PubMed Health⌕ Search

Biomedical subjects

T Takatsu

Publications and source records attributed to T Takatsu.

At least 19 recordsLinked to original sources

Doxorubicin overproduction in Streptomyces peucetius: cloning and characterization of the dnrU ketoreductase and dnrV genes and the doxA cytochrome P-450 hydroxylase gene.

Doxorubicin-overproducing strains of Streptomyces peucetius ATCC 29050 can be obtained through manipulation of the genes in the region of the doxorubicin (DXR) gene cluster that contains dpsH, the dpsG polyketide synthase gene, the putative dnrU ketoreductase gene, dnrV, and the doxA cytochrome P-450 gene. These five genes were characterized by sequence analysis, and the effects of replacing dnrU, dnrV, doxA, or dpsH with mutant alleles and of doxA overexpression on the production of the principal anthracycline metabolites of S. peucetius were studied. The exact roles of dpsH and dnrV could not be established, although dnrV is implicated in the enzymatic reactions catalyzed by DoxA, but dnrU appears to encode a ketoreductase specific for the C-13 carbonyl of daunorubicin (DNR) and DXR or their biosynthetic precursors. The highest DXR titers were obtained in a dnrX dnrU (N. Lomovskaya, Y. Doi-Katayama, S. Filippini, C. Nastro, L. Fonstein, M. Gallo, A. L. Colombo, and C. R. Hutchinson, J. Bacteriol. 180:2379-2386, 1998) double mutant and a dnrX dnrU dnrH (C. Scotti and C. R. Hutchinson, J. Bacteriol. 178:7316-7321, 1996) triple mutant. Overexpression of doxA in a doxA::aphII mutant resulted in the accumulation of DXR precursors instead of in a notable increase in DXR production. In contrast, overexpression of dnrV and doxA jointly in the dnrX dnrU double mutant or the dnrX dnrU dnrH triple mutant increased the DXR titer 36 to 86%.

Acyl Carrier Protein↗

Radiological study of cervical ossification of the posterior longitudinal ligament.

The rate of progression of cervical ossification of the posterior longitudinal ligament (OPLL) was radiologically studied during a 3-year period in three patient populations: (a) after laminoplasty (25 patients), (b) after laminectomy (16 patients), and (c) in patients who were managed without surgery (56 patients). There appeared to be no significant difference between these two surgical procedures in postoperative progression of OPLL. When progression of OPLL was compared between patients treated surgically and nonsurgically, posterior surgery accelerated progression of OPLL.

Adult↗

Analysis of rising from a chair after total knee arthroplasty.

The relationship between the range of motion following total knee arthroplasty (TKA) and the height of chairs when rising from a seated position was analyzed. Forty-six TKA subjects were evaluated; 16 had osteoarthritis, 30 had rheumatoid arthritis. Subjects were divided into two groups based on their degree of knee flexion (average: 96.0 degrees; range: 75 degrees to 135 degrees; group 1 contained 24 subjects with < 100 degrees of flexion and group 2 contained 22 subjects with > 100 degrees of flexion) in order to evaluate the acceptable knee flexion angle required for comfortably rising from a chair. To evaluate the flexion-extension angle of the knee and hip joints, three goniometers, a large reaction force plate, and a switch sensor on the chair surface to detect the initiation of rising were used. One chair had a height equal to the subjects' lower leg length, while the height of the second chair was 120% of the subjects' lower leg length. Analysis showed that TKA patients with less knee flexion (< 100 degrees) required a high angular velocity of the hip and excessive swing velocity to lift the trunk forward than did those with a larger degree of knee flexion (> 100 degrees). We concluded that a minimum of 100 degrees of postoperative flexion is desired and that a higher chair is more suitable for TKA patients.

Activities of Daily Living↗

The function of posterior tilt of the tibial component following posterior cruciate ligament-retaining total knee arthroplasty.

