PubMed Health⌕ Search

Biomedical subjects

T T Prinzen

Publications and source records attributed to T T Prinzen.

3 recordsLinked to original sources

Noise reduction in estimating cardiac deformation from marker tracks.

Deformation of the cardiac wall is measured by using optical or radiopaque markers attached to the wall. When digitized images are used, the accuracy of the measurement of a marker position is limited by pixel resolution and the size of the marker. The spatial accuracy is improved by singular value decomposition (SVD) filtering. This filtering procedure is based on the assumption that displacements of markers are mutually related because they are embedded in a common continuum. In a computer stimulation with 48 markers in 51 video frames, the accuracy of the measurement of a marker position improved from 0.14 to 0.045 (SD) pixel. In an open-chest animal experiment, with markers on the surface of the heart, the deformation patterns were extracted more clearly using SVD filtering, while mutually related high-frequency components were not suppressed. In a 50-frame sequence of 256 X 256 video images of a 45 mm X 35 mm deforming surface with 50 markers of 8 pixels in diameter, the marker position resolution improves from 0.1 to 0.03 (SD) pixel (6 microns). Strain is determined with an accuracy of 0.002 over a distance of 30 pixels (6 mm).

Animals↗

Mapping of epicardial deformation using a video processing technique.

A method has been developed to measure deformation of the canine epicardium during the cardiac cycle simultaneously in a number (eight) of small regions (1 X 1 cm2). Approximately 50 white markers (diameter 1.5 mm) are attached to the epicardium and their motion is recorded on tape by a video camera. Marker positions are detected by computer processing of the digitized images. In each region the three deformation parameters are calculated from the displacements of all markers in that region by means of a least-squares criterium. In the experimental situation in the center of the area of the epicardium analyzed the accuracy of measuring circumferential strain, base-to-apex strain and shear is +/- 0.005, +/- 0.005 and +/- 0.002 rad, respectively. The method has been applied in an experiment in which local ischemia of the left ventricular wall was induced by occluding the anterior descending branch of the left coronary artery. Healthy and ischemic regions could clearly be distinguished by the differences in deformation.

Animals↗