blood sugar. The introduction of self-adapting algorithms, detecting peripheral insulin resistance, may further improve metabolic diabetes control.

Algorithms↗

Developmental and application of insulin infusion profiles for therapy of type-I diabetics with portable insulin infusion systems.

We studied the insulin requirements of seven insulin-dependent diabetics applying a glucose controlled insulin infusion system. The data were transformed into individually programmed and rectangular profiles. The MAGE, a measure of blood sugar fluctuations, was significantly lower when individually programmed step profiles were used (P less than 0.005) than it was when rectangular profiles were applied: 57.7 +/- 24.8 mg/dl vs 89.0 +/- 42.9 mg/dl. The average of measured blood glucose levels was significantly lower in individually programmed infusion profiles (P less than 0.025). The combination of individually programmed profiles and preprandial insulin bolus significantly reduced the postprandial blood glucose level and increase (P less than 0.001). Our investigations suggest that individually programmed insulin infusion profiles are able to smooth blood glucose fluctuations. When combined with an initial insulin bolus they may lead to a reduced insulin consumption after meals.

Adult↗