To increase the range of motion in the knee, posterior cruciate ligament-retaining total knee arthroplasty (TKA), which has a roll back (RB) mechanism, is used. The roll back mechanism is the complex movement of the femoral condyles relative to the tibial plateau, which results in translation of the tibiofemoral contact point posteriorly as the knee is flexed. This study was undertaken to assess the function of the posterior cruciate ligament (PCL) and posterior tibial tilt following PCL-retaining TKA. Eleven fresh-frozen cadaveric normal lower extremity specimens (average age: 75.4 years; range: 69 to 88 years) were obtained for this study. The test was performed on a loading frame after specimen preparation. The calcaneal bone was fixed on the rigid frame. A load of 9.5 kg was applied perpendicularly by the moving frame to femoral head through four casters. PCL strain and RB were measured before and following TKA by changing the posterior tilt of tibial component and the external rotation of femoral component. PCL strain at 105 degrees flexion in the 0 degree posterior tilt group (3.3% +/- 2.4%) was decreased in the 10 degrees posterior tilt group (0.6% +/- 0.5%), and this decrease was statistically significant (p < 0.05). RB was measured as anterior-posterior translation by using an arthroscopic probe. After TKA, RB was decreased in the medial compartment but was increased in the lateral component. These different movements of the tibiofemoral contact points consequently caused rotation in the flexion position. Posterior tilt of the tibial component decreased the efficiency of the PCL's function. Retaining the PCL physically is not the same as preserving the function of the PCL because of the lack of the ACL, the change of the joint line, the differences in articular geometry, and the balance of the ligaments.

Aged↗

A simple method of intraoperative limb length measurement in total hip arthroplasty.

The equalization of leg-length discrepancy during total hip arthroplasty can be achieved through the use of a simple measuring device, the Calipers Dual Pin Retractor. During total hip arthroplasty a stable reference point must be established to determine leg-length changes. The Calipers Dual Pin Retractor was developed to establish a fixed point on the pelvis, which would remain constant throughout the procedure, from which the distance to the trochanteric area could be measured prior to the dislocation of the hip. This measurement is then used to aid in the proper placement of the femoral components.

Anthropometry↗

Morphological analysis of the cervical spinal canal, dural tube and spinal cord in normal individuals using CT myelography.

To verify the conventional concept of "developmental stenosis of the cervical spinal canal", we performed a morphological analysis of the relations of the cervical spinal canal, dural tube and spinal cord in normal individuals. The sagittal diameter, area and circularity of the three structures, and the dispersion of each parameter, were examined on axial sections of CT myelograms of 36 normal subjects. The spinal canal was narrowest at C4, followed by C5, while the spinal cord was largest at C4/5. The area and circularity of the cervical spinal cord were not significantly correlated with any parameter of the spinal canal nor with the sagittal diameter and area of the dural tube at any level examined, and the spinal cord showed less individual variation than the bony canal. Compression of the spinal cord might be expected whenever the sagittal diameter of the spinal canal is below the lower limit of normal, that is about 12 mm on plain radiographs. Thus, we concluded that the concept of "developmental stenosis of the cervical spinal canal" was reasonable and acceptable.

Adolescent↗

Long-term follow-up review of suspension laminotomy for cervical compression myelopathy.

This study compared the long-term outcome of cervical spondylotic myelopathy (CSM) with that of the ossification of the posterior longitudinal ligament of the cervical spine (OPLL) after suspension laminotomy, which was developed in the authors' clinic. Seventy-six patients who received follow-up care for more than 5 years were available for analysis. The duration of the follow-up period averaged 97.8 months (range 61-160 months). Radiological and neurological analyses were performed in these 76 patients (50 with CSM and 26 with OPLL). There were no differences in sex, age, follow-up period, and preoperative neurological status between the two groups. In the quantitative study of the dural configuration, 43 patients (86%) with CSM and 17 patients (65.4%) with OPLL attained complete decompression 1 month after surgery. At long-term follow-up review, complete decompression was maintained in 42 patients (84%) with CSM but in only seven patients (26.9%) with OPLL. The neurological evaluation improved markedly at early follow up in both groups but declined insignificantly at the last follow-up review, particularly in the OPLL group. Of 12 patients (24%) with CSM and 10 patients (38.5%) with OPLL whose neurological recovery grades later deteriorated, four (8%) with CSM and nine (34.6%) with OPLL demonstrated reconstriction causing spinal cord compression at long-term follow-up review. For the remaining eight patients (16%) with CSM, who were older than 70 years on average at last follow-up review, no radiological explanation was found. These long-term results indicate that OPLL does not resolve as well as CSM after suspension laminotomy; they both may have late deterioration due to reconstriction that occurs occasionally in CSM and frequently in OPLL.

Adult↗

A-72363 A-1, A-2 and C, novel heparanase inhibitors from Streptomyces nobilis SANK 60192. I. Taxonomy of producing organism, fermentation, isolation and structure elucidation.

Novel heparanse inhibitors, A72363 A-1, A-2, and C, were isolated from the culture filtrate of Streptomyces nobilis SANK 60192 by column chromatography on various resinous adsorbents, followed by preparative anion exchange HPLC. Spectroscopic studies revealed that they are diastereomers of siastatin B, a neuraminidase inhibitor.

Enzyme Inhibitors↗

A-72363 A-1, A-2, and C, novel heparanase inhibitors from Streptomyces nobilis SANK 60192, II. Biological activities.

Inhibitory activities of A-72363 A-1, A-2 and C, the diastereomers of a neuraminidase inhibitor siastatin B, against various glycosidases were tested in comparison to siastatin B. Despite these compounds differing only in their configuration, each compound showed strikingly different specificities towards the various glycosidases tested. A-72363 C inhibited bovine liver beta-glucuronidase and tumor cell heparanase with IC50 values of 1.6 microM and 12 microM, respectively.

Animals↗

Shear and tensile bond testing for resin cement evaluation.

OBJECTIVES: The aim of this study was to compare the tensile and shear bond strengths of one experimental and four commercially available resin cements following the ISO document TR 110405 for bond measurement. METHODS: Tensile and shear bond tests were performed using bovine enamel and dentin as the tooth substrate with each of the resin cements. Resin composite rods were cemented to the prepared tooth surfaces. The bond strengths were obtained 24 h after cementation, and mode of failure was classified after fracture of the bonds, both visually and by SEM observation. RESULTS: Significant differences existed between the two bond test methods for all materials with enamel and three of the five cements when bonded to dentin. The shear test results were always the higher of the two test methods. Mode of fracture varied little for the visual classification, but the morphology from SEM observations showed considerable differences. SIGNIFICANCE: Although there are deficiencies in the current test methods these may be outweighed by substrate variables. A test model should be designed to determine which stresses, tensile or shear, are the greatest for different types of restorations. With this information, the type of test selected could provide appropriate information before clinical trials are commenced.

Aminosalicylic Acids↗

Effect of air-powder polishing on adhesion of bonding systems to tooth substrates.

OBJECTIVES: The air-powder polisher was introduced to provide a method to quickly remove stains and plaque. The purpose of this study was to evaluate what effect preparing teeth with an air-powder polisher (Air-flow 2, Shofu) has on bonding to enamel and dentin substrates. METHODS: The bonding systems used in this study were one-step etching/priming systems (KBT-5, Kanebo; and Clearfil Liner Bond II, Kuraray) and a two-step etching/priming system (Superbond D-Liner Plus, Sun Medical). Bovine enamel and dentin surfaces were prepared and finished with 600-grit silicon carbide paper. Then the surfaces were either not treated (control) or air-powder polished for 15 s. A 4-mm bonding area was demarcated, and the tooth substrates were bonded with the three bonding systems according to the manufacturers' instructions. Tensile bond strengths were measured 24 h after storage in water at 37 degrees C. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) analyses were performed on air-powder polished specimens to determine changes in the surface morphology and detect residual material from the air-powder polisher. SEM and transmission electron microscopic (TEM) observations of the interface between the bonding resins and dentin were performed to detect variations in the hybrid layers of the control and treated specimens. RESULTS: The results indicated that air-powder polishing did not influence the tensile bond strength to enamel, but adversely affected the tensile bond strength to dentin for the one-step systems, but not for the two-step system. Changes to the enamel surface after air-powder polishing were minimal, but an increase in surface roughness and complete removal of the smear layer were observed on dentin. SEM and TEM observations of the resin/dentin interface suggested that the air-powder polisher might cause superficial maceration of the collagen fibers on the dentin surface. This change may have decreased the ability of the etching/priming agents and bonding resin to penetrate into the dentin, which would have resulted in a poor quality hybrid layer. SIGNIFICANCE: For those systems that contain only an acidic primer for dentin conditioning, the use of air-powder polishing for surface preparation prior to restoration of dentin margin cavities is contraindicated because of the loss of reliable bonding.

Air Pressure↗

Influence of temperature and relative humidity on early bond strengths to dentine.

The effect of temperature and relative humidity (RH) on the early tensile bond strengths to bovine dentine of two bonding systems (Liner Bond System, and Scotchbond Multi-purpose), and an experimental system (KB-110) were tested. Two environmental conditions, room temperature (23 degrees C/50% RH) and oral temperature (30 degrees C/80% RH), were used in a controlled temperature and humidity chamber. Bond strengths were recorded immediately after, 10 min and 24 h following light curing. The tensile bond strengths did not vary between the two test conditions, but the mode of fracture was observed to change. The 30 degrees C/80% RH condition exhibited a slightly greater degree of adhesive type failures compared with the 23 degrees C/50% RH group. This was particularly so for the experimental system, indicating that different bonding systems may be more or less sensitive to changes in RH and temperature. Failures occurred partially or totally within the resin composite at the early test times, and it was concluded that the bond strengths of the systems tested tended to exceed the early cohesive strengths of the resin composite.

Adhesiveness↗

Tensile properties of resin-infiltrated demineralized human dentin.

The ability of adhesive resins to restore the physical properties of demineralized dentin has not been well-documented. The unfilled resins that are used for adhesion have relatively low moduli of elasticity and limited ability to increase dentin stiffness, although they may increase the ultimate tensile strength of dentin. This study tested the hypothesis that resin infiltration of demineralized dentin can restore its tensile properties to those of mineralized dentin. Small (ca. 0.5 mm thick x 0.5 mm wide) specimens of demineralized human dentin were infiltrated with one of five different dentin bonding resins over many hours, to determine how these resins altered the tensile properties of dentin. Tensile stress and strain were measured in these and control (mineralized and demineralized) specimens until their ultimate failure. The results indicate that some adhesive resins, after infiltrating demineralized dentin, can restore and even exceed the ultimate tensile strength of mineralized dentin. These resins increased the modulus of elasticity of resin-infiltrated dentin to values equal to or greater than those of the resins but far below those of mineralized dentin. Although the conditions in this experiment were far removed from the manufacturer's recommendations or clinical practice, the results support the potential of resin infiltration for reinforcing dentin.

Acid Etching, Dental↗

Trachyspic acid, a new metabolite produced by Talaromyces trachyspermus, that inhibits tumor cell heparanase: taxonomy of the producing strain, fermentation, isolation, structural elucidation, and biological activity.

Trachyspic acid, a new metabolite that inhibited heparanase, was isolated from the culture broth of Talaromyces trachyspermus SANK 12191. Its structure was deduced from NMR spectral analyses and chemical reactions as a tricarboxylic acid derivative containing a spiroketal. The IC50 value of trachyspic acid against heparanase was 36 microM.

Ascomycota↗

Vertebral slip in lumbar spondylolysis and spondylolisthesis. Long-term follow-up of 22 adult patients.

We studied the aetiology of vertebral slip in a long-term follow-up of 22 adult patients with isthmic spondylolysis or spondylolisthesis of L5. Of the 18 with spondylolysis without slip, 13 showed no slip after ten years, but five developed displacement of over 5%. All four patients with spondylolisthesis showed progression of the slip. We found that the vertical thickness of the transverse process of L5 was significantly greater (p < 0.01) in the 13 patients with no slip than in the other two groups. The relationship of vertebral slip to the shape of the transverse processes of L5 may be explained by differences in the bulk or physiological strength of the posterior bands of the iliolumbar ligament.

Adolescent↗

Effect of pulpal pressure on adhesion of resin composite to dentin: bovine serum versus saline.

The purpose of this study was to compare the tensile bond strengths of resin composite to dentin, mediated by two new bonding systems (Scotchbond Multi-Purpose and Clearfil Liner Bond II), under simulated pulpal pressure when diluted bovine serum or saline was used as the pulpal fluid. The bond strengths of the two bonding systems to dentin (under a pulpal pressure of 15 cm of water) obtained when bovine serum was used were statistically significantly higher than those obtained when saline was used. These data suggest that the primers of these bonding systems decreased the dentinal permeability when the bovine serum pulpal fluid was used through the precipitation of serum proteins by the primers in the dentinal tubules. This may have allowed better penetration of the bonding resin monomers into the conditioned dentinal structure, thus improving the bond strength. These findings support the idea that topical application of dentinal bonding systems may be an effective therapy for treating hypersensitive dentin.

Animals↗

Treatment and prognosis of a vertically fractured maxillary molar with widely separated segments: a case report.

This is a report of the treatment and prognosis of a maxillary second molar exhibiting a complete vertical crown-root fracture. The buccal and palatal segments were widely separated by as much as 2 mm and were immobile. To restore this tooth, it was essential to bring the segments into close apposition. This was accomplished by application of orthodontic elastics to the tooth crown in combination with a wire splint. After approximately 1 month of continuous use of the orthodontic elastics, the dislodged segments were suitably repositioned close to their original positions. The tooth was then endodontically treated and restored with a cast complete crown. The restored tooth has been functioning well, with periodic periodontal maintenance, for more than 3.5 years, indicating a promising prognosis.

Adult↗